1.Research progress in assisting in the diagnosis of early Alzheimer's disease through eye structure
Xuan HAN ; Jinyan WANG ; Qi ZHOU ; Xiaojuan SU ; Xingyu GUO ; Chunmeng LIU ; Jie CHEN ; Hejiang YE
International Eye Science 2024;24(1):77-81
Alzheimer's disease(AD)is a common degenerative disease of the central nervous system in which neuropathological changes precede cognitive dysfunction and behavioral impairment. Currently, early diagnosis of AD is based on invasive and expensive testing techniques that are difficult to use widely in the clinical setting. Therefore, there is an urgent need for new markers to detect AD at an early stage. The eye, as an extension of the brain, has been found to show earlier onset of ocular pathologic changes in patients with AD compared to brain pathologic changes, such as retinal structural abnormalities, visual dysfunction, retinal abnormal protein accumulation, choroidal thickness changes, decreased corneal nerve fiber density, deposition of abnormal Aβ proteins in the lens, and pupillary light decreased sensitivity of response, etc. This article reviews the ocular pathologic changes in AD patients in recent years to provide new ideas for the early clinical diagnosis of AD.
2.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
3.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
4.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
5.Clinical trial of lanthanum carbonate and calcium carbonate in the treatment of maintenance hemodialysis patients with end-stage renal disease
Xu-Xiang MA ; Han WANG ; Xiao-Ying ZONG ; Yu-Ye ZHOU ; Miao-Miao SANG
The Chinese Journal of Clinical Pharmacology 2024;40(18):2665-2669
Objective To explore the differences in curative effect of lanthanum carbonate and calcium carbonate on hyperphosphatemia in patients with end-stage renal disease(ESRD)after maintenance hemodialysis(MHD).Methods Patients with hyperphosphatemia after MHD treatment of ESRD were divided into treatment group and control group.Treatment group was given lanthanum carbonate chewable tablet orally,250 mg each time,tid;the control group was given calcium carbonate chewable tablets orally,500 mg each time,bid.Both groups were treated continuously for 3 months.The clinical efficacy,calcium and phosphorus metabolism,vascular sclerosis indexes[brachial ankle pulse wave conduction velocity(baPWV),ankle brachial index(ABI),homocystine(Hcy)],serum renal function indexes[[32 microglobulin(β2-MG),serum creatinine(SCr),blood urea nitrogen(BUN)],serum inflammation indexes[hypersensitive C-reactive protein(hs-CRP),tumor necrosis factor-α(TNF-α),interleukin-6(IL-6)],and the safety was evaluated.Results There were 104 cases in the treatment group and 96 cases in the control group.After treatment,the effective rate of the treatment group was 94.23%(98 cases/104 cases)higher than that of the control group 85.42%(82 cases/96 cases),and the difference was statistically significant(P<0.05).After treatment,the serum phosphorus levels of treatment group and control group were(1.42±0.19)and(1.68±0.20)mmol·L-1,respectively;the serum calcium levels were(2.32±0.30)and(2.49±0.24)mmol·L-1,respectively;the product of calcium and phosphorus were(49.28±6.25)and(52.05±5.60)mg2·dL-2,respectively;the baPWV levels were(1 560.72±114.90)and(1 613.49±109.77)cm·s-1,respectively;ABI levels were 1.20±0.09 and 1.17±0.07,respectively;Hcy levels were(32.02±3.21)and(34.84±2.89)μmol·L-1,respectively.Compared with the control group,there were statistically significant differences in the above indexes in treatment groups(all P<0.05).After treatment,there was no significant difference in levels of renal function indexes(β2-MG,SCr,BUN)and inflammatory indexes(hs-CRP,TNF-α,IL-6)between the two groups(all P>0.05).The adverse drug reactions of the treatment group were mainly diarrhea and rash;and the adverse drug reactions of the control group were mainly diarrhea and hypercalcemia.The difference in incidence of adverse drug reactions between control group and treatment group was not statistically significant(2.88%vs 3.13%,P>0.05).Conclusion Compared with calcium carbonate,improvement effect of lanthanum carbonate is better on phosphorus and calcium-phosphorus metabolism in MHD patients with ESRD and hyperphosphatemia,which can delay the progression of vascular sclerosis.
6.Constructing predictive modelling for the risk of serious adverse cardiovascular events in postoperative patients of symptomatic arteriosclerosis obliterans
Ye JI ; Baoyan WANG ; Qinshu WEN ; Dan HAN ; Guangyan WU ; Yepeng ZHANG ; Min ZHOU
Chinese Journal of General Surgery 2024;39(3):197-202
Objective:To construct a predictive model for the risk of major adverse cardiovascular events(MACE) after surgery in patients with symptomatic arteriosclerosis obliterans(ASO) .Methods:From Jan 2018 to Dec 2021, 957 patients with symptomatic ASO admitted to Nanjing Drum Tower Hospital were selected and divided into MACE and non-MACE groups according to whether they had a post-op MACE. A risk prediction model was constructed based on a stepwise regression method with multi-factor COX regression analysis. The model was evaluated using the receiver operating characteristic curve (ROC), the calibration curve to assess the model fit, and the Bootstrap method for internal validation.Results:MACE occurred in 143 patients (14.94%). After COX regression analysis, BMI, creatinine clearance, fibrinogen, rivaroxaban and previous history of surgery were enrolled into model constructing. The ROC curve assessed the model with a C-statistic of 0.690 (95% CI: 0.644-0.736), sensitivity and specificity of 49.2% and 80.7% respectively, a Jorden index of 0.299 and an optimal cut-off value of 0.086. Calibration curves showing agreement between predicted and actual observed values. Internally validated C-statistic of 0.689 (95% CI: 0.672-0.700). The population was divided into high and low risk groups based on the best cut-off value and analysed for survival. The difference between the two groups was statistically different. Conclusion:The risk prediction model for the occurrence of MACE based on clinical parameters is simple and convenient, with good predictability and good discriminatory ability, and can provide reference for the assessment and treatment of MACE in ASO patients.
7.Expert consensus on surgical treatment of oropharyngeal cancer
China Anti-Cancer Association Head and Neck Oncology Committee ; China Anti-Cancer Association Holistic Integrative Oral Cancer on Preventing and Screen-ing Committee ; Min RUAN ; Nannan HAN ; Changming AN ; Chao CHEN ; Chuanjun CHEN ; Minjun DONG ; Wei HAN ; Jinsong HOU ; Jun HOU ; Zhiquan HUANG ; Chao LI ; Siyi LI ; Bing LIU ; Fayu LIU ; Xiaozhi LV ; Zheng-Hua LV ; Guoxin REN ; Xiaofeng SHAN ; Zhengjun SHANG ; Shuyang SUN ; Tong JI ; Chuanzheng SUN ; Guowen SUN ; Hao TIAN ; Yuanyin WANG ; Yueping WANG ; Shuxin WEN ; Wei WU ; Jinhai YE ; Di YU ; Chunye ZHANG ; Kai ZHANG ; Ming ZHANG ; Sheng ZHANG ; Jiawei ZHENG ; Xuan ZHOU ; Yu ZHOU ; Guopei ZHU ; Ling ZHU ; Susheng MIAO ; Yue HE ; Jugao FANG ; Chenping ZHANG ; Zhiyuan ZHANG
Journal of Prevention and Treatment for Stomatological Diseases 2024;32(11):821-833
With the increasing proportion of human papilloma virus(HPV)infection in the pathogenic factors of oro-pharyngeal cancer,a series of changes have occurred in the surgical treatment.While the treatment mode has been im-proved,there are still many problems,including the inconsistency between diagnosis and treatment modes,the lack of popularization of reconstruction technology,the imperfect post-treatment rehabilitation system,and the lack of effective preventive measures.Especially in terms of treatment mode for early oropharyngeal cancer,there is no unified conclu-sion whether it is surgery alone or radiotherapy alone,and whether robotic minimally invasive surgery has better func-tional protection than radiotherapy.For advanced oropharyngeal cancer,there is greater controversy over the treatment mode.It is still unclear whether to adopt a non-surgical treatment mode of synchronous chemoradiotherapy or induction chemotherapy combined with synchronous chemoradiotherapy,or a treatment mode of surgery combined with postopera-tive chemoradiotherapy.In order to standardize the surgical treatment of oropharyngeal cancer in China and clarify the indications for surgical treatment of oropharyngeal cancer,this expert consensus,based on the characteristics and treat-ment status of oropharyngeal cancer in China and combined with the international latest theories and practices,forms consensus opinions in multiple aspects of preoperative evaluation,surgical indication determination,primary tumor re-section,neck lymph node dissection,postoperative defect repair,postoperative complication management prognosis and follow-up of oropharyngeal cancer patients.The key points include:① Before the treatment of oropharyngeal cancer,the expression of P16 protein should be detected to clarify HPV status;② Perform enhanced magnetic resonance imaging of the maxillofacial region before surgery to evaluate the invasion of oropharyngeal cancer and guide precise surgical resec-tion of oropharyngeal cancer.Evaluating mouth opening and airway status is crucial for surgical approach decisions and postoperative risk prediction;③ For oropharyngeal cancer patients who have to undergo major surgery and cannot eat for one to two months,it is recommended to undergo percutaneous endoscopic gastrostomy before surgery to effectively improve their nutritional intake during treatment;④ Early-stage oropharyngeal cancer patients may opt for either sur-gery alone or radiation therapy alone.For intermediate and advanced stages,HPV-related oropharyngeal cancer general-ly prioritizes radiation therapy,with concurrent chemotherapy considered based on tumor staging.Surgical treatment is recommended as the first choice for HPV unrelated oropharyngeal squamous cell carcinoma(including primary and re-current)and recurrent HPV related oropharyngeal squamous cell carcinoma after radiotherapy and chemotherapy;⑤ For primary exogenous T1-2 oropharyngeal cancer,direct surgery through the oral approach or da Vinci robotic sur-gery is preferred.For T3-4 patients with advanced oropharyngeal cancer,it is recommended to use temporary mandibu-lectomy approach and lateral pharyngotomy approach for surgery as appropriate;⑥ For cT1-2N0 oropharyngeal cancer patients with tumor invasion depth>3 mm and cT3-4N0 HPV unrelated oropharyngeal cancer patients,selective neck dissection of levels ⅠB to Ⅳ is recommended.For cN+HPV unrelated oropharyngeal cancer patients,therapeutic neck dissection in regions Ⅰ-Ⅴ is advised;⑦ If PET-CT scan at 12 or more weeks after completion of radiation shows intense FDG uptake in any node,or imaging suggests continuous enlargement of lymph nodes,the patient should undergo neck dissection;⑧ For patients with suspected extracapsular invasion preoperatively,lymph node dissection should include removal of surrounding muscle and adipose connective tissue;⑨ The reconstruction of oropharyngeal cancer defects should follow the principle of reconstruction steps,with priority given to adjacent flaps,followed by distal pedicled flaps,and finally free flaps.The anterolateral thigh flap with abundant tissue can be used as the preferred flap for large-scale postoperative defects.
8.Trend of incidence rate of acute myocardial infarction in Tengzhou City, Shandong Province, from 2013 to 2021
Xin WANG ; Liyu ZHOU ; Yuluan XU ; Xinggui HAN ; Li CHENG ; Shujun YE ; Hongyu ZHU ; Jinguo HAN ; Zongyi WU ; Fengping ZHAO ; Fuzhong SI
Chinese Journal of Preventive Medicine 2024;58(10):1556-1561
The surveillance data of new cases of acute myocardial infarction (AMI) from January 1, 2013, to December 31, 2021, in Tengzhou City, Shandong Province, were used to analyze the incidence rate of AMI and its change trend among residents. The age and gender standardized incidence rate was calculated based on the 7th National Population Census 2020. The Cochran-Armitage trend test was used to analyze the trend of onset time and age. From 2013 to 2021, the crude and standardized incidence rate of total AMI in Tengzhou City declined from 130.07/100 000 and 161.12/100 000 to 76.15/100 000 and 72.77/100 000 ( Z=-13.785 and -20.822, both P<0.001). The crude and standardized incidence rates of males were higher than those of females. In 2016, males aged 45-54 years old and females aged 35-64 years old increased by 33.33%, 103.65%, 106.30%, and 95.75% compared to 2015, and the differences were statistically significant ( χ2=6.512, 4.965, 25.115, and 46.004, all P<0.05). The incidence rate of AMI in men aged<35 and 35-44 years old had an upward trend. From 2013 to 2021, the incidence rate of AMI decreased by 55.15% in urban areas and 36.59% in rural areas ( Z=-8.529 and -11.235, both P<0.001).
9.Genome-wide methylation profiling identified methylated KCNA3 and OTOP2 as promising diagnostic markers for esophageal squamous cell carcinoma
Yan BIAN ; Ye GAO ; Chaojing LU ; Bo TIAN ; Lei XIN ; Han LIN ; Yanhui ZHANG ; Xun ZHANG ; Siwei ZHOU ; Kangkang WAN ; Jun ZHOU ; Zhaoshen LI ; Hezhong CHEN ; Luowei WANG
Chinese Medical Journal 2024;137(14):1724-1735
Background::Early detection of esophageal squamous cell carcinoma (ESCC) can considerably improve the prognosis of patients. Aberrant cell-free DNA (cfDNA) methylation signatures are a promising tool for detecting ESCC. However, available markers based on cell-free DNA methylation are still inadequate. This study aimed to identify ESCC-specific cfDNA methylation markers and evaluate the diagnostic performance in the early detection of ESCC.Methods::We performed whole-genome bisulfite sequencing (WGBS) for 24 ESCC tissues and their normal adjacent tissues. Based on the WGBS data, we identified 21,469,837 eligible CpG sites (CpGs). By integrating several methylation datasets, we identified several promising ESCC-specific cell-free DNA methylation markers. Finally, we developed a dual-marker panel based on methylated KCNA3 and OTOP2, and then, we evaluated its performance in our training and validation cohorts. Results::The ESCC diagnostic model constructed based on KCNA3 and OTOP2 had an AUC of 0.91 [95% CI: 0.85–0.95], and an optimal sensitivity and specificity of 84.91% and 94.32%, respectively, in the training cohort. In the independent validation cohort, the AUC was 0.88 [95% CI: 0.83–0.92], along with an optimal sensitivity of 81.5% and specificity of 92.9%. The model sensitivity for stage I–II ESCC was 78.4%, which was slightly lower than the sensitivity of the model (85.7%) for stage III–IV ESCC. Conclusion::The dual-target panel based on cfDNA showed excellent performance for detecting ESCC and might be an alternative strategy for screening ESCC.
10.Comparative study of indigo carmine staining and white light endoscopy in detection rate of right hemicolonic polyp
Ping LIANG ; Yi YANG ; Chuan LIANG ; Weizhen ZHOU ; Ye YANG ; Hai MOU ; Sijing HAN
Chongqing Medicine 2024;53(8):1209-1213
Objective To compare the detection rate of right hemicolonic polyp between indigo carmine staining and white light endoscopy.Methods A total of 1052 patients with colonoscopic examination in Qing-baijiang District People's Hospital of Chengdu City from July 2022 to March 2023 were selected as the study subjects and divided into the indigo carmine staining group and white light endoscopy group,526 cases in each group.The right hemicolon was observed by indigo carmine staining and white light pattern respectively.The difference in the detection rate of right hemicolonic polyp was compared between the two detection methods. Results Compared with the white light endoscopic examination group,the detection rate of the right hemico-lonic polyp (41.6%),detection rate of the right hemicolon adenoma (20.9%),detection rate of wide basal ser-rated lesion (2.1%),detection rate of proliferative polyps (20.3%),detection rate of Paris type 0-Ⅱ (38.0%),detection rate of NICE 1 type (pale lesion,22.2%),detection rate of polyps with a diameter<5 mm (30.5%) and the consistency rate of pathological biopsy (86.4%),specificity (84.7%) and sensitivity (88.2%) in the indigo carmine staining group were higher,and the differences were statistically significant (P<0.05).There was no statistical difference in the duration of mirror withdrawal between the white light endoscopy group and the indigo carmine staining group (t=1.407,P=0.160).Conclusion The endoscopic examination with indigo carmine staining has a higher detection rate for right hemicolonic polyp,and is easier to detect micropolyps and flat polyps with pale color.


Result Analysis
Print
Save
E-mail