1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Case study on functional orientation in a tertiary public hospital against the backdrop of performance appraisal of tertiary public hospitals
Wen ZHANG ; Xinxin ZHANG ; Ying XU ; Wenjia LI ; Xueli YAN ; Xiaozai ZHANG ; Xiaoyu YANG ; Ya KANG ; Yinghui HU ; Deying KONG ; Yiping GUO ; Yanghua ZHANG ; Shujuan FAN ; Yiping MU ; Hongxia LI ; Huang ZUO
Modern Hospital 2024;24(1):71-75
Performance appraisal of public hospitals have given a guidance for the development of public hospitals at all levels.A Class A tertiary hospital reviewed the problems in the development of the hospital at the present stage and focused on the following four aspects:①insufficient fine management;②No clear orientation of discipline development;③The bottleneck of the improvement of medical operation efficiency;④New challenges in the reform of payment mode.The tertiary hospital launched a fine management practice in May 2022,in order to solve the problems by taking the Department of Surgery as a pilot area,laying the foundation for fine management through information system construction,improving the efficiency of medical operation through management process optimization,improving the overall competitiveness of disciplines through the construction of sub-specialty and Discipline Alliance and adjusting the performance appraisal index system to play the role of performance incentives.The measures effectively improve the overall capacity and efficiency of hospital medical services and help the hospital to achieve high-quality development.
7.Clinicopathological Features and Long-Term Prognostic Role of Human Epidermal Growth Factor Receptor-2 Low Expression in Chinese Patients with Early Breast Cancer:A Single-Institution Study
Qing Zi KONG ; Qun Li LIU ; Qin De HUANG ; Tong Yu WANG ; Jie Jing LI ; Zheng ZHANG ; Xi Xi WANG ; Ling Chuan LIU ; Di Ya ZHANG ; Kang Jia SHAO ; Min Yi ZHU ; Meng Yi CHEN ; Mei LIU ; Hong Wei ZHAO
Biomedical and Environmental Sciences 2024;37(5):457-470
Objective This study aimed to comprehensively analyze and compare the clinicopathological features and prognosis of Chinese patients with human epidermal growth factor receptor 2(HER2)-low early breast cancer(BC)and HER2-IHC0 BC. Methods Patients diagnosed with HER2-negative BC(N=999)at our institution between January 2011 and December 2015 formed our study population.Clinicopathological characteristics,association between estrogen receptor(ER)expression and HER2-low,and evolution of HER2 immunohistochemical(IHC)score were assessed.Kaplan-Meier method and log-rank test were used to compare the long-term survival outcomes(5-year follow-up)between the HER2-IHC0 and HER2-low groups. Results HER2-low BC group tended to demonstrate high expression of ER and more progesterone receptor(PgR)positivity than HER2-IHC0 BC group(P<0.001).The rate of HER2-low status increased with increasing ER expression levels(Mantel-Haenszel χ2 test,P<0.001,Pearson's R=0.159,P<0.001).Survival analysis revealed a significantly longer overall survival(OS)in HER2-low BC group than in HER2-IHC0 group(P=0.007)in the whole cohort and the hormone receptor(HR)-negative group.There were no significant differences between the two groups in terms of disease-free survival(DFS).The discordance rate of HER2 IHC scores between primary and metastatic sites was 36.84%. Conclusion HER2-low BC may not be regarded as a unique BC group in this population-based study due to similar clinicopathological features and prognostic roles.
8.Changing trend and multivariate analysis of prevalence rates of healthcare-associated infection in a tertiary hospital for 10 years
Zi-Quan ZHOU ; Jin-Ai QIN ; Juan HUANG ; Yong-Kang YE ; Qun-Xiu GUO ; Lan-Lan LI ; Jing-Jing YA ; Ying-Hua ZHANG
Chinese Journal of Infection Control 2024;23(9):1135-1141
Objective To describe the changing trend and related factors of prevalence rates of healthcare-associa-ted infection(HAI)in a tertiary hospital in the past 10 years,and analyze the influencing factors for HAI.Methods A cross-sectional survey on HAI was conducted for 10 consecutive years from 2013 to 2022(one day was selected as the survey day each year),data were collected.The distribution and related factors of prevalence rates of HAI were analyzed by trend-x2 test and Pearson correlation coefficient.Multivariate logistic regression and multilayer percep-tron(MLP)models were constructed to analyze the independent effect and significance of factors.Results From 2013 to 2022,the prevalence rates of HAI ranged from 4.66%to 8.07%in this hospital,showing a linear upward trend.The proportions of ICU patients and utilization rate of central venous catheters within 2 days before the sur-vey showed linear upward trends,while the proportion of patients with urinary catheters within 2 days before the survey and proportion of patients undergoing surgery within 30 days before the survey decreased.The MLP model revealed that the top 3 important factors for HAI were length of hospital stay>10 days,admission in ICU,and in-dwelling central venous catheters within 2 days before the survey.Multivariate logistic regression model indicated that length of hospital stay>10 days,indwelling central venous catheters or urinary catheters within 2 days before the survey,surgery within 30 days before the survey,and admission in ICU were independent influencing factors for HAI.Conclusion The incidence of HAI in this hospital presents a linear increase in recent 10 years,the causes should be further analyzed and the direction of intervention should be determined through targeted surveillance.Adopting trend test statistical analysis method,logistic regression,MLP multi-factor model can further explore the data value of HAI prevalence survey.
9.Effects of anthoxanthin on the growth,proliferation and in-vasion of human gastric cancer cell line SGC7901
Hao-Yu ZHANG ; Xin KANG ; Bin LI ; Tian-Sheng YIN ; Ya-Jun ZHANG
Chinese Journal of Current Advances in General Surgery 2024;27(4):259-263
Objective:To investigate the effect of anthoxanthin on the proliferation and apopto-sis of human gastric cancer cell line SGC7901 and its possible mechanism.Methods:SGC7901 was cultured in the medium containing different concentrations(0,20,40,80 μ mol/L)of antho-cyanin.Hoechst staining,MTT colorimetry and flow cytometry were used to verify the effect of Form on the inhibition rate,cell cycle,nuclear morphology and apoptosis.Western Blotting was used to test the level of β-Catenin、p-β-Catenin,CyclinD1,CDK4,p-AKT,AKT,BCL-2,BAX,caspase3 and other proteins.The mRNA expression of BCL-2,CDK4,CDK6,AKT,CyclinD1,BAX,Caspase3 was detected by RT-PCR.Results:MTT results showed that the inhibitory effect of Form on SGC7901 was concentration dependent and time dependent.Hoechst staining showed that the cells in the experimental group(20,40,80 μ mol/L),the phenomenon of pyknosis and dissolution of the nucleus,even granular aggregation after rupture.Flow cytometry showed that the apoptosis rate of the experimental group(20 μ mol/L,40 μ mol/L,80 μ mol/L)was 17.0%,21.5%,32.5%respectively after treated with different concentrations of Form for 48 hours,which was positively correlated with the drug concentration.RT-PCR showed that caspase3 and BAX mRNA expression increased with the increase of Form intervention concentration(P<0.01);the mRNA expression of BCL-2,CDK4,CDK6,AKT,CyclinD1 decreased(P<0.01).WB results showed that β-Catenin、p-β-Catenin,Cy-clinD1,CDK4 and p-AKT,AKT,BCL-2 decreased with the increase of Form intervention concentra-tion(P<0.01);The relative expression of caspase3,BAX and other proteins increased(P<0.01).Con-clusion:Form can promote apoptosis of SGC7901,and the possible mechanism is to inhibit Wnt/β-Catenin signal;it also mediates the activation of Caspase family.
10.Design of intelligent positioning system for mobile medical equipment in operating room based on Bluetooth technology
Zhi-Meng LIU ; Ya-Dong LYU ; Long-Xue QIAO ; Lin-Huai TIAN ; Kun YANG ; Kai-Yuan LI ; Ning-Bo ZHAN ; Ying-Kang WEI ; Yong CHAO
Chinese Medical Equipment Journal 2023;44(9):29-32
Objective To develop an intelligent positioning system for mobile medical equipment in the operating room based on Bluetooth technology to enhance medical equipment management efficiency.Methods The intelligent positioning system for mobile medical equipment used received signal strength indication(RSSI)algorithm and multi-gateway trajectory filtering algorithm to realize Bluetooth positioning,which was composed of Bluetooth gateways,Bluetooth beacons,Bluetooth labels and a background data processing platform.The Bluetooth gateway consisted of an active power over ethernet(POE)module,a DC power module,a CPU,a Wi-Fi module and a Bluetooth module;the Bluetooth beacon included a beacon control unit,a Bluetooth transmitter module and a Bluetooth receiver module;the Bluetooth label was made up of a microcontroller unit(MCU),a Bluetooth module,an anti-temper switch and a accelerometer;the data processing platform had the front end developed with Vue architecture and the back end with Java language.Results The system developed could accurately locate the medical equipment in the operating room without electromagnetic interference to other medical devices.Conclusion The system developed gains advantages in high positioning accuracy,low electromagnetic interference,high stability and reliability and low cost,which improves the positioning and management efficiency of medical equipment under the premise of ensuring safety.[Chinese Medical Equipment Journal,2023,44(9):29-32]

Result Analysis