1.Research progress on prevention strategies for immune platelet transfusion refractoriness
Peizhe ZHAO ; Yi XU ; Yajun LIANG ; Qing LI ; Yuan ZHOU ; Xianguo XU
Chinese Journal of Blood Transfusion 2025;38(3):448-454
Platelet transfusion refractoriness (PTR) is a common issue among patients with hematological diseases and tumors. This article reviews the diagnostic criteria, influencing factors, and recent prevention and management strategies for immune PTR. The diagnostic criteria typically involve post-transfusion platelet increment (PI), platelet recovery rate (PPR), and corrected count increment (CCI). Both immune and non-immune factors can lead to PTR, with immune factors mainly including HLA and HPA antibodies. Prevention and management strategies include the use of leukocyte-reduced platelets, HLA and HPA antigen-matched platelets, intravenous immunoglobulin therapy, and immunosuppressive strategies. Although various strategies have been proposed and applied in clinical practice, the prevention and management of immune PTR remain challenging. Future research needs to explore more effective individualized treatment strategies, while also considering the potential application of emerging technologies such as nanotechnology in the field of transfusion.
2.Changes in the body shape and ergonomic compatibility for functional dimensions of desks and chairs for students in Harbin during 2010-2024
Chinese Journal of School Health 2025;46(3):315-320
Objective:
To analyze the change trends in the body shape indicators and proportions of students in Harbin from 2010 to 2024, and to investigate ergonomic compatibility of functional dimensions of school desks and chairs with current student shape indicators, so as to provide a reference for revising furniture standards of desks and chairs.
Methods:
Between September and November of both 2010 and 2024, a combination of convenience sampling and stratified cluster random sampling was conducted across three districts in Harbin, yielding samples of 6 590 and 6 252 students, respectively. Anthropometric shape indicators cluding height, sitting height, crus length, and thigh length-and their proportional changes were compared over the 15-year period. The 2024 data were compared with current standard functional dimensions of school furniture. The statistical analysis incorporated t-test and Mann-Whitney U- test.
Results:
From 2010 to 2024, average height increased by 1.8 cm for boys and 1.5 cm for girls; sitting height increased by 1.5 cm for both genders; crus length increased by 0.3 cm for boys and 0.4 cm for girls; and thigh length increased by 0.5 cm for both genders. The ratios of sitting height to height, and sitting height to leg length increased by less than 0.1 . The difference between desk chair height and 1/3 sitting height ranged from 0.4-0.8 cm. Among students matched with size 0 desks and chairs, 22.0% had a desk to chair height difference less than 0, indicating that the desk to chair height difference might be insufficient for taller students. The differences between seat height and fibular height ranged from -1.4 to 1.1 cm; and the differences between seat depth and buttock popliteal length ranged from -9.8 to 3.4 cm. Among obese students, the differences between seat width and 1/2 hip circumference ranged from -20.5 to -8.7 cm, while it ranged from -12.2 to -3.8 cm among non obese students.
Conclusion
Current furniture standards basically satisfy hygienic requirements; however, in the case of exceptionally tall and obese students, ergonomic accommodations such as adaptive seating allocation or personalized adjustments are recommended to meet hygienic requirements.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Application of the Third-generation Intracavitary Combined With Interstitial Brachytherapy Applicator Template for Cervical Cancer
Xiang ZHOU ; Xiaodan HUANG ; Huimin XU ; Yi OUYANG
Journal of Sun Yat-sen University(Medical Sciences) 2025;46(2):354-360
ObjectiveTo evaluate a third-generation applicator template for intracavitary combined with interstitial brachytherapy (IC-ISBT) suitable for locally advanced cervical cancer, aiming to improve therapeutic outcomes. MethodsA retrospective study was conducted on patients with stage IB3-ⅣB cervical cancer treated at Sun Yat-sen University Cancer Center from January 2023 to October 2023. Magnetic resonance imaging data before and after external beam radiation therapy were collected and analyzed. According to the residual tumor after external beam radiation, high-risk clinical target volumes (HR-CTV) were delineated, based on which a third-generation IC-ISBT applicator template was designed. The dosimetric and therapeutic differences between using this applicator template (template implantation group) and traditional freehand interstitial implantation (freehand implantation group) were further compared. Statistical methods were used to analyze the data from both groups to test the efficacy and safety of the two approaches. ResultsThe third-generation applicator template could accommodate different cervical structures and optimize needle path layout. The tumor volume in the template implantation group was significantly larger than in the freehand implantation group, showing statistical differences. In terms of dosimetric coverage (V100%), the template implantation group exhibited significant statistical differences compared with the freehand implantation group, demonstrating superior dose coverage. Additionally, the third-generation template showed advantages in protecting the rectum and sigmoid colon by potentially reducing high-dose points, while there were no significant differences in bladder dosimetry between the two methods. The primary cervical lesion remission rates were similar between the two groups. ConclusionThe third-generation IC-ISBT applicator template is scientifically and rationally designed, especially for patients with larger tumor volumes and later stages. It is easy to operate, highly reproducible, and shows significant advantages in dose distribution and protection of surrounding critical organs. The template has the potential to be widely applied as a routine treatment option.
9.Triglyceride-glucose index and homocysteine in association with the risk of stroke in middle-aged and elderly diabetic populations
Xiaolin LIU ; Jin ZHANG ; Zhitao LI ; Xiaonan WANG ; Juzhong KE ; Kang WU ; Hua QIU ; Qingping LIU ; Jiahui SONG ; Jiaojiao GAO ; Yang LIU ; Qian XU ; Yi ZHOU ; Xiaonan RUAN
Shanghai Journal of Preventive Medicine 2025;37(6):515-520
ObjectiveTo investigate the triglyceride-glucose (TyG) index and the level of serum homocysteine (Hcy) in association with the incidence of stroke in type 2 diabetes mellitus (T2DM) patients. MethodsBased on the chronic disease risk factor surveillance cohort in Pudong New Area, Shanghai, excluding those with stroke in baseline survey, T2DM patients who joined the cohort from January 2016 to October 2020 were selected as the research subjects. During the follow-up period, a total of 318 new-onset ischemic stroke patients were selected as the case group, and a total of 318 individuals matched by gender without stroke were selected as the control group. The Cox proportional hazards regression model was used to adjust for confounding factors and explore the serum TyG index and the Hcy biochemical indicator in association with the risk of stroke. ResultsThe Cox proportional hazards regression results showed that after adjusting for confounding factors, the risk of stroke in T2DM patients with 10 μmol·L⁻¹
10.Effects of superoxide dismutase inhibition of AFP expression on the malignant biological behavior of PLC/PRF/5 liver cancer cells
Yi CHEN ; Baoying CHEN ; Yuli ZHOU ; Haixia XU ; Yu CAO ; Yue GU ; Mingyue ZHU ; Mengsen LI
China Pharmacy 2025;36(17):2120-2126
OBJECTIVE To explore the effect of superoxide dismutase (SOD) administration on the malignant behavior of PLC/PRF/5 liver cancer cells, and analyze the correlation between SOD and alpha-fetoprotein (AFP) expression, to provide new ideas for targeting AFP with SOD as a drug for hepatocellular carcinoma. METHODS Normal human liver cells L-02, AFP- negative human liver cancer cells HLE, and AFP-positive human liver cancer cells PLC/PRF/5 were used as experimental cells. Western blot assay and SOD activity detection kit were used to detect the expression of AFP, SOD and activity of SOD in cells before and after changing AFP expression; the effects of different concentrations of SOD [0 (control), 0.188, 0.375, 0.75, 1.5, 3 U/mL] administration on the migration and proliferation of PLC/PRF/5 cells were detected using cell scratch assay and CCK-8 assay. The effects of SOD overexpression on the expression of malignant biological behavior-related proteins AFP and sarcoma virus protein (Src) in PLC/PRF/5 cells were detected using Western blot. RESULTS Compared with L-02 group and HLE group, the expression levels of SOD1 and SOD2, and SOD activity in PLC/PRF/5 cells were significantly reduced (P<0.05). After down-regulating AFP expression in PLC/PRF/ 5 cells, compared with PLC/PRF/5 group, the expression levels of SOD1 and SOD2, as well as SOD activity, were significantly increased in the PLC/PRF/5-shAFP group (low-expression) (P<0.05). After 48 hours of SOD treatment, compared with control group, the scratch healing rates of PLC/PRF/5 cells in the 0.375, 0.75, 1.5 and 3 U/mL SOD groups were significantly reduced (P<0.05); after 72 hours of SOD treatment, compared with control group, the scratch healing rates of PLC/PRF/5 cells in the 0.375, 0.75, and 1.5 U/mL SOD groups were significantly reduced (P<0.05 or P<0.01). Compared with control group, proliferation rates of PLC/PRF/5 cells were significantly reduced in the 0.375, 0.75, 1.5 and 3 U/mL SOD groups (P<0.05 or P<0.01). Compared with the PLC/PRF/5 group before up-regulating SOD1 and SOD2 expression, the expression levels of AFP and Src in the PLC/PRF/5-oeSOD1 and PLC/PRF/5-oeSOD2 groups (over-expression) after up-regulating SOD1 and SOD2 expression were significantly reduced (P<0.05). CONCLUSIONS A certain concentration of SOD can inhibit malignant behavior such as migration and proliferation of PLC/PRF/5 cells, and the expression level and activity of SOD are negatively correlated with AFP.


Result Analysis
Print
Save
E-mail