1.Correlation of serum leucine-rich α-2 glycoprotein 1 and fibroblast growth factor 21 levels with neovascular glaucoma
Zhong LUO ; He ZHOU ; Yi HUANG ; Wanjiang DONG
International Eye Science 2025;25(1):118-121
AIM: To investigate the correlation of serum leucine-rich α-2 glycoprotein 1(LRG1)and fibroblast growth factor 21(FGF-21)levels with neovascular glaucoma(NVG).METHODS: A total of 110 cases(110 eyes)with NVG admitted to the ophthalmology department from September 2020 to September 2022 were selected as NVG group, with 23 cases of grade II, 44 cases of grade III, and 43 cases of grade IV, while 90 sex and age matched cataract patients(90 eyes)were selected as control group. The levels of LRG1, FGF-21, vascular endothelial growth factor(VEGF), pigment epithelium-derived factor(PEDF), and tumor necrosis factor-α(TNF-α)in serum were detected by ELISA; Pearson correlation analysis was used to analyze the correlation of serum LRG1 and FGF-21 levels with Teich grade, VEGF, PEDF and TNF-α levels.RESULTS: The levels of serum LRG1, FGF-21, VEGF, PEDF and TNF-α in the NVG group were significantly higher than those in the control group(all P<0.01). With the increase of Teich grading, the levels of serum LRG1, FGF-21, VEGF, PEDF and TNF-α in NVG patients significantly increased in turn(all P<0.05). Correlation analysis showed that the levels of LRG1 and FGF-21 in serum of NVG patients were positively correlated with the levels of VEGF, PEDF and TNF-α(all P<0.05).CONCLUSION: The levels of LRG1 and FGF-21 in serum of patients with NVG are obviously increased, which are positively correlated with the levels of VEGF, PEDF and TNF-α, both of which may be related to the development of NVG.
2.Cognition and countermeasures of medical science and technology ethics management among medical staff in five tertiary hospitals in Ningxia Hui Autonomous Region
Chinese Medical Ethics 2025;38(1):63-71
ObjectiveTo understand the current situation and influencing factors of cognition level, as well as existing problems in the construction of medical science and technology ethics management among medical staff in five tertiary hospitals in Ningxia Hui Autonomous Region, to provide references for enhancing their awareness of medical science and technology ethics management and improving the quality of clinical research. MethodsUsing a self-designed and validated “Medical Science and Technology Ethics Management Cognitive Questionnaire for Medical Staff,” medical staff from five tertiary hospitals in five cities in Ningxia were selected as the research subjects for investigation. ResultsFinally, 436 valid questionnaires were collected, among which the total average score for medical staff’s cognition of medical science and technology ethics management was (61.58±12.96) points. The scores of ethics system cognition, ethics committee cognition, ethics education and training cognition, and ethics management informatization cognition were (14.18±2.84) points, (24.19±5.47) points, (15.07±4.00) points, and (8.14±4.42) points, respectively. Multiple linear regression analysis showed that age, work city, education level, professional title, whether they had assessed the implementation of the hospital ethics system, whether they had participated in the hospital’s ethics review work, and whether they had organized or participated the hospital’s ethics training, were all influencing factors on the cognitive score of medical science and technology ethics management among medical staff, which can explain 51.00% of the variation (P<0.05). Medical staff considered that inadequate promotion of ethical systems, opaque ethical review procedures and processes, conflicts between ethical training time and work tasks, and the lack of a dedicated ethical review information platform were the main problems in constructing medical science and technology ethics. ConclusionThe cognition level of medical science and technology ethics management among medical staff in tertiary hospitals in Ningxia was generally not high and was influenced by various factors. Hospital managers should strengthen the publicity and training of ethical systems, as well as improve their implementation and supervision mechanisms; standardize ethical review procedures and processes, as well as build an ethical review information platform; increase investment in ethics education and arrange training time reasonably, to enhance the awareness of medical science and technology ethics management among medical staff and improve the quality of clinical research.
3.Clinical Observation of Guben Quyu Jiedu Prescription in Treating Nocturnal Hypoxemia of COPD Combined with OSAHS
Yi HE ; Ziyu LI ; Wenjiang ZHANG ; Jinzhu GAO ; Changzheng FAN ; Beibei WANG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(6):146-153
ObjectiveTo observe the clinical efficacy and safety of Guben Quyu Jiedu prescription in treating nocturnal hypoxemia of chronic obstructive pulmonary disease (COPD) combined with Obstructive sleep apnea hypopnea syndrome ( OSAHS ) (deficiency of lung, spleen and kidney with blood stasis and toxicity). MethodsThe paper used a forward-looking, random double-blind, placebo-controlled design method to select 96 patients with COPD combined with OSAHS, and their traditional Chinese medicines (TCM) syndrome differentiation was deficiency of lung, spleen and kidney with blood stasis and toxicity. These patients were randomly divided into the observation group and the control group, with 48 cases in each group. Based on conventional Western medicine treatment, the observation group was treated with Guben Quyu Jiedu prescription and the control group was treated with traditional Chinese medicine placebo. Both courses of treatment were 90 days. Then the paper compared the changes in minimum pulse oxygen saturation (SpO2) during the night, apnea index (AHI), OSAHS efficacy evaluation, TCM syndrome efficacy evaluation, and TCM symptom score before and after treatment between the two groups. ResultsThere were 5 withdrawals in the observation group and 8 withdrawals in the control group, so 43 cases in the observation group and 40 cases in the control group completed the trial. Compared with the condition before treatment, the minimum SpO2 during the night and AHI in the observation group were significantly improved at night (P<0.01) and were better than those in the control group (P<0.01). OSAHS efficacy in the observation group was better than in the control group (χ2=7.085, P<0.05). In terms of TCM syndrome efficacy, the total effective rate was 81.40% (35/43) in the observation group, significantly higher than that in the control group, which was 15.00% (6/40) (χ2=36.78, P<0.01). The TCM symptom scores of the two groups were improved compared with the condition before treatment, and the effect of the two groups was similar in the four main symptoms of snoring, choking, lethargy, and cough. However, the observation group was better than the control group in 10 details such as dizziness, headache, chest tightness, chest pain, wheezing, dry mouth, and thirst (P<0.05). ConclusionUsing Guben Quyu Jiedu prescription combined with conventional Western medicine can treat COPD combined with OSAHS hypoxemia at night (deficiency of lung, spleen and kidney with blood stasis and toxicity). In this way, the minimum pulse oxygen saturation (SpO2) of patients, the level of disease control, and the quality of life of patients can be improved, and the clinical symptoms can be relieved.
4.Enzyme-directed Immobilization Strategies for Biosensor Applications
Xing-Bao WANG ; Yao-Hong MA ; Yun-Long XUE ; Xiao-Zhen HUANG ; Yue SHAO ; Yi YU ; Bing-Lian WANG ; Qing-Ai LIU ; Li-He ZHANG ; Wei-Li GONG
Progress in Biochemistry and Biophysics 2025;52(2):374-394
Immobilized enzyme-based enzyme electrode biosensors, characterized by high sensitivity and efficiency, strong specificity, and compact size, demonstrate broad application prospects in life science research, disease diagnosis and monitoring, etc. Immobilization of enzyme is a critical step in determining the performance (stability, sensitivity, and reproducibility) of the biosensors. Random immobilization (physical adsorption, covalent cross-linking, etc.) can easily bring about problems, such as decreased enzyme activity and relatively unstable immobilization. Whereas, directional immobilization utilizing amino acid residue mutation, affinity peptide fusion, or nucleotide-specific binding to restrict the orientation of the enzymes provides new possibilities to solve the problems caused by random immobilization. In this paper, the principles, advantages and disadvantages and the application progress of enzyme electrode biosensors of different directional immobilization strategies for enzyme molecular sensing elements by specific amino acids (lysine, histidine, cysteine, unnatural amino acid) with functional groups introduced based on site-specific mutation, affinity peptides (gold binding peptides, carbon binding peptides, carbohydrate binding domains) fused through genetic engineering, and specific binding between nucleotides and target enzymes (proteins) were reviewed, and the application fields, advantages and limitations of various immobilized enzyme interface characterization techniques were discussed, hoping to provide theoretical and technical guidance for the creation of high-performance enzyme sensing elements and the manufacture of enzyme electrode sensors.
5.Research and Application of Scalp Surface Laplacian Technique
Rui-Xin LUO ; Si-Ying GUO ; Xin-Yi LI ; Yu-He ZHAO ; Chun-Hou ZHENG ; Min-Peng XU ; Dong MING
Progress in Biochemistry and Biophysics 2025;52(2):425-438
Electroencephalogram (EEG) is a non-invasive, high temporal-resolution technique for monitoring brain activity. However, affected by the volume conduction effect, EEG has a low spatial resolution and is difficult to locate brain neuronal activity precisely. The surface Laplacian (SL) technique obtains the Laplacian EEG (LEEG) by estimating the second-order spatial derivative of the scalp potential. LEEG can reflect the radial current activity under the scalp, with positive values indicating current flow from the brain to the scalp (“source”) and negative values indicating current flow from the scalp to the brain (“sink”). It attenuates signals from volume conduction, effectively improving the spatial resolution of EEG, and is expected to contribute to breakthroughs in neural engineering. This paper provides a systematic overview of the principles and development of SL technology. Currently, there are two implementation paths for SL technology: current source density algorithms (CSD) and concentric ring electrodes (CRE). CSD performs the Laplace transform of the EEG signals acquired by conventional disc electrodes to indirectly estimate the LEEG. It can be mainly classified into local methods, global methods, and realistic Laplacian methods. The global method is the most commonly used approach in CSD, which can achieve more accurate estimation compared with the local method, and it does not require additional imaging equipment compared with the realistic Laplacian method. CRE employs new concentric ring electrodes instead of the traditional disc electrodes, and measures the LEEG directly by differential acquisition of the multi-ring signals. Depending on the structure, it can be divided into bipolar CRE, quasi-bipolar CRE, tripolar CRE, and multi-pole CRE. The tripolar CRE is widely used due to its optimal detection performance. While ensuring the quality of signal acquisition, the complexity of its preamplifier is relatively acceptable. Here, this paper introduces the study of the SL technique in resting rhythms, visual-related potentials, movement-related potentials, and sensorimotor rhythms. These studies demonstrate that SL technology can improve signal quality and enhance signal characteristics, confirming its potential applications in neuroscientific research, disease diagnosis, visual pathway detection, and brain-computer interfaces. CSD is frequently utilized in applications such as neuroscientific research and disease detection, where high-precision estimation of LEEG is required. And CRE tends to be used in brain-computer interfaces, that have stringent requirements for real-time data processing. Finally, this paper summarizes the strengths and weaknesses of SL technology and envisages its future development. SL technology boasts advantages such as reference independence, high spatial resolution, high temporal resolution, enhanced source connectivity analysis, and noise suppression. However, it also has shortcomings that can be further improved. Theoretically, simulation experiments should be conducted to investigate the theoretical characteristics of SL technology. For CSD methods, the algorithm needs to be optimized to improve the precision of LEEG estimation, reduce dependence on the number of channels, and decrease computational complexity and time consumption. For CRE methods, the electrodes need to be designed with appropriate structures and sizes, and the low-noise, high common-mode rejection ratio preamplifier should be developed. We hope that this paper can promote the in-depth research and wide application of SL technology.
6.Research progress on circular RNA in periodontitis
HE Yi ; HAN Yaoling ; YU Dongsheng
Journal of Prevention and Treatment for Stomatological Diseases 2025;33(3):252-259
Periodontitis, a chronic inflammatory disease caused by plaque biofilm, is characterized by the irreversible pathological destruction of periodontal supporting tissues, including gums, periodontal membranes, alveolar bone, and cementum, resulting in tooth loosening and dislocation in severe cases. Currently, research on the pathogenesis, early diagnosis, and treatment of periodontitis is limited. Circular RNAs (circRNAs), previously considered “splicing noise”, have gained increasing research attention with the development of high-throughput sequencing technologies and bioinformatics. CircRNAs are non-coding RNAs lacking a 5' cap and 3' poly(A) tail, with a unique covalently closed ring structure, high expression, long half-life, and resistance to nuclease degradation, which can regulate splicing, encode proteins, and act as microRNA and RNA-binding protein sponges. In recent years, circRNAs have been reported to be involved in the occurrence and development of periodontitis, suggesting its potential role as a therapeutic target for periodontitis treatment. In this study, we described the biological function of circRNAs and their role in the development of periodontitis and the regulation of periodontal homeostasis and immune microenvironment. We found that circRNAs affect periodontal homeostasis and immune microenvironment by regulating the apoptosis of periodontal tissue cells (such as periodontal ligament stem cells and gingival fibroblasts) and regulating immune cells or cytokines, respectively. This review article summarizes the latest research progress on the association between circRNAs and periodontitis to provide a scientific basis for the development of novel diagnostic, therapeutic, and prognostic strategies for periodontitis.
7.Exploration of Party-building leadership in promoting hospital culture construction in the new era: taking Xi’an No. 9 Hospital as an example
Louyan MA ; Yi WANG ; Zhen ZHEN ; Mi PANG ; Ting HE ; Puyan WEN ; Juxian ZHENG
Chinese Medical Ethics 2025;38(3):398-402
Hospital culture is the sum of common values, codes of conduct, and working methods formed by internal employees within the hospital, and it is the spiritual pillar and core of cohesion of the hospital. Party-building leadership plays an important role in promoting hospital culture construction, including strengthening values guidance, enhancing team cohesion, facilitating management system innovation, and shaping social image and brand value. By analyzing the effectiveness of a series of Party-building activities carried out by Xi’an No. 9 Hospital in recent years, this paper explored the effect and significance of Party-building leadership in promoting hospital culture construction in the new era, as well as proposed guiding strategies for strengthening Party-building work in promoting hospital culture construction in the new era, so as to promote high-quality development of the hospital.
8.A Comparative Study on the Clinical Effects of Short-term and Long-term Spinal Cord Stimulation in Patients with Prolonged Disorders of Consciousness
Fengqiao SUN ; Hongchuan NIU ; Yi YANG ; Jianghong HE ; Yuanli ZHAO
Medical Journal of Peking Union Medical College Hospital 2025;16(2):307-313
To compare the therapeutic effects of short-term spinal cord stimulation (stSCS) and long-term spinal cord stimulation (ltSCS) on patients with prolonged disorders of consciousness(pDoC). Clinical data of patients with pDoC who underwent SCS surgery at Peking University International Hospital from January 2020 to December 2021 were retrospectively included. Patients were divided into the stSCS group and the ltSCS group based on the surgical approach. The Coma recovery scale-revised (CRS-R) was used to assess the level of consciousness before and 3 months after SCS treatment. Based on CRS-R scores, the clinical diagnosis of the patient's level of consciousenss was categorized into four levels: vegetative state, minimally conscious state minus (MCS-), MCS plus (MCS+), and emergence from the minimally conscious state(EMCS). Improvement in the clinical diagnostic level of consciousness was defined as effective treatment, and the therapeutic outcomes of the stSCS and ltSCS groups were compared. 44.8% of patients with pDoC showed improvement in their clinical diagnostic level of consciousness after SCS treatment. Compared to preoperative scores, the CRS-R scores at 3 months postoperatively were significantly increased in both the stSCS and ltSCS groups (both Both stSCS and ltSCS can significantly improve the level of consciousness in patients with pDoC. Compared to ltSCS, stSCS may achieve comparable short-term therapeutic outcomes.
9.Research on The Construction and Application of Multiple Fluorescence Amplification System for Three Kinds of Stains
Yi-Fan BAI ; He-Miao ZHAO ; Jing CHEN ; Hong-Di LIU ; Rui-Qin YANG ; Chong WANG
Progress in Biochemistry and Biophysics 2025;52(4):982-994
ObjectiveA multiplex amplification system was constructed based on the capillary electrophoresis platform for simultaneous detection of saliva, semen, and vaginal secretions using tissue-specific RNA markers. The aim of this study is to identify the tissue origin of suspicious body fluid stains found at crime scenes and determine whether the body fluid stains at the crime scene are one or several types among saliva, semen, and vaginal secretions. MethodsThirty saliva samples, forty semen samples, and forty vaginal secretion samples (half from 2015 and half from 2024) were collected from healthy adult volunteers. Through primer designing, system formulation, and PCR condition optimization, a multiplex fluorescent amplification system was constructed. The specificity, sensitivity, and detection ability for mixed samples of this system were investigated, and it was tested using real crime scene materials. In the primer design stage, to reduce the requirements for RNA template quality, the amplification products were set within 80-300 bp. In the system formulation stage, dominant and subordinate primers were mainly considered. By reducing the concentration of dominant primers and increasing that of subordinate primers, a capillary electrophoresis spectrum with an appropriate peak height ratio was finally obtained. Additionally, gradient experiments were designed to adjust the concentrations of PCR reagents and PCR amplification conditions, and multiple versions of DNA amplification enzymes were optimized to achieve the best experimental results. ResultsThrough statistical analysis, there was no significant difference in the capillary electrophoresis of the 3 types of body fluid samples from the two years (2015 and 2024), demonstrating that the sample preservation method in this study can preserve samples for a relatively long time. The composite amplification system constructed in this study exhibited high specificity for all 3 types of body fluid, with no cross-reactions between the markers of each type of body fluid. The minimum detection thresholds for the 3 types of body fluid reached 0.002 9, 0.001 5, and 0.42 mg/L, respectively. This system also had a high degree of discrimination for mixed samples, especially for semen-saliva mixtures, where each body fluid marker could still be successfully detected when the concentration ratio of semen to saliva was 100:1. Meanwhile, in the two actual cases presented in this article, the application of this composite amplification system performed outstandingly. ConclusionThe composite amplification detection system constructed in this study can achieve the correct screening of saliva, semen, and vaginal secretions, overcoming the problems such as low specificity and sensitivity of marker tests and unbalanced RFU values of each marker in previous studies. The specificity and sensitivity meet the practical work requirements, and the operation is simple. It provides an analytical and identification method for body fluid stains in actual case and is applicable to the identification of the tissue origin of biological evidence at crime scenes involving sexual assault, indecent assault, and other criminal acts. In the future, more types of body fluid markers will be screened to expand the types of body fluids detected by the system, and body fluid-specific cSNP and cInDel genetic markers will be introduced to infer the sources (individuals and types) of mixed and complex stains more accurately.
10.Efficacy and safety of ropivacaine combined with oxycodone for iliac fascia nerve block analgesia in patients undergoing hip replacement
Xinyue ZHANG ; Yapeng HE ; Xianlin ZHU ; Weiqing LIU ; Yi ZHANG ; Zhengsong WAN ; Nana YAO ; Junying MOU
China Pharmacy 2025;36(8):951-955
OBJECTIVE To investigate the efficacy and safety of ropivacaine combined with oxycodone for the analgesia of iliac fascia nerve block in patients undergoing hip replacement. METHODS Sixty-six patients who underwent hip replacement at the Central Hospital of Enshi Tujia and Miao Autonomous Prefecture from October 2023 to April 2024 were selected and randomly divided into observation group and control group, with 33 cases in each group. Before induction of anesthesia, ultrasound-guided iliac fascial nerve block was performed. Patients in the observation group were treated with 0.33% ropivacaine+0.1 mg/kg oxycodone injection mixture 30 mL, and patients in the control group were treated with 0.33% ropivacaine injection 30 mL. The time of first postoperative rescue analgesia, 24 h postoperative analgesic drug consumption, sensory block and motor block effective and maintenance time, satisfaction degree, numerical rating scale (NRS) pain score, Ramsay sedation score, muscle strength score, heart rate (HR), mean arterial pressure (MAP), oxygen saturation(SpO2), sleep score, anxiety score, and the occurrence of adverse reactions in the two groups were all recorded. RESULTS Compared with the control group, the first rescue analgesia time after operation was significantly prolonged in the observation group, and 24 h postoperative analgesic drug consumption after operation decreased; the effective time of sensory block was significantly shortened, and the maintenance time of sensory block was significantly prolonged, and the satisfaction score was higher; the NRS pain score after iliac fascia nerve block was lower, HR and MAP were lower, and the anxiety score and sleep score 24 and 48 h after operation were lower (P<0.05). In terms of safety, patients in both groups had adverse reactions after operation, such as hypertension, nausea, vomiting, and dizziness, but there was no significant difference in the incidence of adverse reactions between the two groups (P>0.05). CONCLUSIONS Oxycodone combined with ropivacaine shows good efficacy and safety for iliac fascial nerve block analgesia in patients undergoing hip replacement, can significantly prolong the analgesic time of ropivacaine, reduce postoperative analgesic drug consumption, improve the sleep quality of patients, and promote the rapid recovery of patients.


Result Analysis
Print
Save
E-mail