1.Usefulness of intraoperative choledochoscopy in laparoscopic subtotal cholecystectomy for severe cholecystitis
Rui-Hui ZHANG ; Xiang-Nan WANG ; Yue-Feng MA ; Xue-Qian TANG ; Mei-Ju LIN ; Li-Jun SHI ; Jing-Yi LI ; Hong-Wei ZHANG
Annals of Hepato-Biliary-Pancreatic Surgery 2025;29(2):192-198
Laparoscopic subtotal cholecystectomy (LSC) has been a safe and viable alternative to conversion to laparotomy in cases of severe cholecystitis. The objective of this study is to determine the utility of intraoperative choledochoscopy in LSC for the exploration of the gallbladder, cyst duct, and subsequent stone clearance of the cystic duct in cases of severe cholecystitis. A total of 72 patients diagnosed with severe cholecystitis received choledochoscopy-assisted laparoscopic subtotal cholecystectomy (CALSC). A choledochoscopy was performed to explore the gallbladder cavity and/or cystic duct, and to extract stones using a range of techniques. The clinical records, including the operative records and outcomes, were subjected to analysis. No LSC was converted to open surgery, and no bile duct or vascular injuries were sustained. All stones within the cystic duct were removed by a combination of techniques, including high-frequency needle knife electrotomy, basket, and electrohydraulic lithotripsy. A follow-up examination revealed the absence of residual bile duct stones, with the exception of one common bile duct stone, which was extracted via endoscopic retrograde cholangiopancreatography. In certain special cases, CALSC may prove to be an efficacious treatment for the management of severe cholecystitis. This technique allows for optimal comprehension of the situation within the gallbladder cavity and cystic duct, facilitating the removal of stones from the cystic duct and reducing the residue of the non-functional gallbladder remnant.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Ideas of Traditional Chinese Medicine Treatment of Pancreatic Endocrine and Exocrine Co-Morbidities from the Attributes of Zang-Fu Organs of Pancreas
Yulin LENG ; Jiacheng YIN ; Xianglong LI ; Jiahong ZHANG ; Yi SU ; Hong GAO ; Chunguang XIE ; Xiaoxu FU
Journal of Traditional Chinese Medicine 2025;66(2):145-149
Based on advancements in modern medical research regarding the intricate connection between the endocrine and exocrine functions of the pancreas, as well as the relationship between pancreatic functions and traditional Chinese medicine (TCM) spleen system, this paper discussed the categorization of the pancreas. It is proposed that the pancreas is neither a true zang organ nor a fu organ, but possessed the attributes of an extraordinary fu-organ and can be classified under the spleen. The spleen governs transportation and transformation, ascent of the clear and dispersion of essence, which encompasses the endocrine and exocrine functions, and pancreatic enzymes and glucose-regulating hormones form the material basis for the spleen's function of dispersing essence. Diseases of the pancreas exhibit characteristics of both zang-organ deficiency and fu-organ excess, so treatment should simultaneously supplement zang-organ disease and regulate fu-organ disease when pancreas showing endocrine and exocrine co-morbidities, with focus on restoring the pancreas (spleen)'s dispersing essence function. Therapeutic strategies include supplementing spleen qi, nourishing spleen yin to strengthen spleen earth, unblocking spleen collaterals, raising spleen yang, and removing spleen turbidity to support the spleen's dispersing essence function, so as to replenish the essential qi of zang-fu organs, ensure their distribution throughout the body, and improve the endocrine and exocrine functions of the pancreas.
4.Exploring Vascular Recruitment in Tracheobronchial Adenoid Cystic Carcinoma from Perspective of Abnormal Collateral
Jun TENG ; Lei LI ; Junyan XIA ; Yi LUO ; Qinyan HONG ; Shuiping CHEN ; Hongwu WANG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(6):260-269
Tracheobronchial adenoid cystic carcinoma (TACC) is a low-grade malignant tumor originating from the airway mucosa. Despite its slow progression,it is characterized by high invasiveness,frequent recurrence,and a strong tendency for metastasis. Preclinical studies have shown that vascular-targeted therapy holds significant potential. However,an effective systemic treatment for TACC has not been established yet. This study explored TACC from the perspective of "Feiji" in traditional Chinese medicine (TCM) as the starting point. It deeply investigated the mechanisms of abnormal collaterals and tumor vascular recruitment and further elaborated on the theoretical connection between abnormal collaterals and tumor vascular recruitment. Firstly,collateral hyperactivity led to disordered and erratic pulmonary collaterals. Their abnormal structures were similar to the disorderly and tortuous nature of tumor (pseudo)angiogenesis. This resulted in imbalances in the functions of circulation,perfusion,and reverse injection of the pulmonary collaterals,and then led to unrestrained collateral dysfunction and the accumulation of pathogenic factors. Secondly,the remodeling of the extracellular matrix (ECM) and epithelial-mesenchymal transition (EMT) in TACC were critical processes in vascular co-option (VCO),representing the micro-level manifestation of the displacement of nutrient and defense. During this process,ECM remodeling made TACC cells more likely to hijack normal blood vessels,creating a complex vascular microenvironment conducive to tumor growth. In terms of treatment,this study proposed a TCM strategy of "regulating collaterals to expel pathogenic factors and nourishing collaterals to strengthen the healthy Qi",and listed potential TCM. These were intended to regulate the Qi and blood in the collaterals,repair the functions of abnormal collaterals,and intervene in the vascular recruitment process of TACC. Future research should focus on improving the TCM clinical syndrome characteristics of TACC. Through modern molecular biology techniques,it is necessary to deeply analyze the micro-level pattern of vascular recruitment in TACC. This would enrich the understanding of the profound connection between abnormal collaterals and tumor vascular recruitment,providing empirical evidence for TCM-targeted therapies for vascular recruitment in TACC.
5.Enzyme-directed Immobilization Strategies for Biosensor Applications
Xing-Bao WANG ; Yao-Hong MA ; Yun-Long XUE ; Xiao-Zhen HUANG ; Yue SHAO ; Yi YU ; Bing-Lian WANG ; Qing-Ai LIU ; Li-He ZHANG ; Wei-Li GONG
Progress in Biochemistry and Biophysics 2025;52(2):374-394
Immobilized enzyme-based enzyme electrode biosensors, characterized by high sensitivity and efficiency, strong specificity, and compact size, demonstrate broad application prospects in life science research, disease diagnosis and monitoring, etc. Immobilization of enzyme is a critical step in determining the performance (stability, sensitivity, and reproducibility) of the biosensors. Random immobilization (physical adsorption, covalent cross-linking, etc.) can easily bring about problems, such as decreased enzyme activity and relatively unstable immobilization. Whereas, directional immobilization utilizing amino acid residue mutation, affinity peptide fusion, or nucleotide-specific binding to restrict the orientation of the enzymes provides new possibilities to solve the problems caused by random immobilization. In this paper, the principles, advantages and disadvantages and the application progress of enzyme electrode biosensors of different directional immobilization strategies for enzyme molecular sensing elements by specific amino acids (lysine, histidine, cysteine, unnatural amino acid) with functional groups introduced based on site-specific mutation, affinity peptides (gold binding peptides, carbon binding peptides, carbohydrate binding domains) fused through genetic engineering, and specific binding between nucleotides and target enzymes (proteins) were reviewed, and the application fields, advantages and limitations of various immobilized enzyme interface characterization techniques were discussed, hoping to provide theoretical and technical guidance for the creation of high-performance enzyme sensing elements and the manufacture of enzyme electrode sensors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Finite element analysis of three internal fixation modalities for treatment of Pauwels type Ⅲ femoral neck fractures under different loading conditions
Zhenggang LI ; Xuehong SHANG ; Zhang WU ; Hong LI ; Chaojun SUN ; Huadong CHEN ; Zhe SUN ; Yi YANG
Chinese Journal of Tissue Engineering Research 2025;29(3):455-463
BACKGROUND:There is still no consensus on the optimal internal fixation for the treatment of Pauwels Ⅲ femoral neck fracture,and most of the related finite element analyses have been performed using a single simplified loading condition,and the biomechanical properties of commonly used internal fixation devices need to be further investigated. OBJECTIVE:To analyze the biomechanical characteristics of Pauwels Ⅲ femoral neck fractures treated with cannulated compression screw,dynamic hip screw,and femoral neck system by finite element method under different loading conditions of single-leg standing loads and sideways fall loads. METHODS:The DICOM data of healthy adult femur were obtained by CT scanning,imported into Mimics 15.0 software to obtain the rough model of bone tissue.The data exported from Mimics were optimized by Geomagics software,and then three internal fixation models were built and assembled with the femur model according to the parameters of the clinical application of the cannulated compression screw,dynamic hip screw,and femoral neck system by using Pro/E software.Finally,the three internal fixation models were imported into Ansys software for loading and calculation to analyze the stress distribution and displacement of the femur and the internal fixation under different working conditions of single-leg standing loads and sideways fall loads,as well as the stress characteristics of the calcar femorale and Ward's triangle. RESULTS AND CONCLUSION:(1)Under the single-leg standing load and the sideways fall load,the proximal femoral stress of the three internal fixation models was mainly distributed above the fracture end of the femoral neck.The peak stress of the proximal femoral end,fracture end,Ward triangle,and calcar femorale of the three internal fixation models were the smallest in the femoral neck system model and the largest in the cannulated compression screw model.(2)Under the single-leg standing load and the sideways fall load,the peak displacement of the proximal femur of the three internal fixation models was all located at the top of the femoral head,and the peak displacement was the smallest in the femoral neck system model and the largest in the cannulated compression screw model.(3)The peak displacement of the three internal fixation models was all located at the top of the internal fixation device under the single-leg standing and sideways fall loading conditions,and the peak displacement values were the smallest in the femoral neck system internal fixation model and the largest in the cannulated compression screw internal fixation model.(4)The internal fixation stress of the three internal fixation models was mainly distributed in the area near the fracture end of the internal fixation device under the single-leg standing and sideways fall loads,and the peak value of internal fixation stress was the smallest in the femoral neck system model and the largest in the cannulated compression screw model.(5)These results suggest that the mechanical stability of the femoral neck system is the best,but there may be a risk of stress shielding of the fracture end and calcar femorale.The stress of the internal fixation device of the femoral neck system is more dispersed,and the risk of internal fixation break is lower.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Design, synthesis and anti-Alzheimer's disease activity evaluation of cinnamyl triazole compounds
Wen-ju LEI ; Zhong-di CAI ; Lin-jie TAN ; Mi-min LIU ; Li ZENG ; Ting SUN ; Hong YI ; Rui LIU ; Zhuo-rong LI
Acta Pharmaceutica Sinica 2025;60(1):150-163
19 cinnamamide/ester-triazole compounds were designed, synthesized and evaluated for their anti-Alzheimer's disease (AD) activity. Among them, compound

Result Analysis
Print
Save
E-mail