1.Progress in the application of poloxamer in new preparation technology
Xue QI ; Yi CHENG ; Nan LIU ; Zengming WANG ; Hui ZHANG ; Aiping ZHENG ; Dongzhou KANG
China Pharmacy 2025;36(5):630-635
Poloxamer, as a non-ionic surfactant, exhibits a unique triblock [polyethylene oxide-poly (propylene oxide)-polyethylene oxide] structure, which endows it with broad application potential in various fields, including solid dispersion technology, nanotechnology, gel technology, biologics, gene engineering and 3D printing. As a carrier, it enhances the solubility and bioavailability of poorly soluble drugs. In the field of nanotechnology, it serves as a stabilizer etc., enriching preparation methods. In gel technology, its self-assembly behavior and thermosensitive properties facilitate controlled drug release. In biologics, it improves targeting efficiency and reduces side effects. In gene engineering, it enhances delivery efficiency and expression levels. In 3D printing, it provides novel strategies for precise drug release control and the production of high-quality biological products. As a versatile material, poloxamer holds promising prospects in the pharmaceutical field.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Study on the mechanism of berberine in improving diabetes mellitus type 2 combined with metabolic-associated fatty liver disease
Yi LI ; Shuyu KANG ; Qiwen WANG ; Manting HUANG ; Congyan ZENG ; Jun TONG ; Gengting DONG
China Pharmacy 2025;36(16):1975-1980
OBJECTIVE To investigate the potential mechanism of berberine improving diabetes mellitus type 2 (T2DM) combined with metabolic-associated fatty liver disease (MAFLD) by regulating ceramide. METHODS Thirty-two db/db mice with blood glucose levels>11.1 mmol/L (T2DM model) were divided into four groups: model group, berberine low- and high-dose groups [100, 200 mg/(kg·d)] and metformin group [300 mg/(kg·d)], with 8 mice in each group. Additionally, 8 wt/wt mice were selected as the normal control group. Mice in each group were administered the corresponding drug solution or water by gavage once daily for a continuous period of 6 weeks. During the experiment, the body weight of the mice was monitored, and the differences in final body weight were analyzed. After the last administration, the body shape of the mice in each group was observed, and their fasting blood glucose (FBG) and the lipid indicators [total cholesterol (TC), triglyceride (TG), low-density lipoprotein cholesterol (LDL-C), high-density lipoprotein cholesterol (HDL-C)] were measured. Fasting serum insulin (FINS) levels were also measured, and the insulin resistance index HOMA-IR) and insulin sensitivity index (ISI) were calculated. Liver weight, liver index and serum liver function indicators [alanine transaminase (ALT), aspartate transaminase(AST)] were assessed, and hepatic histopathological changes were observed. Additionally, the expression of fatty acid synthesis-related proteins [sterol regulatory element-binding protein 1 (SREBP1), fatty acid synthase (FASN), acetyl-CoA carboxylase 1 (ACC1)] in liver tissue was examined. Serum samples from the normal control group, model group, and berberine high-dose group were collected for non-targeted lipidomics analysis and validation. RESULTS Compared with the model group, the pathological changes, including disordered liver tissue cell arrangement and lipid vacuoles, were significantly improved in the berberine low- and high-dose groups. The significant decreases or down-regulations were observed in body weight in the last week, as well as FBG, TC, TG, and LDL-C levels, HOMA-IR (except for the berberine low-dose group), liver weight, liver index, AST and ALT levels, and protein expressions of SREBP1, FASN and ACC1. Additionally, HDL-C levels, FINS (except for the berberine high-dose group), and ISI (except for the berberine low-dose group) were significantly increased (P<0.05). A total of 21 potential differential metabolites, including multiple types of ceramides, were identified; these metabolites were primarily enriched in sphingolipid metabolism and glycerophospholipid metabolism pathways. Verification experiments confirmed that high-dose berberine significantly reduced the serum content of ceramide in model mice (P<0.05). CONCLUSIONS Berberine reduces insulin resistance, improves liver damage and lipid accumulation in the T2DM combined with MAFLD mice, and these effects may be related to the reduction of ceramide content.
8.Triglyceride-glucose index and homocysteine in association with the risk of stroke in middle-aged and elderly diabetic populations
Xiaolin LIU ; Jin ZHANG ; Zhitao LI ; Xiaonan WANG ; Juzhong KE ; Kang WU ; Hua QIU ; Qingping LIU ; Jiahui SONG ; Jiaojiao GAO ; Yang LIU ; Qian XU ; Yi ZHOU ; Xiaonan RUAN
Shanghai Journal of Preventive Medicine 2025;37(6):515-520
ObjectiveTo investigate the triglyceride-glucose (TyG) index and the level of serum homocysteine (Hcy) in association with the incidence of stroke in type 2 diabetes mellitus (T2DM) patients. MethodsBased on the chronic disease risk factor surveillance cohort in Pudong New Area, Shanghai, excluding those with stroke in baseline survey, T2DM patients who joined the cohort from January 2016 to October 2020 were selected as the research subjects. During the follow-up period, a total of 318 new-onset ischemic stroke patients were selected as the case group, and a total of 318 individuals matched by gender without stroke were selected as the control group. The Cox proportional hazards regression model was used to adjust for confounding factors and explore the serum TyG index and the Hcy biochemical indicator in association with the risk of stroke. ResultsThe Cox proportional hazards regression results showed that after adjusting for confounding factors, the risk of stroke in T2DM patients with 10 μmol·L⁻¹
9.Real-time Analysis of Organic Composition of Oral and Nasal Breath Air by High Resolution Mass Spectrometry
Kang-Yi WANG ; Chen TAO ; Xin LUO ; Zhi-Feng TANG ; Te BAI ; Hang LI ; Li-Gang HU ; Wei ZHANG ; Xue LI
Chinese Journal of Analytical Chemistry 2024;52(1):72-79,中插14-中插37
Human exhaled breath has great application prospects,e.g.,monitoring pharmacokinetics,disease diagnosis,due to its advantages such as non-invasive and high-frequency sampling.Breath samples can be collected from the oral and nasal cavity.However,the oral and nasal environment affect the chemical composition of breath sample.Therefore,the investigation on the chemical composition of mouth-exhaled breath and nose-exhaled breath is crucial for selection of appropriate sampling strategy for individual studies.In this work,secondary electrospray ionization-high resolution mass spectrometry(SESI-HRMS)was applied to analysis of respiratory metabolomics in real time.A quantitative analysis approach was established for 9 kinds of volatile organic compounds(VOCs)e.g.2-butanone,2-pentanone,ethyl acetate,methyl methacrylate,toluene,styrene,mesitylene,isoprene and limonene.The limit of detection was 2.3?240.8 ng/m3.The intra-day(n=6)and inter-day(n=18)relative standard deviations were 0.6%?4.6%and 4.3%?12.2%,respectively.Nine healthy subjects were recruited to investigate the chemical composition of mouth-exhaled and nose-exhaled breath.The results showed the good performance in quantitative analysis of 9 VOCs in breath air.It was found that the number of unique component(m/z)detected in mouth-exhaled breath(167)was 2.2 times greater than that detected in nose-exhaled breath(76),which might result from the complex environment in oral cavity.The signal intensity of commun component(163)was significantly different between mouth-exhaled breath and nose-exhaled breath.Additionally,the elemental composition analysis showed that the proportion of polar compounds detected in nose-exhaled breath was higher than that in mouth-exhaled breath.This study demonstrated that there was significant differences in the chemical composition between mouth-exhaled and nose-exhaled breath,which provided a theoretical basis for selection of exhalation mode.
10.The Genetic Polymorphism and Structural Analysis of 47 Microhaplotypes in a Jiangsu Changshu Chinese Han Population
Kun-Peng PAN ; Yao-Sen FENG ; Wen-Shuai YU ; Zong-Wei LIU ; Yi-Ren YAO ; Jie ZHAO ; Ke-Lai KANG ; Chi ZHANG ; Le WANG ; Jian WU
Progress in Biochemistry and Biophysics 2024;51(2):423-434
ObjectiveTo investigate the genetic polymorphism and structure of 47 autosomal microhaplotypes in the Han population in Changshu City, Jiangsu Province, and to evaluate the forensic efficiencies and forensic parameters. MethodsThe DNA library of unrelated individual samples was prepared according to MHSeqTyper47 kit manual and sequenced on the MiSeq FGx platform. Microhaplotype genotyping and sequencing depth statistics were processed using MHTyper. The genetic information of samples was then evaluated. The fixation index and genetic distance between the Jiangsu Changshu population and the reference populations in the 1000 Genomes Project phase 3 (1KG) were calculated, and forensic parameters were evaluated. ResultsThe fixation index and genetic distance between the Han population in Changshu, Jiangsu, and the CHB (Han Chinese in Beijing, China) reference population in 1KG were the lowest. The effective allele number (Ae) of each locus is also the closest between the two populations. The combined matching probability (CMP) of the Changshu Han population is close to the 5 populations of the East Asian reference super-population in 1KG, which is 1.25×10-36, and the combined probability of exclusion reached 0.999 999 999 964 1. ConclusionThis study reported the genetic polymorphism and allele frequency of 47 microhaplotypes in a Han population in Changshu City, Jiangsu Province. This information provides a data basis for 47 microhaplotypes in forensic applications. In addition, the polymorphism differences between the 1KG reference population and the Han population in Changshu, Jiangsu were compared, and the genetic structure of 47 microhaplotypes in the Han population in Changshu, Jiangsu was revealed. In general, the reference data of the East Asian super-population in 1KG is more in line with the genetic characteristics of Han population in Changshu, Jiangsu.

Result Analysis
Print
Save
E-mail