1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
		                				6.Identification and anti-inflammatory activity of chemical constituents and a pair of new monoterpenoid enantiomers from the fruits of Litsea cubeba 
		                			
		                			Mei-lin LU ; Wan-feng HUANG ; Yu-ming HE ; Bao-lin WANG ; Fu-hong YUAN ; Ting ZHANG ; Qi-ming PAN ; Xin-ya XU ; Jia HE ; Shan HAN ; Qin-qin WANG ; Shi-lin YANG ; Hong-wei GAO
Acta Pharmaceutica Sinica 2024;59(5):1348-1356
		                        		
		                        			
		                        			 Eighteen compounds were isolated from the methanol extract of the fruits of 
		                        		
		                        	
7.Role and mechanism of RASAL1 in increase of pulmonary vascular endothelial permeability induced by homocysteine
Xin-Yi LI ; Kai-Yue QIN ; Zi-Yao YANG ; Ling ZHANG ; Zhen LI ; Ya-Li YANG ; Xi XU ; Xiao-Ling YANG
Chinese Pharmacological Bulletin 2024;40(8):1454-1461
		                        		
		                        			
		                        			Aim To investigate the effect of homocys-teine(Hcy)on the permeability of pulmonary micro-vascular endothelial cells(PMVECs)and the role and mechanism of RASAL1.Methods CBS+/-mice were fed a high methionine diet(HMD)for 16 weeks to replicate an animal model of hyperhomocysteinemia(HHcy).HE staining was used to observe the changes in lung tissue structure.qRT-PCR was used to detect the levels of RASAL1 and DNMT1 mRNA in lung tis-sue.Western blot was used to detect the expression of RASAL1,DNMT1,ZO-1,and VE cadherin proteins.Methylation specific PCR was used to detect methyla-tion in the RASAL1 promoter region.PMVECs were transfected with Ad-RASAL1 to detect the expression of ZO-1 and VE cadherin.The si-DNMT1 interference fragment was transfected into PMVECs,and the ex-pression of the RASAL1 was detected by qRT-PCR and Western blot.Results Serum Hcy level of HMD mice was significantly raised,and HE staining showed severe structural disorder in lung tissue.The expres-sion of RASAL1,ZO-1,and VE cadherin was de-creased,while the expression of DNMT1 was in-creased.The degree of methylation in the RASAL1 promoter region was raised.The expression of ZO-1 and VE cadherin increased after PMVECs were trans-fected with Ad-RASAL1.After knocking down DN-MT1,RASAL1 expression was increased.Conclusion Hcy can increase the permeability of PMVECs,and its mechanism is related to the upregulation of RASAL1 methylation level.
		                        		
		                        		
		                        		
		                        	
8.Expression pattern and function of novel gene C12ORF56 in lung cancer
Zeng ZHANG ; Hua-Zhen XU ; Run-He QIN ; Yun-Min HUANG ; Ya-Hao LING ; Wen-Lin CHANG
Chinese Pharmacological Bulletin 2024;40(9):1680-1687
		                        		
		                        			
		                        			Aim To disclose the subcellular localiza-tion,expression pattern,cellular physiological function and possible molecular mechanism of C12ORF56,a novel gene located at q14.2 of chromosome 12,in the pathogenesis of lung cancer.Methods ONCOMINE database was applied to investigate the mRNA level dif-fering of C12ORF56 between normal and lung cancer tissues.Analysis based on LinkedOmics,Metascape,String and GSEA database or tools provided indication of potential cellular physiological functions of C12ORF56 in the developing of lung cancer.C12ORF56 was knocked down via siRNA and the pro-liferation of NCI-H1073 cells were observed by EdU and CCK-8 assay.RT-qPCR was used to detect the ex-pression level of C12ORF56 of lung cancer cells on dif-ferent cycle phases.The core sequence regions of pro-moter affecting the transcription of C12ORF56 gene were analyzed by Jaspar online-tools and verified by dual-luciferase assay.Results C12ORF56 was highly expressed in lung cancer cells,especially in squamous cell lung cancer.C12ORF56 correlated with cell cy-cle,cancer immune,DNA replication.Knockdown of C12ORF56 reduced NCI-H1703 cell proliferation.Conclusion The up-regulation of C12ORF56 is in-volved in the development of lung cancer by enhancing lung cancer cell proliferation.
		                        		
		                        		
		                        		
		                        	
9.Risk factors for bronchopulmonary dysplasia in twin preterm infants:a multicenter study
Yu-Wei FAN ; Yi-Jia ZHANG ; He-Mei WEN ; Hong YAN ; Wei SHEN ; Yue-Qin DING ; Yun-Feng LONG ; Zhi-Gang ZHANG ; Gui-Fang LI ; Hong JIANG ; Hong-Ping RAO ; Jian-Wu QIU ; Xian WEI ; Ya-Yu ZHANG ; Ji-Bin ZENG ; Chang-Liang ZHAO ; Wei-Peng XU ; Fan WANG ; Li YUAN ; Xiu-Fang YANG ; Wei LI ; Ni-Yang LIN ; Qian CHEN ; Chang-Shun XIA ; Xin-Qi ZHONG ; Qi-Liang CUI
Chinese Journal of Contemporary Pediatrics 2024;26(6):611-618
		                        		
		                        			
		                        			Objective To investigate the risk factors for bronchopulmonary dysplasia(BPD)in twin preterm infants with a gestational age of<34 weeks,and to provide a basis for early identification of BPD in twin preterm infants in clinical practice.Methods A retrospective analysis was performed for the twin preterm infants with a gestational age of<34 weeks who were admitted to 22 hospitals nationwide from January 2018 to December 2020.According to their conditions,they were divided into group A(both twins had BPD),group B(only one twin had BPD),and group C(neither twin had BPD).The risk factors for BPD in twin preterm infants were analyzed.Further analysis was conducted on group B to investigate the postnatal risk factors for BPD within twins.Results A total of 904 pairs of twins with a gestational age of<34 weeks were included in this study.The multivariate logistic regression analysis showed that compared with group C,birth weight discordance of>25%between the twins was an independent risk factor for BPD in one of the twins(OR=3.370,95%CI:1.500-7.568,P<0.05),and high gestational age at birth was a protective factor against BPD(P<0.05).The conditional logistic regression analysis of group B showed that small-for-gestational-age(SGA)birth was an independent risk factor for BPD in individual twins(OR=5.017,95%CI:1.040-24.190,P<0.05).Conclusions The development of BPD in twin preterm infants is associated with gestational age,birth weight discordance between the twins,and SGA birth.
		                        		
		                        		
		                        		
		                        	
10.Clinical study of modified suspension reduction method combined with percutaneous vertebroplasty in the treatment of thoracolumbar osteoporotic compression fracture
Yu-Zhou LU ; Yu WANG ; Xiao-Xu YANG ; Cheng-Qiang WU ; Shou-Cui ZHANG ; Jin-Guo WANG ; Ya-Dong WU ; Dong QIN ; Lin DING
China Journal of Orthopaedics and Traumatology 2024;37(1):21-26
		                        		
		                        			
		                        			Objective To investigate the clinical effect of modified suspension reduction method combined with percuta-neous vertebroplasty in the treatment of osteoporotic thoracolumbar compression fractures.Methods From February 2020 to October 2021,92 patients with thoracolumbar osteoporotic compression fracture were treated by percutaneous vertebroplasty.According to different treatment methods,they were divided into the observation group and the control group.The observation group was treated with modified suspension reduction and then percutaneous vertebroplasty,while the control group was treated with percutaneous vertebroplasty alone.The observation group(47 cases),including 20 males and 27 females,the age ranged from 59 to 76 years old with an average of(69.74±4.50)years old,fractured vertebral bodies:T10(2 cases),T11(7 cases),T12(19 cases),L1(14 cases),L2(5 cases);the control group(45 cases),including 21 males and 24 females,the age ranged from 61 to 78 years old with an average of(71.02±3.58)years old,fractured vertebral bodies:T10(3 cases),T11(8 cases),T12(17 cas-es),L1(12 cases),L2(5 cases);The leakage of bone cement were observed,the visual analogue scale(VAS),Oswestry lumbar dysfunction index(ODI),anterior vertebrae height(AVH),Cobb angle of kyphosis and the amount of bone cement injected before and after operation were recorded and compared between the two groups.Results All patients were followed up,ranged from 6 to1O with an average of(8.45±1.73)months.Two patients ocurred bone cement leakage in observation group and 3 pa-tients in control group.AVH of observation group increased(P<0.05)and Cobb angle of injured vertebrae decreased(P<0.05).Cobb angle of injured vertebrae and AVH of the control group were not significantly changed(P>0.05).Cobb angle of injured vertebrae of the observation group was lower than that of control group(P<0.05)and AVH was higher than that of the control group(P<0.05).In the observation group,VAS before operation and 1 week,3 and 6 months after operation respective-ly were(7.32±1.05)scores,(3.56±1.18)scores,(1.83±0.67)scores,(1.27±0.34)scores,and ODI were(40.12±14.69)scores,(23.76±10.19)scores,(20.15±6.39)scores,(13.45±3.46)scores.In the control group,VAS before operation and 1 week,3 and 6 months after operation respectively were(7.11±5.26)scores,(3.82±0.68)scores,(1.94±0.88)scores,(1.36± 0.52)scores,and ODI were(41.38±10.23)scores,(25.13±14.22)scores,(20.61±5.82)scores,(14.55±5.27)scores.The scores of VAS and ODI after operation were lower than those before operation(P<0.05),but there was no significant difference between the two groups(P<0.05).Conclusion Modified suspension reduction method combined with PVP surgery for osteo-porotic thoracolumbar compression fractures has achieved good clinical results,which can effectively relieve lumbar back pain,restore vertebral height,correct kyphosis,improve lumbar function and patients'quality of life.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail