1.Analysis on Quality Standard of Hedyotis Herba Dispensing Granules Based on Standard Decoction
Jinghua ZHANG ; Nana WU ; Yanan LYU ; Guiyun CAO ; Jiacheng XU ; Yongqiang LIN ; Xiaodi DONG ; Jinxin LI ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(10):210-217
ObjectiveTo establish the specific chromatogram and quantitative analysis of multi-components by single-marker(QAMS) based on linear calibration using two reference substances(LCTRS), explore the consistency between Hedyotis Herba dispensing granules and standard decoction, and evaluate the quality of the dispensing granules. MethodsHigh performance liquid chromatography(HPLC) specific chromatogram was established based on 15 batches of Hedyotis Herba standard decoction and 10 batches of the dispensing granules, and LCTRS was used to locate chromatographic peaks. The actual retention times of 7 characteristic peaks in the specific chromatogram was measured on 24 different types of C18 columns, taking deacetyl asperulosidic acid and asperulosidic acid as the dual standard compounds, the retention times of the other 5 characteristic peaks were predicted and validated. Based on this, QAMS was developed to determine the contents of four components(deacetyl asperulosidic acid, deacetyl asperulosidic acid methyl ester, asperulosidic acid, and p-coumaric acid). Then, the relative correction factors of deacetyl asperulosidic acid, deacetyl asperulosidic acid methyl ester and p-coumaric acid were calculated using the reference peak of asperulosidic acid in the dual standard compounds, and each component was quantified accordingly. Finally, the consistency between the dispensing granules and standard decoction was assessed by taking extract rate of the standard decoction, consistency of the specific chromatograms, contents and transfer rates of the indicator components as indexes, and the quality of the dispensing granules was evaluated. ResultsThere were 7 common peaks in the characteristic chromatogram of samples of Hedyotis Herba standard decoction and the dispensing granules, and four of them were identified by reference standards, namely deacetyl asperulosidic acid(peak 1), deacetyl asperulosidic acid methyl ester(peak 3), asperulosidic acid(peak 6) and p-coumaric acid(peak 7). The similarity between the dispensing granules and the standard decoction was >0.9. The absolute deviation in the predicted retention time for each component by LCTRS was lower than that of the relative retention time method. The extract rate of the 15 batches of Hedyotis Herba standard decoction ranged from 7.89% to 14.60%, the contents of deacetyl asperulosidic acid, deacetyl asperulosidic acid methyl ester, asperulosidic acid and p-coumaric acid were 6.62-19.70, 3.83-17.99, 1.57-6.69, 1.62-4.52 mg·g-1, and the transfer rates of these components from decoction pieces to the standard decoction were 22.89%-39.60%, 34.03%-62.24%, 24.25%-43.70%, and 40.58%-73.71%, respectively. The extract rate, index component contents and transfer rates from decoction pieces to the three batches of Hedyotis Herba dispensing granules(P1-P3), produced by manufacturer A, were similar to those of the standard decoction prepared from the same batch of decoction pieces, and all fell within the specified range. The contents of the 4 indicator components in 7 batches of the dispensing granules(P4-P10) from manufacturers B-E were all within the range of the content converted from the standard decoction based on the quantity of the dispensing granules. ConclusionThe established specific chromatogram and QAMS based on LCTRS are reasonable and reliable. Based on the evaluation indicators of standard decoction yield, consistency of specific chromatograms, contents and transfer rates of the four index components, the 10 batches of Hedyotis Herba dispensing granules from various manufacturers have exhibited good consistency with the standard decoction, indicating that the current production process is relatively reasonable.
2.Evaluation of dietary intervention in patients with hypertensive nephropathy
WANG Qikai ; MI Yanan ; LIU Hao ; LIN Jiahao ; YANG Xinyuan ; WANG Yue ; JIN Qianjing ; SONG Zhaomeng
Journal of Preventive Medicine 2025;37(4):373-377
Objective:
To evaluate the effects of dietary intervention on blood pressure and renal function in patients with hypertensive nephropathy, so as to provide dietary and nutritional guidances for this population.
Methods:
Hypertensive nephropathy patients who were treated at Zhucheng People's Hospital from March 2023 to February 2024 were selected as the study subjects and randomly divided into the intervention group and the control group. The control group received routine antihypertensive treatment and health lifestyle guidance. On the basis of the treatment and guidance received by the control group, the intervention group implemented dietary intervention in accordance with the Clinical Practice Guidelines for Nutritional Therapy of Chronic Kidney Disease in China (2021 edition) for a period of 3 months. Systolic blood pressure (SBP), diastolic blood pressure (DBP) were measured before and after the intervention, and serum creatinine (Scr), blood urea nitrogen (BUN), uric acid (UA), cystatin and β2-microglobulin were detected. Differences of indicators before and after intervention between the two groups were compared using generalized estimation equation.
Results:
A total of 83 patients with hypertensive nephropathy were followed up, including 43 cases in the intervention group and 40 cases in the control group. There were no statistically significant differences in gender, age, body mass index, duration of hypertension, family history of hypertension, hypertension grade, physical activity index, or smoking status between the two groups (all P>0.05). The differences in SBP, DBP, Scr, BUN, and UA between the two groups, as well as the differences before and after the intervention, were statistically significant, and there was an interaction between the groups and the intervention time (all P<0.05). After intervention, the levels of SBP, DBP, Scr, BUN, and UA in the intervention group were lower than those in the control group (all P<0.05). The differences in cystatin and β2-microglobulin between the two groups and before and after the intervention were not statistically significant, and there was no interaction between the groups and the intervention time (all P>0.05).
Conclusion
Dietary intervention has a certain effect on reducing blood pressure and improving renal function indicators in patients with hypertensive nephropathy.
3.The interval of rescue treatment does not affect the efficacy and safety of Helicobacter pylori eradication: A prospective multicenter observational study.
Minjuan LIN ; Junnan HU ; Jing LIU ; Juan WANG ; Zhongxue HAN ; Xiaohong WANG ; Zhenzhen ZHAI ; Yanan YU ; Wenjie YUAN ; Wen ZHANG ; Zhi WANG ; Qingzhou KONG ; Boshen LIN ; Yuming DING ; Meng WAN ; Wenlin ZHANG ; Miao DUAN ; Shuyan ZENG ; Yueyue LI ; Xiuli ZUO ; Yanqing LI
Chinese Medical Journal 2025;138(12):1439-1446
BACKGROUND:
The effect of the interval between previous Helicobacter pylori (H. pylori) eradication and rescue treatment on therapeutic outcomes remains unknown. The aim of this study was to investigate the association between eradication rates and treatment interval durations in H. pylori infections.
METHODS:
This prospective observational study was conducted from December 2021 to February 2023 at six tertiary hospitals in Shandong, China. We recruited patients who were positive for H. pylori infection and required rescue treatment. Demographic information, previous times of eradication therapy, last eradication therapy date, and history of antibiotic use data were collected. The patients were divided into four groups based on the rescue treatment interval length: Group A, ≥4 weeks and ≤3 months; Group B, >3 and ≤6 months; Group C, >6 and ≤12 months; and Group D, >12 months. The primary outcome was the eradication rate of H. pylori . Drug compliance and adverse events (AEs) were also assessed. Pearson's χ2 test or Fisher's exact test was used to compare eradication rates between groups.
RESULTS:
A total of 670 patients were enrolled in this study. The intention-to-treat (ITT) eradication rates were 88.3% (158/179) in Group A, 89.6% (120/134) in Group B, 89.1% (123/138) in Group C, and 87.7% (192/219) in Group D. The per-protocol (PP) eradication rates were 92.9% (156/168) in Group A, 94.5% (120/127) in Group B, 94.5% (121/128) in Group C, and 93.6% (190/203) in Group D. There was no statistically significant difference in the eradication rates between groups in either the ITT ( P = 0.949) or PP analysis ( P = 0.921). No significant differences were observed in the incidence of AEs ( P = 0.934) or drug compliance ( P = 0.849) between groups.
CONCLUSION:
The interval duration of rescue treatment had no significant effect on H. pylori eradication rates or the incidence of AEs.
REGISTRATION
ClinicalTrials.gov , NCT05173493.
Humans
;
Helicobacter Infections/drug therapy*
;
Helicobacter pylori/pathogenicity*
;
Male
;
Female
;
Prospective Studies
;
Middle Aged
;
Anti-Bacterial Agents/adverse effects*
;
Adult
;
Aged
;
Treatment Outcome
;
Proton Pump Inhibitors/therapeutic use*
4.Design and Implementation of Non-Invasive Hemodynamic Monitoring System Based on Impedance Cardiogram Method.
Fuhao KANG ; Qi YIN ; Yanan LIU ; Lin HUANG ; Yan HANG ; Jilun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2025;49(1):80-88
Hemodynamic monitoring can reflect cardiac function and blood perfusion and is an indispensable monitoring method in clinical practice. Invasive hemodynamic monitoring methods represented by the thermodilution method are limited in their clinical application scope because they require vascular cannulation. Non-invasive hemodynamic monitoring has attracted extensive attention from medical companies and clinicians at home and abroad in recent years due to its advantages such as safety, non-invasiveness, continuous monitoring, simple operation, and low cost. This paper designs a non-invasive hemodynamic monitoring system based on the impedance cardiography, including hardware, algorithm, software design, and performance parameter evaluation. Among them, the hardware part mainly includes a differential high-frequency constant current source stimulation circuit, impedance cardiogram signal acquisition, and ECG signal acquisition circuit. Signal processing includes wave filtering, impedance cardiogram signal calibration, and ECG signal and impedance cardiogram signal feature point recognition. According to the collected impedance cardiogram and ECG signals, hemodynamic parameters such as heart rate (HR), stroke volume (SV), cardiac output (CO), stroke index (SI), cardiac index (CI), and cardiac contractility index (ICON) are calculated based on the Nyboer thoracic cylinder model. After testing, the key technical indicators of the system hardware are better than that of the relevant medical device standards. The system was used to collect impedance cardiogram and ECG signal data from 40 volunteers. The calculated HR, SV, and CO, three important hemodynamic indicators, were compared with the ICONCore non-invasive cardiac output monitor of OSYPKA Medical in Germany. Their Pearson correlation coefficients were 0.992 ( P<0.001), 0.948 ( P<0.001), and 0.933 ( P<0.001), respectively, verifying that the designed system has high accuracy and reliability.
Cardiography, Impedance/methods*
;
Humans
;
Hemodynamic Monitoring/methods*
;
Equipment Design
;
Signal Processing, Computer-Assisted
;
Hemodynamics
;
Algorithms
;
Monitoring, Physiologic/methods*
;
Electrocardiography
5.Development of a Multimodal Transcranial Electrical Stimulation System with Integrated Four-Channel EEG Recordings.
Yan HANG ; Chaoyang WANG ; Qi YIN ; Yanan LIU ; Lin HUANG ; Jilun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2025;49(3):313-322
In order to improve the effect of transcranial electrical stimulation treatment and realize personalized treatment for patients with varying severity levels, this paper designed an integrated four-channel EEG recording multimodal transcranial electrical stimulation system. This system can conduct real-time monitoring on EEG and related characteristic analysis before stimulation, in stimulation, and after stimulation. This enables physicians and researchers to resolve real-time brain states, evaluate transcranial electrical stimulation effect, and then artificially adjust the stimulation parameters. After relevant testing and verification, the system can select four stimulation modes: TACS, TDCS, TPCS and TRNS, which can output the constant stimulation current of 0.03 mA accuracy in the range of ±2 mA and the stimulation frequency of low frequency of 0~4 kHz (precision of 0.01 Hz) and high frequency 50~100 kHz, which can obtain more accurate EEG signals under stimulation interference, demonstrating a good market application prospect.
Electroencephalography/methods*
;
Transcranial Direct Current Stimulation/instrumentation*
;
Humans
;
Equipment Design
6.Sixteen-Channel Multimodal High-Precision Transcranial Electrical Stimulation System Development.
Yan HANG ; Qi YIN ; Lin HUANG ; Fuhao KANG ; Yanan LIU ; Jilun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2025;49(4):435-443
This paper introduces a 16-channel multimodal high-precision transcranial electrical stimulation system specifically for non-invasive brain stimulation. This system added TMCS mixed four traditional stimulation modes with TACS, TDCS, TPCS and TRNS. By designing a compensated high-precision constant current source, the constant stimulation current with an accuracy of 0.03 mA in the range of ±2 mA and the stimulation frequency of 50~200 kHz with low frequency of 0~4 kHz (high frequency of 0.1 Hz) are realized. In TACS stimulation mode, there are five adjustable wave forms: triangular wave, sine wave, sawtooth wave, square wave and mixed wave. The system has dual closed-loop control overcurrent detection and simultaneous real-time electrode contact impedance detection. After relevant tests and verification, the system has good stimulation accuracy, high safety and reliability. Compared with the existing products at home and abroad, it features lower cost, richer stimulation mode and waveforms, demonstrating a certain market application value.
Transcranial Direct Current Stimulation/instrumentation*
;
Equipment Design
;
Humans
7.Relationship between physical activity and postoperative delirium in elderly patients undergoing knee or hip arthroplasty
Jian KONG ; Yunfei QIU ; Shanling XU ; Yuanlong WANG ; Shuhui HUA ; Yanan LIN ; Chuan LI ; Rui DONG ; Hongyan GONG ; Xu LIN ; Bin WANG ; Yanlin BI
Chinese Journal of Anesthesiology 2024;44(8):922-926
Objective:To evaluate the relationship between physical activity (PA) and postoperative delirium (POD) in elderly patients undergoing knee or hip arthroplasty.Methods:The study was conducted as part of the Perioperative Neurocognitive Impairment and Biomarkers Lifestyle Cohort, which was a nested case-control study. Medical records from elderly patients undergoing elective knee or hip arthroplasty under spinal-epidural anesthesia at Qingdao Municipal Hospital from August 2022 to August 2023 were collected. The patients were divided into a POD group ( n=89) and a non-POD group ( n=221) based on the occurrence of POD. Peripheral blood samples were collected before surgery, and the cerebrospinal fluid (CSF) 2 ml was extracted after successful puncture under spinal-epidural anesthesia for determination of the concentrations of amyloid-β 42 (Aβ 42), total tau protein (t-tau), and phosphorylated tau protein (p-tau) by enzyme-linked immunosorbent assay. Logistic regression was used to analyze the influencing factors of POD, and the mediation analysis was conducted to examine the mediating role of CSF biomarker in the relationship between PA and POD. Results:Logistic regression analysis showed that the increased concentration of CSF biomarkers Aβ 42 ( OR=0.997, P=0.006), elevated ratio of Aβ 42/t-tau ( OR=0.642, P=0.003), elevated ratio of Aβ 42/p-tau ratio ( OR=0.872, P=0.001) and PA ( OR=0.374, P=0.001) were protective factors for POD, while the elevated concentrations of t-tau ( OR=1.006, P=0.001) and p-tau ( OR=1.030, P=0.011) were risk factors for POD after adjusting for multi-confounders such as hypertension, diabetes, history of drinking, years of education and Mini-Mental State Examination score. The results of the mediation analysis showed that Aβ 42 (20%), t-tau (16%), Aβ 42/t-tau (23%) and Aβ 42/p-tau (28%) played mediating roles in the relationship between PA and POD. Conclusions:PA is a protective factor for POD in elderly patients undergoing knee or hip arthroplasty and CSF biomarkers may play a mediating role in the relationship between PA and POD.
8.Relationship between preoperative sleep quality and postoperative delirium in elderly patients
Yuanlong WANG ; Yanling LI ; Shuhui HUA ; Shanling XU ; Jian KONG ; Hongyan GONG ; Rui DONG ; Yanan LIN ; Chuan LI ; Yanlin BI ; Bin WANG ; Xu LIN
Chinese Journal of Anesthesiology 2024;44(11):1287-1292
Objective:To evaluate the relationship between the preoperative sleep quality and postoperative delirium (POD) in elderly patients.Methods:Three hundred and eighty-nine patients of either sex, aged 65-90 yr, with American Society of Anesthesiologists Physical Status classification Ⅰ or Ⅱ, who underwent elective knee/hip arthroplasty under combined spinal-epidural anesthesia in Qingdao Municipal Hospital from May 2022 to October 2023, were selected. The Pittsburgh Sleep Quality Index scale was applied at 1 day before surgery to assess the sleep quality within 1 month before surgery. The cerebrospinal fluid (CSF) specimens 2 ml were withdrawn from the subarachnoid space before anesthesia for determination of the concentrations of biomarkers (β-amyloid), total tau protein [t-tau], and phosphorylated tau protein [p-tau]) by enzyme-linked immunosorbent assay. Patients were divided into POD group and non-POD group based on whether delirium occurred within 7 days after surgery. Logistic regression was used to identify the risk factors for POD, and the sensitivity analysis was used to test the stability of the regression models. The mediation model was used to examine whether CSF biomarkers mediated the link between sleep quality and POD. The accuracy of preoperative sleep quality and CSF biomarker concentrations in predicting the occurrence of POD was evaluated by plotting the receiver operating characteristic curve and calculating the area under the curve.Results:Two hundred and seventy-nine patients were finally included, with 33 patients in POD group and 246 patients in non-POD group. The results of logistic regression analysis showed that shorter sleep duration, use of hypnotics, daytime dysfunction within 1 month before surgery, elevated t-tau concentrations in CSF, and elevated p-tau concentrations in CSF were risk factors for POD after adjusting for multiple confounding factors such as age, sex, body mass index, years of education, Mini-Mental State Examination score, and VAS score. The results of mediating effect showed that the effect of use of hypnotics and daytime dysfunction within 1 month before surgery on POD was partially mediated by p-tau concentrations in CSF (>10%). The area under the curve of combination of daytime dysfunction, sleep duration, use of hypnotics within 1 month before surgery, and CSF biomarker concentrations in predicting POD was 0.979.Conclusions:Shortened sleep duration, use of hypnotic, and daytime dysfunction with 1 month before surgery are risk factors for POD in elderly patients, and the association between use of hypnotics and daytime dysfunction and POD is partially mediated by p-tau in CSF.
9.Construction of a machine learning model for identifying clinical high-risk carotid plaques based on radiomics
Xiaohui WANG ; Xiaoshuo LÜ ; ; Zhan LIU ; Yanan ZHEN ; Fan LIN ; Xia ZHENG ; Xiaopeng LIU ; Guang SUN ; Jianyan WEN ; Zhidong YE ; Peng LIU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(01):24-34
Objective To construct a radiomics model for identifying clinical high-risk carotid plaques. Methods A retrospective analysis was conducted on patients with carotid artery stenosis in China-Japan Friendship Hospital from December 2016 to June 2022. The patients were classified as a clinical high-risk carotid plaque group and a clinical low-risk carotid plaque group according to the occurrence of stroke, transient ischemic attack and other cerebrovascular clinical symptoms within six months. Six machine learning models including eXtreme Gradient Boosting, support vector machine, Gaussian Naive Bayesian, logical regression, K-nearest neighbors and artificial neural network were established. We also constructed a joint predictive model combined with logistic regression analysis of clinical risk factors. Results Finally 652 patients were collected, including 427 males and 225 females, with an average age of 68.2 years. The results showed that the prediction ability of eXtreme Gradient Boosting was the best among the six machine learning models, and the area under the curve (AUC) in validation dataset was 0.751. At the same time, the AUC of eXtreme Gradient Boosting joint prediction model established by clinical data and carotid artery imaging data validation dataset was 0.823. Conclusion Radiomics features combined with clinical feature model can effectively identify clinical high-risk carotid plaques.
10.Association between preoperative serum β 2-microglobulin concentrations and postoperative delirium in elderly patients
Yuanlong WANG ; Qian HE ; Shuhui HUA ; Shanling XU ; Jian KONG ; Hongyan GONG ; Rui DONG ; Yanan LIN ; Chuan LI ; Yanlin BI ; Bin WANG ; Xu LIN
Chinese Journal of Anesthesiology 2024;44(2):145-149
Objective:To evaluate the association between preoperative serum β 2-microglobulin (β 2MG) concentrations and postoperative delirium (POD) in elderly patients. Methods:The study selected patients who underwent knee or hip arthroplasty under spinal-epidural anesthesia on an elective basis at Qingdao Municipal Hospital from May 2021 to November 2022. The patients were divided into a POD group and a non-POD group based on the occurrence of POD. The study was conducted as part of the Perioperative Neurocognitive Impairment and Biomarkers Lifestyle Cohort, which was a nested case-control study. The study collected baseline data from two groups of patients and analyzed the differences between them. Logistic regression was used to identify the risk factors for POD. The stability of the regression model was tested using sensitivity analysis. The mediation model was used to examine whether cerebrospinal fluid (CSF) biomarkers mediated the relationship between β 2MG and POD. The receiver operating characteristic curve was drawn and the area under the curve was calculated to evaluate the accuracy of preoperative β 2MG concentrations and CSF biomarker concentration in predicting POD. Results:There were 57 cases in POD group and 449 cases in non-POD group. The results of logistic regression analysis showed that the increased β 2MG and CSF total tau protein (t-tau) concentrations were risk factors for POD, and the increased CSF β-amyloid 42 concentration was a protective factor for POD after adjustment for multiple confounders such as age, gender, education, Mini-Mental State Examination, history of hypertension and infusion volume ( P<0.05). The results of mediation analysis showed that the serum β 2MG′s effect on POD was partly mediated by t-tau (18.1%). The results of the receiver operating characteristic curve showed that the area under the curve of the β 2MG concentration combined with the CSF biomarker concentration was 0.742. Conclusions:Elevated preoperative serum β 2MG concentration is a risk factor for POD in elderly patients, and the relationship may be partly mediated by CSF t-tau.


Result Analysis
Print
Save
E-mail