1.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
2.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
3.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
4.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
5.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
6.A Nationwide Study on HER2-Low Breast Cancer in South Korea: Its Incidence of 2022 Real World Data and the Importance of Immunohistochemical Staining Protocols
Min Chong KIM ; Eun Yoon CHO ; So Yeon PARK ; Hee Jin LEE ; Ji Shin LEE ; Jee Yeon KIM ; Ho-chang LEE ; Jin Ye YOO ; Hee Sung KIM ; Bomi KIM ; Wan Seop KIM ; Nari SHIN ; Young Hee MAENG ; Hun Soo KIM ; Sun Young KWON ; Chungyeul KIM ; Sun-Young JUN ; Gui Young KWON ; Hye Jeong CHOI ; So Mang LEE ; Ji Eun CHOI ; Ae Ri AN ; Hyun Joo CHOI ; EunKyung KIM ; Ahrong KIM ; Ji-Young KIM ; Jeong Yun SHIM ; Gyungyub GONG ; Young Kyung BAE
Cancer Research and Treatment 2024;56(4):1096-1104
Purpose:
Notable effectiveness of trastuzumab deruxtecan in patients with human epidermal growth factor receptor 2 (HER2)–low advanced breast cancer (BC) has focused pathologists’ attention. We studied the incidence and clinicopathologic characteristics of HER2-low BC, and the effects of immunohistochemistry (IHC) associated factors on HER2 IHC results.
Materials and Methods:
The Breast Pathology Study Group of the Korean Society of Pathologists conducted a nationwide study using real-world data on HER2 status generated between January 2022 and December 2022. Information on HER2 IHC protocols at each participating institution was also collected.
Results:
Total 11,416 patients from 25 institutions included in this study. Of these patients, 40.7% (range, 6.0% to 76.3%) were classified as HER2-zero, 41.7% (range, 10.5% to 69.1%) as HER2-low, and 17.5% (range, 6.7% to 34.0%) as HER2-positive. HER2-low tumors were associated with positive estrogen receptor and progesterone receptor statuses (p < 0.001 and p < 0.001, respectively). Antigen retrieval times (≥ 36 minutes vs. < 36 minutes) and antibody incubation times (≥ 12 minutes vs. < 12 minutes) affected on the frequency of HER2 IHC 1+ BC at institutions using the PATHWAY HER2 (4B5) IHC assay and BenchMark XT or Ultra staining instruments. Furthermore, discordant results between core needle biopsy and subsequent resection specimen HER2 statuses were observed in 24.1% (787/3,259) of the patients.
Conclusion
The overall incidence of HER2-low BC in South Korea concurs with those reported in previously published studies. Significant inter-institutional differences in HER2 IHC protocols were observed, and it may have impact on HER2-low status. Thus, we recommend standardizing HER2 IHC conditions to ensure precise patient selection for targeted therapy.
7.Influence of Band and Loop Type Space Maintainer on Intraoral Scanning Accuracy of an Adjacent Tooth
Ju Ri YE ; Yong Kwon CHAE ; Ko Eun LEE ; Hyo-Seol LEE ; Sung Chul CHOI ; Ok Hyung NAM
Journal of Korean Dental Science 2023;16(2):149-155
Purpose:
The purpose of this study was to evaluate whether the presence of a space maintainer affects the accuracy of an intraoral scanner.
Materials and Methods:
The maxillary primary first molar typodont tooth was removed from the primary dentition typodont model and a band and loop type space maintainer was delivered. After the model was connected to a dental phantom, intraoral scan was performed using TRIOS 4 (3Shape A/S, Copenhagen, Denmark). The scan was repeated with the same technique without the space maintainer. Each scan was performed 10 times. All scan files into a GOM inspect 2018 software and evaluated the accuracy. The accuracy was evaluated on trueness and precision, and calculated using the root mean square value.Result: When there was a space maintainer in the oral cavity, the trueness value was 0.10±0.02 mm and the precision value was 0.15±0.03 mm. In the absence of the space maintainer, the trueness value was 0.12±0.03 mm and the precision value was 0.16±0.04 mm. There were no significant differences depending on the presence of a space maintainer (P>0.05).
Conclusion
Within the limits of this study, the accuracy of the intraoral scanner was not influenced by the presence of space maintainer.
8.Shinjulactone A Blocks Vascular Inflammation and the EndothelialMesenchymal Transition
Ye-eun JANG ; Jenita IMMANUEL ; Jin-ri LEE ; Yu-jin JANG ; Yun Ju KWON ; Hyun Sook KWON ; Jung-Woog SHIN ; Sanguk YUN
Journal of Lipid and Atherosclerosis 2022;11(3):272-279
Objective:
The endothelial inflammatory response plays an important role in atherogenesis by inducing nuclear factor (NF)κB-dependent cell adhesion molecule expression and monocyte recruitment. Here, we screened for natural ligands and investigated the ability of shinjulactone A to inhibit interleukin-1β (IL-1β)-induced endothelial inflammatory signaling.
Methods:
The natural compound library included 880 single compounds isolated from medicinal plants by the Korean Medicinal Material Bank. Primary endothelial cells were pretreated with single compounds before stimulation with IL-1β to induce endothelial inflammation. Endothelial inflammation was measured by assaying NFκB activation and monocyte adhesion. The endothelial-mesenchymal transition (EndMT) was evaluated using cell type-specific marker protein expression and morphology.
Results:
Shinjulactone A was identified as an efficient blocker of IL-1β -induced NFκB activation, with a half-maximal inhibitory concentration of approximately 1 µM, and monocyte recruitment in endothelial cells. However, it did not affect lipopolysaccharideinduced NFκB activation in macrophages. Compared to Bay 11-782, a well-known NFκB inhibitor that shows considerable cytotoxicity during long-term treatment, shinjulactone A did not affect endothelial cell viability. Furthermore, it also significantly inhibited the EndMT, which is known to promote atherosclerosis and plaque instability.
Conclusion
We suggest that shinjulactone A may be an effective and safe drug candidate for atherosclerosis because it targets and inhibits both endothelial inflammation and the EndMT, without impairing NFκB-dependent innate immunity in macrophages.
9.The Immediate Effects of Dynamic Stretching and Static Stretching Using a Wedge Board on the Balance Ability and Jump Function of Healthy Adult
Ye-ri JI ; Yoo-sun HONG ; Dongyeop LEE ; Ji-Heon HONG ; Jae-Ho YU ; Jin-Seop KIM ; Seong-gil KIM
Journal of Korean Physical Therapy 2021;33(6):286-291
Purpose:
This study aims to measure the improvement of balanced ability and rapid response of 30 healthy adults by performing dynamic stretching, static stretching, and sargent jump.
Methods:
The sample 30 peoples without any musculoskeletal disease who volunteered to be the subject of the study. We measured all subjects on following metrics to evaluate the function and stability under the normal condition, with dynamic stretching (DS) group, static stretching (SS) group: vertical jump height and reaching distance Anterior, Posteromedial, Posterolateral and NO (Normal eye open), NC (Normal eye close), PO (Pillow with eye open), and PC (Pillow with close eye) were evaluated. All measures were analyzed using independent t-test and One-way repeated Anova.
Results:
There was a significant increase in SJH (Sargent jump) in both groups (p < 0.05). In Y-balance test, there was a significant increase in both groups except for the ANT (Anterior) direction, and there was a significant increase only in the SS group in the ANT (Anterior) direction (p < 0.05). There was no significant difference between the DS group and the SS group (p > 0.05). There was no significant improvement in ST (Stability Index) and WDI (Weight Distribution Index) in both groups (p > 0.05).
Conclusion
Both DS and SS showed significant improvement in SJH and Y-balance tests, which are dynamic functions, but had no significant effect on static balance ability.
10.The autophagy Protein Atg5 Plays a Crucial Role in the Maintenance and Reconstitution Ability of Hematopoietic Stem Cells
Hi Eun JUNG ; Ye Ri SHIM ; Ji Eun OH ; Dong Sun OH ; Heung Kyu LEE
Immune Network 2019;19(2):e12-
Hematopoietic stem cells (HSCs) in bone marrow are pluripotent cells that can constitute the hematopoiesis system through self-renewal and differentiation into immune cells and red blood cells. To ensure a competent hematopoietic system for life, the maintenance of HSCs is tightly regulated. Although autophagy, a self-degradation pathway for cell homeostasis, is essential for hematopoiesis, the role of autophagy key protein Atg5 in HSCs has not been thoroughly investigated. In this study, we found that Atg5 deficiency in hematopoietic cells causes survival defects, resulting in severe lymphopenia and anemia in mice. In addition, the absolute numbers of HSCs and multiple-lineage progenitor cells were significantly decreased, and abnormal erythroid development resulted in reduced erythrocytes in blood of Vav_Atg5(−/−) mice. The proliferation of Lin⁻Sca-1⁺c-Kit⁺ HSCs was aberrant in bone marrow of Vav_Atg5(−/−) mice, and mature progenitors and terminally differentiated cells were also significantly altered. Furthermore, the reconstitution ability of HSCs in bone marrow chimeric mice was significantly decreased in the presence of Atg5 deficiency in HSCs. Mechanistically, impairment of autophagy-mediated clearance of damaged mitochondria was the underlying cause of the HSC functional defects. Taken together, these results define the crucial role of Atg5 in the maintenance and the reconstitution ability of HSCs.
Anemia
;
Animals
;
Autophagy
;
Bone Marrow
;
Erythrocytes
;
Hematopoiesis
;
Hematopoietic Stem Cells
;
Hematopoietic System
;
Homeostasis
;
Lymphopenia
;
Mice
;
Mitochondria
;
Stem Cells

Result Analysis
Print
Save
E-mail