1.Whole-transcriptome sequencing and bioinformatics analysis of calcified outer-layer tissue from cystic echinococcosis
Wang, S.B. ; Sun, H.H. ; Ma, Y.B. ; Dai, Y. ; Ren, Q. ; Liu, Y.Q. ; Shi, C.H. ; Tao, J. ; Li, J.
Tropical Biomedicine 2024;41(No.1):20-28
Echinococcosis is a common zoonotic disease in livestock; the type with the highest incidence is cystic
echinococcosis (CE). In clinical management, patients with CE of the liver in which the cyst wall is calcified
have been found to have better prognoses than those without calcification. In this study, we collected
calcified and uncalcified cyst wall tissue from patients with hepatic CE and observed significant changes
in the expression of 2336 messenger ribonucleic acids (mRNAs), 178 long noncoding RNAs (lncRNAs),
210 microRNAs (miRNAs), and 33 circular RNAs (circRNAs) using high-throughput sequencing (HTS).
Gene ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) enrichment analyses of
differentially expressed RNAs (DERNAs: DEmRNAs, DElncRNAs, DEmiRNAs, and DEcircRNAs) were
performed to explore these RNAs’ potential biological functions and signaling pathways. Ultimately,
the results of hematoxylin and eosin (H&E) and terminal deoxynucleotidyl transferase deoxyuridine
triphosphate (dUTP) nick end labeling (TUNEL) staining confirmed the correlation between calcification
and apoptosis of the cyst wall. In summary, this study was an initial exploration of the molecular-biological
mechanism underlying spontaneous calcification of the hydatid cyst wall, and it provides a theoretical
basis for exploring new targets for drug treatment in CE.
2.Effect of Echinococcus multilocularis infection on Tim3 expression in spleen natural killer cells of mice.
Y SHI ; A ABIDAN ; D LI ; R ZIBIGU ; M WANG ; X ZHENG ; X KANG ; H WANG ; J LI ; C ZHANG
Chinese Journal of Schistosomiasis Control 2023;35(4):366-373
OBJECTIVE:
To investigate the effect of Echinococcus multilocularis infection on Tim3 expression and its co-expression with immune checkpoint molecules 2B4 and LAG3 in spleen natural killer (NK) cells of mice.
METHODS:
C57BL/6 mice, each weighing (20 ± 2) g, were randomly divided into a high-dose infection group (15 mice), a low-dose infection group (13 mice), and a control group (11 mice). Mice in the high- and low-dose infection groups were inoculated with 2 000 and 50 Echinococcus multilocularis protoscolices via the hepatic portal vein, while animals in the control group was injected with an equivalent amount of physiological saline via the hepatic portal vein. Mouse spleen cells were harvested 12 and 24 weeks post-infection, and Tim3 expression and its co-expression with 2B4 and LAG3 in NK cells were detected using flow cytometry.
RESULTS:
There were significant differences in the proportions of Tim3 expression (F = 13.559, P < 0.001) and Tim3 and 2B4 co-expression (F = 12.465, P < 0.001) in mouse spleen NK cells among groups 12 weeks post-infection with E. multilocularis, and the proportion of Tim3 expression was significantly higher in mouse spleen NK cells in the low-dose infection group [(23.84 ± 2.28)%] than in the high-dose infection group [(15.72 ± 3.67)%] and the control group [(16.14 ± 3.83)%] (both P values < 0.01), while the proportion of Tim3 and 2B4 co-expression was significantly higher in mouse spleen NK cells in the low-dose infection group [(22.20 ± 2.13)%] than in the high-dose infection group [(14.17 ± 3.81)%] and the control group [(15.20 ± 3.77)%] (both P values < 0.01). There were significant differences in the proportions of Tim3 expression (F = 5.243, P < 0.05) and Tim3 and 2B4 co-expression (F = 4.659, P < 0.05) in mouse spleen NK cells among groups 24 weeks post-infection with E. multilocularis infection, and the proportions of Tim3 expression and Tim3 and 2B4 co-expression were significantly lower in mouse spleen NK cells in the high-dose infection group [(20.55 ± 7.04)% and (20.98 ± 7.12)%] than in the control group [(31.38 ± 3.19)% and (31.25 ± 3.06)%] (both P values < 0.05), and there were no significantly difference between the proportions of Tim3 expression and Tim3 and 2B4 co-expression in splenic NK cells in the low-dose infection group [(26.80 ± 6.47)% and (26.48 ± 6.48)%] and the control group (both P > 0.05). There were no significant differences in the proportions of Tim3 and LAG3 co-expression in mouse spleen NK cells among groups 12 (F = 2.283, P > 0.05) and 24 weeks post-infection (F = 0.375, P > 0.05). In the low-dose infection group, there were no significant differences in the proportions of Tim3 expression or Tim3 and 2B4 co-expression in mouse spleen NK cells 12 (t = -1.137, P > 0.05) or 24 weeks post-infection (t = -1.658, P > 0.05), and the proportion of Tim3 and LAG3 co-expression increased in mouse spleen NK cells 24 weeks post-infection relative to 12 weeks post-infection (t = -5.261, P < 0.01). In the highdose infection group, there was no significant difference in the proportion of Tim3 expression in mouse spleen NK cells 12 and 24 weeks post-infection (t = -1.546, P > 0.05); however, the proportions of Tim3 co-expression with 2B4 and LAG3 increased in mouse splenic NK cells 24 weeks post-infection relative to 12 weeks post-infection (t = -2.425 and -4.745, both P values < 0.05).
CONCLUSIONS
The Tim3 expression and Tim3 co-expression with LAG3 and 2B4 on spleen NK cells is affected by doses of E. multilocularis infection and disease stages, and present different phenotypes during the course of alveolar echinococcosis. NK cells tend to form an immunosuppressive phenotype with the progression of E. multilocularis infection, which facilitates immune escape and chronic parasitism of E. multilocularis.
Animals
;
Mice
;
Hepatitis A Virus Cellular Receptor 2/genetics*
;
Killer Cells, Natural
;
Mice, Inbred C57BL
;
Spleen
3.Pre-operative Halo-Pelvic Traction for Neurofibromatosis Patients with Severe Proximal Thoracic Spinal Deformity: Indications and Early Treatment Outcome
Chung WH ; Toyat SS ; Chiu CK ; Hasan MS ; Saw A ; Chan CYW ; Kwan MK ; Mihara Y
Malaysian Orthopaedic Journal 2021;15(No.3):99-107
Introduction: To report the indications and early treatment
outcomes of pre-operative halo-pelvic traction in patients
with neurofibromatosis associated with severe proximal
thoracic (PT) spinal deformity.
Materials and methods: We reviewed four patients with
neurofibromatosis with severe PT spinal deformity. Case 1, a
16-year-old male presented with severe PT kyphoscoliosis
(scoliosis: 89°, kyphosis: 124°) and thoracic myelopathy.
Case 2 was a 14-year-old, skeletally immature male who
presented with a PT lordoscoliosis (scoliosis: 85°). Case 3, a
13-year-old male, presented with severe PT kyphoscoliosis
(scoliosis: 100°, kyphosis: 95°). Case 4, a 35-year-old
gentleman, presented with severe PT kyphoscoliosis
(scoliosis: 113°, kyphosis: 103°) and thoracic myelopathy.
All patients underwent pre-operative halo-pelvic traction.
After a period of traction, all patients underwent posterior
spinal fusion (PSF) with autologous bone grafts (local and
fibula bone grafts) and recombinant human bone
morphogenetic protein-2 (rhBMP-2).
Results: Both patients with thoracic myelopathy regained
near normal neurological status after halo-pelvic traction.
Following traction, the scoliosis correction rate (CR) ranged
from 18.0% to 38.9%, while the kyphosis CR ranged from
14.6% to 37.1%. Following PSF, the scoliosis CR ranged
from 24.0% to 58.8%, while the kyphosis CR ranged from
29.1% to 47.4%. The total distraction ranged from 50-70mm.
Duration of distraction ranged from 26-95 days. The most
common complication encountered during halo-pelvic
traction was pin-related e.g. pin tract infection, pin loosening
and migration, osteomyelitis, and halo-pelvic strut breakage.
No patients had cranial nerve palsies or neurological
worsening.
Conclusion: Pre-operative correction of severe PT spinal
deformities could be performed safely and effectively with
the halo-pelvic device prior to definitive surgery.
4.Development of Motion Unit of Simulated Intelligent Endotracheal Suctioning Robot.
Wenjun TAN ; Cunyi SHEN ; Yu LUO ; Haoyang ZHU ; Tao MA ; Dinghui DONG ; Aihua SHI ; Zhao XUE ; Rongqian WU ; Y LYU
Chinese Journal of Medical Instrumentation 2019;43(1):17-20
A motion unit for sucking robot with a stable motion, convenient operation and process simulation is introduced. The key parameters and process data of the sucking operation were obtained from the clinical work, which provided the basis for the design of the sucking robot motion unit. According to the points of sucking action, robotic thumb, forefinger and metacarpophalangeal joints were used to grip the suction tube, and the servo and arm structure were used to simulate the motion of the wrist and elbow to complete the rotation and push of the sputum suction tube. The feasibility is verified through the advanced sputum suction training model. The movement unit is stable in movement, and can smoothly complete the clamping, feeding, back off protection and rotating tube removal of the sputum suction tube, so as to achieve effective sputum suction.
Catheterization
;
Intubation, Intratracheal
;
Robotics
;
Suction
5.Relationship between urinary cadmium and type 2 diabetes mellitus in adults.
L J LEI ; J Y GUO ; X J SHI ; H KANG ; T WANG ; Z ZHANG ; Y Y GAO
Chinese Journal of Epidemiology 2019;40(2):207-211
Objective: To explore the relationship between environmental factors as urinary cadmium and type 2 diabetes mellitus (DM) in adults. Methods: Case-control study was adopted, including 166 cases and 427 controls. General characteristics of the subjects were collected by a structured questionnaire. FPG, biochemical indexes and urinary cadmium (UCd) were detected respectively, while UCd was corrected with creatinine. Unconditioned logistic regression model was applied to analyze the relationship between UCd and DM. Results: Levels of UCd appeared higher in cases with the following characteristics as: having primary school education (P=0.016), being female (P=0.013), being non-smokers (P=0.014) or non-alcoholic (P=0.025), and with BMI>25.00 kg/m(2) (P=0.040, P=0.025) than those appeared in the control group. Same results were shown in the 60-69 years (P=0.024) old group. Data from the unconditional logistic regression analysis showed that family history of DM (OR=3.19, 95%CI: 1.45-7.03), education status (OR=1.50,95%CI: 1.08-2.08) and UCd (OR=1.61, 95%CI: 1.08-2.41) were influencing factors on DM. Conclusion: A close association between UCd and DM was noticed. UCd appeared a risk factor on DM that called for setting up related prevention program to reduce the exposure of Cd and to control the risk on DM.
Adult
;
Cadmium/urine*
;
Case-Control Studies
;
China/epidemiology*
;
Creatinine
;
Diabetes Mellitus, Type 2/epidemiology*
;
Female
;
Humans
;
Risk Factors
;
Socioeconomic Factors
6.Cost-effectiveness of lung cancer screening worldwide: a systematic review.
C C LIU ; J F SHI ; G X LIU ; W TANG ; X ZHANG ; F LI ; L WANG ; Y MA ; K SU ; S J ZHAO ; Y B GAO ; N LI ; W Q CHEN ; N WU ; M DAI
Chinese Journal of Epidemiology 2019;40(2):218-226
Objective: From the economic point of view, this study was to systematically assess the status quo on lung cancer screening in the world and to provide reference for further research and implementation of the programs, in China. Methods: PubMed, EMbase, The Cochrane Library,CNKI and Wanfang Data were searched to gather papers on studies related to economic evaluation regarding lung cancer screening worldwide, from the inception of studies to June 30(th), 2018. Basic characteristics, methods and main results were extracted. Quality of studies was assessed. Cost were converted to Chinese Yuan under the exchange rates from the World Bank. The ratio of incremental cost-effectiveness ratio (ICER) to local GDP per capita were calculated. Results: A total of 23 studies (only 1 randomized controlled trial) were included and the overall quality was accepted. 22 studies were from the developed countries. Nearly half of the studies (11 studies) took 55 years old as the starting age of the screening program. Smoking history was widely applied for the selection of criteria on target populations (18). Low-dose computed tomography (LDCT) was involved in every study used to evaluate the economic effectiveness. Annual (17) and once-life time (7) screening were more common frequencies. 22 studies reported ICERs for LDCT screening, compared to no screening, of which 17 were less than 3 times local GDP per capita, and were considered as cost-effectiveness, according to the WHO's recommendation. 15 and 7 studies reported ICERs for annual and once-life time screening, of which 12 and 7 studies were in favor the results of their cost-effectiveness, respectively. Additionally, the cost-effectiveness of once-lifetime screening was likely to be superior to the annual screening. Differences of cost-effectiveness among the subgroups, by starting age or by the smoking history, might exist. Conclusions: Based on the studies, evidence from the developed countries demonstrated that LDCT screening programs on lung cancer, implemented among populations selected by age and smoking history, generally appeared more cost-effective. Combined with the local situation of health resource, the findings could provide direction for less developed regions/countries lacking of local evidence. Low frequency of LDCT screening for lung cancer could be adopted when budget was limited. Data on starting ages, smoking history and other important components related to the strategy of screening programs, needs to be precisely evaluated under the situation of local population.
China
;
Cost-Benefit Analysis
;
Early Detection of Cancer/methods*
;
Humans
;
Lung Neoplasms/prevention & control*
;
Middle Aged
;
Quality-Adjusted Life Years
;
Randomized Controlled Trials as Topic
7.Study on the accuracy of oxygen concentration of modified oxygen treatment with Venturi and humidity system.
Qiang WEI ; Bingyu QIN ; Guojun HE ; Yuanyuan WU ; Yuan SHI ; Weitao SUN ; Mengjuan JING ; Shichao ZHU ; Huanzhang SHAO
Chinese Critical Care Medicine 2018;30(7):677-680
OBJECTIVE:
To verify the accuracy of oxygen concentration (FiO2) of modified oxygen treatment with Venturi and humidity system.
METHODS:
Patients just after ventilator weaning and before the removal of tracheal intubation/tracheotomy tube, who admitted to the intensive care unit (ICU) of Henan Provincial People's Hospital from May 1st to December 15th in 2017, were enrolled. All patients were given a modified oxygen treatment with Venturi and humidity system, and the oxygen flow rate (Flow) of the Venturi device and the oretical value of FiO2 were adjusted according to the patient's condition. Patients were divided into five groups based on doctor's orders: Flow 3 L/min FiO2 0.24, Flow 3 L/min FiO2 0.26, Flow 6 L/min FiO2 0.28, Flow 6 L/min FiO2 0.30, Flow 9 L/min FiO2 0.35. The value of FiO2 at the inhalation end of patients of each group was measured by TSI airflow analyzer, and the consistency between the measured value of FiO2 at the inhalation end and the FiO2 marked value of Venturi was compared and analyzed.
RESULTS:
When the FiO2 theoretical value of Venturi were adjusted to 0.24, 0.26, 0.28, 0.30, and 0.35, the measured values of FiO2 at the inhalation end of patients were 0.38±0.05, 0.38±0.05, 0.40±0.04, 0.41±0.04, and 0.77±0.11, respectively, which were all significantly higher than the theoretical value of FiO2 (all P < 0.01). The difference between the measured value of FiO2 at the inhalation side and the FiO2 value of the Venturi annotated and the difference rate were both "V"-shaped, both of which decreased with the increase in theoretical value of FiO2 to a Flow of 9 L/min and a theoretical value of FiO2 0.35, the accuracy was the worst, with the FiO2 difference of 0.42±0.11, and the FiO2 difference rate of (121.6±36.5)%.
CONCLUSIONS
There is a difference between the measured value and the theoretical value of FiO2 at the inhalation end of the modified Venturi oxygen therapy humidification system, which needs to be paid attention to during clinical oxygen therapy.
Humans
;
Humidity
;
Oxygen/analysis*
;
Oxygen Inhalation Therapy
;
Respiration, Artificial
;
Ventilator Weaning
8.Application of miniSTR Loci and Its Detection System for Degraded Materials in Forensic Medicine.
Xin WANG ; W Z CHEN ; J ZHANG ; J H LI ; Y P SUN ; Y J SHI ; L ZHANG ; L L CHEN ; X ZHOU ; R H ZHOU
Journal of Forensic Medicine 2018;34(5):532-537
OBJECTIVES:
To establish multiplex system of 16 miniSTR loci, and explore its application value for the degraded materials in forensic medicine.
METHODS:
The multiplex system of 16 miniSTR loci was established using a six-dye fluorescence labeling technology and its application value in forensic medicine was assessed.
RESULTS:
A six-dye fluorescence labeling miniSTR amplification kit was developed, which enabled 15 autosomal STR loci, Amelogenin locus and DYS391 to be typed simultaneously. This method showed good specificity and could provide stable and accurate typing results with a sensitivity of 50 pg. This system also provided a good test result for the normal biological sample of actual cases.
CONCLUSIONS
The multiplex system of 16 miniSTR loci has application value for degraded and trace materials with the advantages of high sensitivity and database compatibility, which can be used for forensic casework.
Amelogenin
;
DNA Fingerprinting
;
DNA Primers
;
Forensic Medicine/methods*
;
Microsatellite Repeats/genetics*
;
Polymerase Chain Reaction
9.Progress in research of relationship between heavy metal exposure and cardiovascular disease.
F LU ; F ZHAO ; J Y CAI ; L LIU ; X M SHI
Chinese Journal of Epidemiology 2018;39(1):102-106
Heavy metal is one of pollutants existed widely in the environment, its relationship with cardiovascular disease has attracted more and more attention. In this review, the concentrations of heavy metals, including lead, cadium and asenic, in the body from several national surveillance networks and the epidemiological studies on the effects of the exposure of three heavy metals on cardiovascular system were summarized. It is suggested to strengthen nationwide surveillance for body concentrations of heavy metals in general population in order to provide baseline data for quantitative evaluation of the risk of heavy metal exposure on cardiovascular disease.
Cadmium
;
Cardiovascular Diseases/chemically induced*
;
Environmental Exposure/adverse effects*
;
Environmental Pollutants/toxicity*
;
Epidemiologic Studies
;
Humans
;
Lead/toxicity*
;
Metals, Heavy/toxicity*
;
Neoplasms
;
Research/trends*
10.Sustainability of cancer screening program in urban China: a multicenter assessment from service supplier's and demander's perspectives.
Chinese Journal of Epidemiology 2018;39(2):139-141
In a real-world running of cancer screening programs or intervention strategies, multiple influencing factors need to be considered other than the effectiveness and cost-effectiveness. The articles in this special issue summarize the main findings related to sustainability of cancer screening program in urban China from four perspectives of cancer screening service, including actual supplier, potential supplier, actual demander and potential demander. These evidences are expected to provide references for decision-making on suitable strategies and running mechanism for large-scale cancer screening program in local populations.
China
;
Cost-Benefit Analysis
;
Early Detection of Cancer/methods*
;
Health Services Administration
;
Humans
;
Mass Screening/organization & administration*
;
Neoplasms/prevention & control*
;
Urban Population


Result Analysis
Print
Save
E-mail