1.Severity Assessment Parameters and Diagnostic Technologies of Obstructive Sleep Apnea
Zhuo-Zhi FU ; Ya-Cen WU ; Mei-Xi LI ; Ping-Ping YIN ; Hai-Jun LIN ; Fu ZHANG ; Yu-Xiang YANG
Progress in Biochemistry and Biophysics 2025;52(1):147-161
Obstructive sleep apnea (OSA) is an increasingly widespread sleep-breathing disordered disease, and is an independent risk factor for many high-risk chronic diseases such as hypertension, coronary heart disease, stroke, arrhythmias and diabetes, which is potentially fatal. The key to the prevention and treatment of OSA is early diagnosis and treatment, so the assessment and diagnostic technologies of OSA have become a research hotspot. This paper reviews the research progresses of severity assessment parameters and diagnostic technologies of OSA, and discusses their future development trends. In terms of severity assessment parameters of OSA, apnea hypopnea index (AHI), as the gold standard, together with the percentage of duration of apnea hypopnea (AH%), lowest oxygen saturation (LSpO2), heart rate variability (HRV), oxygen desaturation index (ODI) and the emerging biomarkers, constitute a multi-dimensional evaluation system. Specifically, the AHI, which measures the frequency of sleep respiratory events per hour, does not fully reflect the patients’ overall sleep quality or the extent of their daytime functional impairments. To address this limitation, the AH%, which measures the proportion of the entire sleep cycle affected by apneas and hypopneas, deepens our understanding of the impact on sleep quality. The LSpO2 plays a critical role in highlighting the potential severe hypoxic episodes during sleep, while the HRV offers a different perspective by analyzing the fluctuations in heart rate thereby revealing the activity of the autonomic nervous system. The ODI provides a direct and objective measure of patients’ nocturnal oxygenation stability by calculating the number of desaturation events per hour, and the biomarkers offers novel insights into the diagnosis and management of OSA, and fosters the development of more precise and tailored OSA therapeutic strategies. In terms of diagnostic techniques of OSA, the standardized questionnaire and Epworth sleepiness scale (ESS) is a simple and effective method for preliminary screening of OSA, and the polysomnography (PSG) which is based on recording multiple physiological signals stands for gold standard, but it has limitations of complex operations, high costs and inconvenience. As a convenient alternative, the home sleep apnea testing (HSAT) allows patients to monitor their sleep with simplified equipment in the comfort of their own homes, and the cardiopulmonary coupling (CPC) offers a minimal version that simply analyzes the electrocardiogram (ECG) signals. As an emerging diagnostic technology of OSA, machine learning (ML) and artificial intelligence (AI) adeptly pinpoint respiratory incidents and expose delicate physiological changes, thus casting new light on the diagnostic approach to OSA. In addition, imaging examination utilizes detailed visual representations of the airway’s structure and assists in recognizing structural abnormalities that may result in obstructed airways, while sound monitoring technology records and analyzes snoring and breathing sounds to detect the condition subtly, and thus further expands our medical diagnostic toolkit. As for the future development directions, it can be predicted that interdisciplinary integrated researches, the construction of personalized diagnosis and treatment models, and the popularization of high-tech in clinical applications will become the development trends in the field of OSA evaluation and diagnosis.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7. Exploring mechanism of hypolipidemic effect of total Ligustrum robustum (Roxb. ) Blume on hyperlipidemic golden hamsters based on intestinal flora
Chen-Xi XU ; Rui-Le PAN ; Meng-Chen DONG ; Zhi-Hong YANG ; Xiao-Ya LI ; Wen JIN ; Run-Mei YANG
Chinese Pharmacological Bulletin 2024;40(3):476-483
Aim To evaluate the hypolipidemic effect of the total phenylpropanoid glycosides extracted from Ligustrum robustum (Roxb.) Blume (LRTPG) on hyperlipidemic golden hamsters and explore its regulatory effect on intestinal flora. Methods Sixty hamsters were randomly divided into a control group, a model group, a positive drug group, LRTPG-L group, LRTPG-M group, and LRTPG-H group. After the successful induction of the model by high-fat diet, the animals were continuously administered for four weeks, and their blood lipids and liver lipids were detected. The formed feces from the colorectal region of the hamsters in the control group, model group and LRTPG-H group were collected for 16S rDNA sequencing. Results LRTPG reduced serum TG, TC, LDL-C and liver TG, TC concentrations significantly in hyperlipidemic hamsters. The results of the intestinal microbiota sequencing showed that compared to the control group, LRTPG significantly decreased the relative abundance of the phylum Firmicutes and increased the relative abundance of the phylum Bacteroidetes and Verrucomicrobia (P < 0.01) at the phylum level. At the family level, LRTPG significantly increased the relative abundance of Christensenellaceae, Peptococcaceae, and Verrucomicrobiaceae (P < 0.05 or P < 0.01). At the genus level, LRTPG significantly increased the relative abundance of Oscillospira, Oscillibacter, Flavonifractor and Akkermansiaceae (P < 0.05 or P < 0.01). These changes in the flora were beneficial to the hypolipidemic effect of LRTPG. Conclusion LRTPG may exert its hypolipidemic effect by improving the intestinal flora disorder caused by a high-fat diet in golden hamsters.
8.Bone density and bone metabolism in plasmapheresis donors
Wan LI ; Changqing LI ; Yongjun CHEN ; Xi YANG ; Zhiwei LI ; Ya WANG
Chinese Journal of Blood Transfusion 2024;37(1):51-57
【Objective】 To investigate the level of serum bone metabolism and biochemical markers and bone density of plasmapheresis donors, and to provide scientific basis for ensuring the health and safety of plasmapheresis donors in China. 【Methods】 A total of 437 plasmapheresis donors from Linwu plasmapheresis station in Hunan Province from July 1 to September 30, 2022 were recruited to determine the levels of total serum calcium, albumin, serum 25-hydroxyvitamin D (25OHD), serum type I procollagen N-terminal propeptide (P1NP), and collagen type 1 crosslinked carboxyl-terminal peptide (β-CTX). Dual-energy X-ray method was used to measure the bone density of the anteroposterior lumbar spine (L1-L4) and bilateral femoral neck bone density of plasmapheresis donors. Plasmapheresis donors were grouped according to the type of plasma donation (first-time and repeat plasmapheresis donors) and the total number of plasma donations to assess the differences in bone density and serum bone metabolism biochemical markers between groups. The dose-response relationship between the total number of plasmapheresis donations and biochemical indexes was analyzed by limiting cubic spline, and the influencing factors of different indexes were explored by multiple linear regression. 【Results】 A total of 437 plasmapheresis donors were included in this study, including 187 first-time plasmapheresis donors and 250 repeat plasmapheresis donors. There were no significant differences in bone density and prevalence of osteoporosis between first-time donors and repeat donors (P>0.05). There was also no significant difference in bone density levels between groups of total number of plasmapheresis donations. The levels of albumin and 25OHD decreased with the increase of the total number of plasma donations, while the serum P1NP level was positively correlated with the total number of plasma donations. The results of the restriction cubic spline showed that the total number of plasmapheresis donations had a nonlinear dose-response relationship with 25OH and P1NP (P<0.05). The results of multiple linear regression showed that the frequency of plasmapheresis donation was the influencing factor of 25OHD, and the total number of plasmapheresis donation was the influencing factor of P1NP. 【Conclusion】 Plasmapheresis donation does not affect the bone health of donors and increase the risk of osteoporosis due to the use of long-term anticoagulants, but it will increase the osteogenic activity of plasmapheresis donors. It is recommended that middle-aged and elderly plasmapheresis donors supplement vitamin D appropriately.
9.Clinicopathological Features and Long-Term Prognostic Role of Human Epidermal Growth Factor Receptor-2 Low Expression in Chinese Patients with Early Breast Cancer:A Single-Institution Study
Qing Zi KONG ; Qun Li LIU ; Qin De HUANG ; Tong Yu WANG ; Jie Jing LI ; Zheng ZHANG ; Xi Xi WANG ; Ling Chuan LIU ; Di Ya ZHANG ; Kang Jia SHAO ; Min Yi ZHU ; Meng Yi CHEN ; Mei LIU ; Hong Wei ZHAO
Biomedical and Environmental Sciences 2024;37(5):457-470
Objective This study aimed to comprehensively analyze and compare the clinicopathological features and prognosis of Chinese patients with human epidermal growth factor receptor 2(HER2)-low early breast cancer(BC)and HER2-IHC0 BC. Methods Patients diagnosed with HER2-negative BC(N=999)at our institution between January 2011 and December 2015 formed our study population.Clinicopathological characteristics,association between estrogen receptor(ER)expression and HER2-low,and evolution of HER2 immunohistochemical(IHC)score were assessed.Kaplan-Meier method and log-rank test were used to compare the long-term survival outcomes(5-year follow-up)between the HER2-IHC0 and HER2-low groups. Results HER2-low BC group tended to demonstrate high expression of ER and more progesterone receptor(PgR)positivity than HER2-IHC0 BC group(P<0.001).The rate of HER2-low status increased with increasing ER expression levels(Mantel-Haenszel χ2 test,P<0.001,Pearson's R=0.159,P<0.001).Survival analysis revealed a significantly longer overall survival(OS)in HER2-low BC group than in HER2-IHC0 group(P=0.007)in the whole cohort and the hormone receptor(HR)-negative group.There were no significant differences between the two groups in terms of disease-free survival(DFS).The discordance rate of HER2 IHC scores between primary and metastatic sites was 36.84%. Conclusion HER2-low BC may not be regarded as a unique BC group in this population-based study due to similar clinicopathological features and prognostic roles.
10.Implementation of surveillance,prevention and control of healthcare-asso-ciated infection in maternal and child healthcare institutions:A nation-wide investigation report
Shuo LI ; Xi YAO ; Hui-Xue JIA ; Wei-Guang LI ; Xun HUANG ; Shu-Mei SUN ; Xi CHENG ; Qing-Lan MENG ; Xiang ZHANG ; Jing-Ping ZHANG ; Ya-Wei XING ; Qing-Qing JIANG ; Lian-Xuan WU ; Bing-Li ZHANG ; Xiao-Jing LIU ; Liu-Yi LI
Chinese Journal of Infection Control 2024;23(3):323-329
Objective To investigate the implementation of surveillance,prevention and control measures for healthcare-associated infection(HAI)in maternal and child healthcare(MCH)institutions,and provide policy evi-dence for optimizing HAI prevention and control in MCH institutions.Methods Stratified sampling was conducted among the MCH institutions at provincial,municipal and county levels in 8 provinces/autonomous regions.A uni-fied questionnaire was designed and the online survey was conducted through"Questionnaire Star".Results The data from 123 MCH institutions were included in the analysis.90.24%of the MCH institutions carried out compre-hensive surveillance on HAI.The ratios of MCH institutions which implemented targeted surveillance on HAI in neonatal intensive care unit(NICU),surgical site infection,multidrug-resistant organisms(MDROs)and HAI in intensive care units(non-NICU excluded)were 89.66%,85.96%,80.77%,and 74.19%,respectively.51.22%MCH institutions adopted information surveillance system on HAI cases.94.31%MCH institutions carried out surveillance on hand hygiene compliance.Over 90%MCH institutions carried out surveillance on environment hy-giene in high-risk departments.71.54%MCH institutions conducted centralized cleaning,disinfection,sterilization and supply for reusable medical instruments in the central sterile supply department(CSSD).Over 90%MCH insti-tutions established three-level pre-examination triage systems.86.18%set up transitional wards.MCH institutions generally adopted a management model with established effective communication,full appointment visits,and sepa-rate visits for special medical groups,such as registered pregnant women,high-risk newborns,healthcare groups,and long-term rehabilitation patients.However,the ratio of institutions conducting on-line follow-up visits was less than 50%.Conclusion MCH institutions have generally carried out comprehensive and targeted surveillance on HAI.Information surveillance need to be facilitated.Hand hygiene and environmental hygiene surveillance has been popularized to a certain extent at all levels of MCH institutions.The cleaning,disinfection,sterilization,and supply processes of reusable medical devices in a few MCH institutions are not standardized.Special medical populations get effective management.On-line healthcare is to be further promoted.

Result Analysis
Print
Save
E-mail