1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Deficiency of interleukin-9 inhibits osteogenic potential in mice
Yi WANG ; Chichi CHEN ; Xichao ZHOU ; Qin SHI
Chinese Journal of Tissue Engineering Research 2024;28(26):4178-4183
BACKGROUND:Mouse osteogenic potential is regulated by the JAK-STAT signaling pathway,and interleukin-9 can regulate multiple cellular functions through the JAK-STAT pathway,which has the potential to be a novel cytokine that regulates osteogenic potential. OBJECTIVE:To investigate the effect of interleukin-9 deficiency on osteogenic potential in mice METHODS:The femurs collected from 2-month-old wild-type and interleukin-9 knockout mice were subjected to Micro-CT scanning to analyze the changes in bone mass.Then,hematoxylin-eosin staining,Masson staining,and immunohistochemical staining of type Ⅰ collagen were performed on the slices of the femurs of mice.Bone marrow cells from 2-month-old wild-type and interleukin-9 knockout mice were extracted for colony-forming assay and detection of osteogenic gene expression in bone marrow mesenchymal stem cells.To further verify whether interleukin-9 worked through the JAK-STAT pathway,the expression of STAT3 protein was detected by western blot. RESULTS AND CONCLUSION:Micro-CT results showed the bone mass of interleukin-9 knockout mice decreased significantly compared with that of wild-type mice.In addition,the bone mineral density,bone volume fraction,trabecular number significantly decreased and trabecular separation markedly escalated in interleukin-9 knockout mice.The findings of hematoxylin-eosin staining were consistent with Micro-CT results.Interleukin-9 knockout mice had lower bone trabecular density.Type I collagen immunohistochemistry staining and Masson staining indicated the number of type Ⅰ collagen positive osteoblasts was significantly reduced and the capacity of collagen formation was damaged in interleukin-9 knockout mice.The results of colony-forming assay indicated that the mineralization capacity of osteoblast in interleukin-9 knockout mice were significantly lower than that in wild-type mice.Western blot results showed that osteogenesis induction activated STAT3 signaling,and the pSTAT3 level in wild-type mice with osteogenic induction was significantly higher than that in interleukin-9 knockout mice with osteogenic induction.These findings suggest that interleukin-9 regulates osteogenesis through the JAK-STAT3 pathway and interleukin-9 deficiency inhibits osteoblast differentiation and function,which may lead to reduced bone mass in interleukin-9 knockout mice.
7.Evaluation of the safety and efficacy of mitomycin C-perfluorooctyl bromide liposome nanoparticles in the treatment of human pterygium fibroblasts
Tao LI ; Lingshan LIAO ; Shenglan ZHU ; Juan TANG ; Xiaoli WU ; Qilin FANG ; Ying LI ; Biao LI ; Qin TIAN ; Junmei WAN ; Yi YANG ; Yueyue TAN ; Jiaqian LI ; Juan DU ; Yan ZHOU ; Dan ZHANG ; Xingde LIU
Recent Advances in Ophthalmology 2024;44(2):100-105
Objective To prepare a nano drug(PFOB@Lip-MMC)with liposome as the carrier,liquid perfluorooc-tyl bromide(PFOB)as core and mitomycin C(MMC)loading on the liposome shell and study its inhibitory effect on the proliferation of human pterygium fibroblasts(HPFs).Methods The thin film dispersion-hydration ultrasonic method was used to prepare PFOB@Lip-MMC and detect its physical and chemical properties.Cell Counting Kit-8,Cam-PI cell viability staining and flow cytometry were employed to detect the impact of different concentrations of PFOB@Lip-MMC on the via-bility of HPFs.DiI fluorescence labeled PFOB@Lip-MMC was used to observe the permeability of the nano drug to HPFs under a laser confocal microscope.After establishing HPF inflammatory cell models,they were divided into the control group(with sterile phosphate-buffered saline solution added),PFOB@Lip group(with PFOB@Lip added),MMC group(with MMC added),PFOB@Lip-MMC group(with PFOB@Lip-MMC added)and normal group(with fresh culture medi-um added)according to the experimental requirements.After co-incubation for 24 h,flow cytometer was used to detect the apoptosis rate of inflammatory cells,and the gene expression levels of interleukin(IL)-1β,prostaglandin E2(PGE2),tumor necrosis factor(TNF)-α and vascular endothelial growth factor(VEGF)in cells were analyzed by PCR.Results The average particle size and Zeta potential of PFOB@Lip-MMC were(103.45±2.17)nm and(27.34±1.03)mV,respec-tively,and its entrapped efficiency and drug loading rate were(72.85±3.28)%and(34.27±2.04)%,respectively.The sustained-release MMC of drug-loaded nanospheres reached(78.34±2.92)%in vitro in a 24-hour ocular surface environ-ment.The biological safety of PFOB@Lip-MMC significantly improved compared to MMC.In terms of the DiI fluorescence labeled PFOB@Lip-MMC,after co-incubation with inflammatory HPFs for 2 h,DiI fluorescence labeling was diffusely dis-tributed in the cytoplasm of inflammatory HPFs.The apoptosis rate of inflammatory HPFs in the PFOB@Lip-MMC group[(77.23±4.93)%]was significantly higher than that in the MMC group[(51.62±3.28)%].The PCR examination results showed that the gene transcription levels of IL-1 β,PGE2,TNF-α and VEGF in other groups were significantly reduced com-pared to the control group and PFOB@Lip group,with the most significant decrease in the PFOB@Lip-MMC group(all P<0.05).Conclusion In this study,a novel nano drug(PFOB@LIP-MMC)that inhibited the proliferation of HPFs was successfully synthesized,and its cytotoxicity was significantly reduced compared to the original drugs.It has good bio-compatibility and anti-inflammatory effects,providing a new treatment approach for reducing the recurrence rate after pte-rygium surgery.
8.Evaluation of analgesic effect of nalbuphine in patients with non-mechanical ventilation in intensive care unit: a multi-center randomized controlled trail
Yi ZHOU ; Shaohua LIU ; Song QIN ; Guoxiu ZHANG ; Yibin LU ; Xiaoguang DUAN ; Haixu WANG ; Ruifang ZHANG ; Shuguang ZHANG ; Yonggang LUO ; Yu FANG ; Xiaoyun FU ; Tao CHEN ; Lening REN ; Tongwen SUN
Chinese Journal of Emergency Medicine 2024;33(1):59-64
Objective:To analyze the efficacy and safety of nalbuphine for analgesia in patients with non-mechanical ventilation in intensive care unit (ICU).Methods:From December 2018 to August 2021, a multicenter randomized controlled clinical study was conducted to select non-mechanical ventilation patients with analgesic needs admitted to ICU of four hospitals in Henan Province and Guizhou Province. Patients were randomly assigned to nalbuphine group and fentanyl group. The nalbuphine group was given continuous infusion of nalbuphine [0.05~0.20 mg/(kg·h)], and the fentanyl group was given continuous infusion of fentanyl [0.5~2.0 μg/(kg·h)]. The analgesic target was critical-care pain observation tool (CPOT) score<2. The observation time was 48 hours. The primary endpoint was CPOT score, the secondary endpoints were Richmond agitation-sedation score (RASS), ICU length of stay, adverse events, and proportion of mechanical ventilation. The quantitative data of the two groups were compared by t test or Mann-Whitney U test. The enumeration data were compared by chi square test or Fisher exact probability method. The data at different time points between groups were compared by repeated measures analysis of variance. Results:A total of 210 patients were enrolled, including 105 patients in the nalbuphine group and 105 patients in the fentanyl group. There was no significant difference in baseline data between the two groups (all P>0.05). There was no significant difference in CPOT score between nalbuphine group and fentanyl group at each time point after medication ( P>0.05), the CPOT score of both groups at each time point after medication was significantly lower than that before medication, and the analgesic target could be achieved and maintained 2 hours after medication. There was no significant difference in RASS between the two groups at each time point after medication ( P>0.05), which was significantly lower than that before medication, and the target sedative effect was achieved 2 hours after medication. There was no significant difference in ICU length of stay between nalbuphine group and fentanyl group [5.0(4.0,7.5) d vs. 5.0(4.0,8.0) d, P=0.504]. The incidence of delirium, nausea and vomiting, abdominal distension, pruritus, vertigo and other adverse events in the nalbuphine group was lower than that in the fentanyl group (all P<0.05). There was no significant difference in the incidence of other adverse events such as deep sedation, hypotension and bradycardia between the two groups (all P>0.05). The incidence of respiratory depression in nalbuphine group was not significantly different from that in fentanyl group ( P>0.05), but the proportion of mechanical ventilation was significantly lower than that in the fentanyl group [1.9% (2/105) vs. 8.6%(9/105), P=0.030]. Conclusions:Nalbuphine could be used for analgesia in ICU patients with non-mechanical ventilation. The target analgesic effect could be achieved within 2 hours, and it had a certain sedative effect with a low incidence of adverse reactions.
9.Research and Application of Nanozymes in Disease Treatment
Hang LIU ; Yi-Xuan LI ; Zi-Tong QIN ; Jia-Wen ZHAO ; Yue-Jie ZHOU ; Xiao-Fei LIU
Progress in Biochemistry and Biophysics 2024;51(3):575-589
Nanozyme is novel nanoparticle with enzyme-like activity, which can be classified into peroxidase-like nanozyme, catalase-like nanozyme, superoxide dismutase-like nanozyme, oxidase-like nanozyme and hydrolase-like nanozyme according to the type of reaction they catalyze. Since researchers first discovered Fe3O4 nanoparticles with peroxidase-like activity in 2007, a variety of nanoparticles have been successively found to have catalytic activity and applied in bioassays, inflammation control, antioxidant damage and tumor therapy, playing a key role in disease diagnosis and treatment. We summarize the use of nanozymes with different classes of enzymatic activity in the diagnosis and treatment of diseases and describe the main factors influencing nanozyme activity. A Mn-based peroxidase-like nanozyme that induces the reduction of glutathione in tumors to produce glutathione disulfide and Mn2+, which induces the production of reative oxygen species (ROS) in tumor cells by breaking down H2O2 in physiological media through Fenton-like action, thereby inhibiting tumor cell growth. To address the limitation of tumor tissue hypoxia during photodynamic tumor therapy, the effect of photodynamic therapy is significantly enhanced by using hydrogen peroxide nanozymes to catalyze the production of oxygen from H2O2. In pathological states, where excess superoxide radicals are produced in the body, superoxide dismutase-like nanozymes are able to selectively regulate intracellular ROS levels, thereby protecting normal cells and slowing down the degradation of cellular function. Based on this principle, an engineered nanosponge has been designed to rapidly scavenge free radicals and deliver oxygen in time to save nerve cells before thrombolysis. Starvation therapy, in which glucose oxidase catalyzes the hydrolysis of glucose to gluconic acid and hydrogen peroxide in cancer cells with the involvement of oxygen, attenuates glycolysis and the production of intermediate metabolites such as nucleotides, lipids and amino acids, was used to synthesize an oxidase-like nanozyme that achieved effective inhibition of tumor growth. Furthermore, by fine-tuning the Lewis acidity of the metal cluster to improve the intrinsic activity of the hydrolase nanozyme and providing a shortened ligand length to increase the density of its active site, a hydrolase-like nanozyme was successfully synthesized that is capable of cleaving phosphate bonds, amide bonds, glycosidic bonds and even biofilms with high efficiency in hydrolyzing the substrate. All these effects depend on the size, morphology, composition, surface modification and environmental media of the nanozyme, which are important aspects to consider in order to improve the catalytic efficiency of the nanozyme and have important implications for the development of nanozyme. Although some progress has been made in the research of nanozymes in disease treatment and diagnosis, there are still some problems, for example, the catalytic rate of nanozymes is still difficult to reach the level of natural enzymes in vivo, and the toxic effects of some heavy metal nanozymes material itself. Therefore, the construction of nanozyme systems with multiple functions, good biocompatibility and high targeting efficiency, and their large-scale application in diagnosis and treatment is still an urgent problem to be solved. (1) To improve the selectivity and specificity of nanozymes. By using antibody coupling, the nanoparticles are able to specifically bind to antigens that are overexpressed in certain cancer cells. It also significantly improves cellular internalization through antigen-mediated endocytosis and enhances the enrichment of nanozymes in target tissues, thereby improving targeting during tumor therapy. Some exogenous stimuli such as laser and ultrasound are used as triggers to control the activation of nanozymes and achieve specific activation of nanozyme. (2) To explore more practical and safer nanozymes and their catalytic mechanisms: biocompatible, clinically proven material molecules can be used for the synthesis of nanoparticles. (3) To solve the problem of its standardization and promote the large-scale clinical application of nanozymes in biomonitoring. Thus, it can go out of the laboratory and face the market to serve human health in more fields, which is one of the future trends of nanozyme development.
10.Effects of sodium acetate on lowering uric acid and renal protection in mice with hyperuricemic nephropathy
Xue-Man LIN ; Shi-Qi ZHONG ; Yong-Mei LI ; Xiao-Yi QIN ; He-Yang JIANG ; Jia-Xin ZHOU ; Jian-Xin PANG ; Ting WU
The Chinese Journal of Clinical Pharmacology 2024;40(15):2222-2226
Objective To investigate the renal protective effect and mechanism of sodium acetate(Ace)on hyperuricemic nephropathy(HN)in mice.Methods Uric acid nephropathy mice model was prepared by intraperitoneal injection of potassium oxonate combined with adenine gavage.Mice were divided into blank control group(0.9%NaCl+0.5%carboxymethyl cellulose sodium),Ace group(200 mmol·L-1 Ace+0.5%carboxymethyl cellulose sodium),model group(0.9%NaCl+350 mg·kg-1 potassium oxonate+70 mg·kg-1 adenine),and experimental group(based on model group with additional 200 mmol·L-1 Ace).Serum and urine uric acid(UA)and serum creatinine(SCr)levels were observed in each group.Real-time fluorescence quantitative reverse transcription-polymerase chain reaction(qRT-PCR)was used to detect the expression levels of kidney injury molecule-1(Kim-1)and anti-aging gene Klotho,renal fibrosis markers Collagen Ⅰ and Fibronectin,intestinal inflammation-related factors interleukin-1 β(IL-1 β),and mRNA expression levels of tight junction proteins Zo-1.Results The serum UA levels of blank control group,Ace group,model group,and experimental group mice were(259.52±24.40),(227.71±35.91),(604.06±73.55),and(496.24±30.16)μmol·L-1,respectively;SCr levels were(16.85±0.40),(16.18±0.94),(22.38±1.56),and(19.78±1.43)μmol·L-1;Kim-1 mRNA relative expression levels were 1.04±0.25,1.17±0.28,13.00±2.87,and 4.24±3.92;Klotho mRNA relative expression levels were 1.04±0.15,1.02±0.18,0.43±0.12,and 0.69±0.12;Collagen Ⅰ mRNA relative expression levels were 1.05±0.15,1.02±0.18,3.19±1.09,and 1.61±0.55;Fibronectin mRNA relative expression levels were 1.07±0.18,1.02±0.25,7.86±2.40,and 3.34±2.10;intestinal IL-1β mRNA relative expression levels were 1.00±0.01,1.01±0.03,2.55±0.63,and 1.21±0.28;intestinal Zo-1 mRNA relative expression levels were 1.00±0.07,1.07±0.09,0.54±0.20,and 0.92±0.17.The above indicators in blank control group compared with model group,and experimental group compared with model group,all showed statistically significant differences(P<0.05,P<0.01,P<0.001).Conclusion Sodium acetate can effectively reduce UA levels in HN mice,significantly improve renal injury and fibrosis,and its mechanism may be related to the improvement of intestinal inflammatory response and up-regulation of intestinal Zo-1/Occuludin pathway to reduce intestinal mucosal permeability.

Result Analysis
Print
Save
E-mail