1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.E2E testing of Cyberknife lung tracking using a homemade lung phantom
Xiao WEI ; Xiangjie MA ; Mingsheng LI ; Zhengzhao ZHANG ; Ya LIU ; Yuze YANG ; Jinsheng CHENG
Chinese Journal of Radiological Health 2024;33(1):1-6
Objective :
To verify the feasibility of using a homemade lung phantom for quality control of Cyberknife by
comparing the measurement results of the homemade lung phantom and CIRS dynamic phantom in E2E testing of Cyberknife lung tracking.
Methods :
The patient treatment process was simulated, including CT positioning, plan design, irra-
diation implementation, film scanning, and analysis using the homemade phantom and CIRS phantom. The two phantoms
were measured five times using MLC under the S7 generation Cyberknife and five times using Iris under the M6 generation
Cyberknife. The differences in measurement results between the two phantoms were analyzed using independent sample t-test.
Results :
For the S7 generation Cyberknife, the statistical analysis of differences between the two phantoms in the detection values on the X-axis, Y-axis, Z-axis, and total deviation showed P values of 0.236, 0.175, 0.289, and 0.668, respect-
ively. For the M6 generation Cyberknife, the statistical analysis showed P values of 0.880, 0.891, 0.573, and 0.433, respect-
ively. The P values were all > 0.05. Therefore, there were no statistically significant differences in the detection results
between the homemade lung phantom and the CIRS phantom under the S7 and M6 generation Cyberknife. The total deviation values were <1.5 mm.
Conclusion
The homemade lung phantom and CIRS phantom have consistent measurement
results in the E2E testing of Cyberknife lung tracking and meet the requirements of Report of AAPM TG-135 and WS 667-
2019 standard. Therefore, the homemade lung phantom is feasible for clinical quality control of Cyberknife.
7.Study on the potential allergen and mechanism of pseudo-allergic reactions induced by combined using of Reduning injection and penicillin G injection based on metabolomics and bioinformatics
Yu-long CHEN ; You ZHAI ; Xiao-yan WANG ; Wei-xia LI ; Hui ZHANG ; Ya-li WU ; Liu-qing YANG ; Xiao-fei CHEN ; Shu-qi ZHANG ; Lu NIU ; Ke-ran FENG ; Kun LI ; Jin-fa TANG ; Ming-liang ZHANG
Acta Pharmaceutica Sinica 2024;59(2):382-394
Based on the strategy of metabolomics combined with bioinformatics, this study analyzed the potential allergens and mechanism of pseudo-allergic reactions (PARs) induced by the combined use of Reduning injection and penicillin G injection. All animal experiments and welfare are in accordance with the requirements of the First Affiliated Experimental Animal Ethics and Animal Welfare Committee of Henan University of Chinese Medicine (approval number: YFYDW2020002). Based on UPLC-Q-TOF/MS technology combined with UNIFI software, a total of 21 compounds were identified in Reduning and penicillin G mixed injection. Based on molecular docking technology, 10 potential allergens with strong binding activity to MrgprX2 agonist sites were further screened. Metabolomics analysis using UPLC-Q-TOF/MS technology revealed that 34 differential metabolites such as arachidonic acid, phosphatidylcholine, phosphatidylserine, prostaglandins, and leukotrienes were endogenous differential metabolites of PARs caused by combined use of Reduning injection and penicillin G injection. Through the analysis of the "potential allergen-target-endogenous differential metabolite" interaction network, the chlorogenic acids (such as chlorogenic acid, neochlorogenic acid, cryptochlorogenic acid, and isochlorogenic acid A) and
8.Three-dimensional Printing of Inertial Microchannel with Complex Cross-section and Characterization of Particle Inertial Focusing
Qiao GU ; Xin-Jie ZHANG ; Yao LIU ; Yang BAO ; Hang-Jie ZHU ; Ya-Wei CHEN
Chinese Journal of Analytical Chemistry 2024;52(1):93-101
Projection micro stereolithography three-dimensional(3D)printing method was proposed in this study to fabricate complex microchannels of combined cross-sections.By using 3D printing and polydimethylsiloxane(PDMS)replication methods,two inertial microfluidic chips of three-step and five-step cross-sections were fabricated,and the dimension precisions of the microchannels were controlled within 20 μm.Using the microfluidic chips,the movements of two fluorescent polystyrene particles with diameters of 10 and 6 μm in the stepped channels were investigated.In addition,numerical simulations were applied to demonstrate the inertial focusing mechanisms of particles in the channels.It was found that 10-μm particles had three equilibrium positions in the three-step channel,which located at the inner walls of the three steps,respectively,and most particles focused at the inner step.The 6-μm particles also had three equilibrium positions in the three-step channel.However,the particles migrated to the middle and the outer steps under high flow rates.In the five-step channel,when the flow rate was increased gradually,10-μm particles had a single and two equilibrium positions,respectively,and the particles migrated towards the inner channel wall under high flow rates.In comparison to 10-μm particles,6-μm particles had two stable equilibrium positions in the five-step channel at all flow rate range.It could be concluded that the quantity,shape and strength of the secondary flow vortex could be altered by changing structure of the combined cross-section,thus the equilibrium positions and quantities of the focusing particles could be also regulated.The research outcome might provide new insights for precise cell inertial manipulation and promote the application and development of inertial microfluidic technology in biomedical and other fields.
9.Investigation,traceability analysis,and discussion of food poisoning caused by Salmonella typhimurium ST19
Shu-Kun YU ; Lang LIU ; Ya-Xin TAN ; Zi-Yan CUI ; Xing-Yu XU ; Zhi-Yang TAO
Chinese Journal of Zoonoses 2024;40(1):82-89
To perform a comprehensive analysis of the pathogenic causes of a food poisoning case in a district of Wuhan Cit-y,we investigated the molecular epidemiological relationships among pathogenic bacteria,to aid in traceability analysis of food-borne disease outbreaks,as well as clinical diagnosis and treatment.The pathogenic bacteria in this food poisoning case were i-solated and identified according to GB789.4-2016.The isolated strains were subjected to genotyping with pulsed field gel elec-trophoresis(PFGE).Drug resistance gene analysis,multi-locus sequence typing(MLST),and genome-wide single-nucleotide polymorphism analysis(wgSNP)were conducted via whole genome sequencing(WGS).The evolutionary tree for cluster analy-sis was constructed in fasttree software.Drug susceptibility testing was conducted with the broth microdilution method.A total of 12 strains of Salmonella were detected in seven anal swab samples and two fecal samples from the case,as well as three anal swab samples from unaffected individuals.The serotype of the strains was Salmonella typhimurium.The strain exhibited severe multiple drug resistance,including resistance to amikacin,ampi-cillin,cefazolin,gentamicin,piperacillin,and tetracycline,but susceptibility to other antibiotics.The coincidence rate between drug resistance genes and drug resistance phenotypes was high.PFGE revealed that nine strains from this food poisoning case were highly homologous.WGS revealed that the MLST type was ST19,and varying numbers of SNPs(1-6)were present a-mong strains.The phylogenetic tree revealed nine isolated strains forming a distinct cluster,differing from other Salmonella strains in the database and belonging to a novel clonal branch.The single nucleotide site in the strains was highly homologous to that of GCF in Jiangxi_020221795.1.The food poisoning case was caused by Salmonella typhimurium ST19,and all nine iso-lated strains originated from the same source.The chef is closely connected to this food poisoning case.This strain of Salmo-nella typhimurium belongs to a new clonal branch and exhibits multiple drug resistance.
10.Percutaneous Kirschner wire leverage plus plaster fixation versus elastic intramedullary nailing for radial neck fractures in children
Fuyong ZHANG ; Wendong LIU ; Xiaodong WANG ; Yunfang ZHEN ; Tantan ZHAO ; Ya LIU ; Yuhao YANG ; Mincheng ZOU ; Yunpeng MAO
Chinese Journal of Orthopaedic Trauma 2024;26(2):143-148
Objective:To compare the clinical outcomes between percutaneous Kirschner wire leverage plus plaster fixation and elastic intramedullary nailing in the treatment of radial neck fractures in children.Methods:A retrospective study was conducted to analyze the 60 children with radial neck fracture who had been treated by percutaneous Kirschner wire leverage plus plaster fixation at Department of Pediatric Orthopedics, Children's Hospital of Soochow University from January 2016 to July 2023 (set as an internal fixation-free group). They were 30 males and 30 females (34 left and 26 right sides) with an age of (7.7±3.0) years. At the same time, another cohort of 60 patients were chosen as an intramedullary nailing group who had been treated by percutaneous Kirschner wire leverage plus elastic intramedullary nailing and matched in age and gender with those in the internal fixation-free group. The preoperative fracture angulation, operative time, hospitalization time, fracture angulation on the first postoperative day, fracture angulation at 1 month postoperatively, rate of angulation loss after reduction, Mayo elbow performance score (MEPS) at the last follow-up and complications were compared between the 2 groups.Results:There was no significant difference between the 2 groups in their preoperative general data, showing comparability ( P<0.05). The 120 pediatric patients were followed up for (7.5±3.2) months. The operative time [(27.4±15.0) min] and hospitalization time [(3.4±1.9) d] in the internal fixation-free group were significantly shorter than those in the intramedullary nailing group [(45.4±13.5) min and (4.4±1.3) d] ( P<0.05). The preoperative fracture angulation (50.8°±1.9°), fracture angulation on the first postoperative day (11.3°±1.2°), fracture angulation at 1 month postoperatively (12.1°±1.3°), rate of angulation loss after reduction (2.9%±0.5%), and MEPS at the last follow-up [(90.4±2.0) points] in the internal fixation-free group showed no significant differences from those in the intramedullary nailing group [49.5°±1.7°, 11.1°±1.2°, 13.3°±1.5°, 3.9%±1.4%, and (90.2±2.3) points] ( P>0.05). None of the patients in the internal fixation-free group developed pin-tail irritation sign or premature epiphyseal closure after surgery, whereas 3 patients in the intramedullary nailing group developed pin-tail irritation sign and 2 ones premature epiphyseal closure after surgery, showing a significant difference in the complication rate between the 2 groups [0 (0/60) versus 8.3% (5/60)] ( P<0.05). Conclusions:Percutaneous Kirschner wire leverage plus plaster fixation and close elastic intramedullary nailing can both achieve satisfactory outcomes in the treatment of radial neck fractures in children. However, percutaneous Kirschner wire leverage plus plaster fixation needs shorter operative time and hospitalization time, leads to fewer complications, and requires no reoperation to remove internal fixation.