1.Effects of gene silencing Cyclooxygenase-2 cooperated with hyperbaric oxygen on neurological repair and apoptosis, autophagy in cerebral hemorrhage rats
Qiang PAN ; Lin ZHU ; Yong GAO ; Jun ZHU ; Shuai ZHANG ; Qiang LI ; Xingtao DIAO ; Chunyu SONG
Chinese Journal of Emergency Medicine 2024;33(1):39-46
Objective:To investigate the effects of gene silencing inducible cyclooxygenase-2 (COX-2) combined with hyperbaric oxygen (HBO) on neuronal cell edema, apoptosis, autophagy and neural functional recovery in rats with intracerebral hemorrhage.Methods:SPF-grade adult male SD rats ( n=96) were used to establish a cerebral hemorrhage model through stereotactic injection of thrombin VII into the caudate nucleus. They were randomized (random number) into 4 groups ( n=24/group): control group, hyperbaric oxygen (HBO) group, COX-2 RNAi group and combined group (COX-2 RNAi+HBO). The siRNA plasmid targeting silencing COX-2 gene expression was constructed. After group treatment, the four rats were randomly selected from each group for testing in each category. Postoperative day 1, 7, and 14 were assessed using the modified neurological severity score (mNSS) for evaluating neurofunctional deficits. On the 7th day, the water content of the brain tissue was measured using the dry/wet weight method. The blood-brain barrier permeability was assessed using the Evans method. Annexin V and TUNEL assays were employed to assess the apoptotic rate of neural cells. The mRNA expression level of COX-2 in brain tissue was determined using the RT-PCR method. The protein expression levels of Beclin-1, COX-2, aquaporin 4 (AQP-4), B cell lymphoma/lewkmia-2 (Bcl-2), caspase-3, hypoxia-inducible factor-1α (HIF-1α) and matrix metalloprotein-2/9 (MMP-2/9) were detected by Western blot (WB). SPSS software was used for data analysis. One-way ANOVA was used for inter group comparisons and LSD- t test was used for further pairwise comparison. Results:The SD rat intracerebral hemorrhage model and plasmid construction were successfully achieved. The mNSS scores were significantly decreased in COX-2 RNAi, HBO and combined groups compared with control group on the 7th day and 14th day (all P<0.01), especially in combined group ( P<0.01). The contents of Evans blue and the water content of brain tissue of all treatment groups were significantly lower than those in control group (all P<0.05), especially in combined group ( P<0.01). The apoptotic rate of neural cells decreased in all treatment groups compared with the control group (all P<0.05), and the combined group decreased the most ( P<0.01). The mRNA expression levels of COX-2 were significantly decreased in all treatment groups compared with the control group (all P<0.01), and combined group silenced COX-2 expression most obviously ( P<0.05). The results of WB showed that the protein expression levels of Beclin-1, COX-2, AQP-4, Caspase-3, HIF-1α, MMP-2/9 were significantly lower than control group (all P<0.05), while the expression of Bcl-2 was increased in all treatment groups (all P<0.01). Among them, the combined group exhibited the most pronounced trend ( P<0.01). Conclusions:Gene silencing of COX-2 in combination with hyperbaric oxygen therapy can effectively restore neurological function in rats with cerebral hemorrhage. The mechanism may be associated with reduced blood-brain barrier permeability, alleviated brain edema, and inhibition of neuronal apoptosis and autophagy.
2.Exploration on Characteristics of Acupoint Efficacy Based on the Self-developed ACU&MOX-DATA Platform
Sihui LI ; Shuqing LIU ; Qiang TANG ; Ruibin ZHANG ; Wei CHEN ; Hao HONG ; Bingmei ZHU ; Xun LAN ; Yong WANG ; Shuguang YU ; Qiaofeng WU
Chinese Journal of Information on Traditional Chinese Medicine 2024;31(2):64-69
Objective To explore the effects of different acupoints,different target organs,and different interventions on acupoint efficacy based on ACU&MOX-DATA platform;To illustrate and visualize whether the above factors have the characteristics of"specific effect"or"common effect"of acupoint efficacy.Methods The multi-source heterogeneous data were integrated from the original omics data and public omics data.After standardization,differential gene analysis,disease pathology network analysis,and enrichment analysis were performed using Batch Search and Stimulation Mode modules in ACU&MOX-DATA platform under the conditions of different acupoints,different target organs,and different interventions.Results Under the same disease state and the same intervention,there were differences in effects among different acupoints;under the same disease state,the same acupoint and intervention,the responses produced by different target organs were not completely consistent;under the same disease state and acupoint,there were differences in effects among different intervention measures.Conclusion Based on the analysis of ACU&MOX-DATA platform,it is preliminary clear that acupoints,target organs,and interventions are the key factors affecting acupoint efficacy.Meanwhile,the above results have indicated that there are specific or common regulatory characteristics of acupoint efficacy.Applying ACU&MOX-DATA platform to analyze and visualize the critical scientific problems in the field of acupuncture and moxibustion can provide references for deepening acupoint cognition,guiding clinical acupoint selection,and improving clinical efficacy.
3.Development of prefilled portable intelligent venous transfusion pump
Zhu-Qiang CHENG ; Peng-Yun JI ; Yong-Fen ZENG ; Min YANG ; Yi JIN ; Hong-Jun LIU
Chinese Medical Equipment Journal 2024;45(5):111-114
Objective To develop a prefilled portable intelligent intravenous transfusion pump to facilitate fast and convenient fluid pumping during emergency treatment and casualty transport.Methods The prefilled portable intelligent venous transfusion pump was composed of a driver module,a pump module,a human-machine interface,a prefilled sterile infusion bag and a pump catheter.The driver module adopted integrated design and applied a high-voltage DC-AC converter to driving the piezoelectric pump used as the power source of the pump module;the human-machine interface consisted of several keys for on/off,rate adjustment,switching and confirmation;the prefilled sterile infusion bag was made of medical-grade polypropylene,and the pump catheter was made of medical silicone rubber.Results The transfusion pump developed could be worn on the casualty limb and did not require height difference for intravenous infusion,which enhanced intravenous drug delivery in portability,reliability and intelligence.Conclusion The transfusion pump developed gains advantages in low size,weight and easy operation,and thus is worthy promoting for venous transfusion in battlefield conditions and field emergency environments.[Chinese Medical Equipment Journal,2024,45(5):111-114]
4.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
5. Discussion on safety and related pharmacological mechanism of compound anshen essential oil in relieving sleep disorders
Lei ZHOU ; Yue GAO ; Lei ZHOU ; Wei ZHOU ; Yong-Qiang ZHOU ; Yue GAO ; Li-Yun ZHU ; Peng-Yi HU ; Ming YANG ; Qin ZHENG
Chinese Pharmacological Bulletin 2023;39(3):580-587
Aim To study the hypnotic effect and safety of compound anshen essential oil. Methods Gas chromatograph-mass spectrometer (GC-MS) was used to analyze the main active components of compound anshen essential oil. The mouse model of insomnia was established by intraperitoneal injection of para-chloro-phenyl alanine ( PC PA ) , combined with pentobarbital sodium sleep experiment and EEG characteristic monitoring in rats to study the hypnotic effect and mechanism. The safety of compound anshen essential oil was evaluated by acute toxicity test, skin irritation/allergy test and 90-day repeated administration toxicity test. The clinical effect and safety were evaluated by using the sleep monitoring technology for micro-motion sensitive mattress. Results Four components, including Atractylone (34.61%), (+) -Limonene (17.80%) , Linalool (11.63%), and Ocimene (11.67%) , were detected as the main active components of compound anshen essential oil. Compound anshen essential oil in-halation administration for seven days could effectively reduce the autonomic activity of insomnia mice, shorten the sleep latency (P <0.05) , improve the sleep duration, increase of neurotransmitters such as 5-hydroxy tryptamine (5-HT) and -γ-aminobutyric acid (GABA) in brain of mice with insomnia, and the medium dose group had better hypnotic effect. There was no death or adverse reaction in the safety evaluation test. The sleep balance index of 10 subjects with difficulty in falling a-sleep significantly increased (P <0.05), sleep latency was significantly shortened (P <0.05) , total sleep duration and sleep efficiency were improved, and no ad¬verse reactions were found after using the compound anshen essential oil for two days. Conclusions The compound anshen essential oil developed by the research team is safe and effective in relieving sleep disorders, which may be closely related to the co-regulation of the levels of neurotransmitters such as 5-HT and GABA by the four main active components.
6.Meta-analysis of the effects of low-dose ionizing radiation on the thyroid of medical radiation workers
Yong YANG ; Qiang WANG ; Luting YANG ; Aiqing YU ; Zhixin ZHAO ; Bo ZHU ; Liyan JING
Chinese Journal of Radiological Medicine and Protection 2023;43(6):447-456
Objective:To assess the effects of low-dose ionizing radiation on the thyroid of medical radiation workers.Methods:Based on the inclusion and exclusion criteria, 27 articles, involving 22 937 individuals, were screened finally from relevant literature published from 1996 to 2022. Meta-analysis was carried out using Stata 16.0 for serum levels of triiodothyronine (T 3), free triiodothyronine (FT 3), thyroid hormone (T 4), free thyroid hormone (FT 4), thyrotropin-stimulating hormone (TSH) and thyroid nodule rates. As well, subgroup analysis were carried out of thyroid function in different types of radiation workers. Results:The standardized mean difference (SMD) at T 3 and T 4 levels for radiation workers was -0.19 (-0.37, -0.01) and -0.34 (-0.38, -0.30), lower than that of control group ( Z=2.07, -16.06, P<0.05). The SMD at FT 4 levels for radiation workers was 0.22 (0.06, 0.39), higher than control group ( Z=2.61, P<0.05). The relative risk of thyroid nodules in radiation workers was 1.47 (1.19, 1.82), higher than that of control group ( Z=-3.58, P<0.05). The analysis result for subgroup showed that the SMD for T 3, T 4 and TSH levels in the interventional radiology workers were -0.29 (-0.51, -0.07), -0.31 (-0.47, -0.15) and -0.43 (-0.73, -0.13) ( Z=-2.55, -3.86, -2.82, P<0.05), respectively, and the SMD for T 4 levels in the nuclear medicine workers was -0.26 (-0.45, -0.07), which meaned a reduced risk compared to the control group ( Z=-2.70, P<0.05). Conclusions:Long-term low doses of ionising radiation may have adverse effects on thyroid hormone and thyroid nodule in radiation workers, particularly in interventional radiology workers, and attention should be focused on their radiation protection.
7.Study on the relationship between the age at natural menopause and postmenopausal metabolic syndrome.
Yong Jun WU ; Wei Sen ZHANG ; Feng ZHU ; Tong ZHU ; Ya Li JIN ; Jing PAN ; Chao Qiang JIANG
Chinese Journal of Preventive Medicine 2023;57(3):433-437
To explore the relationship between the early or delayed age at natural menopause and metabolic syndrome (MS) in women. A total of 4 734 natural menopausal women who completed the baseline survey from November 2017 to January 2020 in the Guangzhou Middle-aged and Elderly Chronic Disease Prospective Cohort Study were selected in this cross-sectional study. Data on general demographic characteristics, disease history and female physiological health indicators were collected. Logistic regression model and restricted cubic spline curve were used to analyze the relationship between the age at natural menopause and MS. The results showed that the mean age of the subjects was (60±6) years old. The median (Q1,Q3) age at natural menopause was 50 (49, 52) years old, and the prevalence of MS was 14.8%(699/4 734). After adjusting for confounders, the age at natural menopause was closely related to MS in an approximate"U"shape. Compared with the group of normal age at natural menopause, the early age at menopause (OR=1.52, 95%CI: 1.12-2.06) and delayed age at menopause (OR=1.77, 95%CI: 1.36-2.30) had a higher risk of MS. In the group with time since menopause ≤6 years and 7-9 years, the risk of MS in the group with delayed age at menopause was 2.40 times (95%CI: 1.54-3.75) and 2.19 times (95%CI: 1.11-4.31) higher than that in the group with normal menopausal age, respectively. In conclusion, the early and delayed age at natural menopause increased the risk of MS. The increased risk of MS in delayed age at natural menopause mainly occurred within 10 years since menopause.
Middle Aged
;
Aged
;
Female
;
Humans
;
Child
;
Postmenopause
;
Metabolic Syndrome/epidemiology*
;
Prospective Studies
;
Cross-Sectional Studies
;
Menopause/physiology*
;
Risk Factors
8.Methodology and application of process analytical technology (PAT) for traditional Chinese medicine manufacturing:a review.
Hao-Shu XIONG ; Qiang ZHANG ; Shun-Nan ZHANG ; Jin-Yong CAI ; Jing SU ; Yong-Hong ZHU ; Kai-Jing YAN
China Journal of Chinese Materia Medica 2023;48(1):22-29
Owing to the advancement in pharmaceutical technology, traditional Chinese medicine industry has seen rapid development. Preferring conventional manufacturing mode, pharmaceutical enterprises of traditional Chinese medicine have no effective process detection tools and process control methods. As a result, the quality of the final products mainly depends on testing and the quality is inconsistent in the same batch. Process analytical technology(PAT) for traditional Chinese medicine manufacturing, as one of the key advanced manufacturing techniques, can break through the bottleneck in quality control of medicine manufacturing, thus improving the production efficiency and product quality and reducing the material and energy consumption. It is applicable to the process control and real-time release of advanced manufacturing modes such as intelligent manufacturing and continuous manufacturing. This paper summarized the general idea of PAT for traditional Chinese medicine manufacturing. Through the analysis of the characteristics and status quo of the technology, we summed up the methodology for the continuous application and improvement of PAT during the whole life-cycle of traditional Chinese medicine. The five key procedures(process understanding, process detection, process modeling, process control, and continuous improvement) were summarized, and the application was reviewed. Finally, we proposed suggestions for the technical and regulatory challenges in implementing PAT in traditional Chinese medicine industry. This paper aims to provide a reference for development and application of PAT in advanced manufacturing, intelligent manufacturing, and continuous manufacturing of traditional Chinese medicine industry.
Medicine, Chinese Traditional
;
Drugs, Chinese Herbal
;
Technology, Pharmaceutical
;
Drug Industry
;
Quality Control
9.Predictive value of the proportion of hibernating myocardium in total perfusion defect on reverse remodeling in patients with HFrEF underwent coronary artery bypass graft.
Yao LU ; Jian CAO ; En Jun ZHU ; Ming Xin GAO ; Tian Tian MOU ; Ying ZHANG ; Xiao Fen XIE ; Yi TIAN ; Ming Kai YUN ; Jing Jing MENG ; Xiu Bin YANG ; Yong Qiang LAI ; Ran DONG ; Xiao Li ZHANG
Chinese Journal of Cardiology 2023;51(4):384-392
Objective: To evaluate the predictive value of the proportion of hibernating myocardium (HM) in total perfusion defect (TPD) on reverse left ventricle remodeling (RR) after coronary artery bypass graft (CABG) in patients with heart failure with reduced ejection fraction (HFrEF) by 99mTc-methoxyisobutylisonitrile (MIBI) single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) combined with 18F-flurodeoxyglucose (FDG) gated myocardial imaging positron emission computed tomography (PET). Methods: Inpatients diagnosed with HFrEF at the Cardiac Surgery Center, Anzhen Hospital of Capital Medical University from January 2016 to January 2022 were prospectively recruited. MPI combined with 18F-FDG gated PET was performed before surgery for viability assessment and the patients received follow-up MPI and 18F-FDG gated PET at different stages (3-12 months) after surgery. Δ indicated changes (post-pre). Left ventricular end-systolic volume (ESV) reduced at least 10% was defined as RR, patients were divided into reverse remodeling (RR+) group and the non-reverse group (RR-). Binary logistic regression analysis was used to identify predictors of RR. Receiver operating characteristic (ROC) curve analysis was performed and the area under the curve (AUC) was calculated to assess the cut-off value for predicting RR. Additionally, we retrospectively enrolled inpatients with HFrEF at the Cardiac Surgery Center, Anzhen Hospital of Capital Medical University from January 2021 to January 2022 as the validation group, who underwent MPI and 18F-FDG gated PET before surgery. Echocardiography was performed before CABG and after CABG (3-12 months). In the validation group, the reliability of obtaining the cut-off value for the ROC curve was verified. Results: A total of 28 patients with HFrEF (26 males; age (56.9±8.7) years) were included in the prospective cohort. HM/TPD was significantly higher in the RR+ group than in the RR- group ((51.8%±17.9%) vs. (35.7%±13.9%), P=0.016). Binary logistic regression analysis revealed that HM/TPD was an independent predictor of RR (Odds ratio=1.073, 95% Confidence interval: 1.005-1.145, P=0.035). ROC curve analysis revealed that HM/TPD=38.3% yielded the highest sensitivity, specificity, and accuracy (all 75%) for predicting RR and the AUC was 0.786 (P=0.011). Meanwhile, a total of 100 patients with HFrEF (90 males; age (59.7±9.6) years) were included in the validation group. In the validation group, HM/TPD=38.3% predicted RR in HFrEF patients after CABG with the highest sensitivity, specificity and accuracy (82%, 60% and 73% respectively). Compared with the HFrEF patients in the HM/TPD<38.3% group (n=36), RR and cardiac function improved more significantly in the HM/TPD≥38.3% group (n=64) (all P<0.05). Conclusions: Preoperative HM/TPD ratio is an independent factor for predicting RR in patients with HFrEF after CABG, and HM/TPD≥38.3% can accurately predict RR and the improvement of cardiac function after CABG.
Male
;
Humans
;
Middle Aged
;
Aged
;
Stroke Volume
;
Heart Failure
;
Fluorodeoxyglucose F18
;
Retrospective Studies
;
Reproducibility of Results
;
Prospective Studies
;
Coronary Artery Bypass
;
Ventricular Dysfunction, Left
;
Tomography, Emission-Computed, Single-Photon
;
Perfusion
;
Myocardium
10.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve

Result Analysis
Print
Save
E-mail