1.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
2.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
3.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
4.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
5.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
6.Mechanism of Modified Erxian Decoction Regulating Perimenopausal Syndrome via SIRT1/Kisspeptin/GnRH Signaling Pathway
Ruiyu HUANG ; Fang LEI ; Wuchaonan LIU ; Jingjing YANG ; Qianru ZENG ; Shengping LUO ; Yanling CHEN ; Mengge ZHANG ; Fanshun SHEN ; Yihui DENG ; Dingxiang LI
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(22):51-62
ObjectiveTo explore the regulation of hypothalamic-pituitary-gonadal (HPG) axis by modified Erxian decoction in rats with perimenopausal syndrome (PMS) and to further analyze the expression of proteins related to the silent information regulator 1 (SIRT1)/hypothalamic kisspeptin (Kisspeptin)/gonadotropin-releasing hormone (GnRH) signaling pathway in the arcuate nucleus region (ARC) of the hypothalamus, so as to reveal the potential target of action and molecular biological mechanism of modified Erxian decoction for the treatment of perimenopausal syndrome. MethodsAn animal model was established via the incomplete castration method, with successful modeling confirmed by the exfoliated cervical cell smear method. The 48 rats were divided into six groups based on the randomization principle after successful modeling, including a sham operation group, a model group, an estradiol valerate group (0.09 mg∙kg-1∙d-1), high-, medium-, and low-dose modified Erxian decoction groups (7.614, 3.807,1.903 5 g∙kg-1∙d-1), with 8 rats in each group. The estradiol valerate group and the high-, medium- and low-dose modified Erxian decoction groups were continuously administered by gavage for 28 days, and the indicators were detected 24 hours after the last administration. Body weights and uterine indices were measured. The pathological changes of the uterus were observed by hematoxylin-eosin (HE) staining. Enzyme-linked immunosorbent assay (ELISA) was performed to measure the levels of estradiol (E2), follicle-stimulating hormone (FSH), luteinizing hormone (LH), and gonadotropin-releasing hormone (GnRH). Real-time quantitative polymerase chain reaction (Real-time PCR) and Western blot were used to determine the expression levels of SIRT1, Kisspeptin, kisspeptin receptor (GPR54), and GnRH in the ARC region of the hypothalamus and gonadotropin-releasing hormone receptor (GnRH-R) in pituitary. ResultsCompared with the sham operation group, rats in the model group had a significantly increased body weight (P0.01), reduced wet weight and index of uterus (P0.01), endometrial thinning or atrophy, glandular atrophy, and a decreasing number of glands. Additionally, serum levels of E2 and the expression of SIRT1 in the ARC region of the hypothalamus significantly decreased (P0.01). Serum levels of FSH, LH, and GnRH, the expression of Kisspeptin, GPR54, and GnRH in the ARC region of the hypothalamus, and GnRH-R in pituitary significantly increased (P0.01). Compared with the model group, the estradiol valerate group and the high-, medium-dose modified Erxian decoction groups had significantly reduced body weight, serum levels of FSH, LH, and GnRH, and expression of Kisspeptin, GPR54, and GnRH in the ARC region of the hypothalamus and GnRH-R in pituitary (P0.05, P0.01) and significantly increased wet weight and index of uterus, serum level of E2, and expression of SIRT1 in the ARC region of the hypothalamus (P0.05, P0.01). In addition, they showed thickened endometrium, increased number of endometrial glands, and improved glandular atrophy. ConclusionModified Erxian decoction regulates the function of the HPG axis through multi-targets, and its mechanism of action may be related to the up-regulation of the expression of SIRT1 in the ARC region of the hypothalamus, the inhibition of the over-activation of the Kisspeptin/GnRH signaling pathway, the regulation of the expression of GnRH-R in the pituitary, the restoration of secretion balance of gonadotropins, and the elevation of the estrogen level. This study provides an experimental basis for the interpretation of the scientific connotation of modified Erxian decoction in the treatment of perimenopausal syndrome and a theoretical reference for the development of a novel therapeutic strategy based on the SIRT1/Kisspeptin/GnRH pathway.
7.Establishment of animal model of cervicofacial venous malformations with external jugular vein in sheep
Xia YANG ; Yanling SHEN ; Jun GUO ; Yuan LIU ; Zhiwei YAN ; Xiangming YANG ; Wei WU ; Yao FENG ; Yaowu YANG
Journal of Practical Stomatology 2024;40(1):43-46
Objective:To establish the animal model of cervicofacial venous malformations(VMs)by surgical reconstruction of exter-nal jugular vein in sheep.Methods:The external jugular veins of 5 sheep were dissected,and the position,course,branch and exter-nal diameter were observed and measured.The models of VMs with draining and returning veins were constructed by suturing or constric-ting the proximal part of main trunk and ligating or constricting the distal part of the jugular or branch veins.The animal model was eval-uated by Doppler ultrasound,gross observation and histological observation at the 4th week after surgery.Results:The external jugular veins of sheep is in the lateral side of bilateral neck,and the main trunk is formed by the maxillary vein and lingual facial vein.The ex-ternal diameter ranges from 6 to 12 mm,with an average external diameter of 9.3 mm.Immediately after the external jugular vein was sutured and narrowed at the proximal part of the main vein,the distal part of the vein branch was ligated or narrowed,the blood flow speed slowed down and the veins in the model area bulged.4 weeks after surgery,gross observation showed that most veins narrowed and thrombosis was formed in part of the venous lumen.The central region of some specimens was dilated,and the peripheral collateral veins were dilated in some models.Doppler ultrasonography showed that the lumens of most veins were dilated and the returning veins and the inflow veins were narrowed.Colored blood flow was seen in the lumen.Histological observation showed that the structure of vein endothelium and wall was close to the normal vein,and the vein vessel wall of some specimens was thickened.Conclusion:The VMs model estab-lished by external jugular vein of sheep basically meets the re-quirements and is expected to be used in the therapeutic meth-odology research of cervicofacial VMs.
8.Construction Practice of Remote Maternal Fetal Monitoring System Based on 5G Technology
Tian GUO ; Yanling SHEN ; Mengxiang LI ; Weiwei CHENG ; Lei CHEN
Journal of Medical Informatics 2024;45(2):82-86
Purpose/Significance To explore the establishment of a remote maternal and fetal monitoring system based on 5 G tech-nology in the obstetrics and gynecology hospital,and to provide references for the medical system to improve telemedicine and smart medi-cal care based on 5 G technology.Method/Process By utilizing the advantages of 5 G technology such as fast speed,wide spectrum and low delay,and combining services such as maternal and fetal monitoring,online education,remote consultation,artificial intelligence(AI),health data management,and medical green channel,the maternal and fetal monitoring database and the AI model of maternal and fetal monitoring are constructed,the remote maternal and fetal monitoring system is constructed,and fetal heart monitoring process is op-timized.Result/Conclusion It realizes the combination of maternal and fetal monitoring application in hospital and outside hospital,medical alliance applications,internet hospital applications and ambulance transfer process applications.
9.Screening and characterization of anti-SARS-CoV-2 receptor binding domain antibodies with broad-spectrum neutralizing activity
NI Wanqi ; REN Li ; JIN Changzhong ; YANG Furong ; SHEN Yumin ; WANG Shuo ; HU Caiqin ; HAO Yanling ; LIU Ying ; ZHU Biao ; SHAO Yiming ; LI Dan ; WANG Zheng
China Tropical Medicine 2024;24(3):258-
convalescents, and to screen for broad-spectrum neutralizing antibodies against the SARS-CoV-2 RBD. Methods Using biotinylated RBD as a molecular probe, flow cytometry was employed to perform single-cell sorting of B cells from peripheral blood mononuclear cells (PBMCs) of convalescents. The obtained B cells were lysed and subjected to reverse transcription, followed by nested PCR amplification of the heavy and light chains of antibodies was conducted using random primers. The amplified products were cloned into corresponding expression vectors, and the respective matched heavy-light chain plasmids were co-transfected into 293F cells for expression. Monoclonal antibodies were then purified using Protein A column chromatography. Neutralization experiments were conducted with the wild-type (WT) pseudovirus, and antibodies with IC50<0.1 μg/mL were selected for further testing of neutralizing breadth and potency against the wild-type (WT), Beta variant (B.1.351), Delta variant (B.1.617.2), and currently prevalent pseudovirus strains (XBB, BA.5, BF.7). Results A total of 21 RBD-specific monoclonal B cells were obtained from two recovered patients, resulting in the isolation of 13 pairs of antibody light/heavy chains. Nine antibodies were successfully expressed, with P1-A1, P1-B6, and P1-B9 exhibiting IC50 values below 0.1 μg/mL against the pseudovirus of the wild-type strain (WT). Specifically, P1-B6 effectively neutralized the wild-type strain (WT), Beta variant (B.1.351), and Delta variant (B.1.617.2), with IC50 values reaching 0.01 μg/mL. P1-B9 demonstrated effective neutralization against the wild-type strain (WT), Beta variant (B.1.351), Delta variant (B.1.617.2), and Gamma variant (P.1) pseudoviruses, with IC50 values of 0.42 μg/mL, 0.63 μg/mL, 0.28 μg/mL, and 2.50 μg/mL, respectively. Additionally, P1-B6 exhibited good neutralization against BA.5 and BF.7 pseudoviruses, with IC50 values of 0.06 μg/mL and 0.09 μg/mL, respectively. Conclusions Infection with the SARS-CoV-2 WT strain can induce the generation of neutralizing antibodies with broad-spectrum activity. Generating these broadly neutralizing antibodies does not require an excessively high somatic hypermutation. The obtained antibodies can be used as candidates for SARS-CoV-2 diagnosis and prevention.
10.Effects of oropharyngeal aspiration for the prevention of ventilator-associated pneumonia: a Meta-analysis
Jingjing BU ; Jie ZHANG ; Yanshuo WU ; Peng GAO ; Kangkang SHEN ; Yanling YIN
Chinese Journal of Practical Nursing 2024;40(34):2688-2695
Objective:To evaluate the effect of oropharyngeal aspiration on reducing ventilator-associated pneumonia,in order to provide a basis for clinical operation and practice.Methods:CNKI, Wanfang, China Biology Medicine Disc, VIP, PubMed, Embase, Cochrane Library, Web of Science and CINAHL databases were searched for relevant studies on the effects of oropharyngeal attraction on ventilators associated pneumonia. At the same time, the included references were screened, and the search time limit was from the establishment of the database to January 1, 2023. The quality of the included literature was strictly evaluated and data extracted by two researchers with evidence-based training, and Meta-analysis was performed by RevMan 5.4 software.Results:The results of meta-analysis showed that oropharyngeal aspiration could reduce the incidence of ventilator-associated pneumonia ( OR=0.30, 95% CI 0.22-0.40, P<0.01) and shorten the duration of mechanical ventilation ( MD=-2.39, 95% CI -3.59--1.20, P<0.01) and reduced length of stay in ICU ( MD=-2.62, 95% CI -2.99--2.26, P<0.01). Conclusions:Strengthening oropharyngeal aspiration can reduce the incidence of ventilator-associated pneumonia in patients with mechanical ventilation. In clinical practice, oropharyngeal aspiration should be performed when the position changes, and continuous aspiration can be performed if conditions are met.

Result Analysis
Print
Save
E-mail