1.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
2.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
3.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
4.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
5.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
6.Analysis of component composition and content determination of six constituents for Xeriga-4 Powder
Jun LI ; Yue-Wu WANG ; Qian ZHANG ; Ping CUI ; Ri-Gui YE ; Ji-ri-mu-ba-tu
Chinese Traditional Patent Medicine 2024;46(1):14-22
AIM To analyze the component composition of Xeriga-4 Powder,and to determine the contents of phellodendrine,chlorogenic acid,gardenoside,berberine,rutin and curcumin.METHODS The high performance liquid chromatography-Q-exactive orbitrap mass spectrometry(HPLC-Q-Exactive-MS)qualitative analysis was performed on a 35℃thermostatic Agilent ZORBAX SB-Aq column(4.6 mm×150 mm,5 μm),with the mobile phase comprising of methanol-0.1%formic acid flowing at 0.35 mL/min in a gradient elution manner,and electron spray ionization source was adopted in positive and negative ion scanning.High performance liquid chromatography tandem mass spectrometry(HPLC-MS/MS)quantitative analysis was performed on a 35℃thermostatic Shim-pack GIST-HP C18 column(2.1 mm×100 mm,3 μm),with the mobile phase comprising of methanol-0.1%formic acid flowing at 0.25 mL/min in a gradient elution manner,and electron spray ionization source was adopted in positive and negative ion scanning with multiple reaction monitoring mode.RESULTS Total 65 constituents were identified,containing 19 alkaloids,13 organic acids,13 flavonoids,7 curcumins,6 iridoids,4 fatty acids,2 aldehydes,and 1 amino acid.Six constituents showed good linear relationships within their own ranges(r≥0.999 1),whose average recoveries were 96.44%-102.37%with the RSDs of 2.05%-3.74%.CONCLUSION This study can provide a reference for the quality control for Xieriga-4 Powder.
7.A Nationwide Study on HER2-Low Breast Cancer in South Korea: Its Incidence of 2022 Real World Data and the Importance of Immunohistochemical Staining Protocols
Min Chong KIM ; Eun Yoon CHO ; So Yeon PARK ; Hee Jin LEE ; Ji Shin LEE ; Jee Yeon KIM ; Ho-chang LEE ; Jin Ye YOO ; Hee Sung KIM ; Bomi KIM ; Wan Seop KIM ; Nari SHIN ; Young Hee MAENG ; Hun Soo KIM ; Sun Young KWON ; Chungyeul KIM ; Sun-Young JUN ; Gui Young KWON ; Hye Jeong CHOI ; So Mang LEE ; Ji Eun CHOI ; Ae Ri AN ; Hyun Joo CHOI ; EunKyung KIM ; Ahrong KIM ; Ji-Young KIM ; Jeong Yun SHIM ; Gyungyub GONG ; Young Kyung BAE
Cancer Research and Treatment 2024;56(4):1096-1104
Purpose:
Notable effectiveness of trastuzumab deruxtecan in patients with human epidermal growth factor receptor 2 (HER2)–low advanced breast cancer (BC) has focused pathologists’ attention. We studied the incidence and clinicopathologic characteristics of HER2-low BC, and the effects of immunohistochemistry (IHC) associated factors on HER2 IHC results.
Materials and Methods:
The Breast Pathology Study Group of the Korean Society of Pathologists conducted a nationwide study using real-world data on HER2 status generated between January 2022 and December 2022. Information on HER2 IHC protocols at each participating institution was also collected.
Results:
Total 11,416 patients from 25 institutions included in this study. Of these patients, 40.7% (range, 6.0% to 76.3%) were classified as HER2-zero, 41.7% (range, 10.5% to 69.1%) as HER2-low, and 17.5% (range, 6.7% to 34.0%) as HER2-positive. HER2-low tumors were associated with positive estrogen receptor and progesterone receptor statuses (p < 0.001 and p < 0.001, respectively). Antigen retrieval times (≥ 36 minutes vs. < 36 minutes) and antibody incubation times (≥ 12 minutes vs. < 12 minutes) affected on the frequency of HER2 IHC 1+ BC at institutions using the PATHWAY HER2 (4B5) IHC assay and BenchMark XT or Ultra staining instruments. Furthermore, discordant results between core needle biopsy and subsequent resection specimen HER2 statuses were observed in 24.1% (787/3,259) of the patients.
Conclusion
The overall incidence of HER2-low BC in South Korea concurs with those reported in previously published studies. Significant inter-institutional differences in HER2 IHC protocols were observed, and it may have impact on HER2-low status. Thus, we recommend standardizing HER2 IHC conditions to ensure precise patient selection for targeted therapy.
8.Influence of Band and Loop Type Space Maintainer on Intraoral Scanning Accuracy of an Adjacent Tooth
Ju Ri YE ; Yong Kwon CHAE ; Ko Eun LEE ; Hyo-Seol LEE ; Sung Chul CHOI ; Ok Hyung NAM
Journal of Korean Dental Science 2023;16(2):149-155
Purpose:
The purpose of this study was to evaluate whether the presence of a space maintainer affects the accuracy of an intraoral scanner.
Materials and Methods:
The maxillary primary first molar typodont tooth was removed from the primary dentition typodont model and a band and loop type space maintainer was delivered. After the model was connected to a dental phantom, intraoral scan was performed using TRIOS 4 (3Shape A/S, Copenhagen, Denmark). The scan was repeated with the same technique without the space maintainer. Each scan was performed 10 times. All scan files into a GOM inspect 2018 software and evaluated the accuracy. The accuracy was evaluated on trueness and precision, and calculated using the root mean square value.Result: When there was a space maintainer in the oral cavity, the trueness value was 0.10±0.02 mm and the precision value was 0.15±0.03 mm. In the absence of the space maintainer, the trueness value was 0.12±0.03 mm and the precision value was 0.16±0.04 mm. There were no significant differences depending on the presence of a space maintainer (P>0.05).
Conclusion
Within the limits of this study, the accuracy of the intraoral scanner was not influenced by the presence of space maintainer.
9.Phytochemical Study on the Aerial Parts of Codonopsis lanceolata
Ye Dam NOH ; So-Ri SON ; Min Goo JUN ; Dae Sik JANG
Natural Product Sciences 2023;29(4):200-205
Codonopsis lanceolata, which is predominantly found in Korea and East Asia, has attracted considerable scientific attention due to its long-standing use in traditional medicine. However, despite both its roots and stems being utilized as functional food and medicinal resources, there has been limited phytochemical investigation into its aerial parts. Therefore, the aim of this study is to isolate compounds present in the aerial parts of C. lanceolata. Through repeated chromatography, two alkaloids (1 and 2), seven flavones (3-9), and three isoflavones (10-12) and one type of phenylpropanoid (13) and polyacetylene (14) were isolated from a 70% ethanol extract of C. lanceolata. The structure of each compound was determined through the analysis of spectroscopic data ( 1 H and 13 C NMR), and by comparing them with previous research results. Among the isolates, the presence of methyl 2-formyl-5-(methoxymethyl)-1H-pyrrole-1-butanoate (1), chrysoeriol 5-O-β-D-glucopyranoside (3), apigenin-5-O-β-D-glucopyranoside (5), and 3′-O-methylorobol 7-O-β-D-glucopyranoside (12) were reported for the first time in plants belonging to the Campanula family in this study. In addition, the current study marked the isolation of luteolin 4′-O-β-D-glucopyranoside (4) from C. lanceolata for the first time.
10.Changes in body composition, body balance, metabolic parameters and eating behavior among overweight and obese women due to adherence to the Pilates exercise program
Hyun Ju KIM ; Jihyun PARK ; Mi Ri HA ; Ye Jin KIM ; Chaerin KIM ; Oh Yoen KIM
Journal of Nutrition and Health 2022;55(6):642-655
Purpose:
We examined the effects of the 8-week moderate-intensity Pilates exercise program on body composition, balance ability, metabolic parameters, arterial condition, and eating habits among overweight and obese women.
Methods:
From the general sample of overweight or obese Korean women (body mass index ≥ 23 kg/m2 ), those who had not been diagnosed with any chronic degenerative diseases were enrolled in the study (n = 39). After 8 weeks of the Pilates exercise program, the participants were subdivided into adherence and non-adherence groups. Among the study participants, 24 women were matched for age and menopausal status to reduce the bias, and then finally included for the comparison (Pilates-adherence, n = 12; Pilates-non-adherence, n = 12).
Results:
The body balance measured by the Y-balance test, body mass index, and subcutaneous fat areas were significantly improved in both groups. However, the Pilatesadherence group showed more positive changes in body balance and had significant improvement in body composition parameters such as waist size, visceral fat area, systolic blood pressure, arterial aging index, fasting blood glucose, and glycated hemoglobin than the Pilates-non-adherence group. In addition, the nutrition quotient for Korean adults (balance,moderation, and behavior except diversity) were significantly improved in both groups after dietary education. However, the participants did not show dramatic improvement in the metabolic parameters, because all the study subjects were in relatively good health and did not have any diagnosed diseases.
Conclusion
This study demonstrated that higher adherence to the Pilates exercise program together with a modification of eating habits may effectively improve body balance, body composition, and obesity-related parameters among overweight and obese women.

Result Analysis
Print
Save
E-mail