1.Terms Related to The Study of Biomacromolecular Condensates
Ke RUAN ; Xiao-Feng FANG ; Dan LI ; Pi-Long LI ; Yi LIN ; Zheng WANG ; Yun-Yu SHI ; Ming-Jie ZHANG ; Hong ZHANG ; Cong LIU
Progress in Biochemistry and Biophysics 2025;52(4):1027-1035
		                        		
		                        			
		                        			Biomolecular condensates are formed through phase separation of biomacromolecules such as proteins and RNAs. These condensates exhibit liquid-like properties that can futher transition into more stable material states. They form complex internal structures via multivalent weak interactions, enabling precise spatiotemporal regulations. However, the use of inconsistent and non-standardized terminology has become increasingly problematic, hindering academic exchange and the dissemination of scientific knowledge. Therefore, it is necessary to discuss the terminology related to biomolecular condensates in order to clarify concepts, promote interdisciplinary cooperation, enhance research efficiency, and support the healthy development of this field. 
		                        		
		                        		
		                        		
		                        	
3.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
4.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
		                        		
		                        			 Purpose:
		                        			Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations. 
		                        		
		                        			Methods:
		                        			PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale. 
		                        		
		                        			Results:
		                        			Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633). 
		                        		
		                        			Conclusion
		                        			Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.  
		                        		
		                        		
		                        		
		                        	
5.Usefulness of intraoperative choledochoscopy in laparoscopic subtotal cholecystectomy for severe cholecystitis
Rui-Hui ZHANG ; Xiang-Nan WANG ; Yue-Feng MA ; Xue-Qian TANG ; Mei-Ju LIN ; Li-Jun SHI ; Jing-Yi LI ; Hong-Wei ZHANG
Annals of Hepato-Biliary-Pancreatic Surgery 2025;29(2):192-198
		                        		
		                        			
		                        			 Laparoscopic subtotal cholecystectomy (LSC) has been a safe and viable alternative to conversion to laparotomy in cases of severe cholecystitis. The objective of this study is to determine the utility of intraoperative choledochoscopy in LSC for the exploration of the gallbladder, cyst duct, and subsequent stone clearance of the cystic duct in cases of severe cholecystitis. A total of 72 patients diagnosed with severe cholecystitis received choledochoscopy-assisted laparoscopic subtotal cholecystectomy (CALSC). A choledochoscopy was performed to explore the gallbladder cavity and/or cystic duct, and to extract stones using a range of techniques. The clinical records, including the operative records and outcomes, were subjected to analysis. No LSC was converted to open surgery, and no bile duct or vascular injuries were sustained. All stones within the cystic duct were removed by a combination of techniques, including high-frequency needle knife electrotomy, basket, and electrohydraulic lithotripsy. A follow-up examination revealed the absence of residual bile duct stones, with the exception of one common bile duct stone, which was extracted via endoscopic retrograde cholangiopancreatography. In certain special cases, CALSC may prove to be an efficacious treatment for the management of severe cholecystitis. This technique allows for optimal comprehension of the situation within the gallbladder cavity and cystic duct, facilitating the removal of stones from the cystic duct and reducing the residue of the non-functional gallbladder remnant. 
		                        		
		                        		
		                        		
		                        	
7.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
9.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
10.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
		                        		
		                        			 Purpose:
		                        			Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations. 
		                        		
		                        			Methods:
		                        			PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale. 
		                        		
		                        			Results:
		                        			Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633). 
		                        		
		                        			Conclusion
		                        			Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.  
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail