1.Efficacy and safety of nicorandil and ticagrelor de-escalation after percutaneous coronary intervention for elderly patients with acute coronary syndrome
Xiang SHAO ; Ning BIAN ; Hong-Yan WANG ; Hai-Tao TIAN ; Can HUA ; Chao-Lian WU ; Bei-Xing ZHU ; Rui CHEN ; Jun-Xia LI ; Tian-Chang LI ; Lu MA
Medical Journal of Chinese People's Liberation Army 2024;49(1):75-81
Objective To explore the efficacy and safety of ticagrelor de-escalation and nicorandil therapy in elderly patients with acute coronary syndrome(ACS)after percutaneous coronary intervention(PCI).Methods A total of 300 elderly patients with ACS were selected from the Sixth and Seventh Medical Center of Chinese PLA General Hospital and Beijing Chaoyang Integrative Medicine Emergency Rescue and First Aid Hospital from November 2016 to June 2019,including 153 males and 147 females,aged>65 years old.All the patients received PCI,and all had double antiplatelet therapy(DAPT)scores≥2 and a new DAPT(PRECISE-DAPT)score of≥25.All patients were divided into two groups by random number table method before operation:ticagrelor group(n=146,ticagrelor 180 mg load dose followed by PCI,and ticagrelor 90 mg bid after surgery)and ticagrelor de-escalation + nicorandil group(n=154,ticagrelor 180 mg load dose followed by PCI,ticagrelor 90 mg bid+nicorandil 5 mg tid after surgery,changed to ticagrelor 60 mg bid+ nicorandil 5 mg tid 6 months later).Follow-up was 12 months.The composite end points of cardiovascular death,myocardial infarction and stroke,the composite end points of mild hemorrhage,minor hemorrhage,other major hemorrhage and major fatal/life-threatening hemorrhage as defined by the PLATO study,and the composite end points of cardiovascular death,myocardial infarction,stroke and bleeding within 12 months in the two groups were observed.Results The comparison of general baseline data between the two groups showed no statistically significant difference(P>0.05).There was also no significant difference in the composite end points of cardiovascular death,myocardial infarction and stroke between the two groups(P>0.05).The cumulative incidence of bleeding events in ticagrelor de-escalation + nicorandil group was significantly lower than that in ticagrelor group(P<0.05),while the composite end points of cardiovascular death,myocardial infarction,stroke and bleeding were also significantly lower than those in tecagrelor group(P<0.05).Conclusion In elderly patients with ACS,the treatment of ticagrelor de-escalation + nicorandil after PCI may not increase the incidence of ischemic events such as cardiovascular death,myocardial infarction or stroke,and it may reduce the incidence of hemorrhagic events.
2.Inhibition of S100A4 expression in omalizumab on IgE induced mast cell activation
Lei YANG ; Yan-Yan LI ; Chang-E FAN ; Hui-Jiao CAI ; Hua ZHEN
The Chinese Journal of Clinical Pharmacology 2024;40(17):2513-2517
Objective To investigate the effect of inhibiting S100A4 expression to enhance the dissociation of mast cells pre-bound by immunoglobulin E(IgE)by omalizumab(OmAb).Methods LAD2 cells were randomly divided into normal group,IgE group(IgE induction),OmAb-L group(0.5 mg·mL-1 OmAb),OmAb-M group(1.0 mg·mL-1 OmAb),OmAb-H group(2.0 mg·mL-1 OmAb),OmAb-h+si-S100A4 group(transfected with si-S100A4+2.0 mg·mL-1 OmAb).IgE levels on cell surface were detected by flow cytometry;degranulation was measured by β-amino-hexosidase release assay;the levels of histamine and leukotriene C4 were detected by enzyme-linked immunosorbent assay(ELISA);the expression of related proteins was detected by Western blot.Results After 6 h treatment,IgE levels in normal group,IgE group,OmAb-H group and OmAb-H+si-S100A4 group were(4.13±0.52)%,(100.00±6.20)%,(60.12±3.41)%and(54.04±5.60)%,respectively;β-amino-hexosidase release rates were(12.59±1.35),(69.27±6.43),(45.39±2.14)and(37.80±2.77)%,respectively;histamine levels were(2.43±0.16),(8.57±0.41),(4.91±0.24),(3.01±0.23)ng·mL-1,respectively;the C4 levels of leukotriene were(198.85±18.91),(423.56±1.25),(273.68±17.11)and(242.79±12.44)pg·mL-1,respectively;relative phosphorylated extracellular signal-regulated kinases(p-ERK)expression levels were 0.31±0.04,0.91±0.12,0.55±0.04 and 0.35±0.02,respectively.The above indexes in IgE group were compared with those in normal group,the above indexes of OmAb-H group were compared with IgE group,the above indexes of OmAb-H+si-S100A4 group were respectively compared with those of OmAb-H group,the differences were statistically significant(all P<0.05).Conclusion Inhibition of S100A4 can enhance the dissociation effect of OmAb on mast cells and IgE,and further block the release of allergic mediators.
3.TCM Guidelines for Diagnosis and Treatment of Chronic Cough in Children
Xi MING ; Liqun WU ; Ziwei WANG ; Bo WANG ; Jialin ZHENG ; Jingwei HUO ; Mei HAN ; Xiaochun FENG ; Baoqing ZHANG ; Xia ZHAO ; Mengqing WANG ; Zheng XUE ; Ke CHANG ; Youpeng WANG ; Yanhong QIN ; Bin YUAN ; Hua CHEN ; Lining WANG ; Xianqing REN ; Hua XU ; Liping SUN ; Zhenqi WU ; Yun ZHAO ; Xinmin LI ; Min LI ; Jian CHEN ; Junhong WANG ; Yonghong JIANG ; Yongbin YAN ; Hengmiao GAO ; Hongmin FU ; Yongkun HUANG ; Jinghui YANG ; Zhu CHEN ; Lei XIONG
Journal of Nanjing University of Traditional Chinese Medicine 2024;40(7):722-732
Following the principles of evidence-based medicine,in accordance with the structure and drafting rules of standardized documents,based on literature research,according to the characteristics of chronic cough in children and issues that need to form a consensus,the TCM Guidelines for Diagnosis and Treatment of Chronic Cough in Children was formulated based on the Delphi method,expert discussion meetings,and public solicitation of opinions.The guideline includes scope of application,terms and definitions,eti-ology and diagnosis,auxiliary examination,treatment,prevention and care.The aim is to clarify the optimal treatment plan of Chinese medicine in the diagnosis and treatment of this disease,and to provide guidance for improving the clinical diagnosis and treatment of chronic cough in children with Chinese medicine.
4.Comparative study on cleansing effect of microbubble toothbrush and conventional pulsed oral irrigator
Ke-An YUE ; Wen-Xia HUANG ; Ming-Fu ZHANG ; Gui-Hua YAN ; Chang-Wei YANG ; Fei-Fei HONG ; Lu YIN
Chinese Medical Equipment Journal 2024;45(9):67-72
Objective To compare the oral cleansing effects of the microbubble toothbrush and the conventional pulsed oral irrigator to provide references for users.Methods Ninety identical 3D-printed resin tooth models were grouped and subjected to repeated experiments,which were divided randomly into five groups including a microbubble toothbrush high-speed gear(GN-H)group,a microbubble toothbrush medium-speed gear(GN-M)group,a microbubble low-speed gear(GN-L)group,a conventional pulsed oral irrigator high-speed gear(W-H)group and a conventional pulsed oral irrigator low-speed gear(W-L)group,with 18 teeth in each group.The cleansing effects of the microbubble toothbrush and the conventional pulsed oral irrigator were evaluated in terms of irrigating strength and abilities for eliminating plaque and debris.Results Both the two types of water flossers were provided with high irrigating strength and effectively reduced plaque and debris on tooth surfaces,and the GN-H,GN-M and GN-L groups behaved better significantly than the remained groups.The order of the five groups was GN-H group>GN-M group>W-H group>GN-L group>W-L group for irrigating strength,GN-H group>GN-M group>GN-L group>W-H group>W-L group for plaque removal,GN-H group>GN-M group>W-H group>GN-L group>W-L group for debris removal,with all the differences being statistically significant(P<0.05).Conclusion Both the two types of water flossers remove plaque and debris effectively,while the microbubble toothbrush gains advantages over the conventional pulsed oral irrigator.[Chinese Medical Equipment Journal,2024,45(9):67-72]
5.In vitro activity of β-lactamase inhibitors combined with different β-lac-tam antibiotics against multidrug-resistant Mycobacterium tuberculosis clinical strains
Jie SHI ; Dan-Wei ZHENG ; Ji-Ying XU ; Xiao-Guang MA ; Ru-Yue SU ; Yan-Kun ZHU ; Shao-Hua WANG ; Wen-Jing CHANG ; Ding-Yong SUN
Chinese Journal of Infection Control 2024;23(9):1091-1097
Objective To evaluate the in vitro effect of combinations of 5 β-lactam antibiotics with different β-lac-tamase inhibitors on the activity of multidrug-resistant Mycobacterium tuberculosis(MDR-TB),and identify the most effective combination of β-lactam antibiotics and β-lactamase inhibitors against MDR-TB.Methods MDR-TB strains collected in Henan Province Antimicrobial Resistance Surveillance Project in 2021 were selected.The mini-mum inhibitory concentrations(MIC)of 5 β-lactam antibiotics or combinations with different β-lactamase inhibitors on clinically isolated MDR-TB strains were measured by MIC detection method,and the blaC mutation of the strains was analyzed by polymerase chain reaction(PCR)and DNA sequencing.Results A total of 105 strains of MDR-TB were included in the analysis.MIC detection results showed that doripenem had the highest antibacterial activity against MDR-TB,with a MIC50 of 16 μg/mL.MIC values of most β-lactam antibiotics decreased significantly after combined with β-lactamase inhibitors.A total of 13.33%(n=14)strains had mutations in blaC gene,mainly 3 nu-cleotide substitution mutations,namely AGT333AGG,AAC638ACC and ATC786ATT.BlaC proteins Ser111 Arg and Asn213Thr enhanced the synergistic effect of clavulanic acid/sulbactam and meropenem on MDR-TB compared with synonymous single-nucleotide mutation.Conclusion The combination of doripenem and sulbactam has the strongest antibacterial activity against MDR-TB.Substitution mutations of BlaC protein Ser111 Arg and Asn213Thr enhances the sensitivity of MDR-TB to meropenem through the synergy with clavulanic acid/sulbactam.
6.Curcumin attenuates calcium oxalate crystal-induced renal injury via regulation of TLR4/NF-κB and NRF2/HO-1 pathways in mouse model
Yan-Feng HE ; Wen-Bin LAI ; Wen-Wei CHEN ; Chang-Yi LIU ; Kai-Xin LU ; Hua ZHANG ; Tao JIANG ; Rui GAO
Chinese Pharmacological Bulletin 2024;40(9):1701-1708
Aim To investigate the protective effects of curcumin(CUR)on crystal-induced renal injury and its underlying mechanism in the mouse model of neph-rolithiasis.Methods The mouse model of stone for-mation was established via successive intraperitoneal injection of glyoxylate.Proximal tubular epithelial cell line HK-2 treated with calcium oxalate monohydrate(COM)was used as an in vitro model.The protective role of CUR on nephrolithiasis was tested by determina-tion of tubular injury,crystal deposition and adhesion,levels of inflammatory cytokines.In vitro,the effects of CUR on the cell viability and inflammatory factors of HK-2 cells were measured.The proteins in the Toll-like receptor 4(TLR4)/nuclear factor κB(NF-κB)and nuclear factor erythroid 2-related factor 2(NRF2)/hemeoxygenase-1(HO-1)signaling path-ways were measured by Western blot for confirming the relationship between CUR and these pathways.Final-ly,NRF2 inhibitor ML385 and TLR4 activator CCL-34 were respectively used on COM-induced HK-2 cells ex-posed to CUR for the conduction of gain-of-function and loss-of-function assays.Results CUR improves the damage in the mouse model of kidney stone forma-tion,inhibits inflammation and antioxidative effects;promotes the viability of HK-2 cells induced by COM,and inhibits the expression of inflammatory factors.CUR suppresses the expression of proteins in the TLR4/NF-κB pathway,promotes the transfer of NRF2 from the cytoplasm to the nucleus,and enhances the ex-pression of HO-1.ML385 and CCL-34 respectively counteract the anti-inflammatory effects of CUR on COM-induced HK-2 cells.Conclusions Taken togeth-er,our study demonstrates the protective effect of CUR on the deposition of kidney stone and consequent tubu-lar injury.CUR through regulation of the TLR4/NF-κB and NRF2/HO-1 pathways improves renal injury.
7.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
8.Epidemiological Survey of Hemoglobinopathies Based on Next-Generation Sequencing Platform in Hunan Province, China.
Hui XI ; Qin LIU ; Dong Hua XIE ; Xu ZHOU ; Wang Lan TANG ; De Guo TANG ; Chun Yan ZENG ; Qiong WANG ; Xing Hui NIE ; Jin Ping PENG ; Xiao Ya GAO ; Hong Liang WU ; Hao Qing ZHANG ; Li QIU ; Zong Hui FENG ; Shu Yuan WANG ; Shu Xiang ZHOU ; Jun HE ; Shi Hao ZHOU ; Fa Qun ZHOU ; Jun Qing ZHENG ; Shun Yao WANG ; Shi Ping CHEN ; Zhi Fen ZHENG ; Xiao Yuan MA ; Jun Qun FANG ; Chang Biao LIANG ; Hua WANG
Biomedical and Environmental Sciences 2023;36(2):127-134
OBJECTIVE:
This study was aimed at investigating the carrier rate of, and molecular variation in, α- and β-globin gene mutations in Hunan Province.
METHODS:
We recruited 25,946 individuals attending premarital screening from 42 districts and counties in all 14 cities of Hunan Province. Hematological screening was performed, and molecular parameters were assessed.
RESULTS:
The overall carrier rate of thalassemia was 7.1%, including 4.83% for α-thalassemia, 2.15% for β-thalassemia, and 0.12% for both α- and β-thalassemia. The highest carrier rate of thalassemia was in Yongzhou (14.57%). The most abundant genotype of α-thalassemia and β-thalassemia was -α 3.7/αα (50.23%) and β IVS-II-654/β N (28.23%), respectively. Four α-globin mutations [CD108 (ACC>AAC), CAP +29 (G>C), Hb Agrinio and Hb Cervantes] and six β-globin mutations [CAP +8 (C>T), IVS-II-848 (C>T), -56 (G>C), beta nt-77 (G>C), codon 20/21 (-TGGA) and Hb Knossos] had not previously been identified in China. Furthermore, this study provides the first report of the carrier rates of abnormal hemoglobin variants and α-globin triplication in Hunan Province, which were 0.49% and 1.99%, respectively.
CONCLUSION
Our study demonstrates the high complexity and diversity of thalassemia gene mutations in the Hunan population. The results should facilitate genetic counselling and the prevention of severe thalassemia in this region.
Humans
;
beta-Thalassemia/genetics*
;
alpha-Thalassemia/genetics*
;
Hemoglobinopathies/genetics*
;
China/epidemiology*
;
High-Throughput Nucleotide Sequencing
9.Application of acellular dermal matrix in periodontal soft tissue augmentation surgery.
Bao Chun TAN ; Chang Xing CHEN ; Fu Hua YAN
Chinese Journal of Stomatology 2023;58(2):201-208
The substitute materials of autologous tissue graft for periodontal soft tissue augmentation surgery develop rapidly. The use of substitute material can avoid the second operation area, shorten the operation time, reduce the postoperative reaction and pain, and is not limited by the quantity, suitable for a wide range of cases. In this paper, the characteristics, histological study, clinical application and therapeutic effect of acellular dermal matrix as a substitute material for autologous tissue transplantation were introduced to provide reference for clinical work.
Acellular Dermis
;
Wound Healing

Result Analysis
Print
Save
E-mail