1.Changes in the body shape and ergonomic compatibility for functional dimensions of desks and chairs for students in Harbin during 2010-2024
Chinese Journal of School Health 2025;46(3):315-320
Objective:
To analyze the change trends in the body shape indicators and proportions of students in Harbin from 2010 to 2024, and to investigate ergonomic compatibility of functional dimensions of school desks and chairs with current student shape indicators, so as to provide a reference for revising furniture standards of desks and chairs.
Methods:
Between September and November of both 2010 and 2024, a combination of convenience sampling and stratified cluster random sampling was conducted across three districts in Harbin, yielding samples of 6 590 and 6 252 students, respectively. Anthropometric shape indicators cluding height, sitting height, crus length, and thigh length-and their proportional changes were compared over the 15-year period. The 2024 data were compared with current standard functional dimensions of school furniture. The statistical analysis incorporated t-test and Mann-Whitney U- test.
Results:
From 2010 to 2024, average height increased by 1.8 cm for boys and 1.5 cm for girls; sitting height increased by 1.5 cm for both genders; crus length increased by 0.3 cm for boys and 0.4 cm for girls; and thigh length increased by 0.5 cm for both genders. The ratios of sitting height to height, and sitting height to leg length increased by less than 0.1 . The difference between desk chair height and 1/3 sitting height ranged from 0.4-0.8 cm. Among students matched with size 0 desks and chairs, 22.0% had a desk to chair height difference less than 0, indicating that the desk to chair height difference might be insufficient for taller students. The differences between seat height and fibular height ranged from -1.4 to 1.1 cm; and the differences between seat depth and buttock popliteal length ranged from -9.8 to 3.4 cm. Among obese students, the differences between seat width and 1/2 hip circumference ranged from -20.5 to -8.7 cm, while it ranged from -12.2 to -3.8 cm among non obese students.
Conclusion
Current furniture standards basically satisfy hygienic requirements; however, in the case of exceptionally tall and obese students, ergonomic accommodations such as adaptive seating allocation or personalized adjustments are recommended to meet hygienic requirements.
2.Inhibition of HDAC3 Promotes Psoriasis Development in Mice Through Regulating Th17
Fan XU ; Xin-Rui ZHANG ; Yang-Chen XIA ; Wen-Ting LI ; Hao CHEN ; An-Qi QIN ; Ai-Hong ZHANG ; Yi-Ran ZHU ; Feng TIAN ; Quan-Hui ZHENG
Progress in Biochemistry and Biophysics 2025;52(4):1008-1017
ObjectiveTo investigate the influence of histone deacetylase 3 (HDAC3) on the occurrence, development of psoriasis-like inflammation in mice, and the relative immune mechanisms. MethodsHealthy C57BL/6 mice aged 6-8 weeks were selected and randomly divided into 3 groups: control group (Control), psoriasis model group (IMQ), and HDAC3 inhibitor RGFP966-treated psoriasis model group (IMQ+RGFP966). One day prior to the experiment, the back hair of the mice was shaved. After a one-day stabilization period, the mice in Control group was treated with an equal amount of vaseline, while the mice in IMQ group was treated with imiquimod (62.5 mg/d) applied topically on the back to establish a psoriasis-like inflammation model. The mice in IMQ+RGFP966 group received intervention with a high dose of the HDAC3-selective inhibitor RGFP966 (30 mg/kg) based on the psoriasis-like model. All groups were treated continuously for 5 d, during which psoriasis-like inflammation symptoms (scaling, erythema, skin thickness), body weight, and mental status were observed and recorded, with photographs taken for documentation. After euthanasia, hematoxylin-eosin (HE) staining was used to assess the effect of RGFP966 on the skin tissue structure of the mice, and skin thickness was measured. The mRNA and protein expression levels of HDAC3 in skin tissues were detected using reverse transcription real-time quantitative polymerase chain reaction (RT-qPCR) and Western blot (WB), respectively. Flow cytometry was employed to analyze neutrophils in peripheral blood and lymph nodes, CD4+ T lymphocytes, CD8+ T lymphocytes in peripheral blood, and IL-17A secretion by peripheral blood CD4+ T lymphocytes. Additionally, spleen CD4+ T lymphocyte expression of HDAC3, CCR6, CCR8, and IL-17A secretion levels were analyzed. Immunohistochemistry was used to detect the localization and expression levels of HDAC3, IL-17A, and IL-10 in skin tissues. ResultsCompared with the Control group, the IMQ group exhibited significant psoriasis-like inflammation, characterized by erythema, scaling, and skin wrinkling. Compared with the IMQ group, RGFP966 exacerbated psoriasis-like inflammatory symptoms, leading to increased hyperkeratosis. The psoriasis area and severity index (PASI) skin symptom scores were higher in the IMQ group than those in the Control group, and the scores were further elevated in the IMQ+RGFP966 group compared to the IMQ group. Skin thickness measurements showed a trend of IMQ+RGFP966>IMQ>Control. The numbers of neutrophils in the blood and lymph nodes increased sequentially in the Control, IMQ, and IMQ+RGFP966 groups, with a similar trend observed for CD4+ and CD8+ T lymphocytes in the blood. In skin tissues, compared with the Control group, the mRNA and protein levels of HDAC3 decreased in the IMQ group, but RGFP966 did not further reduce these expressions. HDAC3 was primarily located in the nucleus. Compared with the Control group, the nuclear HDAC3 content decreased in the skin tissues of the IMQ group, and RGFP966 further reduced nuclear HDAC3. Compared with the Control and IMQ groups, RGFP966 treatment decreased HDAC3 expression in splenic CD4+ and CD8+ T cells. RGFP966 treatment increased the expression of CCR6 and CCR8 in splenic CD4+ T cells and enhanced IL-17A secretion by peripheral blood and splenic CD4+ T lymphocytes. Additionally, compared with the IMQ group, RGFP966 reduced IL-10 protein levels and upregulated IL-17A expression in skin tissues. ConclusionRGFP966 exacerbates psoriatic-like inflammatory responses by inhibiting HDAC3, increasing the secretion of the cytokine IL-17A, and upregulating the expression of chemokines CCR8 and CCR6.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Effect of Shenfu injection on acute lung injury in hemorrhagic shock rats
Gaihong LIU ; Dongbin ZHANG ; Jiafu JI ; Shangkun SI ; Fan SU ; Yingxue XU ; Yong-Liang CHI ; Xiaoqian YI
The Journal of Clinical Anesthesiology 2024;40(1):73-79
Objective To observe the effect of Shenfu injection on lung injury caused by hemor-rhagic shock(HS)in rats and explore the related potential mechanism.Methods Thirty-six SPF healthy male SD rats,aged 16-17 weeks,weighing 400-600 g,were randomly divided into three groups:sham op-eration group(group SH),HS group(group HS),and Shenfu injection group(group SF),12 rats in each group.In group SH,only the right femoral vein and femoral artery were separated after anesthesia,and ve-nous catheterization was not performed.HS model was established in groups SF and HS.In group HS,liquid resuscitation was performed through an intravenous catheter,and the resuscitation fluid consisted of the auto-blood lost and the compound sodium chloride injection equivalent to 1.5 times the blood loss and 10 ml/kg normal saline.In group SF,the resuscitation fluid consisted of the lost autoblood and the compound sodium chloride injection equivalent to 1.5 times the blood loss and Shenfu injection 10 ml/kg.The whole perfusion time was about 60 minutes.Six rats in the three groups were randomly anesthetized 24 and 48 hours after op-eration.The wet/dry weight ratio(W/D)of lung tissues was detected.The concentrations of interleukin-6(IL-6),IL-17,IL-10,and transforming growth factor-β(TGF-β)were detected by ELISA,the mRNA ex-pression of retinoic acid-related orphan nuclear receptor γt(RORγt),transcription factor forkhead box pro-tein 3(Foxp3),and hypoxia-inducible factor-1α(HIF-1α)in lung tissues were detected by PCR.The pro-tein contents of RORγt,Foxp3,HIF-1α,aquaporin 1(AQP1),and AQP5 in lung tissue were detected by Western blot.Pathological changesunder HE staining light microscope and lung injury scores were observed.Results Compared with 24 hours after operation,W/D,the concentrations of IL-6 and IL-17,mRNA ex-pression and protein content of RORγt and HIF-1α,and lung injury score were significantly decreased(P<0.05),the concentrations of IL-10,and TGF-β,Foxp3 mRNA expression and protein content,and AQP1 protein content were significantly increased in group SF 48 hours after operation(P<0.05).Compared with group SH,W/D,the concentrations of IL-6,IL-17,IL-10,and TGF-β,mRNA expression and protein content of RORγt,Foxp 3,and HIF-1α,and lung injury score were significantly increased(P<0.05),AQP1 and AQP5 protein contents were significantly decreased in groups HS and SF 24 and 48 hours after operation(P<0.05),and alveolar structure was damaged under light microscope and alveolar interstitium was filled with a large amount of edematous fluid,during which a large number of inflammatory cells infiltra-ted.Compared with group HS,W/D,the concentrations of IL-6 and IL-17,mRNA expression and protein content of RORγt and HIF-1α,and lung injury score were significantly decreased(P<0.05),the concen-trations of IL-10 and TGF-β,Foxp3 mRNA expression and protein content,AQP1 and AQP5 protein con-tents were significantly increased in group SF 24 and 48 hours after surgery(P<0.05),and the alveolar structure was improved under light microscope,and edema was reduced,and the number of inflammatory cells was reduced.Conclusion Shenfu injection can regulate the balance between pro-inflammatory factors IL-6 and IL-17,and anti-inflammatory factors IL-10 and TGF-β,increase the protein content of AQP1 and AQP5 in lung tissue,and decrease the W/D and injury score in lung tissue,thus alleviating lung injury in HS rats.The mechanism may be related to the regulation of HIF-1α-RORγt/Foxp3 balance.
9.Interactions Between Intelligent Animals and Electronic Technology: Current State and Future Prospects
Jin-Jing ZHAO ; Yang-Fan ZHOU ; Bing-Ao ZHANG ; Ming YI ; Hong JIANG ; Sheng-Yong XU
Progress in Biochemistry and Biophysics 2024;51(4):890-911
Human-animal interaction has a long-standing tradition dating back to ancient times. With the rapid advancements in intelligent chips, wearable devices, and machine algorithms, the intelligent interaction between animals and electronic technology, facilitated by electronic devices and systems for communication, perception, and control, has become a reality. These electronic devices aim to implement an animal-centric working mode to enhance human understanding of animals and promote the development of animal intelligence and creativity. This article takes medium-sized and large animals as research objects, with the goal of developing their ability enhancement, and introduces the concept of “intelligent animal augmentation system (IAAS)”. This concept is used to describe the characteristics of such devices and provides a comprehensive overview of existing animal and computer interface solutions. In general, IAAS can be divided into implantable and non-implantable types, each composed of interface platforms, perception and interpretation, control and instruction components. Through various levels of enhancement systems and architectural patterns, intelligent interaction between humans and animals can be realized. Although existing IAAS still lack a complete independent interaction system architecture, they hold great promise and development space in the future. Not only can they be applied as substitutes for cutting-edge devices and transportation equipment, but they are also expected to achieve cross-species information interaction through intelligent interconnection. Additionally, IAAS can promote bidirectional interaction between humans and animals, playing a significant role in advancing animal ethics and ecological protection. Furthermore, the development of interaction models based on animal subjects can provide insightful research experiences for the design of human-computer interaction systems, thereby contributing to the more efficient realization of the ambitious goal of human-machine integration.
10.Effect of Sargassum and Glycyrrhizae Radix et Rhizoma Incompatible Pair with Haizao Yuhutang on Oxidative Stress in Liver of Goiter Rats
Xiao DONG ; Yi TIAN ; Xiaoqing LIU ; Can CAO ; Wenyong LIAO ; Xiangnan XU ; Meijing WU ; Haiyan LIU ; Shaohong CHEN ; Xue YU ; Angran FAN ; Linlin XIU ; Gansheng ZHONG
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(14):37-45
ObjectiveTo observe the effects of Sargassum and Glycyrrhizae Radix et Rhizoma incompatible pair with the Haizao Yuhutang (HYT) on oxidative stress in the liver of goiter rats under the condition of 2 times the dose limit of the Pharmacopoeia of the People's Republic of China 2020. MethodA total of 128 male Wistar rats were randomly divided into a blank group, a model group, a euthyrox group (20 μg·kg-1), a HYT group (12.06 g·kg-1), a HYT without Sargassum (HYT-H) group (9.90 g·kg-1), a HYT without Glycyrrhizae Radix et Rhizoma (HYT-G) group (10.26 g·kg-1), a HYT without Sargassum and Glycyrrhizae Radix et Rhizoma (HYT-HG) group (8.10 g·kg-1), and a Sargassum and Glycyrrhizae Radix et Rhizoma (HG) group (3.96 g·kg-1). The blank group was given deionized water by gavage, and the others were given propylthiouracil (PTU) to replicate the goiter pathological model. Euthyrox was taken as a positive control drug, and the rest of the Chinese medicine groups were given the corresponding decoction by gavage, the material was collected 12 hours after the last dose. The serum levels of aspartate aminotransferase (AST), alanine aminotransferase (ALT), alkaline phosphatase (ALP), and the contents of superoxide dismutase (SOD), glutathione peroxidase (GSH-Px), malondialdehyde (MDA), reactive oxygen species (ROS) in liver tissue were detected in each group. The pathological changes in the liver were observed via hematoxylin-eosin (HE) staining. Real-time fluorescence quantitative polymerase chain reaction (Real-time PCR) was utilized to detect the mRNA expressions of Kelch-like Ech-associated protein 1 (Keap1), nuclear factor E2-related factor 2 (Nrf2), heme oxygenase-1 (HO-1), p53 and Caspase-3 in liver tissues. Western blot was adopted to detect the protein expressions of Nrf2 and HO-1 in liver tissues in oxidative stress-related signaling pathways. ResultCompared with control group, the model group showed significantly increased serum ALT level and contents of MDA and ROS in liver tissues (P<0.05, P<0.01), significantly reduced activities of SOD and GSH-Px in the liver (P<0.01), significantly increased mRNA expression of Keap1 (P<0.01), and significantly decreased mRNA and protein expressions of Nrf2 and HO-1 (P<0.05, P<0.01). Compared with the model group, the HYT group manifested significantly reduced serum levels of AST, ALT, and ALP (P<0.05, P<0.01), significantly reduced contents of MDA and ROS in liver tissue (P<0.01), significantly increased the activities of SOD and GSH-Px (P<0.01), significantly decreased mRNA expressions of Keap1, p53, and Caspase-3 (P<0.01), and significantly increased mRNA and protein expressions of Nrf2 and HO-1 (P<0.05, P<0.01). ConclusionUnder the condition of 2 times the dose limit of the Pharmacopoeia of the People's Republic of China 2020, Sargassum and Glycyrrhizae Radix et Rhizoma incompatible pair with the HYT on oxidative stress in the liver of goiter rats had different effects. The HYT that contains Sargassum and Glycyrrhizae Radix et Rhizoma has a protective effect on the liver of goiter rats, and the effect is better than that of the HG group, the euthyrox group, and the incomplete groups. Its mechanism may be related to activating the Nrf2/HO-1 signaling pathway to alleviate liver oxidative stress and inhibiting the p53/Caspase-3 signaling pathway to reduce hepatocyte apoptosis.


Result Analysis
Print
Save
E-mail