1.Analysis of factors influencing macular edema in patients with diabetes cataract after surgery
Ming LI ; Fang XU ; Zhijuan XU
International Eye Science 2025;25(1):140-143
AIM: To explore the risk factors of macular edema in patients with diabetes cataract after surgery, and provide reference for postoperative prevention and treatment.METHODS: A total of 55 diabetes cataract patients(55 eyes)with macular edema after phacoemulsification surgery at the ophthalmology department of Jiaozhou Central Hospital of Qingdao from January 2022 to January 2024 were selected as edema group. In addition, 59 patients(59 eyes)with diabetes cataract who received the same surgical treatment but did not develop macular edema were treated as control group, and the relationship between interferon-induced protein-10(IP-10), macrophage chemotactic protein-1(MCP-1), vascular endothelial growth factor(VEGF)and postoperative macular edema was analyzed.RESULTS:Age, diabetes course, best corrected visual acuity(BCVA), glycated hemoglobin(HbA1c), creatinine, levels of IP-10, MCP-1 and VEGF in aqueous humor in the edema group were higher than those in the control group(all P<0.05). The risk factors for postoperative macular edema in patients with diabetes cataract were prolonged duration of diabetes, BCVA, increased HbA1c, increased creatinine and IP-10 in aqueous fluid, increased MCP-1 and increased VEGF(all P<0.05).CONCLUSION:Macular edema after surgical treatment in diabetes cataract patients is associated with prolonged duration of diabetes, BCVA, HbA1c, creatinine, IP-10, MCP-1, and VEGF, and clinical interventions should be given in advance.
2.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
3.Exploration of Pulmonary Vascular Remodeling Improvement in Rats at Different Stages of Chronic Obstructive Pulmonary Disease by Qibai Pingfei Capsules Based on TLR4/NF-κB Signaling Pathway
Lu ZHANG ; Li FANG ; Shuyu XU ; Xue LIANG ; Jie ZHU ; Xiangli TONG ; Zegeng LI
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(9):48-56
ObjectiveTo investigate the improvement effect of Qibai Pingfei capsules on pulmonary vascular remodeling in rats at different stages of chronic obstructive pulmonary disease (COPD) and to analyze its possible mechanism of action. MethodsMale Sprague-Dawley (SD) rats were randomly divided into a normal group, an early COPD model group, an advanced COPD model group, an early-intervention high-dose group, a late-intervention high-dose group, an early-intervention low-dose group, a late-intervention low-dose group, an early-intervention pyrrolidine dithiocarbamate (PDTC) group, and a late-intervention PDTC group, with 15 rats in each group. A rat model of early COPD was constructed by using cigarette smoke combined with airway infusion using lipopolysaccharide(LPS), and a rat model of advanced COPD was constructed by using airway infusion with LPS, cigarette smoke, and hypoxia. All groups except the normal group were given LPS airway drops on days 1 and 14 of the experiment, smoked for 1 h per day, and administered the drug once a day for 40 weeks from day 15 onward. In the high- and low-dose groups, rats were given 1 g·kg-1 and 250 mg·kg-1 Qibai Pingfei capsules, respectively by gavage, and in PDTC groups, rats were given 100 mg·kg-1 of PDTC by intraperitoneal injection. The advanced COPD model group underwent 6 h of hypoxia per day in weeks 5-6. Lung function and mean pulmonary artery pressure were tested in rats. Morphologic changes in lung tissues were detected by hematoxylin-eosin(HE)staining. Collagen deposition in lung tissues was examined by Masson staining, and the levels of inflammatory factors including interleukin-1β(IL-1β), interleukin-6(IL-6), and tumor necrosis factor-α(TNF-α)in lung tissues were detected by enzyme-linked immunosorbent assay (ELISA). The number of inflammatory cells in the alveolar lavage fluid of rats in each group was detected by Giemsa staining, and the protein expression of Toll-like receptor 4(TLR4), myeloid differentiation factor 88(MyD88), nuclear factor-κB(NF-κB), TNF-α, vascular endothelial-cadherin(VE-cadherin), α-smooth muscle actin(α-SMA), and platelet endothelial cell adhesion molecule-1(CD31) was detected by Western blot in the lung tissues of rats. ResultsCompared with the normal group, the model group showed significantly decreased forced expiratory volume in 0.3 s (FEV0.3), forced vital capacity (FVC), and FEV0.3/FVC ratio related to lung function (P<0.05), thickening of pulmonary vasculature, increased collagen deposition in the lungs, and enhanced mean pulmonary arterial pressure and expression levels of IL-6, IL-1β, and TNF-α (P<0.05). Additionally, the model group also exhibited increased numbers of macrophages, lymphocytes, and neutrophils (P<0.05), significantly higher protein expression of TLR4, MyD88, NF-κB, TNF-α, and α-SMA (P<0.05), and significantly lower protein expression of VE-cadherin and CD31 (P<0.05). Lung function was significantly improved in the Qibai Pingfei capsules groups compared with the model group (P<0.05), with mean pulmonary arterial pressure reduced and pulmonary vascular thickening and collagen deposition in the lungs ameliorated. The Qibai Pingfei capsules groups also showed reduced expression levels of IL-6, IL-1β, and TNF-α (P<0.05) and decreased numbers of macrophages, lymphocytes, and neutrophils (P<0.05), as well as reduced protein expression of TLR4, MyD88, NF-κB, TNF-α, and α-SMA (P<0.05) and elevated protein expression of VE-cadherin and CD31 (P<0.05) in rat lung tissues. ConclusionQibai Pingfei capsules inhibits inflammatory response and endothelial-to-mesenchymal transition probably by regulating the TLR4/NF-κB signaling pathway, thus improving pulmonary vascular remodeling in COPD model rats and showing therapeutic effects in the early stage of COPD.
4.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
5.Establishment and stress analysis of a finite element model for adolescent cervical disc herniation
Yuxin ZHAO ; Liang LIANG ; Feng JIN ; Yangyang XU ; Zhijie KANG ; Yuan FANG ; Yujie HE ; Xing WANG ; Haiyan WANG ; Xiaohe LI
Chinese Journal of Tissue Engineering Research 2025;29(3):448-454
BACKGROUND:Cervical disc herniation can cause pain in the neck and shoulder area,as well as radiating pain in the upper limbs.The incidence rate is increasing year by year and tends to affect younger individuals.Fully understanding the biomechanical characteristics of the cervical spine in adolescents is of great significance for preventing and delaying the onset of cervical disc herniation in this age group. OBJECTIVE:To reconstruct cervical spine models for both healthy adolescents and adolescent patients with cervical disc herniation utilizing finite element analysis techniques,to analyze the motion range of the C1-T1 cervical vertebrae as well as the biomechanical characteristics of the annulus fibrosus,nucleus pulposus,endplates,and the cartilage of the small joints. METHODS:A normal adolescent's cervical spine and an adolescent patient with cervical disc herniation were selected in this study.The continuous scan cervical spine CT raw image data were imported into Mimics 21.0 in DICOM format.The C1-T1 vertebrae were reconstructed separately.Subsequently,the established models were imported into the 3-Matic software for disc reconstruction.The perfected models were then imported into Hypermesh software for meshing of the vertebrae,nucleus pulposus,annulus fibrosus,and ligaments,creating valid geometric models.After assigning material properties,the final models were imported into ABAQUS software to observe the joint motion range of the C1-C7 cervical vertebrae segments under different conditions,and to analyze the biomechanical characteristics of the annulus fibrosus,nucleus pulposus,endplates,and small joint cartilage of each cervical spine segment. RESULTS AND CONCLUSION:(1)In six different conditions,the joint motion range of the C1 vertebra in the cervical spine models of both normal adolescent and adolescent patient with cervical disc herniation was higher than that of the other vertebrae.Additionally,the joint motion range of each cervical spine segment in normal adolescent was greater than that in adolescent patient with cervical disc herniation.(2)In the cervical spine model of normal adolescent,the maximum stress values in the annulus fibrosus and nucleus pulposus were found on the left side during C2-3 flexion conditions(0.43 MPa and 0.17 MPa,respectively).In the cervical spine model of adolescent patient with cervical disc herniation,the maximum stress values were found on the left side during C7-T1 flexion conditions(0.54 MPa and 0.18 MPa,respectively).(3)In the cervical spine model of normal adolescent,the maximum stress value on the endplate was found on the left side of the upper endplate of C3 during flexion conditions(1.46 MPa).In the model of adolescent patient with cervical disc herniation,the maximum stress value on the endplate was found on the left side of the lower endplate of C7 during flexion conditions(1.32 MPa).(4)In the cervical spine model of normal adolescent,the maximum stress value in the small joint cartilage was found in the C2-3 left rotation conditions(0.98 MPa).In adolescent patient with cervical disc herniation,the stress in the small joint cartilage significantly increased under different conditions,especially in C1-2,with the maximum stress found during left flexion(3.50 MPa).(5)It is concluded that compared to normal adolescent,adolescent patient with cervical disc herniation exhibits altered cervical curvature and a decrease in overall joint motion range in the cervical spine.In adolescent with cervical disc herniation,there is a significant increase in stress on the annulus fibrosus,nucleus pulposus,and endplates in the C7-T1 segment.The stress on the left articular cartilage of the C1-2 is notable.Abnormal cervical curvature may be the primary factor causing these stress changes.
6.Gradient artificial bone repair scaffold regulates skeletal system tissue repair and regeneration
Yu ZHANG ; Ruian XU ; Lei FANG ; Longfei LI ; Shuyan LIU ; Lingxue DING ; Yuexi WANG ; Ziyan GUO ; Feng TIAN ; Jiajia XUE
Chinese Journal of Tissue Engineering Research 2025;29(4):846-855
BACKGROUND:Gradient artificial bone repair scaffolds can mimic unique anatomical features in musculoskeletal tissues,showing great potential for repairing injured musculoskeletal tissues. OBJECTIVE:To review the latest research advances in gradient artificial bone repair scaffolds for tissue engineering in the musculoskeletal system and describe their advantages and fabrication strategies. METHODS:The first author of the article searched the Web of Science and PubMed databases for articles published from 2000 to 2023 with search terms"gradient,bone regeneration,scaffold".Finally,76 papers were analyzed and summarized after the screening. RESULTS AND CONCLUSION:(1)As an important means of efficient and high-quality repair of skeletal system tissues,gradient artificial bone repair scaffolds are currently designed bionically for the natural gradient characteristics of bone tissue,bone-cartilage,and tendon-bone tissue.These scaffolds can mimic the extracellular matrix of native tissues to a certain extent in terms of structure and composition,thus promoting cell adhesion,migration,proliferation,differentiation,and regenerative recovery of damaged tissues to their native state.(2)Advanced manufacturing technology provides more possibilities for gradient artificial bone repair scaffold preparation:Gradient electrospun fiber scaffolds constructed by spatially differentiated fiber arrangement and loading of biologically active substances have been developed;gradient 3D printed scaffolds fabricated by layered stacking,graded porosity,and bio-3D printing technology;gradient hydrogel scaffolds fabricated by in-situ layered injections,simple layer-by-layer stacking,and freeze-drying method;and in addition,there are also scaffolds made by other modalities or multi-method coupling.These scaffolds have demonstrated good biocompatibility in vitro experiments,were able to accelerate tissue regeneration in small animal tests,and were observed to have significantly improved histological structure.(3)The currently developed gradient artificial bone repair scaffolds have problems such as mismatch of gradient scales,unclear material-tissue interactions,and side effects caused by degradation products,which need to be further optimized by combining the strengths of related disciplines and clinical needs in the future.
7.Investigation and analysis of drug use and pharmaceutical care in tight medical alliance in Wanzhou District of Chongqing
Suxin WAN ; Qiuyan SUN ; Caibing XU ; Li SHEN ; Hongmei GONG ; Wei FANG
China Pharmacy 2025;36(1):19-23
OBJECTIVE To investigate the use of drugs and the development of pharmaceutical care in the tight medical alliance (shorted for “medical alliance”) of Wanzhou District of Chongqing, and provide reference for the further construction of the medical alliance. METHODS A survey form was designed and distributed to 21 constituent units (5 leading units and 16 member units) of 5 medical alliances in Wanzhou District of Chongqing. The statistical analysis was conducted in aspects of basic drug allocation and use, pharmaceutical personnel team construction, the development of pharmaceutical care, and rational use of antibiotics. RESULTS Among the 21 constituent units, 4 leading units and 14 member units achieved the target for the proportion of essential drug procurement varieties, with a total compliance rate of 85.71%; 4 leading units and 13 member units achieved the target for the proportion of national essential drug allocation and usage amount, with a total compliance rate of 80.95%. The proportions of personnel with doctoral degrees in the 5 leading units and 16 member units were 1.71% and 0 respectively, and the proportions of personnel with senior professional titles were 8.56% and 1.63%, respectively. A total of 5 pharmacy or pharmaceutical combined outpatient clinics were set up in the 21 medical alliance units, and 5 clinical pharmacy information service platforms were established; all 5 leading units were able to regularly carry out clinical pharmacy projects, while only 4 out of 16 member units had conducted medical order review and evaluation. The proportions of irrational use of antibiotics in outpatient prescriptions and inpatient medical records of the 16 member units (4.81%, 5.21%) were significantly higher than those of the 5 leading units (2.80%, 4.00%). CONCLUSIONS The allocation and usage of national essential drugs in 21 constituent units from Wanzhou District of Chongqing are both in good standing. However, the data on the allocation of pharmaceutical professionals and the number, qualifications, and job titles of clinical pharmacists in member units are generally low. Moreover, the pharmaceutical service projects and service quality in member units need to be further improved.
8.The Effect of Banxia Xiexin Decoction (半夏泻心汤) on the Expression of LXRα in Liver Tissue and the JAK2/STAT3 Signaling Pathway in Gastric Antrum Tissue of Diabetic Gastroparesis Model Rats
Qi XU ; Nuobing RUAN ; Jinju LI ; Xijuan LYU ; Zhaohui FANG
Journal of Traditional Chinese Medicine 2025;66(2):178-187
ObjectiveTo explore the potential mechanism of Banxia Xiexin Decoction (半夏泻心汤, BXD) in the treatment of diabetic gastroparesis (DGP). MethodsA total of 29 SD rats were randomly divided into four groups, blank group (5 rats) and model group, BXD group and metformin group (8 rats in each group). Except for the blank group, rats were administered intraperitoneally with 1% streptozotocin (STZ) solution and were fed a high-sugar, high-fat diet to establish the DGP rat model. After successful modeling, the BXD group was treated with BXD at 6.68 g/(kg·d) by gavage, the metformin group was treated with metformin hydrochloride at 105 mg/(kg·d) by gavage, and the blank group and the model group were treated with normal saline at 6.68 ml/(kg·d) by gavage, for 8 weeks. After the last administration, fasting blood glucose (FBG), glycated hemoglobin (HbA1c), total cholesterol (TC), triglycerides (TG) were measured and gastric emptying rate was calculated. ELISA was used to detect the levels of gastrointestinal hormones motilin (MTL) and gastrin (GAS), as well as inflammatory factors including tumor necrosis factor-α (TNF-α), interleukin-6 (IL-6), interleukin-1β (IL-1β) and interleukin-10 (IL-10) in gastric tissue. Oil red O staining was performed to observe liver pathological morphology. Hematoxylin and eosin (HE) staining was used to observe gastric antrum tissue morphology. Immunofluorescence staining was used to detect liver X receptor α (LXRα) levels in the liver. Western Blot was used to detect the protein levels of LXRα in liver tissue, and of janus kinase 2 (JAK2), phospho-janus kinase 2 (p-JAK2), signal transducer and activator of transcription 3 (STAT3) and phospho-signal transducer and activator of transcription 3 (p-STAT3) in gastric antrum tissue. Quantitative real-time polymerase chain reaction (qPCR) was used to measure the mRNA expression of LXRα in liver tissue and JAK2, STAT3 in gastric antrum tissue. ResultsCompared with the blank group, the model group showed significant hepatic fatty degeneration, gastric antrum tissue structure destruction, and increases in FBG, HbA1c, TC, and TG levels; the average fluorescence intensity, protein level, and mRNA expression of LXRα in liver tissue were reduced; the gastric emptying rate and gastric tissue GAS and MTL levels decreased; inflammatory factors including TNF-α, IL-6, IL-1β in gastric tissue increased, IL-10 decreased; in gastric antrum tissue, the mRNA expression of p-JAK2/JAK2, p-STAT3/STAT3, and JAK2 and STAT3 increased (P<0.01). Compared with the model group, both the BXD group and the metformin group showed improved liver and gastric antrum tissue pathology; FBG, HbA1c, TC, and TG levels decreased, while LXRα fluorescence intensity, protein level, and mRNA expression in liver tissue significantly increased; the gastric emptying rate and the levels of GAS and MTL in gastric tissue were markedly higher; the levels of TNF-α, IL-6, and IL-1β decreased, whereas IL-10 levels increased, p-JAK2/JAK2, p-STAT3/STAT3, and the mRNA expression of JAK2 and STAT3 in gastric antrum tissue decreased (P<0.05 or P<0.01). The BXD group showed higher level than the metformin group in FBG, HbA1c, and TG levels, lower level in gastric emptying rate and gastric tissue GAS content, and higher level in gastric tissue TNF-α, IL-6, IL-1β levels; there was also a decrease in IL-10 levels, and a reduction in LXRα fluorescence intensity and mRNA expression in liver tissue, as well as in p-JAK2/JAK2 levels in gastric antrum tissue (P<0.05 or P<0.01). ConclusionBXD can reduce blood glucose and lipid levels in DGP model rats while improving gastric function and alleviating gastric tissue inflammation. Its mechanism may be related to the regulation of LXRα expression in liver tissue and the JAK2/STAT3 pathway in gastric antrum tissue.
9.Urban-rural difference in adverse outcomes of pulmonary tuberculosis in patients with pulmonary tuberculosis-diabetes mellitus comorbidity
FANG Zijian ; LI Qingchun ; XIE Li ; SONG Xu ; DAI Ruoqi ; WU Yifei ; JIA Qingjun ; CHENG Qinglin
Journal of Preventive Medicine 2025;37(1):7-11
Objective:
To investigate the urban and rural differences in adverse outcomes of pulmonary tuberculosis (PTB) in patients with pulmonary tuberculosis-diabetes mellitus comorbidity (PTB-DM), so as to provide insights into improving the prevention and treatment measures for PTB-DM.
Methods:
Patients with PTB-DM who were admitted and discharged from 14 designated tuberculosis hospitals in Hangzhou City from 2018 to 2022 were selected. Basic information, and history of diagnosis and treatment were collected through hospital information systems. The adverse outcomes of PTB were defined as endpoints, and the proportions of adverse outcomes of PTB in urban and rural patients with PTB-DM were analyzed. Factors affecting the adverse outcomes of PTB were identified using a multivariable Cox proportional hazards regression model.
Results:
A total of 823 patients with PTB-DM were enrolled, including 354 (43.01%) urban and 469 (56.99%) rural patients. There were 112 (13.61%) patients with adverse outcomes of PTB. The proportions of adverse outcomes of PTB in urban and rural patients were 14.41% and 13.01%, respectively, with no statistically significant difference (P>0.05). Multivariable Cox proportional hazards regression analysis identified first diagnosed in county-level hospitals or above (HR=2.107, 95%CI: 1.181-3.758) and drug resistance (HR=3.303, 95%CI: 1.653-6.600) as the risk factors for adverse outcomes of PTB in urban patients with PTB-DM, while the treatment/observed management throughout the process (HR=0.470, 95%CI: 0.274-0.803) and fixed-dose combinations throughout the process (HR=0.331, 95%CI: 0.151-0.729) as the protective factors for adverse outcomes in rural patients with PTB-DM.
Conclusions
There are differences in influencing factors for adverse outcomes of PTB in urban and rural patients with PTB-DM. The adverse outcomes of PTB are associated with first diagnosed hospitals and drug resistance in urban patients, and are associated with the treatment/observed management and fixed-dose combinations throughout the process in rural patients.
10.Correlation between fundus blood flow parameters and carotid artery ultrasound blood flow parameters in patients with hypertensive retinopathy
Fang YUAN ; Wenxiu XIA ; Peiqiu XU ; Yawei LI ; Junchen CHEN ; Xiaoling ZHANG
International Eye Science 2025;25(2):306-310
AIM: To investigate the correlation between fundus blood flow parameters and carotid artery ultrasound blood flow parameters in patients with hypertensive retinopathy(HRP).METHODS: A total of 50 patients(22 left eyes and 28 right eyes)with HRP admitted to our hospital from June 2021 to June 2023 were retrospectively included as the experimental group, and 50 healthy physical examination subjects(22 left eyes and 28 right eyes)during the same period were included as the healthy group. Pearson correlation was used to analyze the correlation between fundus blood flow parameters and carotid artery ultrasound blood flow parameters.RESULTS: The AUC values of fundus blood flow parameters and carotid artery ultrasound blood flow parameters and their combined diagnosis of HRP were 0.853, 0.844 and 0.935, respectively. Pearson correlation analysis showed that carotid systolic peak blood flow velocity was negatively correlated with foveal avascular zone(FAZ)area, FAZ circumference and non-circularity index, and positively correlated with macular vascular density(all P<0.05). The end-diastolic blood flow velocity was positively correlated with FAZ area and macular vascular density(all P<0.05). The internal carotid artery resistance index was positively correlated with FAZ area(P<0.05).CONCLUSION: The combination of fundus blood flow parameters and carotid artery ultrasound blood flow parameters in the diagnosis of HRP has good application value in the diagnosis of HRP.


Result Analysis
Print
Save
E-mail