1.Establishment of a Multiplex Detection Method for Common Bacteria in Blood Based on Human Mannan-Binding Lectin Protein-Conjugated Magnetic Bead Enrichment Combined with Recombinase-Aided PCR Technology
Jin Zi ZHAO ; Ping Xiao CHEN ; Wei Shao HUA ; Yu Feng LI ; Meng ZHAO ; Hao Chen XING ; Jie WANG ; Yu Feng TIAN ; Qing Rui ZHANG ; Na Xiao LYU ; Qiang Zhi HAN ; Xin Yu WANG ; Yi Hong LI ; Xin Xin SHEN ; Jun Xue MA ; Qing Yan TIE
Biomedical and Environmental Sciences 2024;37(4):387-398
Objective Recombinase-aided polymerase chain reaction(RAP)is a sensitive,single-tube,two-stage nucleic acid amplification method.This study aimed to develop an assay that can be used for the early diagnosis of three types of bacteremia caused by Staphylococcus aureus(SA),Pseudomonas aeruginosa(PA),and Acinetobacter baumannii(AB)in the bloodstream based on recombinant human mannan-binding lectin protein(M1 protein)-conjugated magnetic bead(M1 bead)enrichment of pathogens combined with RAP. Methods Recombinant plasmids were used to evaluate the assay sensitivity.Common blood influenza bacteria were used for the specific detection.Simulated and clinical plasma samples were enriched with M1 beads and then subjected to multiple recombinase-aided PCR(M-RAP)and quantitative PCR(qPCR)assays.Kappa analysis was used to evaluate the consistency between the two assays. Results The M-RAP method had sensitivity rates of 1,10,and 1 copies/μL for the detection of SA,PA,and AB plasmids,respectively,without cross-reaction to other bacterial species.The M-RAP assay obtained results for<10 CFU/mL pathogens in the blood within 4 h,with higher sensitivity than qPCR.M-RAP and qPCR for SA,PA,and AB yielded Kappa values of 0.839,0.815,and 0.856,respectively(P<0.05). Conclusion An M-RAP assay for SA,PA,and AB in blood samples utilizing M1 bead enrichment has been developed and can be potentially used for the early detection of bacteremia.
2.Development of prefilled portable intelligent venous transfusion pump
Zhu-Qiang CHENG ; Peng-Yun JI ; Yong-Fen ZENG ; Min YANG ; Yi JIN ; Hong-Jun LIU
Chinese Medical Equipment Journal 2024;45(5):111-114
Objective To develop a prefilled portable intelligent intravenous transfusion pump to facilitate fast and convenient fluid pumping during emergency treatment and casualty transport.Methods The prefilled portable intelligent venous transfusion pump was composed of a driver module,a pump module,a human-machine interface,a prefilled sterile infusion bag and a pump catheter.The driver module adopted integrated design and applied a high-voltage DC-AC converter to driving the piezoelectric pump used as the power source of the pump module;the human-machine interface consisted of several keys for on/off,rate adjustment,switching and confirmation;the prefilled sterile infusion bag was made of medical-grade polypropylene,and the pump catheter was made of medical silicone rubber.Results The transfusion pump developed could be worn on the casualty limb and did not require height difference for intravenous infusion,which enhanced intravenous drug delivery in portability,reliability and intelligence.Conclusion The transfusion pump developed gains advantages in low size,weight and easy operation,and thus is worthy promoting for venous transfusion in battlefield conditions and field emergency environments.[Chinese Medical Equipment Journal,2024,45(5):111-114]
3.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
4.Clinical application of fluorescence laparoscopy in living donor left lateral sectionectomy for pediatric liver transplantation
Yi LUO ; Jianjun ZHU ; Yuting JIN ; Dongwei XU ; Qiang XIA
Chinese Journal of Organ Transplantation 2024;45(5):323-328
Objective:To compare the clinical efficacy of fluorescent laparoscopy versus conventional laparoscopy for living-donor hepatectomy and explore the application value of fluorescent cholangiography in pediatric living donor liver transplantation (LT) using left lateral lobe.Methods:From October 2016 to August 2023, retrospective analysis was conducted for the relevant clinical data from 302 recipients of laparoscopic left lateral lobe donor hepatectomy. There were 90 cases in conventional laparoscopy group and 212 cases in fluorescent laparoscopy group. After propensity score matching (PSM), 88 patients were enrolled into each group. The perioperative data such as operative duration, donor liver thermal ischemic time, number of graft bile duct openings, liver function parameters and complication rates at Day 1/3 postoperation of donors and recipients were compared between two groups. SPSS 27.0 statistical software was utilized for analysis. Independent sample t, Mann-Whitney U and chisquare tests were utilized for examining the inter-group differences. Results:In fluorescent laparoscopy group, the proportion of grafts with a single open left hepatic duct was 84.1 %(74/88) versus 70.5% (62/88) in conventional laparoscopy group with statistically significant difference ( P=0.031). No statistically significant inter-group differences existed in postoperative liver function recovery or short-term postoperative complications ( P>0.05 ). No statistically significant inter-group differences existed in short-term postoperative liver function recovery or hospitalization length ( P> 0.05). In terms of biliary complications, fluorescent laparoscopy group had no biliary complications while the incidence of biliary complications was 3.4% (3/88) in conventional laparoscopy group. However, inter-group difference was statistically insignificant ( P>0.05 ) . Conclusions:Living-donor LT using left lateral lobe under fluorescent laparoscopy may enhance the surgical safety for both donors and recipients.
5.Association of Measures of Glucose Metabolism with Colorectal Cancer Risk in Older Chinese: A 13-Year Follow-up of the Guangzhou Biobank Cohort Study-Cardiovascular Disease Substudy and Meta-Analysis
Shu Yi WANG ; Wei Sen ZHANG ; Chao Qiang JIANG ; Ya Li JIN ; Tong ZHU ; Feng ZHU ; Lin XU
Diabetes & Metabolism Journal 2024;48(1):134-145
Background:
Abnormal glucose metabolism is a risk factor for colorectal cancer (CRC). However, association of glycosylated hemoglobin (HbA1c) with CRC risk remains under-reported. We examined the association between glycemic indicators (HbA1c, fasting plasma glucose, fasting insulin, 2-hour glucose, 2-hour insulin, and homeostasis model of risk assessment-insulin resistance index) and CRC risk using prospective analysis and meta-analysis.
Methods:
Participants (n=1,915) from the Guangzhou Biobank Cohort Study-Cardiovascular Disease Substudy were included. CRC events were identified through record linkage. Cox regression was used to assess the associations of glycemic indicators with CRC risk. A meta-analysis was performed to investigate the association between HbA1c and CRC risk.
Results:
During an average of 12.9 years follow-up (standard deviation, 2.8), 42 incident CRC cases occurred. After adjusting for potential confounders, the hazard ratio (95% confidence interval [CI]) of CRC for per % increment in HbA1c was 1.28 (95% CI, 1.01 to 1.63) in overall population, 1.51 (95% CI, 1.13 to 2.02) in women and 1.06 (95% CI, 0.68 to 1.68) in men. No significant association of other measures of glycemic indicators and baseline diabetes with CRC risk was found. Meta-analyses of 523,857 participants including our results showed that per % increment of HbA1c was associated with 13% higher risk of CRC, with the pooled risk ratio being 1.13 (95% CI, 1.01 to 1.27). Subgroupanalyses found stronger associations in women, colon cancer, Asians, and case-control studies.
Conclusion
Higher HbA1c was a significant predictor of CRC in the general population. Our findings shed light on the pathology of glucose metabolism and CRC, which warrants more in-depth investigation.
6.Ethnic Differences in the Safety and Efficacy of Tenecteplase Versus Alteplase for Acute Ischemic Stroke: A Systematic Review and Meta-Analysis
Jin Hean KOH ; Claire Yi Jia LIM ; Lucas Tze Peng TAN ; Ching-Hui SIA ; Kian Keong POH ; Vijay Kumar SHARMA ; Leonard Leong Litt YEO ; Andrew Fu Wah HO ; Teddy WU ; William Kok-Fai KONG ; Benjamin Yong Qiang TAN
Journal of Stroke 2024;26(3):371-390
Background:
and Purpose Tenecteplase is a thrombolytic agent with pharmacological advantages over alteplase and has been shown to be noninferior to alteplase for acute ischemic stroke in randomized trials. However, evidence pertaining to the safety and efficacy of tenecteplase in patients from different ethnic groups is lacking. The aim of this systematic review and metaanalysis was to investigate ethnicity-specific differences in the safety and efficacy of tenecteplase versus alteplase in patients with acute ischemic stroke.
Methods:
Following an International Prospective Register of Systematic Reviews (PROSPERO)- registered protocol (CRD42023475038), three authors conducted a systematic review of the PubMed/MEDLINE, Embase, Cochrane Library, and CINAHL databases for articles comparing the use of tenecteplase with any thrombolytic agent in patients with acute ischemic stroke up to November 20, 2023. The certainty of evidence was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework. Two independent authors extracted data onto a standardized data collection sheet. A pairwise meta-analysis was conducted in risk ratios (RR).
Results:
From 34 studies (59,601 participants), the rate of complete recanalization was significantly higher (P<0.01) in Asian (RR: 1.91, 95% confidence interval [CI]: 1.30 to 2.80) versus Caucasian patients (RR: 0.99, 95% CI: 0.87 to 1.14). However, Asian patients (RR: 1.18, 95% CI: 0.87 to 1.62) had significantly higher (P=0.01) rates of mortality compared with Caucasian patients (RR: 1.10, 95% CI: 1.00 to 1.22). Caucasian patients were also more likely to attain a modified Rankin Scale (mRS) score of 0 to 2 at follow-up (RR: 1.14, 95% CI, 1.10 to 1.19) compared with Asian (RR: 1.00, 95% CI, 0.95 to 1.05) patients. There was no significant difference in the rate of symptomatic intracranial hemorrhage (P=0.20) and any intracranial hemorrhage (P=0.83) between Asian and Caucasian patients.
Conclusion
Tenecteplase was associated with significantly higher rates of complete recanalization in Asian patients compared with Caucasian patients. However, tenecteplase was associated with higher rates of mortality and lower rates of mRS 0 to 2 in Asian patients compared with Caucasian patients. It may be beneficial to study the variations in response to tenecteplase among patients of different ethnic groups in large prospective cohort studies.
7.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
8.Research progress of tunneling nanotube in bone biology.
Jin Biao QIANG ; Xiao Ling WANG ; Xue Ying BAI ; Xin Yi FAN ; Ce SHI
Chinese Journal of Stomatology 2023;58(1):86-91
Tunneling nanotube (TNT) is a newly discovered communication mode between animal cells in recent years, which have important physiological and pathological significance. However, the role of TNT in bone biology is still unclear. At present, there are many reports about tunneling nanotubes in bone marrow mesenchymal stem cells, osteoclast precursor cells, osteoblasts and immune cells. This review describes the research advances of TNT and its research progress in bone biology. It looks forward to the research direction of TNT in oral and maxillofacial bone development and bone biology, to provide new strategies for the maintenance of bone homeostasis and the treatment of bone diseases.
Animals
;
Bone and Bones
;
Nanotubes
;
Osteoclasts
;
Biology
;
Cell Communication/physiology*
9.High-throughput screening of SARS-CoV-2 main and papain-like protease inhibitors.
Yi ZANG ; Mingbo SU ; Qingxing WANG ; Xi CHENG ; Wenru ZHANG ; Yao ZHAO ; Tong CHEN ; Yingyan JIANG ; Qiang SHEN ; Juan DU ; Qiuxiang TAN ; Peipei WANG ; Lixin GAO ; Zhenming JIN ; Mengmeng ZHANG ; Cong LI ; Ya ZHU ; Bo FENG ; Bixi TANG ; Han XIE ; Ming-Wei WANG ; Mingyue ZHENG ; Xiaoyan PAN ; Haitao YANG ; Yechun XU ; Beili WU ; Leike ZHANG ; Zihe RAO ; Xiuna YANG ; Hualiang JIANG ; Gengfu XIAO ; Qiang ZHAO ; Jia LI
Protein & Cell 2023;14(1):17-27
The global COVID-19 coronavirus pandemic has infected over 109 million people, leading to over 2 million deaths up to date and still lacking of effective drugs for patient treatment. Here, we screened about 1.8 million small molecules against the main protease (Mpro) and papain like protease (PLpro), two major proteases in severe acute respiratory syndrome-coronavirus 2 genome, and identified 1851Mpro inhibitors and 205 PLpro inhibitors with low nmol/l activity of the best hits. Among these inhibitors, eight small molecules showed dual inhibition effects on both Mpro and PLpro, exhibiting potential as better candidates for COVID-19 treatment. The best inhibitors of each protease were tested in antiviral assay, with over 40% of Mpro inhibitors and over 20% of PLpro inhibitors showing high potency in viral inhibition with low cytotoxicity. The X-ray crystal structure of SARS-CoV-2 Mpro in complex with its potent inhibitor 4a was determined at 1.8 Å resolution. Together with docking assays, our results provide a comprehensive resource for future research on anti-SARS-CoV-2 drug development.
Humans
;
Antiviral Agents/chemistry*
;
COVID-19
;
COVID-19 Drug Treatment
;
High-Throughput Screening Assays
;
Molecular Docking Simulation
;
Protease Inhibitors/chemistry*
;
SARS-CoV-2/enzymology*
;
Viral Nonstructural Proteins
10.Clinical characteristics of 42 children with focal atrial tachycardia originated from the right atrial appendage.
Yi ZHANG ; Xiao Mei LI ; He JIANG ; Yong Qiang JIN ; Mei Ting LI ; Ya Li GU ; Hui Ming ZHOU
Chinese Journal of Pediatrics 2023;61(8):714-718
Objective: To investigate the feature and treatment of atrial tachycardia (AT) originated from right atrial appendage (RAA) in children. Methods: The data of 42 children with AT originated from RAA, who were admitted the First Hospital of Tsinghua University from January 2010 to September 2022 were analyzed retrospectively.The clinical characteristics, treatment and efficacy were analyzed. The children were divided into tachycardia cardiomyopathy group and normal cardiac function group. The differences in the ablation age and the heart rate during AT between two groups were compared by independent sample t-test. Results: Among 42 children, there were 20 males and 22 females. The age of onset was 2.7 (0.6, 5.1) years. Their age at radiofrequency ablation was (6.5±3.6) years, and the weight was (23.4±10.0) kg. Thirty-two children (76%) had sustained AT. The incidence of tachycardia cardiomyopathy was 43% (18/42). Compared to that of the normal cardiac function group, the ablation age and the heart rate at atrial tachycardia of the tachycardia cardiomyopathy group were higher ((8.1±3.8) vs. (5.3±3.1) years, t=-2.63, P=0.012; (173±41) vs. (150±30) beats per minute, t=-2.05, P=0.047. Thirty-eight children (90%) responded poorly to two or more antiarrhythmic drugs. The immediate success rate of radiofrequency ablation (RFCA) was 57% (24/42), and the AT recurrence rate was 17% (4/24). Twenty-two children underwent RAA resection, and their AT were all converted to sinus rhythm after the surgery. During the RAA resection, 10 cases of right atrial appendage aneurysm were found, 9/18 of which failed the RFCA. Conclusions: The AT originated from the RAA in children tend to present with sustained AT, respond poorly to antiarrhythmic drugs, and has a low success rate of RFCA as well as high recurrence rate. Resection of the RAA is a safe and effective complementary treatment.
Male
;
Female
;
Humans
;
Child
;
Atrial Appendage/surgery*
;
Anti-Arrhythmia Agents/therapeutic use*
;
Retrospective Studies
;
Catheter Ablation
;
Tachycardia/surgery*
;
Treatment Outcome
;
Cardiomyopathies

Result Analysis
Print
Save
E-mail