1.Predisposing Risk Factors Affecting Reversibility of Left Ventricular Diastolic Filling Pattern in Patients with Preserved Ejection Fraction
Dong-Gil KIM ; Sungsoo CHO ; Seongjin PARK ; Gi Rim KIM ; Kyu-Yong KO ; Sung Eun KIM ; Ji-won HWANG ; Joon-Hyung DOH ; Sung Uk KWON ; Jae-Jin KWAK ; June NAMGUNG ; Sung Woo CHO
Yonsei Medical Journal 2025;66(1):1-8
Purpose:
Improvement of left ventricular (LV) diastolic dysfunction (DD) is known to be a good prognostic factor in patients with heart failure with reduced ejection fraction (EF). In the present study, we investigated the predisposing risk factors affecting the reversibility of LV diastolic filling pattern (DFP) in patients with preserved EF.
Materials and Methods:
A total of 600 patients with pseudonormal LVDFP and preserved EF who underwent follow-up echocardiography were enrolled between 2011 and 2020. We compared their index and follow-up echocardiography findings and determined the predisposing risk factor affecting the reversibility of LVDFP.
Results:
Comparing the index and follow-up echocardiography findings showed that 379 (63%) patients had improved to normal or impaired relaxation LVDFP (improved group) and 221 (37%) patients had maintained or worsened LVDFP (unimproved group).The incidence of paroxysmal atrial fibrillation (PAF) was significantly higher in the unimproved group than in the improved group (4.7% vs. 9.5%, p=0.026). After adjustment for relevant clinical risk factors of diastolic dysfunction, PAF was determined to be an independent predisposing risk factor for the unimproved LVDFP (odds ratio: 2.10, 95% confidence interval: 1.06–4.15, p=0.033).Among the parameters of diastolic dysfunction in follow-up echocardiography, the left atrial volume index, mean E/A ratio, and E/e' were significantly improved in patients without PAF but remained in patients with PAF.
Conclusion
We identified that PAF was an independent predisposing risk factor of the unimproved LVDFP in patients with pseudonormal LVDFP and preserved EF. Therefore, early detection and management of PAF might be required in patients with LVDD and preserved EF to prevent adverse cardiovascular events.
2.Predisposing Risk Factors Affecting Reversibility of Left Ventricular Diastolic Filling Pattern in Patients with Preserved Ejection Fraction
Dong-Gil KIM ; Sungsoo CHO ; Seongjin PARK ; Gi Rim KIM ; Kyu-Yong KO ; Sung Eun KIM ; Ji-won HWANG ; Joon-Hyung DOH ; Sung Uk KWON ; Jae-Jin KWAK ; June NAMGUNG ; Sung Woo CHO
Yonsei Medical Journal 2025;66(1):1-8
Purpose:
Improvement of left ventricular (LV) diastolic dysfunction (DD) is known to be a good prognostic factor in patients with heart failure with reduced ejection fraction (EF). In the present study, we investigated the predisposing risk factors affecting the reversibility of LV diastolic filling pattern (DFP) in patients with preserved EF.
Materials and Methods:
A total of 600 patients with pseudonormal LVDFP and preserved EF who underwent follow-up echocardiography were enrolled between 2011 and 2020. We compared their index and follow-up echocardiography findings and determined the predisposing risk factor affecting the reversibility of LVDFP.
Results:
Comparing the index and follow-up echocardiography findings showed that 379 (63%) patients had improved to normal or impaired relaxation LVDFP (improved group) and 221 (37%) patients had maintained or worsened LVDFP (unimproved group).The incidence of paroxysmal atrial fibrillation (PAF) was significantly higher in the unimproved group than in the improved group (4.7% vs. 9.5%, p=0.026). After adjustment for relevant clinical risk factors of diastolic dysfunction, PAF was determined to be an independent predisposing risk factor for the unimproved LVDFP (odds ratio: 2.10, 95% confidence interval: 1.06–4.15, p=0.033).Among the parameters of diastolic dysfunction in follow-up echocardiography, the left atrial volume index, mean E/A ratio, and E/e' were significantly improved in patients without PAF but remained in patients with PAF.
Conclusion
We identified that PAF was an independent predisposing risk factor of the unimproved LVDFP in patients with pseudonormal LVDFP and preserved EF. Therefore, early detection and management of PAF might be required in patients with LVDD and preserved EF to prevent adverse cardiovascular events.
3.Predisposing Risk Factors Affecting Reversibility of Left Ventricular Diastolic Filling Pattern in Patients with Preserved Ejection Fraction
Dong-Gil KIM ; Sungsoo CHO ; Seongjin PARK ; Gi Rim KIM ; Kyu-Yong KO ; Sung Eun KIM ; Ji-won HWANG ; Joon-Hyung DOH ; Sung Uk KWON ; Jae-Jin KWAK ; June NAMGUNG ; Sung Woo CHO
Yonsei Medical Journal 2025;66(1):1-8
Purpose:
Improvement of left ventricular (LV) diastolic dysfunction (DD) is known to be a good prognostic factor in patients with heart failure with reduced ejection fraction (EF). In the present study, we investigated the predisposing risk factors affecting the reversibility of LV diastolic filling pattern (DFP) in patients with preserved EF.
Materials and Methods:
A total of 600 patients with pseudonormal LVDFP and preserved EF who underwent follow-up echocardiography were enrolled between 2011 and 2020. We compared their index and follow-up echocardiography findings and determined the predisposing risk factor affecting the reversibility of LVDFP.
Results:
Comparing the index and follow-up echocardiography findings showed that 379 (63%) patients had improved to normal or impaired relaxation LVDFP (improved group) and 221 (37%) patients had maintained or worsened LVDFP (unimproved group).The incidence of paroxysmal atrial fibrillation (PAF) was significantly higher in the unimproved group than in the improved group (4.7% vs. 9.5%, p=0.026). After adjustment for relevant clinical risk factors of diastolic dysfunction, PAF was determined to be an independent predisposing risk factor for the unimproved LVDFP (odds ratio: 2.10, 95% confidence interval: 1.06–4.15, p=0.033).Among the parameters of diastolic dysfunction in follow-up echocardiography, the left atrial volume index, mean E/A ratio, and E/e' were significantly improved in patients without PAF but remained in patients with PAF.
Conclusion
We identified that PAF was an independent predisposing risk factor of the unimproved LVDFP in patients with pseudonormal LVDFP and preserved EF. Therefore, early detection and management of PAF might be required in patients with LVDD and preserved EF to prevent adverse cardiovascular events.
4.Predisposing Risk Factors Affecting Reversibility of Left Ventricular Diastolic Filling Pattern in Patients with Preserved Ejection Fraction
Dong-Gil KIM ; Sungsoo CHO ; Seongjin PARK ; Gi Rim KIM ; Kyu-Yong KO ; Sung Eun KIM ; Ji-won HWANG ; Joon-Hyung DOH ; Sung Uk KWON ; Jae-Jin KWAK ; June NAMGUNG ; Sung Woo CHO
Yonsei Medical Journal 2025;66(1):1-8
Purpose:
Improvement of left ventricular (LV) diastolic dysfunction (DD) is known to be a good prognostic factor in patients with heart failure with reduced ejection fraction (EF). In the present study, we investigated the predisposing risk factors affecting the reversibility of LV diastolic filling pattern (DFP) in patients with preserved EF.
Materials and Methods:
A total of 600 patients with pseudonormal LVDFP and preserved EF who underwent follow-up echocardiography were enrolled between 2011 and 2020. We compared their index and follow-up echocardiography findings and determined the predisposing risk factor affecting the reversibility of LVDFP.
Results:
Comparing the index and follow-up echocardiography findings showed that 379 (63%) patients had improved to normal or impaired relaxation LVDFP (improved group) and 221 (37%) patients had maintained or worsened LVDFP (unimproved group).The incidence of paroxysmal atrial fibrillation (PAF) was significantly higher in the unimproved group than in the improved group (4.7% vs. 9.5%, p=0.026). After adjustment for relevant clinical risk factors of diastolic dysfunction, PAF was determined to be an independent predisposing risk factor for the unimproved LVDFP (odds ratio: 2.10, 95% confidence interval: 1.06–4.15, p=0.033).Among the parameters of diastolic dysfunction in follow-up echocardiography, the left atrial volume index, mean E/A ratio, and E/e' were significantly improved in patients without PAF but remained in patients with PAF.
Conclusion
We identified that PAF was an independent predisposing risk factor of the unimproved LVDFP in patients with pseudonormal LVDFP and preserved EF. Therefore, early detection and management of PAF might be required in patients with LVDD and preserved EF to prevent adverse cardiovascular events.
5.Predisposing Risk Factors Affecting Reversibility of Left Ventricular Diastolic Filling Pattern in Patients with Preserved Ejection Fraction
Dong-Gil KIM ; Sungsoo CHO ; Seongjin PARK ; Gi Rim KIM ; Kyu-Yong KO ; Sung Eun KIM ; Ji-won HWANG ; Joon-Hyung DOH ; Sung Uk KWON ; Jae-Jin KWAK ; June NAMGUNG ; Sung Woo CHO
Yonsei Medical Journal 2025;66(1):1-8
Purpose:
Improvement of left ventricular (LV) diastolic dysfunction (DD) is known to be a good prognostic factor in patients with heart failure with reduced ejection fraction (EF). In the present study, we investigated the predisposing risk factors affecting the reversibility of LV diastolic filling pattern (DFP) in patients with preserved EF.
Materials and Methods:
A total of 600 patients with pseudonormal LVDFP and preserved EF who underwent follow-up echocardiography were enrolled between 2011 and 2020. We compared their index and follow-up echocardiography findings and determined the predisposing risk factor affecting the reversibility of LVDFP.
Results:
Comparing the index and follow-up echocardiography findings showed that 379 (63%) patients had improved to normal or impaired relaxation LVDFP (improved group) and 221 (37%) patients had maintained or worsened LVDFP (unimproved group).The incidence of paroxysmal atrial fibrillation (PAF) was significantly higher in the unimproved group than in the improved group (4.7% vs. 9.5%, p=0.026). After adjustment for relevant clinical risk factors of diastolic dysfunction, PAF was determined to be an independent predisposing risk factor for the unimproved LVDFP (odds ratio: 2.10, 95% confidence interval: 1.06–4.15, p=0.033).Among the parameters of diastolic dysfunction in follow-up echocardiography, the left atrial volume index, mean E/A ratio, and E/e' were significantly improved in patients without PAF but remained in patients with PAF.
Conclusion
We identified that PAF was an independent predisposing risk factor of the unimproved LVDFP in patients with pseudonormal LVDFP and preserved EF. Therefore, early detection and management of PAF might be required in patients with LVDD and preserved EF to prevent adverse cardiovascular events.
6.Pharmacological properties of Technekitty injection (Tc-99m) in diagnosing feline hyperthyroidism
Jae Cheong LIM ; So-Young LEE ; Eun Ha CHO ; Yu Mi JUNG ; Ki Hwan PARK ; Young Uk PARK ; Sung Soo NAM ; Tae Hoon LEE ; Jae Won LEE ; Jisu SUN ; Hye Kyung CHUNG ; Yong Jin LEE ; Yeon CHAE ; Byeong-Teck KANG
Journal of Biomedical and Translational Research 2024;25(4):185-199
Thyroid scanning using technetium-99m ( 99mTc) is the gold standard for diagnosing feline hyperthyroidism. In cats with an overactive thyroid, a thyroid scan is the most appropriate imaging technique to detect and localize any hyperfunctional adenomatous thyroid tissue. In this study, the pharmacological properties of the Technekitty injection (Tc-99m), developed as a diagnostic agent for feline hyperthyroidism using 99mTc as an active ingredient, were tested in FRTL-5 thyroid follicular cell line and ICR mice. The percentage of cell uptake of the Tc-99m in FRTL-5 thyroid cells was 0.182 ± 0.018%, which was about 6 times higher compared to Clone 9 hepatocytes. This uptake decreased by 38.2% due to competitive inhibition by iodine (sodium iodide). In tissue distribution tests by using ICR mice, the highest distribution was observed in the liver, kidneys, spleen, lungs, and femur at 0.083 hours after administration, and this distribution decreased as the compound was excreted through the kidneys, the pri-mary excretory organ. Maximum distribution was confirmed at 1 hour in the small intestine, 6hours in the large intestine, and 2 hours in the thyroid gland. Additionally, the total amount excreted through urine and feces over 48 hours (2 days) was 78.80% of the injected dose, with 37.70% (47.84% of the total excretion) excreted through urine and 41.10% (52.16% of the total excretion) through feces. In conclusion, the Tc-99m has the same mechanism of action, potency, absorption, distribution, metabolism, and excretion characteristics as 99mTc used for feline hyperthyroidism in the United States, Europe, and other countries, because the Technekitty injection (Tc-99m) contains 99mTc as its sole active ingredient. Based on these results, the Technekitty injection (Tc-99m) is expected to be safely used in the clinical diagnosis of feline hyperthyroidism.
7.Factors associated with patient satisfaction after arthroscopic rotator cuff repair: do they differ by age?
Jung-Han KIM ; Soo-Hwan JUNG ; Dae-Hyun PARK ; Yong-Uk KWON ; Hyo-Young LEE
Clinics in Shoulder and Elbow 2024;27(3):345-352
Background:
Several studies have investigated factors affecting patient satisfaction after arthroscopic rotator cuff repair (ARCR); however, it is unknown if these factors vary according to age. Therefore, this study aimed to evaluate the factors associated with satisfaction of ARCR in individuals 70 years and older versus younger patients.
Methods:
Among 319 consecutive patients who underwent ARCR, 173 were included. Patients were divided into an old age group (≥70 years) and a young age group (<70 years), and the two age groups were further divided into satisfied and unsatisfied subgroups. Patient satisfaction was evaluated at the final follow-up visit using a binary question (yes or no). Clinical outcomes were assessed preoperatively and at the final follow-up.
Results:
Satisfaction rates in the older and younger age groups were 75.41% and 79.47%, respectively. Mean changes in Constant and American Shoulder and Elbow Surgeons scores were significantly different between the satisfied and unsatisfied subgroups (P=0.031 and P=0.012, respectively) in the young patients. In the old patients, there was a significant difference in the mean change in depression subscale of the Hospital Anxiety and Depression Scale (P=0.031) and anxiety subscale of the Hospital Anxiety and Depression Scale (P=0.044) scores between the satisfied and unsatisfied subgroups.
Conclusions
Factors affecting patient satisfaction after ARCR differed according to age. Psychological improvement was more important to elderly patients, whereas restoration of function was more important to younger patients. Pain relief was important for both age groups.Level of evidence: III.
8.Factors associated with patient satisfaction after arthroscopic rotator cuff repair: do they differ by age?
Jung-Han KIM ; Soo-Hwan JUNG ; Dae-Hyun PARK ; Yong-Uk KWON ; Hyo-Young LEE
Clinics in Shoulder and Elbow 2024;27(3):345-352
Background:
Several studies have investigated factors affecting patient satisfaction after arthroscopic rotator cuff repair (ARCR); however, it is unknown if these factors vary according to age. Therefore, this study aimed to evaluate the factors associated with satisfaction of ARCR in individuals 70 years and older versus younger patients.
Methods:
Among 319 consecutive patients who underwent ARCR, 173 were included. Patients were divided into an old age group (≥70 years) and a young age group (<70 years), and the two age groups were further divided into satisfied and unsatisfied subgroups. Patient satisfaction was evaluated at the final follow-up visit using a binary question (yes or no). Clinical outcomes were assessed preoperatively and at the final follow-up.
Results:
Satisfaction rates in the older and younger age groups were 75.41% and 79.47%, respectively. Mean changes in Constant and American Shoulder and Elbow Surgeons scores were significantly different between the satisfied and unsatisfied subgroups (P=0.031 and P=0.012, respectively) in the young patients. In the old patients, there was a significant difference in the mean change in depression subscale of the Hospital Anxiety and Depression Scale (P=0.031) and anxiety subscale of the Hospital Anxiety and Depression Scale (P=0.044) scores between the satisfied and unsatisfied subgroups.
Conclusions
Factors affecting patient satisfaction after ARCR differed according to age. Psychological improvement was more important to elderly patients, whereas restoration of function was more important to younger patients. Pain relief was important for both age groups.Level of evidence: III.
9.Factors associated with patient satisfaction after arthroscopic rotator cuff repair: do they differ by age?
Jung-Han KIM ; Soo-Hwan JUNG ; Dae-Hyun PARK ; Yong-Uk KWON ; Hyo-Young LEE
Clinics in Shoulder and Elbow 2024;27(3):345-352
Background:
Several studies have investigated factors affecting patient satisfaction after arthroscopic rotator cuff repair (ARCR); however, it is unknown if these factors vary according to age. Therefore, this study aimed to evaluate the factors associated with satisfaction of ARCR in individuals 70 years and older versus younger patients.
Methods:
Among 319 consecutive patients who underwent ARCR, 173 were included. Patients were divided into an old age group (≥70 years) and a young age group (<70 years), and the two age groups were further divided into satisfied and unsatisfied subgroups. Patient satisfaction was evaluated at the final follow-up visit using a binary question (yes or no). Clinical outcomes were assessed preoperatively and at the final follow-up.
Results:
Satisfaction rates in the older and younger age groups were 75.41% and 79.47%, respectively. Mean changes in Constant and American Shoulder and Elbow Surgeons scores were significantly different between the satisfied and unsatisfied subgroups (P=0.031 and P=0.012, respectively) in the young patients. In the old patients, there was a significant difference in the mean change in depression subscale of the Hospital Anxiety and Depression Scale (P=0.031) and anxiety subscale of the Hospital Anxiety and Depression Scale (P=0.044) scores between the satisfied and unsatisfied subgroups.
Conclusions
Factors affecting patient satisfaction after ARCR differed according to age. Psychological improvement was more important to elderly patients, whereas restoration of function was more important to younger patients. Pain relief was important for both age groups.Level of evidence: III.
10.Pharmacological properties of Technekitty injection (Tc-99m) in diagnosing feline hyperthyroidism
Jae Cheong LIM ; So-Young LEE ; Eun Ha CHO ; Yu Mi JUNG ; Ki Hwan PARK ; Young Uk PARK ; Sung Soo NAM ; Tae Hoon LEE ; Jae Won LEE ; Jisu SUN ; Hye Kyung CHUNG ; Yong Jin LEE ; Yeon CHAE ; Byeong-Teck KANG
Journal of Biomedical and Translational Research 2024;25(4):185-199
Thyroid scanning using technetium-99m ( 99mTc) is the gold standard for diagnosing feline hyperthyroidism. In cats with an overactive thyroid, a thyroid scan is the most appropriate imaging technique to detect and localize any hyperfunctional adenomatous thyroid tissue. In this study, the pharmacological properties of the Technekitty injection (Tc-99m), developed as a diagnostic agent for feline hyperthyroidism using 99mTc as an active ingredient, were tested in FRTL-5 thyroid follicular cell line and ICR mice. The percentage of cell uptake of the Tc-99m in FRTL-5 thyroid cells was 0.182 ± 0.018%, which was about 6 times higher compared to Clone 9 hepatocytes. This uptake decreased by 38.2% due to competitive inhibition by iodine (sodium iodide). In tissue distribution tests by using ICR mice, the highest distribution was observed in the liver, kidneys, spleen, lungs, and femur at 0.083 hours after administration, and this distribution decreased as the compound was excreted through the kidneys, the pri-mary excretory organ. Maximum distribution was confirmed at 1 hour in the small intestine, 6hours in the large intestine, and 2 hours in the thyroid gland. Additionally, the total amount excreted through urine and feces over 48 hours (2 days) was 78.80% of the injected dose, with 37.70% (47.84% of the total excretion) excreted through urine and 41.10% (52.16% of the total excretion) through feces. In conclusion, the Tc-99m has the same mechanism of action, potency, absorption, distribution, metabolism, and excretion characteristics as 99mTc used for feline hyperthyroidism in the United States, Europe, and other countries, because the Technekitty injection (Tc-99m) contains 99mTc as its sole active ingredient. Based on these results, the Technekitty injection (Tc-99m) is expected to be safely used in the clinical diagnosis of feline hyperthyroidism.

Result Analysis
Print
Save
E-mail