1.Clinical observation of 450 nm blue laser vaporization for the treatment of benign prostatic hyperplasia in frail elderly patients
Guowei CHEN ; Zunke XIE ; Lei SHI ; Xuejing GUO ; Zhe JIN ; Lianchao JIN
Journal of Modern Urology 2025;30(6):508-512
Objective: To investigate the clinical efficacy of transurethral 450 nm blue laser vaporization of prostate (BVP) and transurethral plasmakinetic resection of the prostate (PKRP) in the treatment of frail elderly patients with benign prostatic hyperplasia (BPH). Methods: A retrospective analysis was conducted on the clinical data of 62 frail elderly BPH patients undergoing BVP (n=32) or PKRP (n=30) in our hospital during Jan.2023 and Jun.2024.The two groups were compared in terms of postoperative hemoglobin drop, operation time, hospital stay, catheter indwelling time, bladder irrigation time, preoperative and postoperative 3-month postvoid residual (PVR), maximum urinary flow rate (Qmax), international prostate symptom score (IPSS), quality of life score (QoL), and postoperative complications. Results: The postoperative hemoglobin drop was lower in the BVP group than in the PKRP group [(1.62±1.04) g/L vs.(7.37±2.37) g/L, P<0.001].The operation time [(24.53±7.52) min vs. (47.77±11.12) min], hospital stay [(2.78±1.62) d vs. (8.13±0.82) d], catheter indwelling time [(1.84±0.99) d vs. (5.40±0.81) d], and bladder irrigation time [(7.37±2.35) h vs. (51.60±19.72) h] were significantly shorter in the BVP group than in the PKRP group (all P<0.001).At 3 months postoperatively, both groups showed significant improvements in IPSS, QoL, Qmax, and PVR compared to preoperative levels (P<0.05), but there were no significant differences between the two groups (P>0.05).The overall incidence of early postoperative complications in the BVP group was lower than that in PKRP group (18.75% vs. 43.33%, P<0.05).After 3 months of follow-up, there was no significant difference in the incidence of complications between the BVP group and PKRP group(3.13% vs. 13.33%, P=0.14). Conclusion: BVP for the treatment of frail elderly BPH patients is safe and reliable, associated with minimal bleeding, short operation time, catheterization time and hospital stay, and there is no need to discontinue anticoagulant drugs.
2.Clinical and pathological features of 52 patients with glomerulonephritis with dominant C3
Jinying WEI ; Yao HUANG ; Shuguang YUAN ; Xiaojun CHEN ; Xiao FU ; Zheng LI ; Ying LI ; Lin SUN ; Hong LIU ; Xuejing ZHU
Journal of Central South University(Medical Sciences) 2024;49(1):75-83
Objective:With the in-depth study of complement dysregulation,glomerulonephritis with dominant C3 has received increasing attention,with a variety of pathologic types and large differences in symptoms and prognosis between pathologic types.This study analyzes the clinical,pathological,and prognostic characteristics of different pathological types of glomerulonephritis with dominant C3,aiming to avoid misdiagnosis and missed diagnoses. Methods:The clinical,pathological,and follow-up data of 52 patients diagnosed as glomerulonephritis with dominant C3 by renal biopsy from June 2013 to October 2022 were retrospectively analyzed.According to the clinical feature and results of pathology,15 patients with post-infectious glomerulonephritis(PIGN)and 37 patients with of non-infectious glomerulonephritis(N-PIGN)were classified.N-PIGN subgroup analysis was performed,and 16 patients were assigned into a C3-alone-deposition group and 21 in a C3-dominant-deposition group,or 27 in a C3 glomerulopathy(C3G)group and 10 in a non-C3 nephropathy(N-C3G)group. Results:The PIGN group had lower creatinine values(84.60 μmol/L vs 179.62 μmol/L,P= 0.001),lower complement C3 values(0.36 g/L vs 0.74 g/L,P<0.001)at biopsy,and less severe pathological chronic lesions compared with the N-PIGN group.In the N-PIGN subgroup analysis,the C3-dominant-deposition group had higher creatinine values(235.30 μmol/L vs 106.70 μmol/L,P=0.004)and higher 24-hour urine protein values(4 025.62 mg vs 1 981.11 mg,P=0.037)than the C3-alone-deposition group.The prognosis of kidney in the PIGN group(P=0.049),the C3-alone-deposition group(P=0.017),and the C3G group(P=0.018)was better than that in the N-PIGN group,the C3-dominant-deposition group,and the N-C3G group,respectively. Conclusion:Glomerulonephritis with dominant C3 covers a variety of pathological types,and PIGN needs to be excluded before diagnosing C3G because of considerable overlap with atypical PIGN and C3G;in addition,the deposition of C1q complement under fluorescence microscope may indicate poor renal prognosis,and relevant diagnosis,treatment,and follow-up should be strengthened.
3.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
4.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
5.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
6.Experience of lactation mastitis patients: a qualitative study
Jingjin XU ; Ling TANG ; Dongpan FAN ; Hong CHEN ; Xuejing LI ; Ye LI ; Jiaji LI
Chinese Journal of Modern Nursing 2024;30(1):14-20
Objective:To deeply explore the experience of lactation mastitis women, so as to provide a basis for formulating reasonable support measures.Methods:This study was a qualitative study. From November to December 2022, purposive sampling was used to select 13 patients with lactation mastitis who visited the Breast Specialist Nursing Clinic of Dongfang Hospital, Beijing University of Chinese Medicine as the research subject. This study used semi-structured interviews to collect data, and applied the Colaizzi 7-step analysis method to analyze, summarize, and extract themes.Results:The experience of lactation mastitis patients were mainly summarized as self-emotional experience and interpersonal relationship experience. Self-emotional experiences included feelings of anxiety, stress, helplessness, and self-blame. Interpersonal relationship experiences consisted of feelings of helplessness, useless, decision-making difficulties, desire for help and understanding.Conclusions:Lactation mastitis patients face various negative psychological experiences and burdens. Medical and nursing staff, family caregivers, and society should jointly pay attention to the patients' feelings and provide targeted support measures.
7.Application of CT pulmonary angiography in acute pulmonary embolism and right heart function
Hongxia ZHANG ; Xinying CONG ; Tian ZHANG ; Ye WU ; Qing LI ; Xuejing LI ; Yifan CHEN ; Xiuting WANG ; Weiyong YU ; Zhenbo CHEN
Chinese Journal of Rehabilitation Theory and Practice 2023;29(12):1429-1438
ObjectiveTo explore the application value of CT pulmonary angiography (CTPA) in assessing the severity of acute pulmonary embolism (APE) and right heart function in rehabilitation patients. MethodsFrom January, 2013 to January, 2020, 133 inpatients (94 positive and 39 negative) who underwent CTPA examination in Beijing Bo'ai Hospital were involved. Positive patients were further divided into mild, moderate and severe groups based on the pulmonary artery obstruction index (PAOI). The clinical parameters and right heart function indicators were compared. Spearman correlation analysis was used to analyze the correlation between PAOI, and clinical parameters and right heart function indicators, and Logistic regression analysis was used to predict the risk factors of APE. ResultsThere was significant difference in lower extremity venous thrombosis, D-dimer, oxygen partial pressure, PAOI and left process of interventricular septum among four groups (H ≥ 12.350, P < 0.01). PAOI was moderately positively correlated with D-dimer (r = 0.443, P < 0.001) and left process of interventricular septum (r = 0.520, P < 0.001), and was weakly positively correlated with lower extremity venous thrombosis (r = 0.399, P < 0.001), left pulmonary artery diameter (r = 0.213, P = 0.014) and inferior vena cava regurgitation (r = 0.229, P = 0.008). Lower extremity venous thrombosis (OR = 7.708, P < 0.001) and left process of interventricular septum (OR = 3.641, P = 0.008) were independent risk factors for the onset of APE. The combination of the two indicators was effective for diagnosis of APE, and AUC was 0.795 (95% CI 0.715 to 0.874). ConclusionCTPA may be applied to evaluate the severity of APE and right heart function in rehabilitation patients.
8.Apolipoprotein B and ischemic stroke
Xuejing YIN ; Zhichao FENG ; Sujie ZHU ; Caixia YIN ; Lifang ZHANG ; Lihua BAO ; Jinhua CHEN
International Journal of Cerebrovascular Diseases 2022;30(9):700-705
Studies have shown that plasma apolipoprotein B (ApoB) has a good predictive value for ischemic stroke and plays an important role in the prevention and treatment of ischemic stroke. More and more guidelines and consensus opinions began to recommend ApoB as a routine intervention target. This article reviews the biological characteristics, clinical detection advantages, and role and treatment prospect of ApoB in the prevention and treatment of ischemic stroke.
9.Prokaryotic expression of the GapC protein of Streptococcus uberis and prediction, identification of its B-cell epitopes.
Hanqing WANG ; Xuejing ZHANG ; Huan ZHANG ; Xiaomeng CHEN ; Baojiang ZHANG ; Yan SU
Chinese Journal of Biotechnology 2022;38(1):148-159
The GapC protein of Streptococcus uberis located on the surface of bacteria is a protein with glyceraldehyde-3-phosphate dehydrogenase activity. It participates in cellular processes and exhibits a variety of biological activities. In addition, it has good antigenicity. The aim of this study was to predict the possible B-cell epitopes of the GapC protein and verify the immunogenicity of candidate epitope peptides. The gapC gene of S. uberis isolate RF5-1 was cloned into a recombinant expression plasmid pET-28a-GapC and inducibly expressed. The purified protein was used to immunize experimental rabbits to produce anti-GapC polyclonal antibodies. The three-dimensional structure and three-dimensional location of the GapC B-cell epitopes and the homology comparison of the GapC protein and its B-cell epitopes were carried out using bioinformatics softwares. The results showed that the 44-kDa GapC protein had a good immunological reactivity. Six linear and 3 conformational dominant B-cell epitopes against the GapC protein were selected and synthesized. Three dimensional analysis indicated that the selected peptides have better antigen epitope formation potential. Rabbit anti-GapC polyclonal antibodies were generated after immunized with the purified GapC protein, and the polyclonal antibodies were used to identify the epitope peptide by an indirect ELISA. The ELISA results showed that all of the 9 epitope peptides could react with anti-GapC polyclonal antibodies with varying titers. Among them, the epitope polypeptide 266AANDSYGYTEDPIVSSD282 reacted with the polyclonal antibodies significantly stronger than with other epitope peptides. This study laid an experimental foundation for in-depth understanding of the immunological properties and utilizing effective epitopes of the GapC protein of S. uberis.
Animals
;
Antigens, Bacterial/genetics*
;
Bacterial Proteins/genetics*
;
Epitopes, B-Lymphocyte/genetics*
;
Mice
;
Mice, Inbred BALB C
;
Rabbits
;
Streptococcus
10.Risk factors and prevention of lower extremity lymphedema after treatment for cervical cancer
Donglin LI ; Shihe HUANG ; Wenfei ZHAO ; Ling YANG ; Xuejing LIU ; Shaofang CHEN ; Xiaoling WANG
Journal of Chinese Physician 2022;24(8):1149-1152
Cervical cancer is a common malignant tumor of female reproductive system. The treatment of cervical cancer is based on surgery and radiotherapy (or concurrent chemoradiation). Lower extremity lymphedema (LEL) is a frequent complication after cervical cancer treatment, which significantly affects the quality of life of patients. Both pelvic surgery and radiation for cervical cancer can lead to LEL. The risk factors for LEL are complicated and involving characteristics regarding patient (age, comorbidities, lifestyle, etc.), tumor [International Federation of gynecology and Obstetrics (FIGO) stage, lymph node metastasis, etc.], and treatment (number of resected lymph nodes, removal of circumflex iliac nodes, adjuvant therapy, etc.). Comprehensive measures are proposed to prevent cervical cancer patients from LEL, and further investigations in terms of effectiveness are warranted.

Result Analysis
Print
Save
E-mail