1.Study on the potential allergen and mechanism of pseudo-allergic reactions induced by combined using of Reduning injection and penicillin G injection based on metabolomics and bioinformatics
Yu-long CHEN ; You ZHAI ; Xiao-yan WANG ; Wei-xia LI ; Hui ZHANG ; Ya-li WU ; Liu-qing YANG ; Xiao-fei CHEN ; Shu-qi ZHANG ; Lu NIU ; Ke-ran FENG ; Kun LI ; Jin-fa TANG ; Ming-liang ZHANG
Acta Pharmaceutica Sinica 2024;59(2):382-394
Based on the strategy of metabolomics combined with bioinformatics, this study analyzed the potential allergens and mechanism of pseudo-allergic reactions (PARs) induced by the combined use of Reduning injection and penicillin G injection. All animal experiments and welfare are in accordance with the requirements of the First Affiliated Experimental Animal Ethics and Animal Welfare Committee of Henan University of Chinese Medicine (approval number: YFYDW2020002). Based on UPLC-Q-TOF/MS technology combined with UNIFI software, a total of 21 compounds were identified in Reduning and penicillin G mixed injection. Based on molecular docking technology, 10 potential allergens with strong binding activity to MrgprX2 agonist sites were further screened. Metabolomics analysis using UPLC-Q-TOF/MS technology revealed that 34 differential metabolites such as arachidonic acid, phosphatidylcholine, phosphatidylserine, prostaglandins, and leukotrienes were endogenous differential metabolites of PARs caused by combined use of Reduning injection and penicillin G injection. Through the analysis of the "potential allergen-target-endogenous differential metabolite" interaction network, the chlorogenic acids (such as chlorogenic acid, neochlorogenic acid, cryptochlorogenic acid, and isochlorogenic acid A) and
2.Investigation,traceability analysis,and discussion of food poisoning caused by Salmonella typhimurium ST19
Shu-Kun YU ; Lang LIU ; Ya-Xin TAN ; Zi-Yan CUI ; Xing-Yu XU ; Zhi-Yang TAO
Chinese Journal of Zoonoses 2024;40(1):82-89
To perform a comprehensive analysis of the pathogenic causes of a food poisoning case in a district of Wuhan Cit-y,we investigated the molecular epidemiological relationships among pathogenic bacteria,to aid in traceability analysis of food-borne disease outbreaks,as well as clinical diagnosis and treatment.The pathogenic bacteria in this food poisoning case were i-solated and identified according to GB789.4-2016.The isolated strains were subjected to genotyping with pulsed field gel elec-trophoresis(PFGE).Drug resistance gene analysis,multi-locus sequence typing(MLST),and genome-wide single-nucleotide polymorphism analysis(wgSNP)were conducted via whole genome sequencing(WGS).The evolutionary tree for cluster analy-sis was constructed in fasttree software.Drug susceptibility testing was conducted with the broth microdilution method.A total of 12 strains of Salmonella were detected in seven anal swab samples and two fecal samples from the case,as well as three anal swab samples from unaffected individuals.The serotype of the strains was Salmonella typhimurium.The strain exhibited severe multiple drug resistance,including resistance to amikacin,ampi-cillin,cefazolin,gentamicin,piperacillin,and tetracycline,but susceptibility to other antibiotics.The coincidence rate between drug resistance genes and drug resistance phenotypes was high.PFGE revealed that nine strains from this food poisoning case were highly homologous.WGS revealed that the MLST type was ST19,and varying numbers of SNPs(1-6)were present a-mong strains.The phylogenetic tree revealed nine isolated strains forming a distinct cluster,differing from other Salmonella strains in the database and belonging to a novel clonal branch.The single nucleotide site in the strains was highly homologous to that of GCF in Jiangxi_020221795.1.The food poisoning case was caused by Salmonella typhimurium ST19,and all nine iso-lated strains originated from the same source.The chef is closely connected to this food poisoning case.This strain of Salmo-nella typhimurium belongs to a new clonal branch and exhibits multiple drug resistance.
3.Effects of Electroacupuncture on Urodynamics and Expression of ERK/CREB/Bcl-2 Pathway in Spinal Cord of Rats with Neurogenic Bladder after Suprasacral Spinal Cord Injury
Ming XU ; Kun AI ; Yue ZHUO ; Qiong LIU ; Xiaomeng LIU ; Ya LI ; Xiaoyuan LUO ; Hong ZHANG
Chinese Journal of Information on Traditional Chinese Medicine 2024;31(4):100-105
Objective To observe the effects of electroacupuncture at"Ciliao","Zhongji","Sanyinjiao"and"Dazhui"on urodynamics and expression of ERK/CREB/Bcl-2 pathway in spinal cord tissue of neurogenic bladder rats after suprasacral spinal cord injury.Methods Sixty female SD rats randomly selected 24 and divided into blank group and sham-operation group(12 rats in each group),the remaining 36 rats were subjected to surgical modeling.After modeling,rats were randomly divided into the model group and the electroacupuncture group,with 12 rats in each group.The electroacupuncture group received unilateral electroacupuncture stimulation at acupoints"Ciliao","Zhongji","Sanyinjiao",and"Dazhui"for 30 minutes each time,once a day,for 7 consecutive days.After administration,urodynamic testing was performed,HE staining was used to observe the morphology of bladder detrusor tissue,TUNEL method was used to detected apoptosis in spinal cord tissue,Western blot was used to detected expressions of p-ERK1/2,p-CREB,p-p90Rsk,CRE,Bcl-2,and Bax proteins in spinal cord tissue.Results Compared with the sham-operation group,the basal pressure,maximum pressure,and leakage point pressure of the bladder in the model group increased significantly(P<0.01),while the maximum capacity and compliance of the bladder decreased significantly(P<0.01);the structure of bladder smooth muscle cells was severely damaged and disorderly arranged,accompanied by a large amount of inflammatory cell infiltration;the apoptosis rate of spinal cord tissue cells significantly increased(P<0.01),and the expressions of p-ERK1/2,p-p90Rsk,p-CREB,CRE,and Bcl-2 proteins in spinal cord tissue were significantly decreased,while the expression of Bax protein significantly increased(P<0.01).Compared with the model group,the basal pressure,maximum pressure,and leakage point pressure of the bladder in the electroacupuncture group decreased significantly(P<0.05),while the maximum capacity and compliance of the bladder increased significantly(P<0.05,P<0.01);the integrity of bladder smooth muscle cells was enhanced,the degree of cell edema was reduced,and inflammatory cell infiltration was reduced;the apoptosis rate of spinal cord tissue cells was significantly reduced(P<0.05),and the expressions of p-ERK1/2,p-p90Rsk,p-CREB,CRE,and Bcl-2 proteins in spinal cord tissue significantly increased,while the expression of Bax protein was significantly decreased(P<0.05,P<0.01).Conclusion Electroacupuncture can promote the repair of bladder detrusor tissue in rats with neurogenic bladder model after suprasacral spinal cord injury,increase the maximum capacity and compliance of the bladder,alleviate the high pressure state in the bladder,and its mechanism is related to activating the ERK/CREB/Bcl-2 pathway,reducing secondary apoptosis of damaged neurons,effectively improving bladder innervation,and protecting bladder function.
4.Nanopore Protein Sequencing
Zi-Yi LI ; Ya-Kun YI ; Lei LIU ; Hai-Chen WU
Progress in Biochemistry and Biophysics 2024;51(10):2498-2518
The success of the Human Genome Project has significantly deepened our understanding of genomics and catalyzed a growing focus on proteomics, as researchers aim to decipher the complex relationship between genes and proteins. Given the central role of proteins in regulating physiological processes—including DNA replication, metabolic reactions, signal transduction, pH balance, and cellular structure—developing advanced protein sequencing technologies is critical. Proteins are fundamental to nearly all biological activities, making their detailed study essential for understanding cellular functions and disease mechanisms. The Edman degradation method, developed in the 1950s, was a breakthrough in sequencing short peptides. However, its limitations in read length (fewer than 50 amino acids) and slow cycle time fall short of modern demands. Mass spectrometry has since emerged as the gold standard in protein sequencing due to its high accuracy, throughput, and reproducibility. The method is enhanced by a robust sample preparation workflow and advances in mass spectrometry technology. Despite these strengths, mass spectrometry faces limitations in dynamic range, sensitivity, read length, and sequence coverage, hindering complete de novo protein sequencing. These technological gaps underscore the need for innovative methods to provide more detailed and accurate protein sequence data. In the past decade, new protein sequencing methods, including tunneling current, fluorescence fingerprinting, and real-time dynamic fluorescence, have shown significant developmental potential. However, these methods are not yet ready for widespread application, as each still faces technical hurdles. Meanwhile, advances in nanopore DNA sequencing have sparked interest in applying nanopore technology to protein sequencing, particularly owing to its speed, convenience, and cost-effectiveness. Unlike DNA sequencing, protein sequencing presents greater challenges due to proteins’ complex three-dimensional structures, heterogeneous electrical charges, difficulties in directional movement, and diverse amino acid compositions, further complicated by post-translational modifications. Researchers have made significant strides in addressing these challenges, such as using unfolding enzymes, high temperatures, high voltage, and deformers to unravel protein structures, and employing charged sequences and electroosmotic flow to control peptide translocation. The latest strategies for nanopore protein sequencing can be broadly categorized into three approaches: strand sequencing, enzyme-assisted nanopore sequencing, and nanopore fingerprinting. In strand sequencing, dragging a protein-oligonucleotide conjugate through a nanopore with the aid of protein motors generates stepped current signals produced by the peptide strand. In enzyme-assisted nanopore sequencing, 20 proteinogenic amino acids and various post-translational modifications have been distinguished using nanopores, and sequencing of short peptides has also been demonstrated. In nanopore fingerprinting, polypeptide fragments resulting from protease digestion of a protein can be identified through nanopore sensing. Despite these advances, further improvements in protein engineering, data processing, identification accuracy, and read length are needed to make these strategies practically useful. This review provides an overview of the current major approaches to nanopore protein sequencing, emphasizing the strategies, recent advances, breakthroughs and challenges in nanopore protein sequencing. As nanopore technology continues to evolve, it is expected to offer more efficient and accurate sequencing solutions in proteomics, potentially leading to new technological breakthroughs in biochemistry and biomedicine.
5.Research progress of fluorescent probes in uric acid detection
Di-Di XING ; Ruo-Jin LIU ; Jia-Yu QI ; Ning MA ; Ya-Kun JI ; Jia-Xin ZHOU ; Yu-Shan XING ; Xiao-Lan ZHEN
Chinese Medical Equipment Journal 2024;45(6):93-104
The advantages of fluorescence detection of uric acid were introduced compared to the traditional detection methods.The preparation process,detection principle and performance of organic,inorganic and organic-inorganic hybrid fluorescent probes were reviewed.The advantages and disadvantages of kinds of fluorescent probes were analyzed when used for uric acid detection,and the futural directions were pointed out for related research.[Chinese Medical Equipment Journal,2024,45(6):93-104]
6.A multicenter study of neonatal stroke in Shenzhen,China
Li-Xiu SHI ; Jin-Xing FENG ; Yan-Fang WEI ; Xin-Ru LU ; Yu-Xi ZHANG ; Lin-Ying YANG ; Sheng-Nan HE ; Pei-Juan CHEN ; Jing HAN ; Cheng CHEN ; Hui-Ying TU ; Zhang-Bin YU ; Jin-Jie HUANG ; Shu-Juan ZENG ; Wan-Ling CHEN ; Ying LIU ; Yan-Ping GUO ; Jiao-Yu MAO ; Xiao-Dong LI ; Qian-Shen ZHANG ; Zhi-Li XIE ; Mei-Ying HUANG ; Kun-Shan YAN ; Er-Ya YING ; Jun CHEN ; Yan-Rong WANG ; Ya-Ping LIU ; Bo SONG ; Hua-Yan LIU ; Xiao-Dong XIAO ; Hong TANG ; Yu-Na WANG ; Yin-Sha CAI ; Qi LONG ; Han-Qiang XU ; Hui-Zhan WANG ; Qian SUN ; Fang HAN ; Rui-Biao ZHANG ; Chuan-Zhong YANG ; Lei DOU ; Hui-Ju SHI ; Rui WANG ; Ping JIANG ; Shenzhen Neonatal Data Network
Chinese Journal of Contemporary Pediatrics 2024;26(5):450-455
Objective To investigate the incidence rate,clinical characteristics,and prognosis of neonatal stroke in Shenzhen,China.Methods Led by Shenzhen Children's Hospital,the Shenzhen Neonatal Data Collaboration Network organized 21 institutions to collect 36 cases of neonatal stroke from January 2020 to December 2022.The incidence,clinical characteristics,treatment,and prognosis of neonatal stroke in Shenzhen were analyzed.Results The incidence rate of neonatal stroke in 21 hospitals from 2020 to 2022 was 1/15 137,1/6 060,and 1/7 704,respectively.Ischemic stroke accounted for 75%(27/36);boys accounted for 64%(23/36).Among the 36 neonates,31(86%)had disease onset within 3 days after birth,and 19(53%)had convulsion as the initial presentation.Cerebral MRI showed that 22 neonates(61%)had left cerebral infarction and 13(36%)had basal ganglia infarction.Magnetic resonance angiography was performed for 12 neonates,among whom 9(75%)had involvement of the middle cerebral artery.Electroencephalography was performed for 29 neonates,with sharp waves in 21 neonates(72%)and seizures in 10 neonates(34%).Symptomatic/supportive treatment varied across different hospitals.Neonatal Behavioral Neurological Assessment was performed for 12 neonates(33%,12/36),with a mean score of(32±4)points.The prognosis of 27 neonates was followed up to around 12 months of age,with 44%(12/27)of the neonates having a good prognosis.Conclusions Ischemic stroke is the main type of neonatal stroke,often with convulsions as the initial presentation,involvement of the middle cerebral artery,sharp waves on electroencephalography,and a relatively low neurodevelopment score.Symptomatic/supportive treatment is the main treatment method,and some neonates tend to have a poor prognosis.
7.Design of intelligent positioning system for mobile medical equipment in operating room based on Bluetooth technology
Zhi-Meng LIU ; Ya-Dong LYU ; Long-Xue QIAO ; Lin-Huai TIAN ; Kun YANG ; Kai-Yuan LI ; Ning-Bo ZHAN ; Ying-Kang WEI ; Yong CHAO
Chinese Medical Equipment Journal 2023;44(9):29-32
Objective To develop an intelligent positioning system for mobile medical equipment in the operating room based on Bluetooth technology to enhance medical equipment management efficiency.Methods The intelligent positioning system for mobile medical equipment used received signal strength indication(RSSI)algorithm and multi-gateway trajectory filtering algorithm to realize Bluetooth positioning,which was composed of Bluetooth gateways,Bluetooth beacons,Bluetooth labels and a background data processing platform.The Bluetooth gateway consisted of an active power over ethernet(POE)module,a DC power module,a CPU,a Wi-Fi module and a Bluetooth module;the Bluetooth beacon included a beacon control unit,a Bluetooth transmitter module and a Bluetooth receiver module;the Bluetooth label was made up of a microcontroller unit(MCU),a Bluetooth module,an anti-temper switch and a accelerometer;the data processing platform had the front end developed with Vue architecture and the back end with Java language.Results The system developed could accurately locate the medical equipment in the operating room without electromagnetic interference to other medical devices.Conclusion The system developed gains advantages in high positioning accuracy,low electromagnetic interference,high stability and reliability and low cost,which improves the positioning and management efficiency of medical equipment under the premise of ensuring safety.[Chinese Medical Equipment Journal,2023,44(9):29-32]
8.Classified reduction based on CT two-dimensional images for the surgical treatment of single segment facet joint dislocation in subaxial cervical spine
Yongsheng KANG ; Wei MEI ; Qingde WANG ; Rundong GUO ; Peilin LIU ; Wentao JIANG ; Zhenhui ZHANG ; Kai SU ; Zhe SHAO ; Ya SONG ; Kun WANG
Chinese Journal of Trauma 2023;39(4):331-340
Objective:To investigate the efficacy of the classified reduction based on CT two-dimensional images for the surgical treatment of single segment facet joint dislocation in subaxial cervical spine.Methods:A retrospective case series study was made on 105 patients with single segment facet joint dislocation in subaxial cervical spine admitted to Zhengzhou Orthopedic Hospital from January 2015 to October 2022. There were 63 males and 42 females, with the age range of 22-78 years [(47.5±3.6)years]. Preoperative American Spinal Cord Injury Association (ASIA) classification was grade A in 23 patients, grade B in 45, grade C in 22, grade D in 15 and grade E in 0. The classification of surgical approach was based on the presence or not of continuity between anterior and posterior subaxial cervical structures and the movability of the posterior cervical facet joint on CT two-dimensional images, including anterior cervical surgery if both were presented and posterior facet joint resection plus anterior cervical surgery if there was discontinuity between anterior and posterior subaxial cervical structures or posterior facet joint fusion. Reduction procedures were applied in accordance with the type of facet joint dislocation classified based on the position of the lower upper corner of facet joint, including skull traction or manipulative reduction for the dislocation locating at the dorsal side (type A), intraoperative skull traction and leverage technique for the dislocation locating at the top (type B) and intraoperative skull traction and leverage technique with boosting for the dislocation locating at the ventral side (type C). If the dislocation of two facet joints in the same patient was different, the priority of management followed the order of type C, type B and type A. The reduction success rate, operation time and intraoperative blood loss were recorded. The cervical physiological curvature was evaluated by comparing the intervertebral space height and Cobb angle before operation, at 3 months after operation and at the last follow-up. The fusion rate of intervertebral bone grafting was evaluated by Lenke grading at 3 months after operation. The spinal cord nerve injury was assessed with ASIA classification before operation and at 3 months after operation. Japanese Orthopedic Association (JOA) score was applied to measure the degree of cervical spinal cord dysfunction before operation and at 3 months after operation, and the final follow-up score was used to calculate the rate of spinal cord functional recovery. The occurrence of complications was observed.Results:All patients were followed up for 3-9 months [(6.0±2.5)months]. The reduction success rate was 100%. The operation time was 40-95 minutes [(58.6±9.3)minutes]. The intraoperative blood loss was 40 to 120 ml [(55.7±6.8)ml]. The intervertebral space height was (4.7±0.3)mm and (4.7±0.2)mm at 3 months after operation and at the last follow-up, significantly decreased from preoperative (3.1±0.5)mm (all P<0.01), but there was no significant difference in intervertebral space height at 3 months after operation and at the last follow-up ( P>0.05). The Cobb angle was (6.5±1.3)° and (6.3±1.2)° at 3 months after operation and at the last follow-up, significantly increased from preoperative (-5.4±2.2)° (all P<0.01), but there was no significant difference in Cobb angle at 3 months after operation and at the last follow-up ( P>0.05). The fusion rate of intervertebral bone grafting evaluated by Lenke grading was 100% at 3 months after operation. The ASIA grading was grade A in 15 patients, grade B in 42, grade C in 29, grade D in 12 and grade E in 7 at 3 months after operation. The patients showed varying degrees of improvement in postoperative ASIA grade except that 15 patients with preoperative ASIA grade A had partial recovery of limb sensation but no improvement in ASIA grade. The JOA score was (13.3±0.6)points and (13.1±0.6)points at 3 months after operation and at the last follow-up, significantly improved from preoperative (6.8±1.4)points (all P<0.01), but there was no significant difference in JOA score at 3 months after operation and at the last follow-up ( P>0.05). The rate of spinal cord functional recovery was (66.3±2.5)% at the last follow-up. All patients had no complications such as increased nerve damage or vascular damage. Conclusion:The classified reduction based on CT two-dimensional images for the surgical treatment of single segment facet joint dislocation in subaxial cervical spine has advantages of reduced facet joint dislocation, recovered intervertebral space height and physiological curvature, good intervertebral fusion and improved spinal cord function.
9.Ginsenoside Rg1 injection combined with inosine tablets and vitamin B1 for the treatment of primary retinitis pigmentosa
Mei BAI ; De-Yu MIAO ; Ya-Kun LI ; Jian-Dong LYU ; Zhi-Qiang LIU ; Ya-Li LI ; Xiang-Dong GUO
International Eye Science 2023;23(12):2035-2039
AIM: To investigate the effects of ginsenoside Rg1 injection combined with inosine tablets and vitamin B1 on serum brain-derived neurotrophic factor(BDNF), pituitary adenylate cyclase activating polypeptide(PACAP)and clinical efficacy in primary retinitis pigmentosa.METHODS: A total of 50 patients(100 eyes)with primary retinitis pigmentosa who admitted to the Department of Ophthalmology, the Second Affiliated Hospital of Hebei North University from August 2019 to March 2022 were selected as the research object. They were divided into the study group and the control group according to random number table, with 50 eyes in each group. Patients in the control group were treated with inosine tablets and vitamin B1, while patients in the study group were treated with ginsenoside Rg1 injection on the basis of the control group. The expression of BDNF and PACAP in serum, electroretinogram and spectral-domain optical coherence tomography(SD-OCT)were compared before and after treatment, and the retinal thickness(RT), mean deviation(MD), clinical efficacy and safety indexes were compared between the two groups.RESULTS: There were no differences in the MD of the two groups before treatment(t=1.670, P=0.098), while the MD of the study group was significantly lower than that of the control group after treatment(t=3.628, P<0.01). Before treatment, RT with a diameter of 1mm at the circle of macular fovea was compared between the two groups(t=0.108, P=0.914), it was significantly higher than that in the control group after treatment(t=6.125, P<0.01). Before treatment, there was no significant difference in the results of dark adaptation of electroretinogram between the two groups(all P>0.05). After treatment, the results of dark adaptation in the study group were significantly better than those in the control group(all P<0.01). Before treatment, there was no significant difference in the results of electroretinogram adaptation between the two groups(all P>0.05). After treatment, the results of electroretinogram adaptation in the study group were significantly better than those in the control group(all P<0.01). There was no significant difference in BDNF and PACAP between the two groups before treatment(all P>0.05). BDNF and PACAP in the study group were higher than those of the control group after treatment(all P<0.01). After treatment, no adverse reactions were observed in both groups.CONCLUSION: The treatment of patients with primary retinitis pigmentosa with ginsenoside will improve the retinal function and promote the prognosis of the disease by regulating the expression of BDNF and PACAP, and it is highly safe.
10.Analysis on missed diagnosis or misdiagnosis of anomalous origin of left coronary artery from pulmonary artery by echocardiography from one single medical center.
Shan LIN ; Lin HE ; Li JI ; Yuan PENG ; Kun LIU ; Qing LYU ; Jing WANG ; Yu Man LI ; Li ZHANG ; Ming Xing XIE ; Ya Li YANG
Chinese Journal of Cardiology 2023;51(5):481-489
Objectives: To analyze the reasons of missed diagnosis or misdiagnosis on anomalous origin of left coronary artery from pulmonary artery (ALCAPA) by echocardiography. Methods: This is a retrospective study. Patients with ALCAPA who underwent surgical treatment in Union Hospital, Tongji Medical College, Huazhong University of Science and Technology from August 2008 to December 2021 were included. According to the results of preoperative echocardiography and surgical diagnosis, the patients were divided into confirmed group or missed diagnosis/misdiagnosis group. The results of preoperative echocardiography were collected, and the specific echocardiographic signs were analyzed. According to the experience of the doctors, the echocardiographic signs were divided into four types, namely clear displayed, vague/doubtful displayed, no display and no notice, and the display rate of each sign was calculated (display rate=number of clearly displayed cases/total number of cases×100%). By referring the surgical data, we analyzed and recorded the pathological anatomy and pathophysiological characteristics of the patients, and the rate of missed diagnosis/misdiagnosis of echocardiography in patients with different characteristics was compared. Results: A total of 21 patients were enrolled, including 11 males, aged 1.8 (0.8, 12.3) years (range 1 month to 47 years). Except for one patient with anomalous origin of left anterior descending artery, the others were all originated from the main left coronary artery (LCA). There were 13 cases of ALCAPA in infant and children, and 8 cases of adult ALCAPA. There were 15 cases in the confirmed group (diagnostic accuracy was 71.4% (15/21)), and 6 cases in the missed diagnosis/misdiagnosis group (three cases were misdiagnosed as primary endocardial fibroelastosis, two cases were misdiagnosed as coronary-pulmonary artery fistula; and one case was missed diagnosis). The working years of the physicians in the confirmed group were longer than those in the missed diagnosis/misdiagnosed group ((12.8±5.6) years vs. (8.3±4.7) years, P=0.045). In infants with ALCAPA, the detection rate of LCA-pulmonary shunt (8/10 vs. 0, P=0.035) and coronary collateral circulation (7/10 vs. 0, P=0.042) in confirmed group was higher than that in missed diagnosis/misdiagnosed group. In adult ALCAPA patients, the detection rate of LCA-pulmonary artery shunt was higher in confirmed group than that in missed diagnosis/misdiagnosed group (4/5 vs. 0, P=0.021). The missed diagnosis/misdiagnosis rate of adult type was higher than that of infant type (3/8 vs. 3/13, P=0.410). The rate of missed diagnosis/misdiagnosis was higher in patients with abnormal origin of branches than that of abnormal origin of main trunk (1/1 vs. 5/21, P=0.028). The rate of missed diagnosis/misdiagnosis in patients with LCA running between the main and pulmonary arteries was higher than that distant from the main pulmonary artery septum (4/7 vs. 2/14, P=0.064). The rate of missed diagnosis/misdiagnosis in patients with severe pulmonary hypertension was higher than that in patients without severe pulmonary hypertension (2/3 vs. 4/18, P=0.184). The reasons with an echocardiography missed diagnosis/misdiagnosis rate of≥50% included that (1) the proximal segment of LCA ran between the main and pulmonary arteries; (2) abnormal opening of LCA at the right posterior part of the pulmonary artery; (3) abnormal origin of LCA branches; (4) complicated with severe pulmonary hypertension. Conclusions: Echocardiography physicians' knowledge of ALCAPA and diagnostic vigilance are critical to the accuracy of diagnosis. Attention should be paid to the pediatric cases with no obvious precipitating factors of left ventricular enlargement, regardless of whether the left ventricular function is normal or not, the origin of coronary artery should be routinely explored.
Male
;
Adult
;
Infant
;
Child
;
Humans
;
Bland White Garland Syndrome/diagnostic imaging*
;
Pulmonary Artery/diagnostic imaging*
;
Retrospective Studies
;
Missed Diagnosis
;
Hypertension, Pulmonary
;
Echocardiography
;
Coronary Vessel Anomalies/diagnostic imaging*

Result Analysis
Print
Save
E-mail