1.Analysis of the trend of radiological diagnostic examination frequency and the related influencing factors
Yongxian ZHANG ; Yantao NIU ; Tianliang KANG ; Yunfu LIU ; Liping XU ; Lin XU ; Senlin GUO ; Dandan LIU ; Binbin YU ; Junfang XIAN
Chinese Journal of Radiological Medicine and Protection 2024;44(1):29-35
Objective:To investigate the trend of radiological diagnostic examination frequency and the related influencing factors in a general hospital in recent four years.Methods:The hospital information system and the radiology information system were used to collect the information on the numbers of the outpatients, the emergency patients, and the inpatients and the radiology examination information from 2019 to 2022. The examination frequency and proportion of various imaging equipment were counted by using the perspective table of data, and the examination items and the proportion of the radiological diagnostic examinations were calculated. The positive rates of the radiological examinations were measured from 2019 to 2022. The gender and age distribution of the patients were analyzed. Spearman correlation analysis was used to analyze the relationships between the numbers of the patients undergoing radiological examinations and the numbers of the outpatients, emergency patients and the inpatients.Results:The annual frequency of radiological diagnostic examinations from 2019 to 2022 were 307 306, 245 418, 317 250 and 325 625, respectively, with a total of 1 195 599. Among them, the proportions of CT, X-rays, bedside X-rays, bone density, gastrointestinal imaging and mammography were 59.74%, 38.04%, 1.39%, 0.42%, 0.21% and 0.19%, respectively. In each year, the proportion of CT in all radiological diagnostic examinations was 49.58%, 63.40%, 60.40% and 65.20%, respectively. The frequency of emergency CT and emergency chest CT was correlated with the number of emergency patients( r =0.63, 0.61, P<0.05), and the frequency of non-emergency CT was correlated with the number of outpatients and inpatients ( r =0.61, 0.66, P<0.05). The positive rates of the CT examinations were higher than 80% except the lowest of 79.95% in 2021. Conclusions:Radiological examinations especially CT examinations have increased significantly, and played an important role in the diagnosis of diseases. However, attention should be paid to the Justification of the CT examinations. Timely statistical analysis of radiological examination information can provide data supports and references for scientific management of radiological examinations.
2.Application of Monte Carlo simulation in radiation dose estimation and optimization for diagnostic radiology
Zhijie ZHANG ; Yantao NIU ; Lihua ZHU ; Baohua SUN
Chinese Journal of Radiological Medicine and Protection 2024;44(2):151-157
The increasing frequency of radiographic diagnostic imaging and the cumulative dose to the public from radiation has raised widespread concerns. However, accurate measurement of the radiation dose received by the human body is difficult to achieve. Monte Carlo simulation, as a numerical computational method guided by probability statistics theory, has been applied to various dose assessments, imaging optimizations, and radiation protection in radiographic diagnostic imaging. We provide a comprehensive review of the principles of the Monte Carlo method, the modelling process of Monte Carlo simulation and the progress of its application to diagnostic radiological dose estimation.
3.A study on the dynamic and static functional connectivity changes of amygdala subregions in patients with bilateral idiopathic tinnitus and hearing loss based on fMRI
Yue SHI ; Lanyue CHEN ; Yi ZHANG ; Xiaobo MA ; Wei LI ; Xiaoxia QU ; Qian WANG ; Yantao NIU ; Zhaohui LIU
Chinese Archives of Otolaryngology-Head and Neck Surgery 2024;31(9):574-579
OBJECTIVE To observe the changes of static functional connectivity(sFC) and dynamic functional connectivity(dFC) of amygdala subregions in patients with bilateral idiopathic tinnitus and hearing loss(TINHL). METHODS The resting-state functional magnetic resonance imaging(fMRI) data of 30 patients with bilateral tinnitus and hearing loss and 37 normal controls(NCs) were collected to analyze the intensity changes of sFC and dFC in 8 subregions of amygdala and the whole brain in TINHL patients. RESULTS There were no significant differences in age,sex and education between the two groups. Compared with the NCs group,the sFC intensity of the right basolateral subregion and right cerebellar peduncle 1 region,the left basolateral subregion and left orbital medial frontal gyrus and left angular gyrus in TINHL group was significantly decreased. The dFC intensity of left amygdalostriatal subregion and left precuneus in TINHL group was increased,but the dFC intensity was reduced in the left basolateral subregion and right angular gyrus as well as between the right superficial subregion and right medial orbital of superior frontal gyrus. CONCLUSION Among the 8 subregions of amygdala,the bilateral basolateral subregions,the left amygdalostriatal subregion and the right superficial region shown abnormal functional connectivity with other regions of the brain,which are the important parts of emotional abnormalities in TINHL.
4.A controlled study on the impacts of different scanning protocols on image quality and radiation dose in chest CT
Chulin XU ; Wentao MA ; Yongxian ZHANG ; Yunfu LIU ; Tianliang KANG ; Senlin GUO ; Yantao NIU
Chinese Journal of Radiological Medicine and Protection 2024;44(9):789-796
Objective:To explore and compare the impacts of different scanning protocols on image quality and radiation dose in chest computed tomography (CT) scans.Methods:A retrospective analysis was conducted for the data of 65 randomly selected patients who underwent chest CT scans using a tube voltage of 120 kV, the automatic modulation technique for tube current, and z-axis radiation dose modulation at the Emergency Department of our hospital from June to July 2023. The enrolled cases were divided into two groups: the high-resolution group ( n = 34) and the conventional group ( n = 31), with the settings for scanning protocols identical to those for phantom scans. For patients in both groups, thin-layer images of the cross-sections in the lung and mediastinal windows were reconstructed using thickness/intervals of 1 mm/1 mm and 2 mm/1 mm, respectively. Meanwhile, high-resolution and conventional CT scans were conducted using a Catphan500 phantom under a tube voltage of 120 kV and a tube current of 150 mAs. Of both scanning protocols, the high-resolution CT scan utilized the lung nodule-orientated scanning mode, pitch of 1.5, and a detector combination providing a collimation of 16 × 0.75 mm. In contrast, the conventional CT scan was performed using the body-orientated scanning mode, pitch of 0.813, and a detector combination providing a collimation of 16 × 1.5 mm. Then, the high-contrast resolutions of the phantom images obtained using the two scanning protocols were objectively evaluated. Both coronal chest images in the lung window and cross-sectional images in the mediastinal window were reconstructed with a thickness/interval of 5 mm/5 mm for both groups. Then, the obtained images were imported into the Radimetrics system to compare the body size-specific dose estimation (SSDE), doses to sensitive organs on the body surface, and scanning time of both groups. For the cross-sectional images in the mediastinal window, the contrast-noise-ratio (CNR), signal-to-noise ratio (SNR), and figure-of-merit (FOM) were measured and calculated at the fixed anatomical parts. For the cross-sectional images in the lung window, their quality was subjectively evaluated by two senior diagnostic radiologists. Results:The result of phantom scans indicated that high-resolution CT scans yielded images with an approximately 5% increase in the spatial resolution in the xy-plane and a nearly 20% increase in the spatial resolution along the z-axis compared to conventional CT scans. The result of clinical data demonstrated that the conventional group exhibited significantly higher doses to the thyroid and the female breast ( t = 2.8, 2.3, P < 0.05), along with notably elevated SNR, CNR, and FOM values of the right trapezius, compared to the high-resolution group ( t = 4.1, 5.8, z=4.4, P < 0.001). However, the high-resolution group manifested significantly higher SNR, CNR, and FOM values of the thoracic aorta compared to the conventional group ( t = 3.4, 4.4, z=3.4, P < 0.001). In addition, the cross-sectional and coronal images in the lung window of the clinical cases in the high-resolution group exhibited more stable quality, with subjective scores exceeding 4 and the average scores of both groups not statistically significantly different. Conclusions:For chest CT examination, high-resolution CT scans are more suitable for observations focusing on the details of the lungs and mediastinum, while conventional CT is more suitable for those centering on soft tissues on the body surface.
5.Study on the effect of virtual grid on chest X-ray image quality
Tianliang KANG ; Yunfu LIU ; Yongxian ZHANG ; Senlin GUO ; Wentao MA ; Yantao NIU
Chinese Journal of Radiology 2023;57(5):547-552
Objective:To explore the image quality and its evaluation method using virtual grid under different tube voltages in the clinical chest X-ray exam.Methods:According to the conditions of chest X-ray photography commonly used in clinical practice, the corresponding thickness of plexiglass (20 cm, including CDRAD phantom) was determined as the experimental object. With a fixed tube loading of 4 mAs and the tube voltage from 60 to 125 kV, the experimental object was imaged in three ways: physical grid, none grid and virtual grid. The common physical parameters (CNR, σ, C, SNR), texture analysis (Angular second moment, texture Contrast, Correlation, Inverse difference moment, Entropy) and CDRAD phantom score (IQF inv) were evaluated. Two-way ANOVA test was used for each group of common physical parameters, and further pairwise comparisons were made. At the same time, applying virtual grids on the obtained images with chest anthropomorphic model and texture indexing the images with and without virtual grids, then rank sum test of paired sample can be conducted. Results:There were differences in image quality among the three groups of grid mode( P<0.05), and the physical grid delivered the best image quality. The tube voltage had an impact on all image quality evaluation indexes ( P<0.05). The tube voltage was positively correlated with CNR, SNR, angular second moment, inverse difference moment and IQF inv ( P<0.05), and negatively correlated with σ, C, texture contrast and entropy ( P<0.05). There was no significant correlation between the tube voltage and Correlation ( P>0.05). The chest anthropomorphic model images were used to evaluate the virtual grids, and the texture indexes (Angle second moment, Contrast, Correlation, Inverse difference moment, Entropy) were statistically significant (P<0.05). Conclusions:The virtual grid can improve the image quality of chest X-ray photography, and the image texture analysis method can be a useful supplement to the image quality evaluation parameters.
6.The effect of CT detector width and signal acquisition positions on image quality
Senlin GUO ; Yue REN ; Yongxian ZHANG ; Tianliang KANG ; Yunfu LIU ; Lei ZHU ; Yantao NIU
Chinese Journal of Radiology 2023;57(6):684-688
Objective:To evaluate the influence of different detector widths and signal acquisition positions of wide-detector CT in different scanning modes on CT number and noise, and to provide a basis for reasonable selection of scanning modes and related parameters in clinical practice.Methods:The body dose phantom was scanned by GE Revolution CT. The scan was performed with detector widths of 40, 80 and 160 mm in sequential scanning mode and with detector width/pitch combinations of 40 mm/0.516, 40 mm/0.984, 80 mm/0.508 and 80 mm/0.992 in spiral scanning mode. The phantom was placed at the central and peripheral of the selected detector widths, and the adjacent positions between two axial scans. The images of the phantom were evaluated subjectively and the CT numbers and SDs were measured. The differences between the measured values at different imaging parameters were compared. The multi-group Friedman test was used to compare CT numbers and SD under different scanning parameters in sequential scanning mode, and the Wilcoxon test was used to compare CT numbers and SD in spiral scanning mode.Results:There was no statistically significant difference in the geometric shapes of the phantom images obtained at any combination of parameters. In sequential scanning mode, the differences at different detector widths were statistically significant (χ 2=14.00, P=0.001) with CT numbers at 40 mm and 160 mm greater than CT numbers at 80 mm ( P<0.05). The differences at different signal acquisition positions were statistically significant (χ 2=12.04, P=0.002) with CT numbers at peripheral and adjacent greater than CT numbers at central ( P<0.05). In spiral scanning mode CT numbers at detector width at 80 mm were greater than CT numbers at 40 mm ( Z=-2.10, P=0.036). For SD, the differences at different detector widths were statistically significant in sequential scanning modes (χ 2=8.17, P=0.017) with SD at 160 mm greater than SD at 80 mm ( P<0.05). The differences at different signal acquisition positions were statistically significant (χ 2=13.50, P=0.001) with SD at peripheral greater than SD at central ( P<0.05). In spiral scanning mode SDs at pitches 0.984 and 0.992 were greater than SDs at 0.516 and 0.508 ( Z=-2.66, P=0.008). There were no significant differences among other groups. Conclusion:The selection of scanning mode, detector width and signal acquisition position of wide-detector CT will affect the image CT numbers and SDs.
7.Effect of neck CT arteriovenous simultaneous enhancement methods on image quality and radiation dose
Yunfu LIU ; Tianliang KANG ; Yongxian ZHANG ; Senlin GUO ; Lin FU ; Qinggang XU ; Yingying CAO ; Junfang XIAN ; Yantao NIU
Chinese Journal of Radiology 2023;57(7):756-761
Objective:To investigate the feasibility of simultaneous arteriovenous enhancement of neck CT with two-stage injection of contrast agent and its effect on image quality and radiation dose.Methods:A total of 30 patients undergoing neck CT enhancement scan due to space-occupying lesions in Beijing Tongren Hospital, Capital Medical University from February to April 2022 were prospectively included as the experimental group. The neck CT enhancement scan was performed with two-stage injection of contrast agent and arteriovenous simultaneous enhancement. The dosage of contrast agent was calculated according to the patient′s body weight, and the method of two-stage injection was adopted. The dosage of contrast agent in the first stage was 0.7 ml/kg, with normal saline in the middle stage, and the second stage (began at 35 s) was 0.3 ml/kg. A total of 30 patients with gender and age matching with the experimental group from December 2021 to January 2022 were retrospectively collected as the control group. The control group was treated with the traditional arterial phase and venous phase scanning method with the dosage of 1.0 ml/kg contrast agent. The arterial phase was scanned at the 30 s and the venous phase was scanned at the 60 s. The CT values of bilateral carotid arteries and jugular veins in the experimental group were measured, the CT values of bilateral carotid arteries in the arterial phase were measured in the control group, and the CT values of bilateral carotid arteries and jugular veins in the venous phase were measured. Carotid artery enhancement score was performed for images of experimental group and control group in arterial and venous phase, and jugular vein and lesion enhancement score was performed for images of experimental group and control group in venous phase. The effective dose was calculated for both groups. The difference of carotid artery CT values between images was compared by one-way analysis of variance, and LSD method was used for pairwise comparison. The CT values of jugular vein were compared using independent sample t test. Kruskal-Wallis test was used to compare carotid artery enhancement scores, and Nemenyi method was used for pairwise comparison. Jugular vein and lesion enhancement scores and effective dose were compared by Mann-Whitney U test. Results:The CT value of carotid artery of experimental group [left (276±24) HU, right (273±25) HU] was lower than that of control group in arterial phase [left (329±33) HU, right (327±32) HU], and higher than that in the venous phase [left (147±15) HU, right (148±16) HU]. All the differences were statistically significant ( P<0.001). The CT value of jugular vein of experimental group [left (206±18) HU, right (203±19)] was higher than that of control group in the venous phase [left (154±15) HU, right (151±15)], the difference was statistically significant ( t=11.88, 11.76, both P<0.001). There was no significant difference in carotid artery enhancement score between experimental group and control group in arterial phase ( P=0.624), but the carotid artery enhancement score of the experimental group was higher than that of the control group in the venous phase, and the difference was statistically significant ( P<0.001). The scores of jugular vein and lesion enhancement in experimental group were higher than those of control group in venous phase, and the difference was statistically significant ( Z=5.01, P<0.001). The effective dose of the experimental group [2.41(2.04, 2.72) mSv] was decreased by 52.2% compared with the control group [5.04(4.18, 5.44) mSv], and the difference was statistically significant ( Z=-6.24, P<0.001). Conclusions:The neck CT enhanced scan with two-stage injection of contrast agent and arteriovenous simultaneous enhancement method can obtain comprehensive images of arterial and venous phases, and realize simultaneous enhancement of carotid artery, jugular vein and lesions, and reduce radiation dose.
8.The necessity and countermeasures of strengthening radiation dose management in diagnostic radiology
Yantao NIU ; Yongxian ZHANG ; Weihai ZHUO ; Jun DENG ; Hui XU ; Quanfu SUN
Chinese Journal of Radiological Medicine and Protection 2023;43(4):241-247
In recent years, the diagnostic radiology, especially CT scanning, has a rapidly increased frequency in our country, becoming the largest artificial radiation source to the average individual doses to the population. In clinical diagnosis and treatment activities, the examined patients and individuals may undergo multiple procedures and multiple frequencies of medical imaging in a short period of time and receive high cumulative radiation doses even exceeding 50 or 100 mSv in a single day, posing a potential risk to their health. Therefore, it is necessary to carry out statistical analysis and management of diagnostic radiation dose information to minimize the probability of excessive dose and associated radiation risk. In this paper, the international cognition of radiation risks in diagnostic radiology, diagnostic equipment and medical imaging frequency, radiation dose and its management status are described. Four countermeasures for radiation dose management are put forward to provide reference for further improving radiation protection in clinical practice.
9.Study on correlation between medical exposure and healthcare level in China
Shiyue CUI ; Yinping SU ; Hui XU ; Yantao NIU ; Weihai ZHUO ; Jianxiang LIU ; Jinsheng CHENG ; Quanfu SUN
Chinese Journal of Radiological Medicine and Protection 2023;43(6):440-446
Objective:To study the healthcare level (HCL) in China and its influencing factors.Methods:By using the data reported in the China statistical yearbook published by the National Bureau of Statistics and in other public literature, HCL was calculated in terms of the number of population and physicians in the whole country and various provinces. Multiple regression was used to analyze the relationship between HCL and regional population, area, number of administrative divisions and gross domestic product (GDP). Pearson correlation analysis was applied to analyze the relationship between healthcare level and medical radiation frequency. Results:Since 2015, Chinese HCL value was lower than 1 000, but there were two provinces with HCL value greater than 1 000 in 2019. Population and GDP were the influencing factors for the HCL, with correlation coefficients of 0.416 and -0.583, respectively. There was a correlation between HCL and medical exposure frequency of Chinese population( r= -0.620, P=0.028). Conclusions:Chinese HCL value was 542 in 2020, but there has been great differences between various provinces. HCL as an indicator of medical exposure assessment needs further research in China.
10.Regulation of miR-155 in H 2O 2-induced oxidative stress in lens epithelial cells via targeting SIRT1
Yantao NIU ; Li ZHANG ; Wenfang XIE
Chinese Journal of Experimental Ophthalmology 2022;40(5):404-413
Objective:To investigate the role of microRNA (miR)-155 in hydrogen peroxide (H 2O 2)-induced oxidative stress injury in lens epithelial cells (LECs) and its mechanism regulating silent information regulator factor related enzymes 1 (SIRT1). Methods:The HLE-B3 at the logarithmic growth phase was taken and cultured for 24 hours under different concentrations of H 2O 2 (0, 50, 100, 200, 400, 800 μmol/L), and the cell viability was detected by MTT assay to determine the optimal concentration of H 2O 2 for establishing an oxidative stress injury model.HLE-B3 cells were divided into 6 groups, untreated blank control group, model control group cultured with 100 μmol/L H 2O 2, miR-155 mimics group transfected with miR-155 mimics, miR-155 mimics negative control group transfected with miR-155 mimics negative control, miR-155 inhibitor group transfected with miR-155 inhibitor, and miR-155 inhibitor negative control group transfected with miR-155 inhibitor negative control.Transfected cells were cultured with 100 μmol/L H 2O 2.Cells in various groups were cultured for 24 hours, and cell morphology was observed under an inverted microscope.The relative expression of miR-155 and SIRT1 mRNA in cells was assayed by fluorescent quantitative PCR.Cell apoptosis rates were detected by flow cytometry.Reactive oxygen species (ROS) content was identified by 2', 7'-dichlorofluorescein diacetate (DCFH-DA) fluorescent probe method.Superoxide dismutase (SOD) activity and malondialdehyde (MDA) concentration were measured by ELISA method.The targeting of SIRT1 by miR-155 was tested by dual luciferase reporter gene system.Expressions of SIRT1, B-cell lymphoma/leukemia-2 gene (bcl-2), bcl-2 associated X protein (bax), cleaved-cysteine aspartase 3 (cleaved-Caspase-3) proteins were determined by Western blot. Results:With the increase of H 2O 2 concentration, the cell viability gradually decreased, and the differences in cell viability among different concentrations were statistically significant (all at P<0.05), and 100 μmol/L was selected as the experimental concentration.Cells in blank control group grew well adherently.The number of cells in model control group decreased, and the morphology of some surviving cells changed, and their boundaries were blurred.There were fewer cells in miR-155 mimics group than model control group, and the cell morphology changed.There were more cells in miR-155 inhibitor group than model control group, and the cells grew well.Compared with model control group, the relative expression level of miR-155, the apoptosis rate, ROS content, MDA concentration, as well as the relative expression levels of bax and cleaved-Caspase-3 proteins were increased, and the relative expression level of SIRT1 mRNA, the SOD activity, the relative expression of SIRT1 and bcl-2 proteins, as well as bcl-2/bax were decreased in miR-155 mimics group, and the differences were statistically significant (all at P<0.05). Compared with model control group, the relative expression of miR-155, the apoptosis rate, ROS content, MDA concentration, as well as the relative expression levels of bax and cleaved-Caspase-3 proteins were decreased, and the relative expression level of SIRT1 mRNA, SOD activity, the relative expression levels of SIRT1 and bcl-2 protein, as well as bcl-2/bax were significantly increased in miR-155 inhibitor group, and the differences were statistically significant (all at P<0.05). The relative luciferase activity of wild-type SIRT1 in cells transfected with miR-155 mimics was 0.41±0.07, which was significantly weaker than 1.00±0.11 in cells transfected with miR-155 mimics negative control, and the relative luciferase activity of wild-type SIRT1 in cells transfected with miR-155 inhibitor was 1.98±0.17, which was significantly higher than 1.00±0.12 in cells transfected with miR-155 inhibitor negative control, showing statistically significant differences ( t=7.838, 8.157; both at P<0.05). No obvious effect on the relative luciferase activity of mutant SIRT1 was found in transfected cells. Conclusions:miR-155 is involved in H 2O 2-induced oxidative damage of LECs, and its overexpression can target the expression of SIRT1 and play a role in cell injury.