1.Effect of health education project of a three-year special action for prevention and control of drinking water-borne endemic fluorosis in Shandong Province
Jinming HUANG ; Juan CUI ; Ning WANG ; Chunlei WANG ; Jinwen ZONG ; Kun WANG ; Guangxin WEI ; Xuewen LI
Chinese Journal of Endemiology 2022;41(2):159-163
Objective:To evaluate the effect of health education of a three-year special action for prevention and control of drinking water-borne endemic fluorosis (referred to as drinking water-borne fluorosis) in Shandong Province, and to provide basis for formulating health education measures in the next step.Methods:Nineteen of the disease affected counties (cities and districts) were selected as project counties (cities and districts) in key areas for prevention and control of drinking water-borne fluorosis in Shandong Province in 2018, and 50 disease affected counties (cities and districts) were selected in 2019, and the project counties (cities and districts) were expanded to all of the 105 disease affected counties (cities and districts) in Shandong Province in 2020. Three disease affected townships (towns) were selected in each county (city and district), and health education activities on drinking water-borne fluorosis were carried out in Grade 4 to Grade 6 of the central primary schools and the three villages under its jurisdiction. Students and housewives were selected to conduct questionnaire surveys on prevention and control knowledge of drinking water-borne fluorosis before and after health education. The incidence of dental fluorosis among children aged 8 - 12 years was investigated annually in 6 villages (with children aged 8 - 12 years > 50) , where health education activity was implemented and the incidence of dental fluorosis among children was > 30%, water fluoride content was > 1.5 mg/L and water improvement time was < 5 years.Results:After health education, the awareness rates of drinking water-borne fluorosis in fifth grade pupils [92.46% (4 571/4 944) vs 65.80% (3 334/5 067) in 2018; 94.84% (12 897/13 599) vs 73.55% (9 993/13 587) in 2019; 95.59% (30 407/ 31 809) vs 77.52% (24 463/31 557) in 2020] and housewives [94.12% (2 400/2 550) vs 76.04% (1 939/2 550) in 2018; 94.99% (6 412/6 750) vs 72.00% (4 860/6 750) in 2019; 95.53% (16 183/16 941) vs 78.43% (12 971/16 539) in 2020] were significantly improved (χ 2 = 1 070.47, 2 315.27, 4 456.40, 328.25, 1 294.80, 2 174.63, P < 0.05). After health education in 2020, there were significant differences in the correct answer rates of epidemic causes, hazards and preventive measures of drinking water-borne fluorosis in the questionnaire of fifth grade pupils and housewives (χ 2 = 390.78, 164.94, P < 0.05). The awareness rates of drinking water-borne fluorosis in fifth grade pupils and housewives in the eastern region (Qingdao City, Yantai City and Weifang City) were significantly higher than those in the western region (Dezhou City, Liaocheng City and Heze City) before health education (χ 2 = 547.43, 210.12, P < 0.05), and after health education, the awareness rates increased to more than 90%. The detection rate of dental fluorosis in children decreased year by year (χ 2trend = 27.95, P < 0.05). Conclusions:Through implementation of a three-year special action for prevention and control of drinking water-borne fluorosis in Shandong Province, the awareness rate of fluorosis among target populations has been significantly improved. However, it is still necessary for government departments to further increase investment in health education and carry out health education activities in a deep-going way.
2.Determination of Related Substances in Rifabutin Crude Drug and Capsules by HPLC
Qiuyan YI ; Xuewen CUI ; Jun LUO ; Wenyue LIU ; Jun YUAN
China Pharmacy 2019;30(15):2047-2051
OBJECTIVE: To establish a method for the determination of related substances in rifabutin crude drug and capsules by HPLC. METHODS: HPLC method was adopted. The determination was performed on Agilent XDB-C8 column with mobile phase consisted of acetonitrile-0.1 mol/L potassium dihydrogen phosphate solution (pH 6.5±0.1) (50 ∶ 50, V/V) at the flow rate of 1.0 mL/min. The detection wavelength was set at 254 nm, the column temperature was 30 ℃, and sample size was 20 μL. The mobile phase was used as solvent to prepare the sample solution with a mass concentration of 1.0 mg/mL. The system suitability test was performed by using newly established method and current method (mass concentration of sample solution 0.5 mg/mL, C18 column) stated in quality standard of rifabutin crude drug and capsules. Related substance test was conducted for 6 batches of rifabutin crude drug and capsule (peak area normalization method). RESULTS: The linear range of rifabutin was 0.8-16 μg/mL(r=1.000 0), RSDs of precision, reproducibility and stability tests (12 h) were all lower than 2.0% (n=6); the limits of detection and quantification were 0.025 4, 0.085 2 μg/mL. In system suitability test, by using new method and current method, separation degree of rifabutin peak and pre-degradation product peak were 7.50 and 3.47. When 6 batches of samples were determined, the number of impurities detected by this method was 1-5 more than that by the current method, and the total amount of impurities was 0.19%-0.55% higher. CONCLUSIONS: Established new method is well-separated and sensitive, and can be used for the determination of related substance in rifabutin crude drug and capsules, which helps the quality control of drugs.
3.NovelZero-Pversustitanium plate with cage interbody fixation and fusion system in repairing cervical spondylosis:early stability
Yiqi XU ; Xuesong ZHANG ; Taicun SUN ; Danfeng JING ; Haining CHEN ; Xuewen CUI
Chinese Journal of Tissue Engineering Research 2016;20(22):3227-3234
BACKGROUND:It is notable to treat cervical spondylosis using the anterior cervical discectomy and fusion, but there are such complications as cervical instability and low fusion rate. Titanium plate with cage can solve those defects, while anterior unfamiliar matter and dysphagia appear. A new anterior cervical interbody fusionZero-Pwith support and fixation function has been widely used in clinic.
OBJECTIVE:To analyze early stability in repairing cervical spondylosis using a newZero-Pinterbody fixation and fusion system, and compare with a titanium plate with cage interbody fixation andfusion system.
METHODS:We retrospectively analyzed the clinical date of 31 patients with cervical spondylosis who underwent the anterior cervical discectomy and fusion in the Department of Orthopedics, Affiliated Hospital of Jiangsu University between August 2010 and August 2014. Fifteen patients were treated with aZero-P implant (Zero-Pgroup) and sixteen patients with a titanium plate with cage (cage group). We recorded operation time, intraoperative blood loss, preoperative and postoperative Visual Analogue Scale scores and Japanese Orthopedic Association scores, postoperative incidence of dysphagia and degeneration rate of adjacent joint.
RESULTS AND CONCLUSION:(1) Postoperative symptoms were apparently improved, without severe complications in both groups. (2) Operation time and intraoperative blood loss were better in theZero-P group than in the cage group (P< 0.05). (3) Postoperative Visual Analogue Scale scores and Japanese Orthopedic Association scores were significantly improved in both groups (P< 0.05). The recovery rate of Japanese Orthopedic Association scores was similar between the two groups (81%, 81%;P> 0.05). (4) Mild dysphagia was experienced by one case (7%) in theZero-Pgroup, but nine cases (44%) in the cage group. Significant difference in the incidence of dysphagia was detected between the two groups after treatment (P=0.037). However, no significant difference in degeneration rate was detectable between the two groups (P=0.48). (5) These findings verify that in the anteriorcervical discectomy and fusion, the new Zero-Pand titanium plate with cage interbody fixation and fusion system are effective choices for cervical spondylosis. However, theZero-Pinterbody fixation and fusion system showed a low incidence of postoperative dysphagia and better stability.
4.Effectiveness of arthroscopic treatment of anterior cruciate ligament tibial eminence avulsion fracture with suture bridge fixation technique
Yingchun ZHU ; Xuewen JIA ; Zheyang WANG ; Cui WANG ; Zhanping JIN
China Journal of Endoscopy 2016;22(7):106-110
Objective To evaluate the technique and clinical effect of arthroscopic treatment of anterior cruciate ligament tibial eminence avulsion fracture with suture bridge fixation technique. Methods From May 2013 to July 2015, 18 patients with anterior cruciate ligament tibial eminence avulsion fracture were treated with arthroscopic re﹣duction and fixation by suture bridge technique. There were 12 males and 6 females with an average age of 29.8 years old (range, 9~45 years). The right knees were involved in 10 cases and left knees in 8 cases. The injury caus﹣es included traffic accident injury in 10 cases, sports injury in 5 cases and other reasons in 3 cases. 2 patients had old fracture, the others had fresh fracture. The results of Lachman and anterior drawer test were both positive. The International Knee Documentation Committee (IKDC) subject score was (53.8 ± 4.2). Based on Meyers-Mckeaver classification, there were 5 cases in typeⅡ, 10 cases in type Ⅲ and 3 cases in type Ⅳ. Results The operation time was 50~80 minutes (mean, 60.5 minutes), X-ray showed satisfactory fracture reduction after surgery. Primary healing of incision were obtained with no infection, all 18 patients were followed up for 6 ~ 31 months (mean, 18.6 months). The results of Lachman and anterior drawer test were both negative in 17 cases, the result was negative for anterior drawer test and was weakly positive for Lachamn test in 1 case. The IKDC subject score were significantly improved to (95.2 ± 3.8) at last follow-up (P< 0.05). Conclusion It could achieve early restoration of knee joint function to treat the anterior cruciate ligament tibial eminence avulsion fracture with suture bridge fixation technique because of satisfactory reduction, reliable fixation, minor trauma, and quick recovery.
5.An Analysis of Auditory Brainstem Response in Autistic Children of 6 Years or Younger
Xuewen WU ; Mingyu LIU ; Fengjun WANG ; Xiaojing LU ; Xiangning CUI ; Hongsheng CHEN ; Yong FENG
Journal of Audiology and Speech Pathology 2015;(5):466-469
Objective To investigate the characteristics of auditory brainstem response (ABR) in autistic children of 6 years or younger .Methods A total of 98 children with normal hearing and 22 autistic children were en‐rolled in this study .They were divided into 3 groups :1~2 years age group ,2< ~3 years age group ,and 3< ~6 years age group .The thresholds ,wave latencies and interpeak intervals of ABR were statistically analyzed .Results The ABR thresholds in normal hearing children (and autistic children) in 1~2 years age group ,2< ~3 years age group ,and 3< ~6 years age group were 15 .64 ± 5 .02 (17 .50 ± 5 .35) ,14 .73 ± 4 .85 (17 .81 ± 6 .58) ,and 15 .57 ± 5 .62 (17 .25 ± 6 .97) dB nHL ,respectively .There were no significantly statistical difference between the normal hearing children and autistic children (P>0 .05) .In 80 dB nHL click sound stimulus ,there was also no statistical difference in the values of peak latencies or interpeak intervals of ABR between normal hearing children and autistic children (P> 0 .05) ,whereas ,prolongation of peak latencies or interpeak intervals of ABR occurred in 36 .36%(25 .00% ears) autistic children .The ratio of prolongation of peak latencies of I ,III ,V waves and interpeak inter‐vals of I-III ,III-V ,I-V occurred in 4 .54% ,6 .82% ,13 .64% ,18 .18% ,6 .83% and 15 .91% ,respectively . Conclusion The ABR in some autistic children present abnormality and occur in various forms with the prolongation of interpeak intervals of I -III as the most common .
6.Polymethylmethacrylate augmentation of a cannulated and fenestrated pedicle screw for lumbar degenerative disease accompanied with osteoporosis:strengthening technical points
Danfeng JING ; Yiji XU ; Taicun SUN ; Jin TIAN ; Biao LU ; Xuewen CUI
Chinese Journal of Tissue Engineering Research 2014;(47):7556-7560
BACKGROUND:Once lumbar degenerative diseases merge with lumbar spinal stenosis, lumbar instability and degenerative scoliosis, surgical therapy is required for corresponding clinical symptoms, and the usage of internal fixators cannot be inevitable. Osteoporosis is rather common in the elderly. Therefore, how to implant stable pedicle screw fixation system in serious osteoporosis patients wil be a big difficulty. In recent years, some studies have proven the biomechanical stability of polymethylmethacrylate augmentation of a cannulated and fenestrated pedicle screw in the vertebral body, so it becomes very hot in the spine surgery. OBJECTIVE: To explore the clinical efficacy of the use of polymethylmethacrylate augmentation of a cannulated and fenestrated pedicle screw fixation for the treatment of lumbar degenerative disease accompanied with osteoporosis. METHODS:Thirty-one patients with lumbar degenerative disease accompanied with osteoporosis from Jun 2008 to Jan 2013 were selected, including 11 males and 20 females with an average age of 73.5 years (range, 65-86 years). There were 14 cases of lumbar degenerative stenosis, 9 of lumbar intervertebral disc herniation combined with segmental instability, 6 of lumbar degenerative spondylolisthesis, and 2 of lumbar degenerative scoliosis. The patients were treated with lumbar canal decompression, fusion and polymethylmethacrylate augmentation of a cannulated and fenestrated pedicle screw fixation according to their clinical features and imaging data. Visual analog scale for pain evaluation was used before and after fixation, the Japanese Orthopaedic Association (JOA) scale was used for assessment of neurological function and life skils before internal fixation and during folow-up. RESULTS AND CONCLUSION:Al cases were folowed up for 40 months (range, 36-48months). No screw breakage, rod breakage, screw extraction, loosening, pseudoarticulation formation, or incision infection was found. The postoperative visual analog scale score and the JOA score was remarkably improved (P < 0.05). For patients suffering from lumbar degenerative disease accompanied with osteoporosis, polymethylmethacrylate augmentation of a cannulated and fenestrated pedicle screw fixation is helpful for increasing the stabilization of screw and preventing from loosening and dislocation of the screws, and thereby beneficial for improvement and maintenance of clinical efficacy.
7.Audiological Analysis of Patients with Intact Tympanic Membranes and Conductive or Mixed Hearing Loss
Xuewen WU ; Yong FENG ; Fengjun WANG ; Lingyun MEI ; Chufeng HE ; Xiaojing LU ; Xiangning CUI ; Hongsheng CHEN
Journal of Audiology and Speech Pathology 2014;(5):468-470
Objective To investigate audiological characteristics of patients with intact tympanic membranes and conductive or mixed hearing loss .Methods A retrospective study was carried out among 30 patients (42 ears) with intact tympanic membranes and conductive or mixed hearing loss who underwent exploratory tympanotomy . The preoperative outcomes of pure tone audiometry ,tympanometry ,resonant frequency of middle ear and temporal bone CT scan were analyzed .Results Among 42 ears ,30 ears with otosclerosis and 12 ears with ossicular chain dis-ruption were confirmed in exploratory tympanotomy ,but only 5 ears showed positive findings in CT scan .The mean thresholds of bone conduction ,air conduction and air -bone gap at frequencies of 0 .5 ,1 and 2 kHz were 27 .5 ± 1 .3 dB HL ,67 .0 ± 1 .8 dB HL ,39 .5 ± 1 .1 dB HL ,respectively .An analysis of tympanometric data of all patients re-vealed that 50% of all ears (21/42) were type A tympanograms ,42 .9% (18/42) were type As tympanograms ,and 7 .1% (3/42) were type Ad tympanograms .The mean of the resonant frequency of the middle ear in otosclerositic patients (1 079 .0 ± 67 .4 Hz) was significantly higher than ossicular chain disruption patients (633 .3 ± 43 .6 Hz) . Conclusion Otosclerosis is the most common in the patients with intact tympanic membranes and conductive or mixed hearing loss .The middle ear resonant frequency of otosclerositic patients is significantly higher than that of ossicular chain disruption patients .
8.Preparation of a gear distraction plate device for spinal reduction and fixation
Xuewen CUI ; Jin TIAN ; Liang DING ; Shuhong Lü
Chinese Journal of Tissue Engineering Research 2010;14(48):9109-9112
BACKGROUND: The most commonly used rod-screw posterior spinal fixation system has some biomechanical drawbacks. The screw-plate system is more preferred for patients.OBJECTIVE: To prepare a new posterior spinal fixation system based on imaging results of distance between two pedicles,radian of spine flexion, extension and the height of intervertebral space of Chinese population.METHODS: The thoracolumbar data of 129 normal people were measured. According to the imaging measurements and relative documents, a device of gear-distraction plate (GDP) for spine reduction and fixation was designed. Eighteen fresh calf lumbar specimens were randomly divided into 3 groups, the test group was fixed by GDP and the other groups were fixed by CD and Steffee plate, respectively. The results of the displacement, strain, strength, stiffness and ultimate strength were measured under the states of vertical compression, flexion, extension and lateral bending respectively, and the results were statistically analyzed.RESULTS AND CONCLUSION: GDP could meet the need of strength and stiffness of human bodies. It showed superior to the CD and Steffee plate groups in strength and stiffness (P < 0.05), with 13% or 14% torsion intensity greater than that of the CD or Steffee plate groups. The ultimate mechanical performance test showed that, the load bearing of the GDP group was greater than that of the CD and Steffee plate groups (P < 0.05). The findings demonstrated that GDP for Chinese human presented with good biomechanical stability, which can promote vertebrae fracture union and prevent kyphosis relapses or vertebral height loses.
9.Transvaginal Contrast-enhanced Sonography in the Differentiation of Benign from Malignant Adnexal Masses
Junyan WANG ; Qiuli CUI ; Aijun LIU ; Xuewen GAO ; Longxia WANG ; Li SU ; Yuanqing YAO ; Enfeng ZHAO ; Xiuli LI ; Weiping LI ; Hong XU ; Zhixian YUAN ; Qian LIN
Chinese Journal of Medical Imaging 2009;(6):412-415
Purpose:The study was designed to investigate the feasibility of contrast-enhanced ultrasound in the differentiation of benign and malignant adnexal masses.Materials and Methods:Sixty-nine consecutive patients with adnexal masses received trans vaginal contrast-enhanced ultrasound.The image and perfusion features were assessed.Results:All of 26 malignant tumors showed detectable contrast enhancement,including 24 cases with a quick,heterogeneous or branching pattern.Among 39 benign lesions,24 were cystic with circle or half-circle enhancement,including 5 cases with intra-cystic septum or papillae slightly enhanced.The other 15 cases were solid,8 of them had slightly dotted enhancement.There are significant difference in enhancement patterns between benign and malignant masses ( P < 0.0001).The 4 cases of borderline tumors showed progressive,heterogeneous enhancement.Conclusion:Contrast-enhanced ultrasound is of value in the differentiation of benign and malignant adnexal masses.
10.Custom-made tumor prosthesis replacement for the treatment of malignant tumors around the knee
Xuewen CUI ; Xiaofeng XU ; Xin PAN ; Jin TIAN ; Jun ZHANG ; Xingbing CAO
Chinese Journal of Tissue Engineering Research 2009;13(48):9555-9558
OBJECTIVE: To explore the clinical effects of using custom-made tumor prosthesis replacement to treat malignant tumor located in the distal femur or proximal tibia. METHODS: A retrospective study of 29 cases malignant tumors around knee treated surgically from June 2001 to October 2008. In the study there were 19 males and 10 females, aging from 17 to 65 years, with an average of 38.5 years. The location of tumors was at distal femur in 22 cases and 7 cases at proximal tibia. After the tumor was extensively resected or radically resected, custom-made tumor prosthesis replacement was performed for reconstruction, simultaneously, neoadjuvant chemotherapy and radioactive-therapy were used in treating the tumor according the pathology. RESULTS: All patients were followed-up for 18-84 months, with average follow-up period of 54.2 months. The 3 year survival rate was 79.8%, and the 5 year survival rate was 63%. As for the complications, prosthesis breakage occurred in 2 patients, aseptic loosening in 1 patients, 2 had a recurrence of the soft tissue tumor for which the diseased limb amputation was performed. The mean MSTS score showed excellent limb function in 15 patients, good in 8 patients, fair in 5 patients and poor in 1 patient. The overall excellent and good function was obtained in 79% of the patients. No superficial or deep infection occurred. Two patients suffered common peroneal nerve injury, but were cured by symptomatic treatments. CONCLUSION: Application of tumor prosthesis can give a satisfactory functional outcome, which is an effect method in limb salvage treatment of malignant tumor around the knee.

Result Analysis
Print
Save
E-mail