1.Concept, design and clinical application of minimally invasive liver transplantation through laparoscopic combined upper midline incision
Shuhong YI ; Hui TANG ; Kaining ZENG ; Xiao FENG ; Binsheng FU ; Qing YANG ; Jia YAO ; Yang YANG ; Guihua CHEN
Organ Transplantation 2025;16(1):67-73
Objective To explore the technical process and clinical application of laparoscopic combined upper midline incision minimally invasive liver transplantation. Methods A retrospective analysis was conducted on 30 cases of laparoscopic combined upper midline incision minimally invasive liver transplantation. The cases were divided into cirrhosis group (15 cases) and liver failure group (15 cases) based on the primary disease. The surgical and postoperative conditions of the two groups were compared. Results All patients successfully underwent laparoscopic "clockwise" liver resection, with no cases of passive conversion to open surgery or intolerance to pneumoperitoneum. In 6 cases, the right lobe was relatively large, and the right hepatic ligaments could not be completely mobilized. One case required an additional reverse "L" incision during open surgery. All patients successfully completed the liver transplantation, with no major intraoperative bleeding, cardiovascular events, or other occurrences in the 30 patients. The model for end-stage liver disease (MELD) score in the cirrhosis group was lower than that in the liver failure group (P<0.001). There were no statistically significant differences between the two groups in terms of age, surgical time, blood loss, anhepatic phase, or cold ischemia time (all P>0.05). During the perioperative period, there was 1 case of hepatic artery embolism, 1 case of portal vein anastomotic stenosis, no complications of hepatic vein and inferior vena cava, and 3 cases of biliary anastomotic stenosis, all of which occurred in the liver failure group. Conclusions In strictly selected cases, the minimally invasive liver transplantation technique combining laparoscopic hepatectomy with upper midline incision for graft implantation has the advantages of smaller incisions, less bleeding, relatively easier operation, and faster postoperative recovery, which is worthy of clinical promotion and application.
2.Optical coherence tomography angiography in diabetic retinopathy: focusing on microvascular changes
Xiongyi YANG ; Guoguo YI ; Yanxia CHEN ; Siyu YANG ; Shibei AI ; Cong ZHENG ; Mingzhe CAO ; Min FU
International Eye Science 2025;25(2):179-190
AIM:To investigate the value of optical coherence tomography angiography(OCTA)indicators in the diagnosis of diabetic retinopathy(DR), and to provide patients with diabetic nephropathy(DN)with more sensitive OCTA screening indicators to detect concurrent DR at an early stage.METHODS: A total of 200 patients who treated in the ophthalmology department of the Seventh Affiliated Hospital, Sun Yat-sen University from 2022 to 2023 were included, including 95 first-diagnosed DR patients and 105 patients without DR, and all patients underwent OCTA examination and a collection of demographics and renal function parameters. After a quality check, automated measurements of the foveal avascular zone area, vessel density(VD), and perfusion density(PD)of both 3 mm×3 mm and 6 mm×6 mm windows were obtained.RESULTS: Using random forest and multivariate Logistic regression methods, we developed a diagnostic model for DR based on 12 variables(age, FBG, SBP, DBP, HbA1c, ALT, ALP, urea/Scr, DM duration, HUA, DN, and CMT). Adding specific OCTA parameters enhanced the efficacy of the existing diagnostic model for DR(outer vessel density in 6 mm×6 mm window, AUC=0.837 vs 0.819, P=0.03). In the study of DN patients, the parameters in the 6 mm×6 mm window improved the diagnostic efficacy of DR(inner VD; outer VD; full VD; outer PD; full PD).CONCLUSION:The outer VD in the 6 mm×6 mm window can enhance the efficacy of the traditional DR diagnostic model. Meanwhile, compared with the 3 mm×3 mm window, the microvascular parameters in the 6 mm× 6 mm window focusing on DN patients can be more sensitive to diagnosing the occurrence of DR.
3.Differential Analysis of Heart Rate Variability in Repeated Continuous Performance Tests Among Healthy Young Men
Chung-Chih HSU ; Tien-Yu CHEN ; Jia-Yi LI ; Terry B. J. KUO ; Cheryl C. H. YANG
Psychiatry Investigation 2025;22(2):148-155
Objective:
Executive function correlates with the parasympathetic nervous system (PNS) based on static heart rate variability (HRV) measurements. Our study advances this understanding by employing dynamic assessments of the PNS to explore and quantify its relationship with inhibitory control (IC).
Methods:
We recruited 31 men aged 20–35 years. We monitored their electrocardiogram (ECG) signals during the administration of the Conners’ Continuous Performance Test-II (CCPT-II) on a weekly basis over 2 weeks. HRV analysis was performed on ECG-derived RR intervals using 5-minute windows, each overlapping for the next 4 minutes to establish 1-minute intervals. For each time window, the HRV metrics extracted were: mean RR intervals, standard deviation of NN intervals (SDNN), low-frequency power with logarithm (lnLF), and high-frequency power with logarithm (lnHF). Each value was correlated with detectability and compared to the corresponding baseline value at t0.
Results:
Compared with the baseline level, SDNN and lnLF showed marked decreases during CCPT-II. The mean values of HRV showed significant correlation with d’, including mean SDNN (R=0.474, p=0.012), mean lnLF (R=0.390, p=0.045), and mean lnHF (R=0.400, p=0.032). In the 14th time window, the significant correlations included SDNN (R=0.578, p=0.002), lnLF (R=0.493, p=0.012), and lnHF (R=0.432, p=0.031). Significant correlation between d’ and HRV parameters emerged only during the initial CCPT-II.
Conclusion
A significant correlation between PNS and IC was observed in the first session alone. The IC in the repeated CCPT-II needs to consider the broader neural network.
4.Comparison of Logistic Regression and Machine Learning Approaches in Predicting Depressive Symptoms: A National-Based Study
Xing-Xuan DONG ; Jian-Hua LIU ; Tian-Yang ZHANG ; Chen-Wei PAN ; Chun-Hua ZHAO ; Yi-Bo WU ; Dan-Dan CHEN
Psychiatry Investigation 2025;22(3):267-278
Objective:
Machine learning (ML) has been reported to have better predictive capability than traditional statistical techniques. The aim of this study was to assess the efficacy of ML algorithms and logistic regression (LR) for predicting depressive symptoms during the COVID-19 pandemic.
Methods:
Analyses were carried out in a national cross-sectional study involving 21,916 participants. The ML algorithms in this study included random forest (RF), support vector machine (SVM), neural network (NN), and gradient boosting machine (GBM) methods. The performance indices were sensitivity, specificity, accuracy, precision, F1-score, and area under the receiver operating characteristic curve (AUC).
Results:
LR and NN had the best performance in terms of AUCs. The risk of overfitting was found to be negligible for most ML models except for RF, and GBM obtained the highest sensitivity, specificity, accuracy, precision, and F1-score. Therefore, LR, NN, and GBM models ranked among the best models.
Conclusion
Compared with ML models, LR model performed comparably to ML models in predicting depressive symptoms and identifying potential risk factors while also exhibiting a lower risk of overfitting.
5.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
6.Finite element analysis of three internal fixation modalities for treatment of Pauwels type Ⅲ femoral neck fractures under different loading conditions
Zhenggang LI ; Xuehong SHANG ; Zhang WU ; Hong LI ; Chaojun SUN ; Huadong CHEN ; Zhe SUN ; Yi YANG
Chinese Journal of Tissue Engineering Research 2025;29(3):455-463
BACKGROUND:There is still no consensus on the optimal internal fixation for the treatment of Pauwels Ⅲ femoral neck fracture,and most of the related finite element analyses have been performed using a single simplified loading condition,and the biomechanical properties of commonly used internal fixation devices need to be further investigated. OBJECTIVE:To analyze the biomechanical characteristics of Pauwels Ⅲ femoral neck fractures treated with cannulated compression screw,dynamic hip screw,and femoral neck system by finite element method under different loading conditions of single-leg standing loads and sideways fall loads. METHODS:The DICOM data of healthy adult femur were obtained by CT scanning,imported into Mimics 15.0 software to obtain the rough model of bone tissue.The data exported from Mimics were optimized by Geomagics software,and then three internal fixation models were built and assembled with the femur model according to the parameters of the clinical application of the cannulated compression screw,dynamic hip screw,and femoral neck system by using Pro/E software.Finally,the three internal fixation models were imported into Ansys software for loading and calculation to analyze the stress distribution and displacement of the femur and the internal fixation under different working conditions of single-leg standing loads and sideways fall loads,as well as the stress characteristics of the calcar femorale and Ward's triangle. RESULTS AND CONCLUSION:(1)Under the single-leg standing load and the sideways fall load,the proximal femoral stress of the three internal fixation models was mainly distributed above the fracture end of the femoral neck.The peak stress of the proximal femoral end,fracture end,Ward triangle,and calcar femorale of the three internal fixation models were the smallest in the femoral neck system model and the largest in the cannulated compression screw model.(2)Under the single-leg standing load and the sideways fall load,the peak displacement of the proximal femur of the three internal fixation models was all located at the top of the femoral head,and the peak displacement was the smallest in the femoral neck system model and the largest in the cannulated compression screw model.(3)The peak displacement of the three internal fixation models was all located at the top of the internal fixation device under the single-leg standing and sideways fall loading conditions,and the peak displacement values were the smallest in the femoral neck system internal fixation model and the largest in the cannulated compression screw internal fixation model.(4)The internal fixation stress of the three internal fixation models was mainly distributed in the area near the fracture end of the internal fixation device under the single-leg standing and sideways fall loads,and the peak value of internal fixation stress was the smallest in the femoral neck system model and the largest in the cannulated compression screw model.(5)These results suggest that the mechanical stability of the femoral neck system is the best,but there may be a risk of stress shielding of the fracture end and calcar femorale.The stress of the internal fixation device of the femoral neck system is more dispersed,and the risk of internal fixation break is lower.
7.Study on accumulation of polysaccharide and steroid components in Polyporus umbellatus infected by Armillaria spp.
Ming-shu YANG ; Yi-fei YIN ; Juan CHEN ; Bing LI ; Meng-yan HOU ; Chun-yan LENG ; Yong-mei XING ; Shun-xing GUO
Acta Pharmaceutica Sinica 2025;60(1):232-238
In view of the few studies on the influence of
8.Network pharmacology-based mechanism of combined leech and bear bile on hepatobiliary diseases
Chen GAO ; Yu-shi GUO ; Xin-yi GUO ; Ling-zhi ZHANG ; Guo-hua YANG ; Yu-sheng YANG ; Tao MA ; Hua SUN
Acta Pharmaceutica Sinica 2025;60(1):105-116
In order to explore the possible role and molecular mechanism of the combined action of leech and bear bile in liver and gallbladder diseases, this study first used network pharmacology methods to screen the components and targets of leech and bear bile, as well as the related target genes of liver and gallbladder diseases. The selected key genes were subjected to interaction network and GO/KEGG enrichment analysis. Then, using sodium oleate induced HepG2 cell lipid deposition model and
9.Structural and Spatial Analysis of The Recognition Relationship Between Influenza A Virus Neuraminidase Antigenic Epitopes and Antibodies
Zheng ZHU ; Zheng-Shan CHEN ; Guan-Ying ZHANG ; Ting FANG ; Pu FAN ; Lei BI ; Yue CUI ; Ze-Ya LI ; Chun-Yi SU ; Xiang-Yang CHI ; Chang-Ming YU
Progress in Biochemistry and Biophysics 2025;52(4):957-969
ObjectiveThis study leverages structural data from antigen-antibody complexes of the influenza A virus neuraminidase (NA) protein to investigate the spatial recognition relationship between the antigenic epitopes and antibody paratopes. MethodsStructural data on NA protein antigen-antibody complexes were comprehensively collected from the SAbDab database, and processed to obtain the amino acid sequences and spatial distribution information on antigenic epitopes and corresponding antibody paratopes. Statistical analysis was conducted on the antibody sequences, frequency of use of genes, amino acid preferences, and the lengths of complementarity determining regions (CDR). Epitope hotspots for antibody binding were analyzed, and the spatial structural similarity of antibody paratopes was calculated and subjected to clustering, which allowed for a comprehensively exploration of the spatial recognition relationship between antigenic epitopes and antibodies. The specificity of antibodies targeting different antigenic epitope clusters was further validated through bio-layer interferometry (BLI) experiments. ResultsThe collected data revealed that the antigen-antibody complex structure data of influenza A virus NA protein in SAbDab database were mainly from H3N2, H7N9 and H1N1 subtypes. The hotspot regions of antigen epitopes were primarily located around the catalytic active site. The antibodies used for structural analysis were primarily derived from human and murine sources. Among murine antibodies, the most frequently used V-J gene combination was IGHV1-12*01/IGHJ2*01, while for human antibodies, the most common combination was IGHV1-69*01/IGHJ6*01. There were significant differences in the lengths and usage preferences of heavy chain CDR amino acids between antibodies that bind within the catalytic active site and those that bind to regions outside the catalytic active site. The results revealed that structurally similar antibodies could recognize the same epitopes, indicating a specific spatial recognition between antibody and antigen epitopes. Structural overlap in the binding regions was observed for antibodies with similar paratope structures, and the competitive binding of these antibodies to the epitope was confirmed through BLI experiments. ConclusionThe antigen epitopes of NA protein mainly ditributed around the catalytic active site and its surrounding loops. Spatial complementarity and electrostatic interactions play crucial roles in the recognition and binding of antibodies to antigenic epitopes in the catalytic region. There existed a spatial recognition relationship between antigens and antibodies that was independent of the uniqueness of antibody sequences, which means that antibodies with different sequences could potentially form similar local spatial structures and recognize the same epitopes.
10.Research on The Construction and Application of Multiple Fluorescence Amplification System for Three Kinds of Stains
Yi-Fan BAI ; He-Miao ZHAO ; Jing CHEN ; Hong-Di LIU ; Rui-Qin YANG ; Chong WANG
Progress in Biochemistry and Biophysics 2025;52(4):982-994
ObjectiveA multiplex amplification system was constructed based on the capillary electrophoresis platform for simultaneous detection of saliva, semen, and vaginal secretions using tissue-specific RNA markers. The aim of this study is to identify the tissue origin of suspicious body fluid stains found at crime scenes and determine whether the body fluid stains at the crime scene are one or several types among saliva, semen, and vaginal secretions. MethodsThirty saliva samples, forty semen samples, and forty vaginal secretion samples (half from 2015 and half from 2024) were collected from healthy adult volunteers. Through primer designing, system formulation, and PCR condition optimization, a multiplex fluorescent amplification system was constructed. The specificity, sensitivity, and detection ability for mixed samples of this system were investigated, and it was tested using real crime scene materials. In the primer design stage, to reduce the requirements for RNA template quality, the amplification products were set within 80-300 bp. In the system formulation stage, dominant and subordinate primers were mainly considered. By reducing the concentration of dominant primers and increasing that of subordinate primers, a capillary electrophoresis spectrum with an appropriate peak height ratio was finally obtained. Additionally, gradient experiments were designed to adjust the concentrations of PCR reagents and PCR amplification conditions, and multiple versions of DNA amplification enzymes were optimized to achieve the best experimental results. ResultsThrough statistical analysis, there was no significant difference in the capillary electrophoresis of the 3 types of body fluid samples from the two years (2015 and 2024), demonstrating that the sample preservation method in this study can preserve samples for a relatively long time. The composite amplification system constructed in this study exhibited high specificity for all 3 types of body fluid, with no cross-reactions between the markers of each type of body fluid. The minimum detection thresholds for the 3 types of body fluid reached 0.002 9, 0.001 5, and 0.42 mg/L, respectively. This system also had a high degree of discrimination for mixed samples, especially for semen-saliva mixtures, where each body fluid marker could still be successfully detected when the concentration ratio of semen to saliva was 100:1. Meanwhile, in the two actual cases presented in this article, the application of this composite amplification system performed outstandingly. ConclusionThe composite amplification detection system constructed in this study can achieve the correct screening of saliva, semen, and vaginal secretions, overcoming the problems such as low specificity and sensitivity of marker tests and unbalanced RFU values of each marker in previous studies. The specificity and sensitivity meet the practical work requirements, and the operation is simple. It provides an analytical and identification method for body fluid stains in actual case and is applicable to the identification of the tissue origin of biological evidence at crime scenes involving sexual assault, indecent assault, and other criminal acts. In the future, more types of body fluid markers will be screened to expand the types of body fluids detected by the system, and body fluid-specific cSNP and cInDel genetic markers will be introduced to infer the sources (individuals and types) of mixed and complex stains more accurately.

Result Analysis
Print
Save
E-mail