1.Research on The Role of Dopamine in Regulating Sleep and Wakefulness Through Exercise
Li-Juan HOU ; Ya-Xuan GENG ; Ke LI ; Zhao-Yang HUANG ; Lan-Qun MAO
Progress in Biochemistry and Biophysics 2025;52(1):88-98
Sleep is an instinctive behavior alternating awakening state, sleep entails many active processes occurring at the cellular, circuit and organismal levels. The function of sleep is to restore cellular energy, enhance immunity, promote growth and development, consolidate learning and memory to ensure normal life activities. However, with the increasing of social pressure involved in work and life, the incidence of sleep disorders (SD) is increasing year by year. In the short term, sleep disorders lead to impaired memory and attention; in the longer term, it produces neurological dysfunction or even death. There are many ways to directly or indirectly contribute to sleep disorder and keep the hormones, including pharmacological alternative treatments, light therapy and stimulus control therapy. Exercise is also an effective and healthy therapeutic strategy for improving sleep. The intensities, time periods, and different types of exercise have different health benefits for sleep, which can be found through indicators such as sleep quality, sleep efficiency and total sleep time. So it is more and more important to analyze the mechanism and find effective regulation targets during sleep disorder through exercise. Dopamine (DA) is an important neurotransmitter in the nervous system, which not only participates in action initiation, movement regulation and emotion regulation, but also plays a key role in the steady-state remodeling of sleep-awakening state transition. Appreciable evidence shows that sleep disorder on humans and rodents evokes anomalies in the dopaminergic signaling, which are also implicated in the development of psychiatric illnesses such as schizophrenia or substance abuse. Experiments have shown that DA in different neural pathways plays different regulatory roles in sleep behavior, we found that increasing evidence from rodent studies revealed a role for ventral tegmental area DA neurons in regulating sleep-wake patterns. DA signal transduction and neurotransmitter release patterns have complex interactions with behavioral regulation. In addition, experiments have shown that exercise causes changes in DA homeostasis in the brain, which may regulate sleep through different mechanisms, including cAMP response element binding protein signal transduction, changes in the circadian rhythm of biological clock genes, and interactions with endogenous substances such as adenosine, which affect neuronal structure and play a neuroprotective role. This review aims to introduce the regulatory effects of exercise on sleep disorder, especially the regulatory mechanism of DA in this process. The analysis of intracerebral DA signals also requires support from neurophysiological and chemical techniques. Our laboratory has established and developed an in vivo brain neurochemical analysis platform, which provides support for future research on the regulation of sleep-wake cycles by movement. We hope it can provide theoretical reference for the formulation of exercise prescription for clinical sleep disorder and give some advice to the combined intervention of drugs and exercise.
2.Change Law in Material Basis of Rhei Radix et Rhizoma During Nine-time Repeating Steaming and Sun-drying Processing Based on Characteristic Chromatogram and Chemometrics
Xuan AO ; Taotao LIU ; Miao YU ; Lan WANG ; Xiaojie YIN ; Jingyu ZUO ; Li LI
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(15):191-198
ObjectiveTo characterize the changes in the overall chemical profile and key index components during nine-time repeating steaming and sun-drying processing of Rhei Radix et Rhizoma, and to reveal the change law of its material basis. MethodsHigh performance liquid chromatography(HPLC) was used to analyze the changes in the overall chemical profile of Rhei Radix et Rhizoma decoction pieces, and the contents of 15 main active components such as chrysophanol-8-O-β-D-glucoside, chrysophanol and gallic acid in the process of nine-time repeating steaming and sun-drying were determined. Combined with chemometrics, the contents and quantity ratio relationships of the glycosides, aglycones and tannins during the processing of Rhei Radix et Rhizoma were analyzed, and the partial least squares-discriminant analysis(PLS-DA) and cluster analysis of the main components in different steaming times were conducted, the statistically significant differential markers were selected with the variable importance in the projection(VIP) value>1. ResultsIn the nine-time repeating steaming and sun-drying process of Rhei Radix et Rhizoma, there were certain regularity in the number and peak area of characteristic peaks and the steaming and sun-drying times, the anthraquinone glycosides and aglycones could be roughly divided into three stages, including rapid change stage, fluctuation change stage and stable stage, and the total amount of tannins showed a decreasing trend. However, the ratios between the three components mentioned above tended to stabilize after five rounds of steaming and sun-drying. The results of PLS-DA and cluster heatmap showed that the content of each component in Rhei Radix et Rhizoma fluctuated greatly during the 1-4 steaming and sun-drying processes, while the content of each component was relatively close during the 5-9 steaming and sun-drying processes. After screening, it was found that chrysophanol, emodin, chrysophanol-8-O-β-D-glucoside, rhein, physcion and emodin-8-O-β-D-glucoside could be used as the index components for distinguishing the processed products of Rhei Radix et Rhizoma with different steaming and sun-drying times. ConclusionThe changes in the properties and efficacy of Rhei Radix et Rhizoma caused by the processing of nine-time repeating steaming and sun-drying are due to the changes in the composition and ratio of various glycosides and complex tannins in this herb, which is also the key to the formation of its characteristic of "purgation with supplement". This study can provide a basis for the research on the processing mechanism of Rhei Radix et Rhizoma and the establishment of processing specifications.
3.Advances in the application of adaptive optics visual simulators in refractive surgery
Yan WANG ; Xuan LIAO ; Changjun LAN
International Eye Science 2025;25(10):1645-1649
Adaptive optics(AO)is a technology designed to enhance the performance of optical systems through real-time measurement and correction of optical aberrations. With continuous advancements in refractive surgery techniques and rising patient expectations for surgical outcomes, the precise implementation of personalized refractive corrections has become a critical focus. The integration of AO technology into refractive surgery provides novel technical support. Specifically, the adaptive optics vision simulator(VAO)facilitates accurate preoperative objective and subjective refraction by dynamically measuring and correcting ocular wavefront aberrations, thereby improving refractive efficiency. Additionally, it enables effective prediction of postoperative aberrations for personalized procedures, assists clinicians in making data-driven preoperative decisions, facilitates comparative analysis of different surgical techniques, and allows intuitive evaluation of postoperative visual quality. This review comprehensively examines the advances in VAO applications for refractive surgery and analyzes both its clinical advantages and technical limitations.
4.Research progress on age-related changes in binocular vision
Chunyan LAI ; Changkang LUO ; Xuan LIAO ; Changjun LAN ; Qingqing TAN
International Eye Science 2025;25(11):1820-1825
With the accelerating process of population aging, binocular vision disorders have become increasingly prevalent, posing new challenges for both social aging strategies and ophthalmic clinical practice. Non-strabismic binocular vision anomalies(NSBVAs)are notably prevalent among elderly populations; however, current research predominantly focuses on the abnormality rates derived from individual binocular vision clinical tests, while data on the actual prevalence based on comprehensive diagnostic criteria remain limited. This review synthesizes existing scientific literature to provide a concise yet comprehensive overview of the prevalence, risk factors, and clinical diagnostic methods of NSBVAs in pre-presbyopic and presbyopic populations, with an in-depth examination of age-related changes in binocular vision function among older adults. By integrating and comparing analyses of the correlations between age and various binocular vision parameters, this review aims to enhance understanding of age-related binocular vision dysfunction and establish a theoretical foundation for developing targeted diagnostic and therapeutic approaches. Ultimately, these insights could contribute to improved visual performance and life satisfaction in elderly individuals.
5.Repeatability of wavefront aberration measured by adaptive optics visual simulator and agreement of OPD-Scan Ⅲ
Yan WANG ; Xuan LIAO ; Changjun LAN ; Biao LI ; Zhuang MIAO ; Qingqing TAN ; Suyun QIN ; Huan HUANG
International Eye Science 2024;24(5):810-815
AIM: To assess the repeatability and agreement of higher-order aberration obtained by adaptive optics visual simulator(VAO)compared with OPD-Scan Ⅲ.METHODS: A cross-sectional study was conducted from August to September 2023, including a total of 204 patients(204 eyes)with myopia whose right eyes were measured. The examinations were performed by the same skilled examiner using both devices separately. The VAO device was used to measure higher order aberrations of orders 3 to 6 at a pupil diameter of 4.5 mm, while both the VAO and OPD-Scan Ⅲ devices were utilized to measure total higher-order aberration(tHOA), spherical aberration(SA), coma aberration(Coma), and trefoil aberration(Trefoil)of the entire eye at pupil diameters ranging from 3 to 6 mm. Furthermore, the repeatability of whole eye aberration measurements obtained with the VAO device was evaluated and the agreement of the two devices was assessed.RESULTS: The whole-eye higher-order aberrations measured by VAO demonstrated excellent repeatability(0.767≤ICC≤0.941, Sw<0.01 μm, TRT<0.1 μm). There was no statistically significant difference in Coma measured by VAO or OPD-Scan Ⅲ for pupil diameters ranging from 4 to 6 mm(P>0.05), while a statistically significant difference was observed in whole-eye tHOA of other pupil diameters(all P<0.05). The agreement of aberration measurements for each order between VAO and OPD-Scan Ⅲ for 3 mm pupil diameters, SA at 4 and 5 mm pupil diameter and Coma at 4 mm pupil diameter showed a 95% limit of agreement(LoA)<0.1, indicating good agreement; however, poor agreement was found for the remaining aberration measurements at different pupil diameters, with a 95%LoA>0.1, and there were significant differences in higher-order aberrations measured by two devices under a pupil diameter of 3 mm(r=0.218-0.317, P<0.01), 4 mm(r=0.406-0.672, P<0.01), 5 mm(r=0.538-0.839, P<0.01 and r=0.030-0.109, P>0.01)and 6 mm(r=0.369-0.766, P<0.01).CONCLUSION: The VAO demonstrates favorable repeatability when assessing whole-eye higher order aberration under pupil diameters of 3-6 mm. However, there is inadequate agreement and interchangeability in whole-eye higher order aberration at 3-6 mm pupil diameter between VAO and OPD-Scan Ⅲ for clinical purposes.
6.Study on the Distribution Pattern of Traditional Chinese Medicine Syndromes in Patients with Dry Eye and Its Correlation with Gender and Age
Yu-Xuan LI ; Ni TIAN ; Lan YU ; Rui-Ying ZHONG
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(3):550-554
Objective To explore the etiology and pathogenesis of dry eye by studying the distribution pattern of gender,age and traditional Chinese medicine(TCM)syndrome type in dry eye patients and by analyzing their correlation.Methods A total of 244 patients with dry eye who met the inclusion criteria were selected.The distribution of gender,age and TCM syndrome types was statistically analyzed,and then the correlation of TCM syndrome types with gender and age of dry eye patients was explored.Results(1)Of the 244 dry eye patients,96(39.34%)were male and 148(60.66%)were female,the incidence of the female being higher than that of the male.There were 124(50.82%)patients younger than 45 years old,81(33.20%)patients aged 45-60 years old,and 39(15.98%)patients older than 60 years old.The proportion of the patients younger than 45 years old was higher than that of other age groups.(2)Among the 244 patients with dry eyes,89 cases(36.47%)were differentiated as liver and kidney deficiency syndrome,75 cases(30.74%)were differentiated as qi stagnation and blood stasis syndrome,69 cases(28.28%)were differentiated as spleen and kidney deficiency,and 11 cases(4.51%)were differentiated as yin deficiency and damp-heat syndrome.And the occurrence frequency of the above four syndrome types was in descending order.(3)In the dry eye patients of various age groups,patients aged<45 years old predominantly suffered from qistagnation and blood stasis syndrome,accounting for 41.94%(52/124);patients aged 45-60 years old and those aged>60 years old predominantly suffered from liver and kidney deficiency syndrome,accounting for 46.91%(38/81)and 53.85%(21/39),respectively.The distribution of TCM syndrome types varied in the patients with different age groups,and the difference was statistically significant(χ2 = 22.128,P<0.01).(4)In male dry eye patients,qi stagnation and blood stasis syndrome was predominant,accounting for 39.58%(38/96);among female dry eye patients,liver and kidney deficiency syndrome and spleen and kidney deficiency syndrome were prevalent,accounting for 41.89%(62/148)and 31.08%(46/148),respectively.The distribution of TCM syndrome types varied in the patients with different genders,and the difference was statistically significant(χ2 = 82.610,P<0.01).Conclusion The TCM syndromes of patients with dry eyes are frequently differentiated as liver and kidney deficiency syndrome,followed by the qi stagnation and blood stasis syndrome.The prevalence of dry eyes is related to the gender and age,and gender and age are correlated with the TCM syndrome types to certain extent.
7.Application of Functionalized Liposomes in The Delivery of Natural Products
Cheng-Yun WANG ; Xin-Yue LAN ; Jia-Xuan GU ; Xin-Ru GAO ; Long-Jiao ZHU ; Jun LI ; Bing FANG ; Wen-Tao XU ; Hong-Tao TIAN
Progress in Biochemistry and Biophysics 2024;51(11):2947-2959
Plant natural products have a wide range of pharmacological properties, not only can they be used as plant dietary supplements to meet the nutritional needs of the human body in the accelerated pace of life, but also occupy an important position in the research and development of therapeutic drugs for the treatment of tumors, inflammation and other diseases, and have been widely accepted by the public due to their good safety. However, despite the above advantages of plant natural products, limiting factors such as low solubility, poor stability, lack of targeting, high toxicity and side effects, and unacceptable odor have greatly impeded their conversion to clinical applications. Therefore, the development of new avenues for the application of new natural products has become an urgent problem to be solved at present. In recent years, with the continuous development of research, various strategies have been developed to improve the bioavailability of natural products. Among them, nanocarrier delivery system is one of the most attractive strategies at present. In past studies, a large number of nanomaterials (organic, inorganic, etc.) have been developed to encapsulate plant-derived natural products for their efficient delivery to specific organs and cells. Up to now, nanotechnology has not only been limited to pharmaceutical applications, but is also competing in the fields of nanofood processing technology and nanoemulsions. Among the various nanocarriers, liposomes are the largest nanocarriers with the largest market share at present. Liposomes are bilayer nanovesicles synthesized from amphiphilic substances, which have advantages such as high drug loading capacity and stability. Attractively, the flexible surface of liposomes can be modified with various functional elements. Functionalized modification of liposomes with different functional elements such as antibodies, nucleic acids, peptides, and stimuli-responsive moieties can bring out the excellent drug delivery function of liposomes to a greater extent. For example, the modification of functional elements with targeting function such as nucleic acids and antibodies on the surface of liposomes can deliver natural products to the target location and improve the bioavailability of drugs; the modification of stimulus-responsive groups such as photosensitizers, magnetic nanoparticles, pH-responsive groups, and temperature sensitizers on the surface of liposomes can achieve controlled release of drugs, localized targeting, and synergistic thermotherapy. In addition to the above properties, by using functionalized liposomes to encapsulate natural products with irritating properties can also effectively mask the irritating properties of natural products, improve public acceptance, and increase the possibility of application of irritating natural products. There are various strategies for modifying liposomes with functional elements, and the properties of functionalized liposomes constructed by different construction strategies differ. The commonly used construction strategies for functionalized liposomes include covalent modification and non-covalent modification. These two types of construction strategies have their own advantages and disadvantages. Covalent modification has better stability than non-covalent modification, but its operation is cumbersome. With the above background, this review focuses on the three typical problems faced by plant natural products at present, and summarizes the specific applications of functionalized liposomes in them. In addition, this paper summarizes the construction strategies for building different types of functionalized liposomes. Finally, this paper will also review the opportunities and challenges faced by functionalized liposomes to enter clinical therapy, and explore the opportunities to overcome these problems, with a view to better realizing the precise control of plant nanomedicines, and providing ideas and inspirations for researchers in related fields as well as relevant industrial staff.
8.Evaluation of optical performance of aspherical intraocular lens in vitro by optical bench
Lixuan XIE ; Xuan LIAO ; Changjun LAN ; Qingqing TAN ; Ruolin PAN ; Yuling TANG ; Suyun QIN ; Yan WANG
Chinese Journal of Experimental Ophthalmology 2024;42(3):240-247
Objective:To evaluate the optical performance of two aspheric intraocular lenses (IOL) AcrySof IQ SN60WF and Proming A1-UV with identical negative spherical aberration values, using the optical bench OptiSpheric IOL R&D through an in vitro study. Methods:The optical performance of + 20.0 D blue-light filtering SN60WF and monofocal high-order aspheric non blue-light filtering A1-UV IOL was evaluated through cornea models with the spherical aberration of 0 μm (ISO-1) and + 0.28 μm (ISO-2) under apertures of 3.0 mm and 4.5 mm via the optical bench OptiSpheric IOL R&D.The modulation transfer function (MTF) and USAF 1951 resolution test chart were employed to measure the IOL with centering, decentration of 0.3, 0.5, 0.7, 0.9 and 1.1 mm, as well as tilt of 3°, 5°, 7°, 9° and 11°.The spectral transmittance of IOL was measured with the UV-3300 UV-VIS spectrophotometer.Results:Compared with the A1-UV IOL, the spectral transmittance of SN60WF for blue light with wavelengths of 400-500 nm was significantly reduced, which effectively reduced the passage of blue light.At an aperture of 3.0 mm, the MTF values at 100 lp/mm spatial frequency for the centered SN60WF and A1-UV were 0.576 and 0.598 under ISO-1 corneal measurement conditions, 0.564 and 0.563 under ISO-2 conditions.At an aperture of 4.5 mm, the MTF values were 0.238 and 0.404 under ISO-1 corneal measurement conditions, and 0.438 and 0.339 under ISO-2 conditions.The MTF values of A1-UV and SN60WF at 3.0 mm aperture and 100 lp/mm spatial frequency under ISO-1 corneal measurement conditions were larger than those under ISO-2 corneal measurement conditions.Under ISO-1 corneal measurement conditions with a 3.0 mm aperture, A1-UV had a better optical quality compared to SN60WF, whereas under ISO-2 corneal measurement conditions, the optical quality of both IOLs was similar.Under the 3.0 mm aperture, the MTF values of SN60WF and A1-UV at a decentration of 0.3 mm and 100 lp/mm spatial frequency were 0.414 and 0.571 under ISO-1 corneal measurement conditions, 0.438 and 0.512 under ISO-2 corneal measurement conditions, respectively.The MTF values of SN60WF and A1-UV at a tilt of 3° were 0.522 and 0.597 under ISO-1 corneal measurement conditions, and 0.532 and 0.531 under ISO-2 corneal measurement conditions.The MTF values and USAF resolution test chart of A1-UV had no significant change between the two corneal measurement conditions.When subjected to equal degrees of decentration or tilting, except for the ISO-1 corneal measurement conditions at a 4.5 mm aperture, the MTF values of A1-UV showed a gradual decline across various spatial frequencies compared to SN60WF.With the increase in aperture size, the impact of IOL decentration or tilting on MTF values and USAF 1951 resolution test chart became more notable for A1-UV relative to SN60WF.Conclusions:The SN60WF IOL effectively filters blue light within the wavelength range of 400-500 nm.However, when both IOL experience decentration greater than 0.3 mm or tilting beyond 3°, the optical quality of the IOL will decline.A1-UV has a distinct advantage over SN60WF in terms of resistance to both decentration and tilting-induced optical performance degradation in vitro.
9.Research progress in the application of in vitro optical quality test system for the assessment of IOL optical quality
Ruolin PAN ; Xuan LIAO ; Changjun LAN
Chinese Journal of Experimental Ophthalmology 2024;42(3):290-296
Surgery is currently the only effective treatment for cataract.As the standard of living improves, people's demand for postoperative visual quality increases, and a variety of functional artificial lenses (IOL) have been continuously introduced.The in vitro optical quality testing system is used for the design and optimization of new IOL and for the preliminary clinical study of IOL to evaluate the effects of influencing factors such as IOL material, design, decentration, tilt, rotation, incident light wavelength and pupil diameter on the optical quality of IOL.It is helpful for doctors to fully understand and correctly select IOL. In vitro optical quality test systems mainly include optical testing platform and optical design software.The former can experimentally measure IOL, while the latter can perform optical numerical simulation of IOL. In vitro optical quality test systems have received increasing attention in China in recent years.This article reviews the in vitro optical quality test system of IOL and its clinical application.This article reviews the commonly used in vitro optical quality test systems and their clinical applications, including the measurement and evaluation indicators of in vitro optical quality, the construction of optical test platforms (OptiSpheric ? IOL PRO, Badal Optometer, PMTF, and NIMO) and the measurement principles of optical design software (ZEMAX, OSLO, and VirtualLab), as well as their applications in IOL optical quality evaluation and the limitations of in vitro optical testing.
10.Implementation of surveillance,prevention and control of healthcare-asso-ciated infection in maternal and child healthcare institutions:A nation-wide investigation report
Shuo LI ; Xi YAO ; Hui-Xue JIA ; Wei-Guang LI ; Xun HUANG ; Shu-Mei SUN ; Xi CHENG ; Qing-Lan MENG ; Xiang ZHANG ; Jing-Ping ZHANG ; Ya-Wei XING ; Qing-Qing JIANG ; Lian-Xuan WU ; Bing-Li ZHANG ; Xiao-Jing LIU ; Liu-Yi LI
Chinese Journal of Infection Control 2024;23(3):323-329
Objective To investigate the implementation of surveillance,prevention and control measures for healthcare-associated infection(HAI)in maternal and child healthcare(MCH)institutions,and provide policy evi-dence for optimizing HAI prevention and control in MCH institutions.Methods Stratified sampling was conducted among the MCH institutions at provincial,municipal and county levels in 8 provinces/autonomous regions.A uni-fied questionnaire was designed and the online survey was conducted through"Questionnaire Star".Results The data from 123 MCH institutions were included in the analysis.90.24%of the MCH institutions carried out compre-hensive surveillance on HAI.The ratios of MCH institutions which implemented targeted surveillance on HAI in neonatal intensive care unit(NICU),surgical site infection,multidrug-resistant organisms(MDROs)and HAI in intensive care units(non-NICU excluded)were 89.66%,85.96%,80.77%,and 74.19%,respectively.51.22%MCH institutions adopted information surveillance system on HAI cases.94.31%MCH institutions carried out surveillance on hand hygiene compliance.Over 90%MCH institutions carried out surveillance on environment hy-giene in high-risk departments.71.54%MCH institutions conducted centralized cleaning,disinfection,sterilization and supply for reusable medical instruments in the central sterile supply department(CSSD).Over 90%MCH insti-tutions established three-level pre-examination triage systems.86.18%set up transitional wards.MCH institutions generally adopted a management model with established effective communication,full appointment visits,and sepa-rate visits for special medical groups,such as registered pregnant women,high-risk newborns,healthcare groups,and long-term rehabilitation patients.However,the ratio of institutions conducting on-line follow-up visits was less than 50%.Conclusion MCH institutions have generally carried out comprehensive and targeted surveillance on HAI.Information surveillance need to be facilitated.Hand hygiene and environmental hygiene surveillance has been popularized to a certain extent at all levels of MCH institutions.The cleaning,disinfection,sterilization,and supply processes of reusable medical devices in a few MCH institutions are not standardized.Special medical populations get effective management.On-line healthcare is to be further promoted.

Result Analysis
Print
Save
E-mail