1.Predicting Hepatocellular Carcinoma Using Brightness Change Curves Derived From Contrast-enhanced Ultrasound Images
Ying-Ying CHEN ; Shang-Lin JIANG ; Liang-Hui HUANG ; Ya-Guang ZENG ; Xue-Hua WANG ; Wei ZHENG
Progress in Biochemistry and Biophysics 2025;52(8):2163-2172
ObjectivePrimary liver cancer, predominantly hepatocellular carcinoma (HCC), is a significant global health issue, ranking as the sixth most diagnosed cancer and the third leading cause of cancer-related mortality. Accurate and early diagnosis of HCC is crucial for effective treatment, as HCC and non-HCC malignancies like intrahepatic cholangiocarcinoma (ICC) exhibit different prognoses and treatment responses. Traditional diagnostic methods, including liver biopsy and contrast-enhanced ultrasound (CEUS), face limitations in applicability and objectivity. The primary objective of this study was to develop an advanced, light-weighted classification network capable of distinguishing HCC from other non-HCC malignancies by leveraging the automatic analysis of brightness changes in CEUS images. The ultimate goal was to create a user-friendly and cost-efficient computer-aided diagnostic tool that could assist radiologists in making more accurate and efficient clinical decisions. MethodsThis retrospective study encompassed a total of 161 patients, comprising 131 diagnosed with HCC and 30 with non-HCC malignancies. To achieve accurate tumor detection, the YOLOX network was employed to identify the region of interest (ROI) on both B-mode ultrasound and CEUS images. A custom-developed algorithm was then utilized to extract brightness change curves from the tumor and adjacent liver parenchyma regions within the CEUS images. These curves provided critical data for the subsequent analysis and classification process. To analyze the extracted brightness change curves and classify the malignancies, we developed and compared several models. These included one-dimensional convolutional neural networks (1D-ResNet, 1D-ConvNeXt, and 1D-CNN), as well as traditional machine-learning methods such as support vector machine (SVM), ensemble learning (EL), k-nearest neighbor (KNN), and decision tree (DT). The diagnostic performance of each method in distinguishing HCC from non-HCC malignancies was rigorously evaluated using four key metrics: area under the receiver operating characteristic (AUC), accuracy (ACC), sensitivity (SE), and specificity (SP). ResultsThe evaluation of the machine-learning methods revealed AUC values of 0.70 for SVM, 0.56 for ensemble learning, 0.63 for KNN, and 0.72 for the decision tree. These results indicated moderate to fair performance in classifying the malignancies based on the brightness change curves. In contrast, the deep learning models demonstrated significantly higher AUCs, with 1D-ResNet achieving an AUC of 0.72, 1D-ConvNeXt reaching 0.82, and 1D-CNN obtaining the highest AUC of 0.84. Moreover, under the five-fold cross-validation scheme, the 1D-CNN model outperformed other models in both accuracy and specificity. Specifically, it achieved accuracy improvements of 3.8% to 10.0% and specificity enhancements of 6.6% to 43.3% over competing approaches. The superior performance of the 1D-CNN model highlighted its potential as a powerful tool for accurate classification. ConclusionThe 1D-CNN model proved to be the most effective in differentiating HCC from non-HCC malignancies, surpassing both traditional machine-learning methods and other deep learning models. This study successfully developed a user-friendly and cost-efficient computer-aided diagnostic solution that would significantly enhances radiologists’ diagnostic capabilities. By improving the accuracy and efficiency of clinical decision-making, this tool has the potential to positively impact patient care and outcomes. Future work may focus on further refining the model and exploring its integration with multimodal ultrasound data to maximize its accuracy and applicability.
2.Study on the potential allergen and mechanism of pseudo-allergic reactions induced by combined using of Reduning injection and penicillin G injection based on metabolomics and bioinformatics
Yu-long CHEN ; You ZHAI ; Xiao-yan WANG ; Wei-xia LI ; Hui ZHANG ; Ya-li WU ; Liu-qing YANG ; Xiao-fei CHEN ; Shu-qi ZHANG ; Lu NIU ; Ke-ran FENG ; Kun LI ; Jin-fa TANG ; Ming-liang ZHANG
Acta Pharmaceutica Sinica 2024;59(2):382-394
Based on the strategy of metabolomics combined with bioinformatics, this study analyzed the potential allergens and mechanism of pseudo-allergic reactions (PARs) induced by the combined use of Reduning injection and penicillin G injection. All animal experiments and welfare are in accordance with the requirements of the First Affiliated Experimental Animal Ethics and Animal Welfare Committee of Henan University of Chinese Medicine (approval number: YFYDW2020002). Based on UPLC-Q-TOF/MS technology combined with UNIFI software, a total of 21 compounds were identified in Reduning and penicillin G mixed injection. Based on molecular docking technology, 10 potential allergens with strong binding activity to MrgprX2 agonist sites were further screened. Metabolomics analysis using UPLC-Q-TOF/MS technology revealed that 34 differential metabolites such as arachidonic acid, phosphatidylcholine, phosphatidylserine, prostaglandins, and leukotrienes were endogenous differential metabolites of PARs caused by combined use of Reduning injection and penicillin G injection. Through the analysis of the "potential allergen-target-endogenous differential metabolite" interaction network, the chlorogenic acids (such as chlorogenic acid, neochlorogenic acid, cryptochlorogenic acid, and isochlorogenic acid A) and
3.The Functional Role of SUMOylation in The Tumor Microenvironment
Pan-Pan ZHAO ; Jun-Xu YU ; Ya-Ning CHE ; Hui-Yi LIANG ; Chao HUANG
Progress in Biochemistry and Biophysics 2024;51(6):1256-1268
Tumors continue to be a major challenge in human survival that we have yet to overcome. Despite the variety of treatment options available, we have not yet found an effective method. As more and more research is conducted, attention has been turned to a new field for tumor treatment—the tumor microenvironment (TME). This is a dynamic and complex environment consisting of various matrix cells surrounding cancer cells, including surrounding immune cells, blood vessels, extracellular matrix, fibroblasts, bone marrow-derived inflammatory cells, signaling molecules, and some specific cell types. Firstly, endothelial cells play a key role in tumor development and the immune system’s protection of tumor cells. Secondly, immune cells, such as macrophages, Treg cells, Th17 cells, are widely involved in various immune responses and activities in the human body, such as inflammation responses promoting survival carefully orchestrated by the tumor. Even though many studies have extensively researched the TME and found many research schemes, so far, no key effective method has been found to treat tumors by affecting the TME. The TME is a key interaction area between the host immune system and the tumor. Cells within the TME influence each other and interact with cancer cells to affect cancer cell invasion, tumor growth, and metastasis. This is a new direction for cancer treatment. In the complex environment of the TME, post-translational modifications (PTMs) of proteins have been proven to play an important role in the TME. PTMs are dynamic, strictly regulated changes to proteins that control their function by regulating their structure, spatial location, and interaction. Among PTMs, a reversible post-translational modification called SUMOylation is a common regulatory mechanism in cellular processes. It is a post-translational modification that targets lysine residues with a small ubiquitin-like modifier (SUMO) in a reversible post-translational modification manner. SUMOylation is widely involved in carcinogenesis, DNA damage response, cancer cell proliferation, metastasis, and apoptosis, playing a pivotal role in the TME, such as DNA damage repair, tumor metastasis, and also participates in immune cell differentiation, activation, and inhibition of immune cells. On the other hand, SUMO or sentrin-specific protease (SENP) inhibitors can interfere with the SUMOylation process, thereby affecting many biological processes, including immune response, carcinogenesis, cell cycle progression, and cell apoptosis, etc. In summary, this review aims to introduce the dynamic modification of protein SUMOylation on various immune cells and the application of various inhibitors, thereby exploring its role in the TME. This is a challenging but hopeful field, and we look forward to future research that can bring more breakthroughs. In conclusion, the TME is a complex and dynamic environment that plays a crucial role in the development and progression of tumors. Understanding the intricate interactions within the TME and the role of PTMs, particularly SUMOylation, could provide valuable insights into the mechanisms of tumor development and potentially lead to the development of novel therapeutic strategies. The study of SUMOylation and its effects on various immune cells in the TME is an exciting and promising area of research that could significantly advance our understanding of tumor biology and potentially lead to the development of more effective treatments for cancer. This is a challenging but hopeful field, and we look forward to future research that can bring more breakthroughs.
4.Study on the effect of different administration regimens of iprrazole enteric-coated tablets on inhibiting gastric acid secretion
Ting-Yuan PANG ; Zhi WANG ; Zi-Shu HU ; Zi-Han SHEN ; Yue-Qi WANG ; Ya-Qian CHEN ; Xue-Bing QIAN ; Jin-Ying LIANG ; Liang-Ying YI ; Jun-Long LI ; Zhi-Hui HAN ; Guo-Ping ZHONG ; Guo-Hua CHENG ; Hai-Tang HU
The Chinese Journal of Clinical Pharmacology 2024;40(1):92-96
Objective To compare the effects of 20 mg qd and 10 mg bidadministration of iprrazole enteric-coated tablets on the control of gastric acid in healthy subjects.Methods A randomized,single-center,parallel controlled trial was designed to include 8 healthy subjects.Randomly divided into 2 groups,20 mg qd administration group:20 mg enteric-coated tablets of iprrazole in the morning;10 mg bid administration group:10 mg enteric-coated tablets of iprrazole in the morning and 10 mg in the evening.The pH values in the stomach of the subjects before and 24 h after administration were monitored by pH meter.The plasma concentration of iprazole after administration was determined by HPLC-MS/MS.The main pharmacokinetic parameters were calculated by Phoenix WinNonlin(V8.0)software.Results The PK parameters of iprrazole enteric-coated tablets and reference preparations in fasting group were as follows:The Cmax of 20 mg qd group and 10 mg bid group were(595.75±131.15)and(283.50±96.98)ng·mL-1;AUC0-t were(5 531.94±784.35)and(4 686.67±898.23)h·ng·mL-1;AUC0-∞ were(6 003.19±538.59)and(7 361.48±1 816.77)h·ng·mL-1,respectively.The mean time percentage of gastric pH>3 after 20 mg qd and 10 mg bid were 82.64%and 61.92%,and the median gastric pH within 24 h were 6.25±1.49 and 3.53±2.05,respectively.The mean gastric pH values within 24 h were 5.71±1.36 and 4.23±1.45,respectively.The correlation analysis of pharmacokinetic/pharmacodynamics showed that there was no significant correlation between the peak concentration of drug in plasma and the inhibitory effect of acid.Conclusion Compared with the 20 mg qd group and the 10 mg bid group,the acid inhibition effect is better,the administration times are less,and the safety of the two administration regimes is good.
5.Development of a High-throughput Sequencing Platform for Detection of Viral Encephalitis Pathogens Based on Amplicon Sequencing
Li Ya ZHANG ; Zhe Wen SU ; Chen Rui WANG ; Yan LI ; Feng Jun ZHANG ; Hui Sheng LIU ; He Dan HU ; Xiao Chong XU ; Yu Jia YIN ; Kai Qi YIN ; Ying HE ; Fan LI ; Hong Shi FU ; Kai NIE ; Dong Guo LIANG ; Yong TAO ; Tao Song XU ; Feng Chao MA ; Yu Huan WANG
Biomedical and Environmental Sciences 2024;37(3):294-302
Objective Viral encephalitis is an infectious disease severely affecting human health.It is caused by a wide variety of viral pathogens,including herpes viruses,flaviviruses,enteroviruses,and other viruses.The laboratory diagnosis of viral encephalitis is a worldwide challenge.Recently,high-throughput sequencing technology has provided new tools for diagnosing central nervous system infections.Thus,In this study,we established a multipathogen detection platform for viral encephalitis based on amplicon sequencing. Methods We designed nine pairs of specific polymerase chain reaction(PCR)primers for the 12 viruses by reviewing the relevant literature.The detection ability of the primers was verified by software simulation and the detection of known positive samples.Amplicon sequencing was used to validate the samples,and consistency was compared with Sanger sequencing. Results The results showed that the target sequences of various pathogens were obtained at a coverage depth level greater than 20×,and the sequence lengths were consistent with the sizes of the predicted amplicons.The sequences were verified using the National Center for Biotechnology Information BLAST,and all results were consistent with the results of Sanger sequencing. Conclusion Amplicon-based high-throughput sequencing technology is feasible as a supplementary method for the pathogenic detection of viral encephalitis.It is also a useful tool for the high-volume screening of clinical samples.
6.Establishment and evaluation methods of a novel animal model of liver depression transforming into fire syndrome-related depression
Dan SU ; Jian LI ; Gen-hua ZHU ; Ming YANG ; Liang-liang LIAO ; Zhi-fu AI ; Hui-zhen LI ; Ya-li LIU ; Yong-gui SONG
Acta Pharmaceutica Sinica 2024;59(6):1680-1690
Through a compound induction method, combined with neurobehavioral, macroscopic characterization and objective pathological evaluation indicators, a murine depression model of liver depression transforming into fire syndrome was constructed and confirmed. The model was constructed using a combination of sleep deprivation, light exposure, and alternate-day food deprivation. Evaluation was conducted at three levels: face validity, constructs validity, and predictive validity. The establishment of the liver depression transforming into fire syndrome depression model was further validated through the counterproof of traditional Chinese medicine formulas. In terms of face validity, compared to the control group, mice in the model group exhibited typical depressive symptoms in neurobehavioral assessments; the general observation of the model group mice reveals disheveled and lackluster fur, along with delayed and easily agitated responses. Additionally, there is a substantial increase in water consumption. In the sleep phase detection of mouse, the model group showed a significant increase in the proportion of time spent in the wake phase during sleep, accompanied by a significant decrease in the proportions of time spent in both non-rapid eye movement (NREM) and rapid eye movement (REM) sleep phases. There are significant differences in physiological indicators such as average blood flow velocity, blood flow rate, tongue, urine, and claw color (r values) in the internal carotid artery. Structural validity demonstrated that levels of 5-hydroxytryptamine (5-HT), dopamine (DA), and
7.Synthesis and activity evaluation of 6-azazindole derivatives for pancreatic cancer therapy
Yang CAO ; Qian LI ; Ya-ling WANG ; Wen-hui CUI ; Chen-liang QIAN ; Xin-xin SI
Acta Pharmaceutica Sinica 2024;59(10):2828-2835
Fragment with some anti-pancreatic cancer activity was identified by screening our internal chemical library. Eighteen compounds in 4 classes were synthesized by systematic modification and their anti-pancreatic cancer activity were evaluated. Ⅱ-1 (IC50 = 6.40 ± 0.34 μmol·L-1) and Ⅱ-2 (IC50 = 7.15 ± 0.51 μmol·L-1) exhibited outstanding activity. Subsequently, the anti-migration ability and invasion ability of Ⅱ-1 was evaluated by wound healing assay and invasion assay, Ⅱ-1 exhibited good anti-migration ability and outstanding anti-invasion ability. Using molecular docking technology and molecular dynamics simulation technology, the potential target was locked on bispecific tyrosine phosphorylation regulates kinase 1A (DYRK1A). By enzyme activity testing, the inhibitory capacity of Ⅱ-1 and Ⅱ-2 was 48% and 32%, respectively.
8.Exploring the risk "time interval window" of sequential medication of Reduning injection and penicillin G injection based on the correlation between biochemical indexes and metabolomics characteristics
Ming-liang ZHANG ; Yu-long CHEN ; Xiao-yan WANG ; Xiao-fei CHEN ; Hui ZHANG ; Ya-li WU ; Liu-qing YANG ; Shu-qi ZHANG ; Lu NIU ; Ke-ran FENG ; Wei-xia LI ; Jin-fa TANG
Acta Pharmaceutica Sinica 2024;59(7):2098-2107
Exploring the risk "time interval window" of sequential medication of Reduning injection (RDN) and penicillin G injection (PG) by detecting the correlation between serum biochemical indexes and plasma metabonomic characteristics, in order to reduce the risk of adverse reactions caused by the combination of RDN and PG. All animal experiments and welfare are in accordance with the requirements of the First Affiliated Experimental Animal Ethics and Animal Welfare Committee of Henan University of Chinese Medicine (approval number: YFYDW2020002). The changes of biochemical indexes in serum of rats were detected by enzyme-linked immunosorbent assay. It was determined that RDN combined with PG could cause pseudo-allergic reactions (PARs) activated by complement pathway. Further investigation was carried out at different time intervals (1.5, 2, 3.5, 4, 6, and 8 h PG+RDN). It was found that sequential administration within 3.5 h could cause significant PARs. However, PARs were significantly reduced after administration interval of more than 4 h. LC-MS was used for plasma metabolomics analysis, and the levels of serum biochemical indicators and plasma metabolic profile characteristics were compared in parallel. 22 differential metabolites showed similar or opposite trends to biochemical indicators before and after 3.5 h. And enriched to 10 PARs-related pathways such as arachidonic acid metabolism, steroid hormone biosynthesis, linoleic acid metabolism, glycerophospholipid metabolism, and tryptophan metabolism. In conclusion, there is a risk "time interval window" phenomenon in the adverse drug reactions caused by the sequential use of RDN and PG, and the interval medication after the "time interval window" can significantly reduce the risk of adverse reactions.
9.Exploring the association between community health follow-up management and quality of life among disabled residents,based on long-term care insurance
Hui LI ; Li-Juan WANG ; Liang JIN ; Jun-Ling GAO ; Ya-Ping ZHANG
Fudan University Journal of Medical Sciences 2024;51(3):344-351
Objective To explore the relationship between community health follow-up management and the quality of life of residents receiving home care from long-term care insurance(LTCI),and provide a basis for the construction of an integrated community home care service model centered on disabled residents.Methods According to the inclusion and exclusion criteria,and the principle of convenience,a sample was selected consisting of residents who participated in LTCI home care from Jan 1 to Dec 31,2021,in Meilong Community of Minhang District,Shanghai.After a year of participation,the subjects'quality of life was assessed face-to-face by trained community doctors using the 36-item short form health survey(SF-36).Based on the electronic health records of residents,the community chronic disease management system,the LTCI management system,and combined with on-site questionnaire survey,community doctors collected the demographic information,lifestyle,types of diseases,chronic disease comorbidity status,and health follow-up management provided by primary medical and health institutions.To assess the association between community health follow-up management and residents'quality of life with home care insurance for elderly care through cross-sectional analysis.Results The survey revealed that 230(57.64%)individuals had indeed received health follow-up management provided by the community health service center.The scores of the general health,physiological function,physical pain,mental health,vitality,and emotional function dimensions on the SF-36 scale were found to be higher compared to those of no follow-up population.The difference between the two groups exhibited statistical significance(all P<0.05).Furthermore,individuals who actively engaged in the health follow-up management provided by community health service centers exhibited significantly higher scores in terms of health change(P=0.003),indicating a relatively favorable overall health status.After adjusting for demographic and confounding variables,further analysis revealed a significant positive association between health follow-up management provided by community health service centers and the overall health,physiological function,physical pain,mental health,and vitality dimensions of the SF-36 scale among LTCI beneficiaries(all P<0.05).Conclusion The provision of health follow-up management by community health service centers exerts a significant positive impact on the quality of life among disabled residents covered by LTCI.It is an effective way to improve the quality of LTCI home care services.
10.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve

Result Analysis
Print
Save
E-mail