1.The effect of Ba Duan Jin on the balance of community-dwelling older adults: a cluster randomized control trial
Leilei DUAN ; Yubin ZHAO ; Yuliang ER ; Pengpeng YE ; Wei WANG ; Xin GAO ; Xiao DENG ; Ye JIN ; Yuan WANG ; Cuirong JI ; Xinyan MA ; Cong GAO ; Yuhong ZHAO ; Suqiu ZHU ; Shuzhen SU ; Xin'e GUO ; Juanjuan PENG ; Yan YU ; Chen YANG ; Yaya SU ; Ming ZHAO ; Lihua GUO ; Yiping WU ; Yangnu LUO ; Ruilin MENG ; Haofeng XU ; Huazhang LIU ; Huihong RUAN ; Bo XIE ; Huimin ZHANG ; Yuhua LIAO ; Yan CHEN ; Linhong WANG
Chinese Journal of Epidemiology 2024;45(2):250-256
Objective:To assess the effectiveness of a 6-month Ba Duan Jin exercise program in improving the balance of community-dwelling older adults.Methods:A two arms, parallel-group, cluster randomized controlled trial was conducted in 1 028 community residents aged 60-80 years in 40 communities in 5 provinces of China. Participants in the intervention group (20 communities, 523 people) received Ba Duan Jin exercise 5 days/week, 1 hour/day for 6 months, and three times of falls prevention health education, and the control group (20 communities, 505 people) received falls prevention health education same as the intervention group. The Berg balance scale (BBS) score was the leading outcome indicator, and the secondary outcome indicators included the length of time of standing on one foot (with eyes open and closed), standing in a tandem stance (with eyes open and closed), the closed circle test, and the timed up to test.Results:A total of 1 028 participants were included in the final analysis, including 731 women (71.11%) and 297 men (28.89%), and the age was (69.87±5.67) years. After the 3-month intervention, compared with the baseline data, the BBS score of the intervention group was significantly higher than the control group by 3.05 (95% CI: 2.23-3.88) points ( P<0.001). After the 6-month intervention, compared with the baseline data, the BBS score of the intervention group was significantly higher than the control group by 4.70 (95% CI: 4.03-5.37) points ( P<0.001). Ba Duan Jin showed significant improvement ( P<0.05) in all secondary outcomes after 6 months of exercise in the intervention group compared with the control group. Conclusions:This study showed that Ba Duan Jin exercise can improve balance in community-dwelling older adults aged 60-80. The longer the exercise time, the better the improvement.
2.Comparison on the efficacy of Chinese-made novel-designed mechanical-locked and elastic self-locked transcatheter edge-to-edge repair system in the treatment of patients with functional mitral regurgitation.
Da ZHU ; Shou Zheng WANG ; Zhi Ling LUO ; Jia Hua PAN ; Ke YANG ; Chun Mei XIE ; Yong Yan TANG ; Hong Bo YANG ; Mi Er MA ; Jian Bin GAO ; Xiang Bin PAN
Chinese Journal of Cardiology 2023;51(8):832-837
Objective: To evaluate and compare the short-term efficacy of domestic mechanical-locked (Clip2Edge) and elastic self-locked (ValveClip) transcranial mitral valve edge-to-edge interventional repair (TEER) devices in the treatment of functional mitral regurgitant valves. Methods: In this retrospective non-randomized comparative study, patients underwent TEER procedure in Fuwai Yunnan Cardiovascular Disease Hospital from May 2022 to April 2023 for heart failure combined with moderate to severe or severe functional mitral valve were divided into Clip2Edge and ValveClip groups based on the TEER system used. Baseline, perioperative, and postoperative 30 d follow-up data were collected and compared between the two groups. The primary outcome was the success rate on the 30 d post operation, while secondary outcomes included immediate postoperative technical success rate and the incidence of all-cause mortality on the 30 d post operation, readmission rate of acute heart failure, cerebral infarction, severe bleeding, and other serious adverse events rates. Results: A total of 60 patients were enrolled, 34 patients were in the Clip2Edge group and 26 in the ValveClip group, mean age was (63.8±9.3) years, and 24 patients (40%) were female. There were no significant differences in baseline data of age, cardiac function, comorbidities, mitral regurgitation 4+(19(73%) vs. 29(85%)), the end-diastolic volume of left ventricle ((220.8±91.2) ml vs. (210.8±71.7) ml) between the two groups (all P>0.05). The technical success rate immediately after the procedure was 100%. There were no readmission of acute heart failure, death, cerebral infarction, severe bleeding, and other serious adverse events up to the 30 d follow-up. Device success rate was similar between the ValveClip group (24 cases (100%)) and the Clip2Edge group (27 cases (96%)) (P>0.05). Conclusion: Both types of novel domestic TEER devices are safe and feasible in treating patients with functional mitral regurgitation.
Humans
;
Female
;
Middle Aged
;
Aged
;
Male
;
Mitral Valve Insufficiency/etiology*
;
Retrospective Studies
;
East Asian People
;
Heart Valve Prosthesis Implantation
;
Treatment Outcome
;
China
;
Heart Failure/etiology*
;
Cardiac Catheterization
3.Surveillance of adverse events following immunization with inactivated influenza vaccines among the elderly in Huzhou City
ZHANG Chao ; LUO Xiaofu ; LIU Yan ; SHEN Jianyong ; XU Qin' ; er ; HAN Liping ; MA Li
Journal of Preventive Medicine 2023;35(8):701-704
Objective:
To investigate the incidence of adverse events following immunization (AEFI) with inactivated influenza vaccine among the elderly in Huzhou City, Zhejiang Province, so as to provide insights into safety monitoring and evaluation of inactivated influenza vaccines.
Methods:
Data pertaining to surveillance on AEFI with inactivated influenza vaccines among the elderly at ages of 60 years and older in Huzhou City from 2020 to 2022 were collected from the AEFI Monitoring Information Management System of the Immunization Planning System of Chinese Disease Control and Prevention Information System, including demographics, time of AEFI occurrence, classification of AEFI and clinical syndromes, and the reported incidence and epidemiological features of AEFI with inactivated influenza vaccines were analyzed using a descriptive epidemiological method.
Results:
Totally 84 elderly cases at ages of 60 years and older were reported with AEFI with inactivated influenza vaccines in Huzhou City from 2020 to 2022, with a reported incidence rate of 9.83/105 doses, and the reported incidence rates of AEFI with trivalent and quadrivalent inactivated influenza vaccines were 9.74/105 doses and 48.71/105 doses, respectively. The reported incidence rates of general, abnormal, coincidence and psychogenic reactions were 7.96/105 doses, 1.52/105 doses, 0.23/105 doses and 0.12/105 doses, respectively, and no vaccine quality accidents or wrong vaccine administered were reported. The cases with AEFI included 52 women and 32 men, and most cases were aged from 60 to 69 years (44 cases, 52.38%). The highest incidence of AEFI was reported in Nanxun District (17.94/105 doses), and there were 79 cases (94.05%) with AEFI within 24 hours following vaccination. The clinical symptoms mainly included fever, local redness and swelling, and local induration, with reported incidence rates of 2.22/105 doses, 3.74/105 doses, and 1.99/105 doses, respectively.
Conclusions
The reported incidence of AEFI with inactivated influenza vaccines is low among the elderly at ages of 60 years and older in Huzhou City, with general reactions as predominant AEFI, and most AEFI occurs within 24 hours following vaccination.
4.Comparison on the efficacy of Chinese-made novel-designed mechanical-locked and elastic self-locked transcatheter edge-to-edge repair system in the treatment of patients with functional mitral regurgitation.
Da ZHU ; Shou Zheng WANG ; Zhi Ling LUO ; Jia Hua PAN ; Ke YANG ; Chun Mei XIE ; Yong Yan TANG ; Hong Bo YANG ; Mi Er MA ; Jian Bin GAO ; Xiang Bin PAN
Chinese Journal of Cardiology 2023;51(8):832-837
Objective: To evaluate and compare the short-term efficacy of domestic mechanical-locked (Clip2Edge) and elastic self-locked (ValveClip) transcranial mitral valve edge-to-edge interventional repair (TEER) devices in the treatment of functional mitral regurgitant valves. Methods: In this retrospective non-randomized comparative study, patients underwent TEER procedure in Fuwai Yunnan Cardiovascular Disease Hospital from May 2022 to April 2023 for heart failure combined with moderate to severe or severe functional mitral valve were divided into Clip2Edge and ValveClip groups based on the TEER system used. Baseline, perioperative, and postoperative 30 d follow-up data were collected and compared between the two groups. The primary outcome was the success rate on the 30 d post operation, while secondary outcomes included immediate postoperative technical success rate and the incidence of all-cause mortality on the 30 d post operation, readmission rate of acute heart failure, cerebral infarction, severe bleeding, and other serious adverse events rates. Results: A total of 60 patients were enrolled, 34 patients were in the Clip2Edge group and 26 in the ValveClip group, mean age was (63.8±9.3) years, and 24 patients (40%) were female. There were no significant differences in baseline data of age, cardiac function, comorbidities, mitral regurgitation 4+(19(73%) vs. 29(85%)), the end-diastolic volume of left ventricle ((220.8±91.2) ml vs. (210.8±71.7) ml) between the two groups (all P>0.05). The technical success rate immediately after the procedure was 100%. There were no readmission of acute heart failure, death, cerebral infarction, severe bleeding, and other serious adverse events up to the 30 d follow-up. Device success rate was similar between the ValveClip group (24 cases (100%)) and the Clip2Edge group (27 cases (96%)) (P>0.05). Conclusion: Both types of novel domestic TEER devices are safe and feasible in treating patients with functional mitral regurgitation.
Humans
;
Female
;
Middle Aged
;
Aged
;
Male
;
Mitral Valve Insufficiency/etiology*
;
Retrospective Studies
;
East Asian People
;
Heart Valve Prosthesis Implantation
;
Treatment Outcome
;
China
;
Heart Failure/etiology*
;
Cardiac Catheterization
5.Application of routine laboratory data in combination with machine learning in the differential diagnosis of lung tuberculosis
Yan WANG ; Huarong ZHENG ; Yifei LUO ; Jing ER ; Qingtao WANG ; Rui ZHOU ; Yufang LIANG ; Biao SONG ; Dawei HUANG
Chinese Journal of Laboratory Medicine 2022;45(12):1201-1206
Objective:To investigate the application value of establishing the differential diagnosis model of pulmonary tuberculosis using routine laboratory data.Methods:The retrospective study was conducted. The routine laboratory data of newly diagnosed patients with pulmonary tuberculosis and other pulmonary diseases in Beijng Jishuitan Hospital and Beijing Hepingli Hospital from May 2015 to November 2021were collected. According to the random numbers showed in the computer, all the 11516 patients were divided into training dataset and test dataset with a ratio of 9∶1. Four machine learning algorithms, Support Vector Machine, Random Forest, K-Nearest Neighbor and Logistic Regression, were used to build models and select features. The diagnostic accuracy of each model was verified by using the 10-fold cross-validation method and the performance of each model was evaluated by using the receptor operator of characteristic (ROC) curve.Results:Random Forest was selected as the optimal machine learning algorithm to build the best feature model in the study. According to importance scale of factors, the differential diagnosis model of pulmonary tuberculosis consisting of 37 non-specific test indexes. In the validation set and test set the accuracy and area under curve (AUC) of the models were 0.747 and 0.736, the sensitivity, specificity and accuracy were 68.03% and 68.75%, 70.91% and 67.90%, 70.30% and 68.12%, respectively.Conclusion:A key tool in the differential diagnosis model of pulmonary tuberculosis was established by routine laboratory data in combination with machine learning. The results of this study need to be further verified by more data from medical institutions.
6.Visual Electrophysiological Diagnosis and Treatment Technology for Early Intervention of Urinary Incontinence After TUERP
Dao-sheng LUO ; Jian-jun LU ; Wei-ning LIANG ; Yan-chuan ZOU ; Jun-hua MO ; Shu-er CHEN ; Chun-hua DENG
Journal of Sun Yat-sen University(Medical Sciences) 2022;43(6):878-883
ObjectiveTo summarize the effect of visual electrophysiological diagnosis and treatment technology on postoperative urinary incontinence in early intervention after transurethral enucleation and resection of the prostate (TUERP). MethodsTotally 86 patients with benign prostatic hyperplasia (BPH) who underwent TUERP in the Puji Branch Hospital of Dongguan People's Hospital from December 2020 to June 2022 were selected as the treatment group, who received electrophysiological treatment after postoperative removal of the catheter on the 6th day after surgery, while 79 cases who received no electrophysiological treatment after surgery were selected as the control group. The urinary incontinence rates of the two groups on the 6th day, at 1 month and 3 months after surgery were observed. ResultsThere was no statistical difference between the two groups in the preoperative basic data. The rates of urinary incontinence after removal of the catheter in the two groups on the 6th day after surgery were 13 cases (15.1%) in the treatment group and 12 cases (15.2%) in the control group. There was no significant difference between the two groups (P >0.05), and the overall postoperative urinary incontinence rate in the two groups was 15.2% (25/165). At one month after surgery, only 4 cases (4.65%) had slight urinary incontinence in the treatment group, while 13 cases (16.5%) in the control group still had urinary incontinence, and the difference between the two groups was statistically significant ( P=0.019). After follow-up to three months after operation, there was no case of urinary incontinence in the treatment group, and there were still 7 cases (8.86%) of urinary incontinence in the control group. The difference between the two groups was statistically significant (P=0.005). ConclusionThe early intervention of visual electrophysiological diagnosis and treatment technology can effectively prevent the occurrence of urinary incontinence after TUERP, and has good value in clinical application.
8.Feasibility Study of Intelligent Automatic Registration Ultrasound-CT/MR Fusion Imaging Based on Liver Surface
Qing-jing ZENG ; Rong-hua YAN ; Yu-xuan WU ; Ying-lin LONG ; Li-ping LUO ; Kai LI ; Er-jiao XU ; Rong-qin ZHENG
Journal of Sun Yat-sen University(Medical Sciences) 2019;40(1):117-123
【Objective】To explore the feasibility and simplicity of intelligent automatic registration ultrasound-CT/ MR fusion imaging based on liver surface in localization of focal liver lesions. 【Methods】 Thirty patients with detected focal liver lesions by contrast- enhanced CT or MR were enrolled for ultrasound- CT/MR fusion imaging using the PercuNav fusion imaging system in PHILPS EPIQ7. Both intelligent automatic registration ultrasound- CT/MR fusion imaging based on liver surface(intelligent method)and the conventional internal plane method(manual method)were used for ultrasound-CT/MR fusion imaging. The success rate of registration,the initial registration error and the times of fine-tuning were compared between these two methods.【Results】In all 30 patients,the success rates of registration were both 96.67%(29/30)using intelligent method and manual method. There was no significant difference between these two methods when compared the initial registration error and the times of fine- tuning (P>0.05). According to the further stratified analysis,in 10 lesions in the left liver,the initial registration error of the manual method was less than that of intelligent method,the difference was statistically significant(P=0.00). Although the times of fine-tuning of the manual method was less than that of intelligent method,there was no statistically significant difference(P=0.09);In 20 lesions in the right liver,the initial registration error and the times of fine-tuning of the intelligent method were superior to those of the manual method. The differences were statistically significant (P<0.05). 【Conclusion】 Intelligent automatic registration ultrasound- CT/MR fusion imaging based on liver surface is a feasible method with high success rate for ultrasound-CT/MR fusion imaging. Compared with the conventional internal plane method,the fusion imaging process is more simple and efficient for the lesions in right liver. It helps to reduce experience dependence of fusion imaging for the operators.
9.Biomechanics study on implant-natural tooth supported fixed partial dentures
Wei LIU ; min Er NIE ; Rui JIANG ; yuan Chun ZHANG ; xun Zhe HUANG ; hang Yu ZHANG ; jie Jian SHI ; yu Yong HUANG ; Bao LUO ; Yun YAN-XIANG ; Liang XUE
Chinese Journal of Tissue Engineering Research 2017;21(32):5146-5151
BACKGROUND: The stress distribution is different between implants and natural teeth, and the biomechanical characters of implant-natural tooth supported fixed partial dentures need to be explored.OBJECTIVE: To analyze the distributions of stress and strain on the implant interface and natural tooth ligaments by loading a vertical force to a single implant crown, natural tooth crown and a implant-natural tooth supported fixed partial denture.METHODS: Two male healthy Beagle dogs were selected, and their right mandibular first molars were exacted under general anesthesia. Three months later, a 3.3 mm×10 mm RN ITI implant was implanted into the defect region of each dog. The dogs were killed under anesthesia after another 3 months to remove the mandible. One dog was restored by a single implant and natural tooth crown, and the other was restored by the implant-natural tooth supported fixed partial dentures. The specimens were fixed to the load device after embedded with self caring acrylic resin, and the strain gauges were pasted to the cortical bone around the implant and natural tooth neck. The vertical force was loaded to the implant, natural tooth and fixed denture with 40, 60, 80,120, and 160 N.RESULTS AND CONCLUSION: When the force was loaded to the implant of combined denture, the implant stress of combined denture was less than that of the single implant repair, and partial force was loaded on natural teeth; when the force was loaded to the natural tooth of combined denture, the stress to the natural tooth of combined denture was less than that of the single natural tooth repair. When the force was loaded to the natural tooth of combined denture, the stress was assumed by the whole prostheses. However, the stress was almost assumed by the implant when the force was loaded to the implant of combined denture. That is to say, it is feasible to use the implant-natural tooth supported fixed partial dentures.
10.Development of LabVIEW-based loading system for cellular shear stress and its experimental validation
dong Ze YAN ; ping Er LUO ; Pan WANG ; wan Meng LIU ; ming Ming ZHAI ; hui Xu ZHANG ; yu Xi LIU ; Da JING
Chinese Medical Equipment Journal 2017;38(11):5-9
Objective To develop a cellular shear stress loading system with an adjustable stress mode and relevant parameters, and subsequently verify the effectiveness and feasibility of this system. Methods The hardware of the system was developed by using a peristaltic pump and self-designed multi-channel flow chamber, and the mode control program of shear stress based on LabVIEW was designed to control the device via RS485 interfacing and Modbus protocol. Additionally, the relationship between the shear stress and system parameters was calibrated, and finite element analysis was also conducted. Finally, the feasibility of the system was confirmed via the in vitro cell experiment. Results The mode and magnitude of shear stress of the system could be controlled via either the peristaltic pump or computer, and the cellular long-term effect was also able to be detected. The calibration results of the system indicated that the level of shear stress exhibited significantly linear positive correlation with the revolution of the peristaltic pump (P<0.001). Finite element analysis demonstrated that the level of shear stress on the slide was uniformly distributed and the result of simulation was accordant with calibration. Cytoskeleton staining suggested that cellular morphology of MLO-Y4 cells was changed, and microfilament increased and arrayed along fluid flow direction. Conclusion The system is stable and reliable enough to provide different loading modes and magnitude of cellular shear stress to offer a convictive platform of the research for different cellular stress signal transduction mecha-nisms.


Result Analysis
Print
Save
E-mail