1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Inflammatory and Immunomodulatory Effects of Tripterygium wilfordii Multiglycoside in Mouse Models of Psoriasis Keratinocytes.
Shuo ZHANG ; Hong-Jin LI ; Chun-Mei YANG ; Liu LIU ; Xiao-Ying SUN ; Jiao WANG ; Si-Ting CHEN ; Yi LU ; Man-Qi HU ; Ge YAN ; Ya-Qiong ZHOU ; Xiao MIAO ; Xin LI ; Bin LI
Chinese journal of integrative medicine 2024;30(3):222-229
OBJECTIVE:
To determine the role of Tripterygium wilfordii multiglycoside (TGW) in the treatment of psoriatic dermatitis from a cellular immunological perspective.
METHODS:
Mouse models of psoriatic dermatitis were established by imiquimod (IMQ). Twelve male BALB/c mice were assigned to IMQ or IMQ+TGW groups according to a random number table. Histopathological changes in vivo were assessed by hematoxylin and eosin staining. Ratios of immune cells and cytokines in mice, as well as PAM212 cell proliferation in vitro were assessed by flow cytometry. Pro-inflammatory cytokine expression was determined using reverse transcription quantitative polymerase chain reaction.
RESULTS:
TGW significantly ameliorated the severity of IMQ-induced psoriasis-like mouse skin lesions and restrained the activation of CD45+ cells, neutrophils and T lymphocytes (all P<0.01). Moreover, TGW significantly attenuated keratinocytes (KCs) proliferation and downregulated the mRNA levels of inflammatory cytokines including interleukin (IL)-17A, IL-23, tumor necrosis factor α, and chemokine (C-X-C motif) ligand 1 (P<0.01 or P<0.05). Furthermore, it reduced the number of γ δ T17 cells in skin lesion of mice and draining lymph nodes (P<0.01).
CONCLUSIONS
TGW improved psoriasis-like inflammation by inhibiting KCs proliferation, as well as the associated immune cells and cytokine expression. It inhibited IL-17 secretion from γ δ T cells, which improved the immune-inflammatory microenvironment of psoriasis.
Male
;
Animals
;
Mice
;
Tripterygium
;
Psoriasis/drug therapy*
;
Keratinocytes
;
Skin Diseases/metabolism*
;
Cytokines/metabolism*
;
Imiquimod/metabolism*
;
Dermatitis/pathology*
;
Disease Models, Animal
;
Mice, Inbred BALB C
;
Skin/metabolism*
7.Study on the potential allergen and mechanism of pseudo-allergic reactions induced by combined using of Reduning injection and penicillin G injection based on metabolomics and bioinformatics
Yu-long CHEN ; You ZHAI ; Xiao-yan WANG ; Wei-xia LI ; Hui ZHANG ; Ya-li WU ; Liu-qing YANG ; Xiao-fei CHEN ; Shu-qi ZHANG ; Lu NIU ; Ke-ran FENG ; Kun LI ; Jin-fa TANG ; Ming-liang ZHANG
Acta Pharmaceutica Sinica 2024;59(2):382-394
Based on the strategy of metabolomics combined with bioinformatics, this study analyzed the potential allergens and mechanism of pseudo-allergic reactions (PARs) induced by the combined use of Reduning injection and penicillin G injection. All animal experiments and welfare are in accordance with the requirements of the First Affiliated Experimental Animal Ethics and Animal Welfare Committee of Henan University of Chinese Medicine (approval number: YFYDW2020002). Based on UPLC-Q-TOF/MS technology combined with UNIFI software, a total of 21 compounds were identified in Reduning and penicillin G mixed injection. Based on molecular docking technology, 10 potential allergens with strong binding activity to MrgprX2 agonist sites were further screened. Metabolomics analysis using UPLC-Q-TOF/MS technology revealed that 34 differential metabolites such as arachidonic acid, phosphatidylcholine, phosphatidylserine, prostaglandins, and leukotrienes were endogenous differential metabolites of PARs caused by combined use of Reduning injection and penicillin G injection. Through the analysis of the "potential allergen-target-endogenous differential metabolite" interaction network, the chlorogenic acids (such as chlorogenic acid, neochlorogenic acid, cryptochlorogenic acid, and isochlorogenic acid A) and
8.Network meta-analysis of the modeling effects of different factors on rabbit models of steroid-induced osteonecrosis of femoral head
Zhixing HU ; Qun LI ; Chao YANG ; Xiaoxiao WANG ; Luochangting FANG ; Wuqiong HOU ; Na LIN ; Weiheng CHEN ; Chunfang LIU ; Ya LIN
Chinese Journal of Tissue Engineering Research 2024;28(6):976-984
OBJECTIVE:The rabbit model of steroid-induced osteonecrosis of femoral head is the most commonly used animal model of femoral head necrosis.The pathological changes of the femoral head are close to clinical practice,however,the conditions,methods and evaluation standards of animal models reported in and outside China are not uniform,which leads to the low scientific value of animal models and is difficult to popularize.This study aimed to clarify the influence of different mold-making conditions on the establishment of steroid-induced osteonecrosis of femoral head rabbit model and analyze the appropriate conditions for the successful model establishment. METHODS:We searched the CNKI,WanFang,VIP,CBM,WoS,PubMed and EMbsae databases for the literature on the modeling of steroid-induced osteonecrosis of femoral head rabbits up to April 1,2022,completed the screening of the literature according to the inclusion and exclusion criteria and literature quality evaluation,and extracted the outcome index data in the literature.RevMan Stata and ADDIS statistical software were used to conduct a meta-analysis of the included data. RESULTS:(1)A total of 82 articles with 1 366 rabbits were included in the study.The steroid-induced osteonecrosis of femoral head modeling methods were divided into three types:steroid-alone method,steroid combined lipopolysaccharide method and steroid combined serum method.Among these,33 articles used steroid-alone method;20 articles used steroid combined lipopolysaccharide method;29 articles used steroid combined serum method.(2)Meta-analysis results showed that the three modeling methods significantly increased the rate of empty bone lacunae in the femoral head of steroid-induced osteonecrosis of femoral head rabbits(P<0.001),and significantly decreased the ratio of the trabecular bone area in the femoral head of steroid-induced osteonecrosis of femoral head rabbits(P<0.001).The order of empty bone lacunae rate of each modeling method was:steroid combined with lipopolysaccharide method>steroid-alone method>steroid combined with serum method>normal group,and the order of trabecular bone area rate of each modeling method was:normal group>steroid combined with serum method>steroid-alone method>steroid combined with lipopolysaccharide method.(3)The results of subgroup analysis suggested that the rate of empty bone lacunae in the rabbit model induced by steroid alone might be related to the rabbit variety and the type of steroid used for modeling(difference between groups P<0.05),in which the combined effect amount of New Zealand white rabbits was higher than that of Chinese white rabbits(P<0.05)and Japanese white rabbits,and the combined effect amount of dexamethasone was higher than that of other steroids.The rate of empty bone lacunae induced by steroid combined with lipopolysaccharide was related to the administration mode of lipopolysaccharide and the type of steroid(P<0.05),among which the combined effect of methylprednisolone sodium succinate was significantly higher than that of other steroids(P<0.05),and the combined effect of prednisolone was significantly lower than that of other steroids(P<0.05).The combined effect of lipopolysaccharide 100 μg/kg×twice was significantly lower than 10 μg/kg×twice and 50 μg/kg×twice(P<0.05).The rate of empty bone lacunae in the model induced by steroid combined with serum was related to serum dose and steroid type(P<0.05),among which the combined effect amount of dexamethasone sodium phosphate was significantly higher than other steroid types(P<0.05),and the combined effect amount of dexamethasone was significantly lower than other steroid types(P<0.05);the combined effect amount of serum"10 mL/kg+6 mL/kg"combined dose was lower than other serum doses(P<0.05). CONCLUSION:(1)With the rate of empty bone lacunae and the ratio of trabecular bone area as the judgment standard for the successful establishment of the model,the three modeling methods can successfully construct the rabbit steroid-induced osteonecrosis of femoral head model,of which the steroid combined with lipopolysaccharide method is the best.(2)New Zealand white rabbits and dexamethasone are recommended when selecting the steroid-alone method.Methylprednisolone sodium succinate and low-dose lipopolysaccharide are recommended when selecting the steroid combined with lipopolysaccharide method.Dexamethasone sodium phosphate is recommended when selecting the steroid combined with serum modeling method.
9.The effectiveness of fluorescence labeling-based assay bundle intervention in the prevention and control of multidrug-resistant organism infection
Ting-Zheng QIN ; Yun LIU ; Yue-Wei HAO ; Na YANG ; Ya-Teng SONG ; Xiao-Qun WANG ; Wei-Guang LI
Chinese Journal of Infection Control 2024;23(2):225-230
Objective To observe the effectiveness of fluorescence labeling-based assay bundle intervention in the prevention and control of multidrug-resistant organism(MDRO)infection.Methods Patients who were detected MDRO in a hospital from January to December 2022 were selected as the research subjects.MDRO monitoring data and implementation status of prevention and control measures were collected.Fluorescence labeling assay was adopted to monitor the cleaning and disinfection effectiveness of the surrounding object surface of the bed units.Based on the bundled prevention and control measures as well as management mode of the pre-intervention group,the post-intervention group implemented enhanced rectification measures for the problems found by the pre-interven-tion group.Changes in relevant indicators between January-June 2022(before intervention)and July-December 2022(after intervention)were compared.Results There were 136 MDRO-infected patients in the pre-intervention group,208 MDRO strains were detected and 10 healthcare-associated infection(HAI)occurred.There were 128 MDRO-infected patients in the post-intervention group,198 MDRO strains were detected and 9 HAI occurred.Af-ter intervention,the total detection rates of methicillin-resistant Staphylococcus aureus(MRSA),carbapenem-re-sistant Acinetobacter baumannii(CRAB),and total MDRO from patients decreased significantly compared to before intervention(all P<0.05).After intervention,the detection rates of MRSA,carbapenem-resistant Pseudomonas aeruginosa(CRPA),CRAB,and total MDRO from the surrounding object surface were all lower than those before intervention(all P<0.05).The detection rate of MDRO from surrounding object surface before intervention was 34.52%,which showed a decreased trend after intervention(P<0.05).The clearance rate of fluorescent labeled markers before intervention was 41.84%,which showed an upward trend after implementing intervention measures(from July to December),and increased to 85.00%at the end of intervention(November-December).The comp-liance rates of issuing isolation medical orders,placing isolation labels,using medical supplies exclusively,and cor-rectly handling medical waste after intervention have all increased compared to before intervention(all P<0.05).Conclusion Adopting fluorescence labeling-based assay bundle intervention can effectively improve the effectiveness of MDRO infection prevention and control.
10.Investigation,traceability analysis,and discussion of food poisoning caused by Salmonella typhimurium ST19
Shu-Kun YU ; Lang LIU ; Ya-Xin TAN ; Zi-Yan CUI ; Xing-Yu XU ; Zhi-Yang TAO
Chinese Journal of Zoonoses 2024;40(1):82-89
To perform a comprehensive analysis of the pathogenic causes of a food poisoning case in a district of Wuhan Cit-y,we investigated the molecular epidemiological relationships among pathogenic bacteria,to aid in traceability analysis of food-borne disease outbreaks,as well as clinical diagnosis and treatment.The pathogenic bacteria in this food poisoning case were i-solated and identified according to GB789.4-2016.The isolated strains were subjected to genotyping with pulsed field gel elec-trophoresis(PFGE).Drug resistance gene analysis,multi-locus sequence typing(MLST),and genome-wide single-nucleotide polymorphism analysis(wgSNP)were conducted via whole genome sequencing(WGS).The evolutionary tree for cluster analy-sis was constructed in fasttree software.Drug susceptibility testing was conducted with the broth microdilution method.A total of 12 strains of Salmonella were detected in seven anal swab samples and two fecal samples from the case,as well as three anal swab samples from unaffected individuals.The serotype of the strains was Salmonella typhimurium.The strain exhibited severe multiple drug resistance,including resistance to amikacin,ampi-cillin,cefazolin,gentamicin,piperacillin,and tetracycline,but susceptibility to other antibiotics.The coincidence rate between drug resistance genes and drug resistance phenotypes was high.PFGE revealed that nine strains from this food poisoning case were highly homologous.WGS revealed that the MLST type was ST19,and varying numbers of SNPs(1-6)were present a-mong strains.The phylogenetic tree revealed nine isolated strains forming a distinct cluster,differing from other Salmonella strains in the database and belonging to a novel clonal branch.The single nucleotide site in the strains was highly homologous to that of GCF in Jiangxi_020221795.1.The food poisoning case was caused by Salmonella typhimurium ST19,and all nine iso-lated strains originated from the same source.The chef is closely connected to this food poisoning case.This strain of Salmo-nella typhimurium belongs to a new clonal branch and exhibits multiple drug resistance.

Result Analysis
Print
Save