1.The relationship between serum c-kit mRNA level and myocardial fibrosis,cardiac function and prognosis in patients with dilated cardiomyopathy complicated with heart failure
Zhanwei ZHANG ; Jun ZHANG ; Xuemei XING ; Song WU ; Huan TIAN
International Journal of Laboratory Medicine 2024;45(6):641-646
		                        		
		                        			
		                        			Objective To investigate the relationship between serum stem cell factor receptor(c-kit)and myocardial fibrosis,cardiac function and prognosis in patients with dilated cardiomyopathy(DCM)complicat-ed with heart failure.Methods A total of 77 patients with DCM complicated with heart failure who were trea-ted in 3201 Hospital from May 2020 to June 2022 were enrolled in the study as study group,and 70 DCM pa-tients without heart failure were enrolled as the control group.The levels of serum c-kit mRNA and three my-ocardial fibrosis markers[α-smooth muscle actin(α-SMA),collagen type Ⅰ and collagen type Ⅲ]were detec-ted in the two groups.Cardiac function parameters were obtained by echocardiography.The relationship be-tween serum c-kit mRNA level and myocardial fibrosis and cardiac function was analyzed.According to the oc-currence of major adverse cardiovascular events(MACE),the patients were divided into poor prognosis group and good prognosis group.Multivariate Logistic regression analysis was used to analyze the factors affecting the prognosis of DCM patients complicated with heart failure.Receiver operating characteristic(ROC)curve was used to analyze the efficacy of serum c-kit mRNA level in predicting the prognosis of DCM patients.Results The serum c-kit mRNA level in the study group was lower than that in the control group(P<0.05).The levels of three myocardial fibrosis indicators in the study group were higher than those in the con-trol group(P<0.05).The left ventricular ejection fraction(LVEF)in the study group was lower than that in the control group(P<0.05),and the left ventricular end-diastolic volume(LVEDV)and left ventricular end-systolic volume(LVESV)in the study group were higher than those in the control group(P<0.05).Pearson correlation analysis showed that serum c-kit mRNA level was positively correlated with LVEF(r=0.677,P<0.05),while negatively correlated with α-SMA,collagen type Ⅰ,collagen type Ⅲ,LVEDV and LVESV(r=-0.725,-0.748,-0.744,-0.745,-0.662,P<0.05).Multivariate Logistic regression analysis showed that serum c-kit mRNA level is an independent factor for the prognosis of DCM patients with heart failure.ROC curve analysis showed that serum c-kit mRNA level had a sensitivity of 82.80%,a specificity of 81.80%,and an area under the curve of 0.829(95%CI:0.745-0.912,P<0.001)for evaluating the progno-sis of DCM patients complicated with heart failure.Conclusion The serum c-kit mRNA level is significantly decreased in patients with DCM complicated with heart failure,and the serum c-kit mRNA level is correlated with myocardial fibrosis and cardiac function.The detection of serum c-kit mRNA level has a high efficacy in evaluating the prognosis of patients with DCM complicated with heart failure.
		                        		
		                        		
		                        		
		                        	
2.Bibliometric analysis on research about low-level occupational benzene exposure
Danping DUAN ; Shuzhen BAI ; Yingyin LIU ; Luxi BAI ; Jinmei LIANG ; Ling ZHU ; Lin CHEN ; Huidong SONG ; Xuemei CHEN ; Zhi WANG
China Occupational Medicine 2024;51(2):199-204
		                        		
		                        			
		                        			ObjectiveTo analyze the research status and trends in low-level occupational benzene exposure. Methods Articles on low-level occupational benzene exposure from Chinese and English journals from January 1st, 2000, to December 31th, 2022 were retrieved using the Web of Science and the China National Knowledge Infrastructure, and a bibliometric analysis was conducted. Results A total of 327 articles were included in the analysis, comprising 216 English articles and 111 Chinese articles. i) The number of articles published in English fluctuates greatly over the years, without a trend of continuous growth or decline. Authors from 359 research institutions in 45 countries and regions have published relevant English articles in 97 kinds of journals, involving 281 grants from 226 foundations. The top three countries in terms of articles amount were the United States, Italy, and China, with 81, 46, and 43 papers, respectively. The English articles mainly focused on mechanistic research at the genetic level, such as hematotoxicity, oxidative stress, and DNA damage. ii) The number of Chinese articles increased gradually after 2012, with the growth peak in 2017. Authors from 127 research institutions in 26 provinces, autonomous regions, and municipalities published Chinese articles in 51 kinds of journals, involving 154 grants from 78 foundations. Chinese articles tended to focus on benzene-induced hematotoxicity and occupational health damage. Conclusion Most studies on low-level occupational benzene exposure were conducted in China, the United States and Italy, focused on hematotoxicity. Monitoring international research topics and hotspots of the field has certain reference value for related research in China. 
		                        		
		                        		
		                        		
		                        	
3.Genetic factors, risk factors and pathogenesis of cerebral palsy comorbid epilepsy
Chao GONG ; Beibei LIAN ; Xuemei LI ; Peng ZHANG ; Fanxu SONG ; Jin GUO
Chinese Journal of Child Health Care 2024;32(2):174-180
		                        		
		                        			
		                        			Compared to the general population, there is a higher prevalence of epilepsy in individuals with cerebral palsy (CP). Epilepsy serves as an indicator of CP severity and has a significant impact on the early survival and future quality of life of children with CP. Therefore, it is crucial to investigate the shared mechanisms underlying CP and epilepsy. This study aims to summarize the comorbidity of CP and epilepsy from genetic factors, risk factors, and pathophysiological mechanisms, in order to provide a reference for further research.
		                        		
		                        		
		                        		
		                        	
4.Neuro-ophthalmic features of SARS-CoV-2 associated acute macular neuroretinopathy
Pei LIU ; Zhaojie CHU ; Bo LI ; Xuemei LIN ; Yan LIU ; Chensheng SONG ; Yan SUO ; Jun ZHAO ; Songdi WU
International Eye Science 2024;24(7):1173-1178
		                        		
		                        			
		                        			 AIM: To explore the neuro-ophthalmological characteristics of acute macular neuroretinopathy(AMN)after SARS-CoV-2 infection.METHODS: A total of 8 patients(14 eyes), including 6 females and 2 males, who were diagnosed with AMN in the neuro-ophthalmology department of Xi'an No.1 Hospital(The First Affiliated Hospital of Northwest University)from December 27, 2022 to February 1, 2023 were included in the study. All patients had a history of SARS-CoV-2 infection before the disease, and the results of best corrected visual acuity(BCVA), non-contact indirect intraocular pressure measurement, fundus color photography, near infrared(IR), spectral-domain optical coherence tomography(SD-OCT), OCT angiography(OCTA), fundus fluorescein angiography(FFA), indocyanine green angiography(ICGA), visual field, visual evoked potential(VEP), and electroretinogram(ERG)were collected. Furthermore, the neuro-opthalmology characteristics of the included patients were analyzed and summarized.RESULTS: The included 8 patients aged from 20 to 43, with an average age of(30±6.63)years old. The patients had a history of SARS-CoV-2 infection 3 to 11(mean 5±3.51)d before the disease, and 6 out of 8 patients developed visual symptoms within 5 d of infection with SARS-CoV-2, with manifestated with decreased vision or visual scotoma. The visual acuity varied from 0.08 to 1.0, with visual field defect characterized by central, paracentral or peripheral scotoma. VEP showed prolongation latency of P100 or P2, and ERG revealed impaired function of retinal photoreceptor cell. In the early stage of the disease, the size and shape of early visual acuity, visual field, and extraretinal lesions in patients with AMN associated with SARS-CoV-2 infection may not match, and the lower the visual acuity, the later the VEP peaks.CONCLUSION: The neuro-ophthalmic features of SARS-CoV-2 infection-associated AMN require the attention of clinicians. In addition to multi-mode fundus imaging, clinicians should use a variety of methods to comprehensively evaluate visual function and prognosis of patients. 
		                        		
		                        		
		                        		
		                        	
5.Effects of Houttuynize Herba on IκBα/NF-κB signaling pathway by regulating intestinal flora in mice with gastric ulcer
Xinchen SONG ; Haiyan WANG ; Guoli CUI ; Xuemei MA ; Binjian ZHOU ; Qingtian WU
International Journal of Traditional Chinese Medicine 2024;46(12):1593-1600
		                        		
		                        			
		                        			Objective:To investigate the effects of Houttuynize Herba decoction on aspirin-induced gastric ulcer (GU) in mice; To discuss its mechanism.Methods:A total of 64 SPF male mice were selected, and 48 mice were randomly selected to establish the model by gavage of 20 mg/ml aspirin solution. The remaining 16 rats were treated as normal group by gavage with the same amount of normalsaline once a day for 7 consecutive days. After successful modeling, the remaining mice in the model group were randomly divided into 5 groups, with 8 mice in each group, namely normal saline group (given normal saline), omeprazole group (given omeprazole 0.5 mg/ml), Houttuynize Herba high-, medium- and low-dosage groups (given 1.08 g/ml, 0.54 g/ml, 0.27 g/ml), and the remaining 8 mice in the normal group were given the same amount of normal saline by gavage. The mice were treated by gavage once a day for 7 days. The number of Escherichia coli and Bifidobacterium in mouse feces was counted by bacterial culture method, and the ratio of Bifidobacterium to Escherichia coli (B/E value) was used to judge the imbalance of bacterial flora. The expression of interleukin-6 (IL-6) in serum was detected by magnetic particle chemiluminescence. Enzyme-linked immunosorbent assay (ELISA) was used to detect the expression of prostaglandin E 2 (PGE 2) in the serum of mice to determine the level of inflammation. Hematoxylin-eosin staining was used to determine the ulcer and healing. ImageJ 1.8.0 was used to calculate the ulcer inhibition rate. The protein expression levels of IκBα, NF-κB-p65 subunit and phosphorylated IκBα (p-IκBα) and p65 (p-NF-κB-p65) subunits in gastric tissue of mice were evaluated by Western blot. Results:Compared with the normal group, the epithelial cells of the gastric mucosa were missing, the glands were irregularly arranged, and the tissue structure was severely damaged in the modeling group; the number of Escherichia coli in the intestine increased ( P<0.01), the number of Bifidobacterium decreased ( P<0.01), and the B/E value was less than 1 ( P<0.01); Serum PGE2 levels were decreased ( P<0.01), IL-6 levels were increased ( P<0.01); The expression of p-IκBα and p-NF-κB-p65 proteins in gastric tissues was elevated ( P<0.05). After 7 days of drug treatment, compared with the saline group, gastric mucosal cells and structures were improved, and weight gained in the Houttuynize Herba groups ( P<0.05); the rate of inhibition of ulcers in mice in the Houttuynize Herba high-dosage group was significantly improved ( P<0.01); the number of Bifidobacteria in the intestinal tract significantly increased ( P<0.01), that of Escherichia coli was diminished ( P<0.05), B/E value was greater than 1 ( P<0.05), IL-6 content in peripheral blood was reduced ( P<0.05), PGE 2 levels significantly increased ( P<0.01); the level of p-IκBα/IκBα and p-NF-κB-p65/NF-κB-p65 in the gastric tissues of mice decreased ( P<0.01). Conclusion:Houttuynize Herba decoction can effectively improve gastric mucosal injury in mice, and its mechanism may be related to regulating intestinal microorganisms, inhibiting the opening of IκBα/NF-κB pathway, and reducing inflammatory response.
		                        		
		                        		
		                        		
		                        	
6.Study of the relationship between the ultrasound parameters of reproductive system and the expression of endocrine hormone in female pediatric patients with precocious puberty,and the assessment of treatment effect
Yiyong ZHAO ; Peng YIN ; Pengfei ZHU ; Baoli SONG ; Xuemei CHEN ; Weidong NI
China Medical Equipment 2024;21(5):92-97
		                        		
		                        			
		                        			Objective:To explore the relationship between the ultrasound parameters of reproductive system and the expression of endocrine hormone in female pediatric patients with precocious puberty(PP),and to assess the treatment effect.Methods:A total of 160 female pediatric patients with PP who admitted to Beijing Jingmei Group General Hospital from January 2021 to December 2021 were selected,and they were divided into a positive group and a normal group based on the diagnostic criteria for precocious puberty,with 80 cases in each group.Ultrasound examination was performed on the uterus,ovaries and breasts of 160 female pediatric patients with PP,and the relevant parameters of them were measured,and the levels of endocrine hormone in the serums of them were detected.The pediatric patients of positive group underwent again the ultrasound examination and the detection of endocrine hormone after they completed treatment.The differences of ultrasound parameters and endocrine hormone between two groups were compared,and the correlation of ultrasound parameters and endocrine hormone between two groups were analyzed,as well as the influence factors of treatment effect.Results:The length and thickness of the uterus,the ratio of the length of the uterus to the length of cervix,the thickness of the endometrium,the size of the ovaries,the number of follicles,and the width and thickness of the hypoechoic area of the breast in the positive group were significantly larger than them in the normal group,and the differences of them were statistical significance(t=16.8,12.6,12.4,14.7,11.5,15.8,10.9,10.2,P<0.05),respectively.The resistance index(RI)of uterine artery of positive group was significantly smaller than that of normal group,and the difference was statistically significant(t=-7.9,P<0.05).The serum estradiol(E2),gonadotropin(GnRH),follicle-stimulating hormone(FSH),luteinizing hormone(LH),progesterone(P)and growth hormone(GH)levels of positive group were significantly higher than those of normal group,and the differences of them were significant(t=20.6,19.8,15.4,17.6,15.2,8.9,P<0.05),respectively.After treatment,the above-mentioned ultrasound parameters and endocrine hormone levels of the pediatric patients in the positive group were significantly improved.The relevant analysis showed that ultrasound parameters were positively correlated with levels of endocrine hormone,and they were important influence factor on the levels of endocrine hormone.In addition,the treatment effect was related to ultrasound parameters(OR=0.78-1.28,P<0.05),the levels of endocrine hormone(OR=0.73-0.77,P<0.05),age,height,weight and BMI(OR=0.70-0.72,P<0.05).Conclusion:The ultrasound parameters of the reproductive system of female pediatric patients with PP are closely related to the expression of endocrine hormones.The levels of endocrine hormones can be used as important indicators of the disease condition and prognosis of female pediatric patients with PP.
		                        		
		                        		
		                        		
		                        	
7.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
		                        		
		                        			
		                        			【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
		                        		
		                        		
		                        		
		                        	
8.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
		                        		
		                        			
		                        			【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
		                        		
		                        		
		                        		
		                        	
9.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
		                        		
		                        			
		                        			【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
		                        		
		                        		
		                        		
		                        	
10.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
		                        		
		                        			
		                        			【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail