1.Repeatability of wavefront aberration measured by adaptive optics visual simulator and agreement of OPD-Scan Ⅲ
Yan WANG ; Xuan LIAO ; Changjun LAN ; Biao LI ; Zhuang MIAO ; Qingqing TAN ; Suyun QIN ; Huan HUANG
International Eye Science 2024;24(5):810-815
AIM: To assess the repeatability and agreement of higher-order aberration obtained by adaptive optics visual simulator(VAO)compared with OPD-Scan Ⅲ.METHODS: A cross-sectional study was conducted from August to September 2023, including a total of 204 patients(204 eyes)with myopia whose right eyes were measured. The examinations were performed by the same skilled examiner using both devices separately. The VAO device was used to measure higher order aberrations of orders 3 to 6 at a pupil diameter of 4.5 mm, while both the VAO and OPD-Scan Ⅲ devices were utilized to measure total higher-order aberration(tHOA), spherical aberration(SA), coma aberration(Coma), and trefoil aberration(Trefoil)of the entire eye at pupil diameters ranging from 3 to 6 mm. Furthermore, the repeatability of whole eye aberration measurements obtained with the VAO device was evaluated and the agreement of the two devices was assessed.RESULTS: The whole-eye higher-order aberrations measured by VAO demonstrated excellent repeatability(0.767≤ICC≤0.941, Sw<0.01 μm, TRT<0.1 μm). There was no statistically significant difference in Coma measured by VAO or OPD-Scan Ⅲ for pupil diameters ranging from 4 to 6 mm(P>0.05), while a statistically significant difference was observed in whole-eye tHOA of other pupil diameters(all P<0.05). The agreement of aberration measurements for each order between VAO and OPD-Scan Ⅲ for 3 mm pupil diameters, SA at 4 and 5 mm pupil diameter and Coma at 4 mm pupil diameter showed a 95% limit of agreement(LoA)<0.1, indicating good agreement; however, poor agreement was found for the remaining aberration measurements at different pupil diameters, with a 95%LoA>0.1, and there were significant differences in higher-order aberrations measured by two devices under a pupil diameter of 3 mm(r=0.218-0.317, P<0.01), 4 mm(r=0.406-0.672, P<0.01), 5 mm(r=0.538-0.839, P<0.01 and r=0.030-0.109, P>0.01)and 6 mm(r=0.369-0.766, P<0.01).CONCLUSION: The VAO demonstrates favorable repeatability when assessing whole-eye higher order aberration under pupil diameters of 3-6 mm. However, there is inadequate agreement and interchangeability in whole-eye higher order aberration at 3-6 mm pupil diameter between VAO and OPD-Scan Ⅲ for clinical purposes.
2.Evaluation of the safety and efficacy of mitomycin C-perfluorooctyl bromide liposome nanoparticles in the treatment of human pterygium fibroblasts
Tao LI ; Lingshan LIAO ; Shenglan ZHU ; Juan TANG ; Xiaoli WU ; Qilin FANG ; Ying LI ; Biao LI ; Qin TIAN ; Junmei WAN ; Yi YANG ; Yueyue TAN ; Jiaqian LI ; Juan DU ; Yan ZHOU ; Dan ZHANG ; Xingde LIU
Recent Advances in Ophthalmology 2024;44(2):100-105
Objective To prepare a nano drug(PFOB@Lip-MMC)with liposome as the carrier,liquid perfluorooc-tyl bromide(PFOB)as core and mitomycin C(MMC)loading on the liposome shell and study its inhibitory effect on the proliferation of human pterygium fibroblasts(HPFs).Methods The thin film dispersion-hydration ultrasonic method was used to prepare PFOB@Lip-MMC and detect its physical and chemical properties.Cell Counting Kit-8,Cam-PI cell viability staining and flow cytometry were employed to detect the impact of different concentrations of PFOB@Lip-MMC on the via-bility of HPFs.DiI fluorescence labeled PFOB@Lip-MMC was used to observe the permeability of the nano drug to HPFs under a laser confocal microscope.After establishing HPF inflammatory cell models,they were divided into the control group(with sterile phosphate-buffered saline solution added),PFOB@Lip group(with PFOB@Lip added),MMC group(with MMC added),PFOB@Lip-MMC group(with PFOB@Lip-MMC added)and normal group(with fresh culture medi-um added)according to the experimental requirements.After co-incubation for 24 h,flow cytometer was used to detect the apoptosis rate of inflammatory cells,and the gene expression levels of interleukin(IL)-1β,prostaglandin E2(PGE2),tumor necrosis factor(TNF)-α and vascular endothelial growth factor(VEGF)in cells were analyzed by PCR.Results The average particle size and Zeta potential of PFOB@Lip-MMC were(103.45±2.17)nm and(27.34±1.03)mV,respec-tively,and its entrapped efficiency and drug loading rate were(72.85±3.28)%and(34.27±2.04)%,respectively.The sustained-release MMC of drug-loaded nanospheres reached(78.34±2.92)%in vitro in a 24-hour ocular surface environ-ment.The biological safety of PFOB@Lip-MMC significantly improved compared to MMC.In terms of the DiI fluorescence labeled PFOB@Lip-MMC,after co-incubation with inflammatory HPFs for 2 h,DiI fluorescence labeling was diffusely dis-tributed in the cytoplasm of inflammatory HPFs.The apoptosis rate of inflammatory HPFs in the PFOB@Lip-MMC group[(77.23±4.93)%]was significantly higher than that in the MMC group[(51.62±3.28)%].The PCR examination results showed that the gene transcription levels of IL-1 β,PGE2,TNF-α and VEGF in other groups were significantly reduced com-pared to the control group and PFOB@Lip group,with the most significant decrease in the PFOB@Lip-MMC group(all P<0.05).Conclusion In this study,a novel nano drug(PFOB@LIP-MMC)that inhibited the proliferation of HPFs was successfully synthesized,and its cytotoxicity was significantly reduced compared to the original drugs.It has good bio-compatibility and anti-inflammatory effects,providing a new treatment approach for reducing the recurrence rate after pte-rygium surgery.
3.Evaluation of optical performance of aspherical intraocular lens in vitro by optical bench
Lixuan XIE ; Xuan LIAO ; Changjun LAN ; Qingqing TAN ; Ruolin PAN ; Yuling TANG ; Suyun QIN ; Yan WANG
Chinese Journal of Experimental Ophthalmology 2024;42(3):240-247
Objective:To evaluate the optical performance of two aspheric intraocular lenses (IOL) AcrySof IQ SN60WF and Proming A1-UV with identical negative spherical aberration values, using the optical bench OptiSpheric IOL R&D through an in vitro study. Methods:The optical performance of + 20.0 D blue-light filtering SN60WF and monofocal high-order aspheric non blue-light filtering A1-UV IOL was evaluated through cornea models with the spherical aberration of 0 μm (ISO-1) and + 0.28 μm (ISO-2) under apertures of 3.0 mm and 4.5 mm via the optical bench OptiSpheric IOL R&D.The modulation transfer function (MTF) and USAF 1951 resolution test chart were employed to measure the IOL with centering, decentration of 0.3, 0.5, 0.7, 0.9 and 1.1 mm, as well as tilt of 3°, 5°, 7°, 9° and 11°.The spectral transmittance of IOL was measured with the UV-3300 UV-VIS spectrophotometer.Results:Compared with the A1-UV IOL, the spectral transmittance of SN60WF for blue light with wavelengths of 400-500 nm was significantly reduced, which effectively reduced the passage of blue light.At an aperture of 3.0 mm, the MTF values at 100 lp/mm spatial frequency for the centered SN60WF and A1-UV were 0.576 and 0.598 under ISO-1 corneal measurement conditions, 0.564 and 0.563 under ISO-2 conditions.At an aperture of 4.5 mm, the MTF values were 0.238 and 0.404 under ISO-1 corneal measurement conditions, and 0.438 and 0.339 under ISO-2 conditions.The MTF values of A1-UV and SN60WF at 3.0 mm aperture and 100 lp/mm spatial frequency under ISO-1 corneal measurement conditions were larger than those under ISO-2 corneal measurement conditions.Under ISO-1 corneal measurement conditions with a 3.0 mm aperture, A1-UV had a better optical quality compared to SN60WF, whereas under ISO-2 corneal measurement conditions, the optical quality of both IOLs was similar.Under the 3.0 mm aperture, the MTF values of SN60WF and A1-UV at a decentration of 0.3 mm and 100 lp/mm spatial frequency were 0.414 and 0.571 under ISO-1 corneal measurement conditions, 0.438 and 0.512 under ISO-2 corneal measurement conditions, respectively.The MTF values of SN60WF and A1-UV at a tilt of 3° were 0.522 and 0.597 under ISO-1 corneal measurement conditions, and 0.532 and 0.531 under ISO-2 corneal measurement conditions.The MTF values and USAF resolution test chart of A1-UV had no significant change between the two corneal measurement conditions.When subjected to equal degrees of decentration or tilting, except for the ISO-1 corneal measurement conditions at a 4.5 mm aperture, the MTF values of A1-UV showed a gradual decline across various spatial frequencies compared to SN60WF.With the increase in aperture size, the impact of IOL decentration or tilting on MTF values and USAF 1951 resolution test chart became more notable for A1-UV relative to SN60WF.Conclusions:The SN60WF IOL effectively filters blue light within the wavelength range of 400-500 nm.However, when both IOL experience decentration greater than 0.3 mm or tilting beyond 3°, the optical quality of the IOL will decline.A1-UV has a distinct advantage over SN60WF in terms of resistance to both decentration and tilting-induced optical performance degradation in vitro.
4.Correlations of pontine biological indicators on fetal brain median sagittal MRI with gestational week
Lingxiu HOU ; Bingguang LIU ; Ying YUAN ; Yimei LIAO ; Qiaozhen ZHU ; Hongbo GUO ; Ying TAN ; Huiying WEN ; Fang YAN ; Shengli LI
Chinese Journal of Medical Imaging Technology 2024;40(1):88-92
Objective To observe the correlations of pontine biological indicators on fetal brain median sagittal MRI with gestational week.Methods Data of head MRI of 226 normal fetuses without obvious abnormalities of central nervous system(normal group)and 17 fetuses with abnormalities(abnormal group)at gestational age of 23 to 38 weeks were retrospectively analyzed.Pontine biological indicators based on median sagittal MRI were obtained,including pons anteroposterior diameter(PAD),total pons area(TPA),pontine basal anteroposterior length(AP),pontine basal cranio-caudal length(CC),basis pontis area(BPA)and pontine angle of midbrain(MAP).According to the gestational week,the fetuses of normal group were divided into 8 subgroups.The distributing ranges of pontine biological indicators at different gestational weeks were analyzed,and the correlations of pontine biological indicators with gestational week in normal group were explored,and the developmental status of fetal pons in abnormal group were assessed.Results In normal group,PAD,TPA,AP,CC and BPA all showed linear positive correlation(r=0.887,0.914,0.787,0.866,0.865,all P<0.001),while MAP was not significantly correlated with gestational week(P>0.05).Among 17 fetuses in abnormal group,abnormal PAD or TPA was found each in 8 fetuses,abnormal AP was observed in 14,abnormal CC was noticed in 3 and abnormal BPA was found in 11 fetuses.Conclusion Fetal pontine biological indicators such as PAD,TPA,AP,CC and BPA on median sagittal MRI were positively correlated with gestational week,hence being able to be used for evaluating fetal pontine development.
5.Development of portable field infusion kit for first aid
Hai-Ying CHEN ; Bi-Xia LIAO ; Fei-Ping SHI ; Yu-Lan WANG ; Tan YAN
Chinese Medical Equipment Journal 2024;45(7):115-117
Objective To develop a portable field infusion kit for first aid to meet the treatment requirements in field conditions.Methods The infusion kit had its frame made of third-generation carbon fiber material and was composed of a lid and a body.The lid was equipped with embedded handles on the outer surface,a medicine module consisting of 12 mesh bags on the inner surface and LED lights on the inner and outer front side walls.The kit body had three storage layers in its upper,middle and lower parts,of which the upper layer was for supplies of infusion and hemostatic dressing,the middle layer was for medical instruments and soft bags of liquid for first aid,and the lower layer was for medical waste and sharp instruments,and the bottom of the kit was provided with telescopic drawbars and invisible rollers.Results The first-aid infusion kit facilitated the storage and utilization of kinds of infusion supplies,and lowered time consumption and workloads for transport.Conclusion The first-aid infusion kit gains advantages in reasonable layout,comprehensive functions and convenient operation,and thus is worhty promoting for casualty treatment in field conditions.[Chinese Medical Equipment Journal,2024,45(7):115-117]
6.A consensus on the management of allergy in kindergartens and primary schools
Chinese Journal of School Health 2023;44(2):167-172
Abstract
Allergic diseases can occur in all systems of the body, covering the whole life cycle, from children to adults and to old age, can be lifelong onset and even fatal in severe cases. Children account for the largest proportion of the victims of allergic disease, Children s allergies start from scratch, ranging from mild to severe, from less to more, from single to multiple systems and systemic performance, so the prevention and treatment of allergic diseases in children is of great importance, which can not only prevent high risk allergic conditions from developing into allergic diseases, but also further block the process of allergy. At present, there is no consensus on the management system of allergic children in kindergartens and primary schools. The "Consensus on Allergy Management and Prevention in Kindergartens and Primary Schools", which includes the organizational structure, system construction and management of allergic children, provides evidence informed recommendations for the long term comprehensive management of allergic children in kindergartens and primary schools, and provides a basis for the establishment of the prevention system for allergic children.
7.Exploration of the relationship between the storage time of leukodepleted red blood cell and transfusion adverse reactions
Liu HE ; Jian LIU ; Gang WU ; En WANG ; Fayan YI ; Xingshun TAN ; Shiyu ZHU ; Rui YU ; Guanghui LU ; Yan LIU ; Mei ZHAI ; Qing XIANG ; Ping LIU ; Yanhua LIAO ; Zhizhen FU ; Maolin LI ; Rong HUANG
Chinese Journal of Blood Transfusion 2023;36(10):889-891
【Objective】 To explore the relationship between the storage time of leukodepleted red blood cells and transfusion adverse reactions by analyzing the occurrence of transfusion adverse reactions of patients after leukodepleted red blood cells transfusion from four hospitals. 【Methods】 By using the electronic medical record management system, the collection and transfusion dates of leukodepleted red blood cells from four hospitals in Enshi Prefecture from 2018 to 2022, as well as the information on transfusion adverse reactions, were retrieved. 【Results】 From 2018 to 2022, a total of 697 61 bags of leukodepleted red blood cells were transfused in four hospitals, resulting in 166 cases of transfusion adverse reactions, among which 93 were allergic reactions, 63 were non hemolytic febrile reactions, and 10 were others, with a total incidence rate of transfusion adverse reactions at 0.24%. The average storage time of leukodepleted red blood cells with and without transfusion adverse reactions was (20.25±6.31) and (19.88±5.50) days, respectively. With a storage time of 7 days as the threshold, the incidence of transfusion adverse reactions was the lowest for a storage time of 15~21 days. The incidence of transfusion adverse reactions of leukodepleted red blood cells in two groups (with storage days ≤21 days and >21 days) was not statistically significant(P>0.05). 【Conclusion】 Allergic reactions were the main type of transfusion adverse reaction caused by leukodepleted red blood cells, and the incidence of transfusion adverse reactions decreased and then increased with the prolongation of the storage time of leukodepleted red blood cells. There was no significant difference in the incidence of transfusion adverse reactions with leukodepleted red blood cells stored for ≤ 21 days and >21 days.
8.Corynoxine B targets at HMGB1/2 to enhance autophagy for α-synuclein clearance in fly and rodent models of Parkinson's disease.
Qi ZHU ; Juxian SONG ; Jia-Yue CHEN ; Zhenwei YUAN ; Liangfeng LIU ; Li-Ming XIE ; Qiwen LIAO ; Richard D YE ; Xiu CHEN ; Yepiao YAN ; Jieqiong TAN ; Chris Soon HENG TAN ; Min LI ; Jia-Hong LU
Acta Pharmaceutica Sinica B 2023;13(6):2701-2714
Parkinson's disease (PD) is the most common neurodegenerative movement disease. It is featured by abnormal alpha-synuclein (α-syn) aggregation in dopaminergic neurons in the substantia nigra. Macroautophagy (autophagy) is an evolutionarily conserved cellular process for degradation of cellular contents, including protein aggregates, to maintain cellular homeostasis. Corynoxine B (Cory B), a natural alkaloid isolated from Uncaria rhynchophylla (Miq.) Jacks., has been reported to promote the clearance of α-syn in cell models by inducing autophagy. However, the molecular mechanism by which Cory B induces autophagy is not known, and the α-syn-lowering activity of Cory B has not been verified in animal models. Here, we report that Cory B enhanced the activity of Beclin 1/VPS34 complex and increased autophagy by promoting the interaction between Beclin 1 and HMGB1/2. Depletion of HMGB1/2 impaired Cory B-induced autophagy. We showed for the first time that, similar to HMGB1, HMGB2 is also required for autophagy and depletion of HMGB2 decreased autophagy levels and phosphatidylinositol 3-kinase III activity both under basal and stimulated conditions. By applying cellular thermal shift assay, surface plasmon resonance, and molecular docking, we confirmed that Cory B directly binds to HMGB1/2 near the C106 site. Furthermore, in vivo studies with a wild-type α-syn transgenic drosophila model of PD and an A53T α-syn transgenic mouse model of PD, Cory B enhanced autophagy, promoted α-syn clearance and improved behavioral abnormalities. Taken together, the results of this study reveal that Cory B enhances phosphatidylinositol 3-kinase III activity/autophagy by binding to HMGB1/2 and that this enhancement is neuroprotective against PD.
9.Advances and Applications in Animal Models of Neuroblastoma
Zhigang TAN ; Jinxin LIU ; Chuya ZHENG ; Wenfeng LIAO ; Luping FENG ; Hongli PENG ; Xiu YAN ; Zhenjian ZHUO
Laboratory Animal and Comparative Medicine 2023;43(3):288-296
Neuroblastoma (NB) is one of the most common malignant solid tumors in children, ranks fourth in the incidence of pediatric tumors, and accounts for 15% of pediatric tumor deaths in children in China. Despite the development of new treatment options, the prognosis for high-risk patients is still poor. An animal model that can replicate the tumorigenesis of NB is an important tool for the prevention and treatment of NB. However, there are currently no animal models that can simulate all features of human NB. To provide a reference for the construction of animal models and treatment of NB, this article introduced several animal models of NB that have been extensively researched: the mouse, chick embryo chorioallantoic membrane, and zebrafish models. At the same time, it elaborated on the species, construction methods, characteristics, advantages and disadvantages, and research progress in NB.
10.Construction and validation of a depression risk prediction model for patients with cognitive impairment
Li LIAO ; Xuefen LI ; Jingping SHI ; Xiaofang LI ; Lili TAN ; Chen YE ; Yan KANG
Chinese Journal of Modern Nursing 2023;29(20):2701-2707
Objective:To explore the risk factors for depression in patients with cognitive impairment and construct a prediction model to preliminarily validate the predictive performance of the model, aiming to provide medical and nursing staff with a screening tool for high-risk groups.Methods:From January 2020 to December 2021, convenience sampling was used to select 1 130 patients with cognitive impairment admitted to the Affiliated Brain Hospital of Nanjing Medical University as the research subject. The research subjects were divided into a modeling group ( n=791) and a validation group ( n=339) at a ratio of 7∶3. The influencing factors of depression in patients with cognitive impairment were determined using binomial Logistic regression and a risk prediction model was established. The predictive performance of the prediction model was tested using the receiver operating characteristic (ROC) curve. Results:The incidence of depression in 1 130 patients with cognitive impairment was 51.3% (580/1 130). Binomial Logistic regression analysis showed that the influencing factors for depression in patients included age, Activities of Daily Living Scale score, Hamilton Anxiety Scale score, Pittsburgh Sleep Quality Index score, and Lewy Body Composite Risk score ( P<0.05). In the modeling group, the area under the ROC curve was 0.921, the Youden index was 0.716, the sensitivity was 0.834, the specificity was 0.882, and the prediction accuracy was 0.858. In the validation group, the area under the ROC curve was 0.896, the Youden index was 0.651, the sensitivity was 0.824, the specificity was 0.827, and the prediction accuracy was 0.825. Conclusions:The depression risk prediction model can effectively predict the risk of depression in patients with cognitive impairment, and can provide a screening tool for high-risk groups for medical and nursing staff.


Result Analysis
Print
Save
E-mail