1.Molecular biological mechanism of acquired heterotopic ossification
Yang XIONG ; Shibo ZHOU ; Xing YU ; Lianyong BI ; Jizhou YANG ; Fengxian WANG ; Yi QU ; Yongdong YANG ; Dingyan ZHAO ; He ZHAO ; Ziye QIU ; Guozheng JIANG
Chinese Journal of Tissue Engineering Research 2024;28(30):4881-4888
BACKGROUND:Heterotopic ossification is a dynamic growth process.Diverse heterotopic ossification subtypes have diverse etiologies or induction factors,but they exhibit a similar clinical process in the intermediate and later phases of the disease.Acquired heterotopic ossification produced by trauma and other circumstances has a high incidence. OBJECTIVE:To summarize the molecular biological mechanisms linked to the occurrence and progression of acquired heterotopic ossification in recent years. METHODS:The keywords"molecular biology,heterotopic ossification,mechanisms"were searched in CNKI,Wanfang,PubMed,Embase,Web of Science,and Google Scholar databases for articles published from January 2016 to August 2022.Supplementary searches were conducted based on the obtained articles.After the collected literature was screened,131 articles were finally included and summarized. RESULTS AND CONCLUSION:(1)The occurrence and development of acquired heterotopic ossification is a dynamic process with certain concealment,making diagnosis and treatment of the disease difficult.(2)By reviewing relevant literature,it was found that acquired heterotopic ossification involves signaling pathways such as bone morphogenetic protein,transforming growth factor-β,Hedgehog,Wnt,and mTOR,as well as core factors such as Runx-2,vascular endothelial growth factor,hypoxia-inducing factor,fibroblast growth factor,and Sox9.The core mechanism may be the interaction between different signaling pathways,affecting the body's osteoblast precursor cells,osteoblast microenvironment,and related cytokines,thereby affecting the body's bone metabolism and leading to the occurrence of acquired heterotopic ossification.(3)In the future,it is possible to take the heterotopic ossification-related single-cell osteogenic homeostasis as the research direction,take the osteoblast precursor cells-osteogenic microenvironment-signaling pathways and cytokines as the research elements,explore the characteristics of each element under different temporal and spatial conditions,compare the similarities and differences of the osteogenic homeostasis of different types and individuals,observe the regulatory mechanism of the molecular signaling network of heterotopic ossification from a holistic perspective.It is beneficial to the exploration of new methods for the future clinical prevention and treatment of heterotopic ossification.(4)Meanwhile,the treatment methods represented by traditional Chinese medicine and targeted therapy have become research hotspots in recent years.How to link traditional Chinese medicine with the osteogenic homeostasis in the body and combine it with targeted therapy is also one of the future research directions.(5)At present,the research on acquired heterotopic ossification is still limited to basic experimental research and the clinical prevention and treatment methods still have defects such as uncertain efficacy and obvious side effects.The safety and effectiveness of relevant targeted prevention and treatment drugs in clinical application still need to be verified.Future research should focus on clinical prevention and treatment based on basic experimental research combined with the mechanism of occurrence and development.
2.Application of polyetheretherketone rod semi-rigid pedicle screw internal fixation in lumbar non-fusion surgery
Tao LIU ; Xing YU ; Jian-Bin GUAN ; Yong-Dong YANG ; He ZHAO ; Ji-Zhou YANG ; Yi QU ; Feng-Xian WANG ; Ding-Yan ZHAO ; Zi-Yi ZHAO
China Journal of Orthopaedics and Traumatology 2024;37(7):676-683
Objective To investigate the effect of Polyetheretherketone(PEEK)rod semi-rigid pedicle screw fixation sys-tem in lumbar spine non-fusion surgery.Methods A total of 74 patients with tow-level lumbar degenerative diseases who un-derwent surgery from March 2017 to December 2019 were divided into PEEK rod group and titanium rod group.In the PEEK rod group,there were 34 patients,including 13 males and 21 females,aged from 51 to 79 years old with an average of(62.4±6.8)years old;There were 1 patient of L1-L3 segments,7 patients of L2-L4 segments,20 patients of L3-L5 segments and 6 pa-tients of L4-S1 segments.In the titanium rod group,there were 40 patients,including 17 males and 23 females,aged from 52 to 81 years old with an average of(65.2±7.3)years old;There were 3 patient of L1-L3 segments,11 patients of L2-L4 segments,19 patients of L3-L5 segments and 7 patients of L4-S1 segments.The general conditions of operation,such as operation time,intraoperative blood loss,postoperative drainage was recorded.The visual analogue scale(VAS)for low back pain and Os-westry disability index(ODI)were compared in preoperatively and postoperatively(3 months,12 months and last follow-up)between two groups.The change of range of motion(ROM)was observed by flexion and extension x-ray of lumbar Results All patients successfully completed the operation.The follow-up time ranged from 22 to 34 months with an average of(26.8±5.6)months.The operative time(142.2±44.7)min and intraoperative blood loss(166.5±67.4)ml in PEEK group were lower than those in titanium group[(160.7±57.3)min、(212.8±85.4)ml](P<0.05).There was no significant differences in postoperative drainage between the two groups(P>0.05).At the final follow-up visit,in PEEK group and titanium group VAS of low back pain[(0.8±0.4)points vs(1.0±0.5)points],VAS for leg pain[(0.7±0.4)points vs(0.8±0.5)points]and ODI[(9.8±1.6)%vs(12.1±1.5)%]were compared with preoperative[(5.8±1.1)points vs(6.0±1.1)points],[(7.2±1.7)points vs(7.0±1.6)points],[(68.5±8.9)%vs(66.3±8.2)%]were significantly different(P<0.05).There was no significant difference in VAS scores between the two groups at each postoperative time point(P>0.05).At 3 months after surgery,there was no difference in ODI between the two groups(P>0.05).There were significant differences in ODI between PEEK group and titanium rod group at 12 months[(15.5±2.1)%vs(18.4±2.4)%]and at the last follow-up[(9.8±1.6)%vs(12.1±1.5)%](P<0.05).The total range of motion(ROM)of lumbar decreased in both groups after surgery.At 12 months after surgery and the last follow-up,the PEEK group compared with the titanium rod group,the total range of motion of lumbar was statistically significant(P<0.05).The range of motion(ROM)of the fixed segments decreased in both groups after surgery.The ROM of the fixed segments in PEEK group decreased from(9.5±4.6)° to(4.1±1.9)° at the last follow-up(P<0.05),which in the titanium rod group was de-creased from(9.8±4.3)°to(0.9±0.5)° at the last follow-up(P<0.05).The range of motion(ROM)of upper adjacent segment increased in both groups,there was statistical significance in the ROM of upper adjacent segment between the two groups at 12 months after surgery and the last follow-up,(P<0.05).There was no screw loosening and broken rods in both groups during the follow-up period.Conclusion The PEEK rod semi-rigid pedicle screw internal fixation system used in lumbar non-fusion surgery can retain part of the mobility of the fixed segment,showing comparable short-term clinical efficacy to titanium rod fu-sion.PEEK rod semi-rigid pedicle screw internal fixation system is a feasible choice for the treatment of lumbar spine degener-ative diseases,and its long-term efficacy needs further follow-up observation.
3.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
4.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
5.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
6.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
7.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
8.Varieties systematization and standards status analysis of fermented Chinese medicine.
Ting-Ting FU ; Xing-Bin YIN ; Meng-Ru CAI ; Rong-Yue ZHU ; Hua-Ting HUANG ; Shi-Lang LIAO ; Chang-Hai QU ; Xiao-Xu DONG ; Yue-Hua ZHOU ; Jian NI
China Journal of Chinese Materia Medica 2023;48(10):2699-2712
Fermented Chinese medicine has long been used. Amid the advance for preservation of experience, the connotation of fermented Chinese medicine has been enriched and improved. However, fermented Chinese medicine prescriptions generally contain a lot of medicinals. The fermentation process is complicated and the conventional fermentation conditions fail to be strictly controlled. In addition, the judgment of the fermentation end point is highly subjective. As a result, quality of fermented Chinese medicine is of great difference among regions and unstable. At the moment, the quality standards of fermented Chinese medicine are generally outdated and different among regions, with simple quality control methods and lacking objective safe fermentation-specific evaluation indictors. It is difficult to comprehensively evaluate and control the quality of fermented medicine. These problems have aroused concern in the industry and also affected the clinical application of fermented Chinese medicine. This article summarized and analyzed the application, quality standards, and the modernization of fermentation technology and quality control methods of fermented Chinese medicine and proposed suggestions for improving the quality standards of the medicine, with a view to improving the overall quality of it.
Medicine, Chinese Traditional
;
Reference Standards
;
Quality Control
;
Fermentation
9.Proposal and thoughts on establishing and improving multi-level dental insurance in China.
Jin Mei YANG ; Xing QU ; Xue Dong ZHOU ; Tao CHEN
Chinese Journal of Stomatology 2023;58(2):189-195
Oral diseases are highly prevalent in China, while oral health services are generally underutilized and public health resources are wasted. Lacking oral insurance may be one of the leading causes. The basic medical insurance of China does not cover dental care in most cities, which is worthy to further discuss. To better understand the experience of dental insurance from international dental care practice, the dental coverage scope, content, co-pay ratio, and effects of oral insurance on oral health improvement from the abroad countries with typical health insurance systems were summarized by using scoping review. Then, we discussed the coverage scope for dental health of basic medical insurance and private insurance in China. We also analyzed the current issues of dental care coverage and cost-share. At last, we proposed thoughts and suggestions to establish and improve a multi-level oral health insurance system with Chinese characteristics under the basic medical insurance frame. In particular, we gave suggestions on increasing the coverage for high dental care xpenditure by ebasic medical insurance, supplying children and teenagers with preventive dental care, and encouraging private insurance companies to cover dental care expenditure.
Child
;
Adolescent
;
Humans
;
Insurance, Dental
;
Dental Care
;
China
10.Efficacy and Safety of Pulse Magnetic Therapy System in Insomnia Disorder: A Multicenter, Randomized, Double-Blind, Placebo-Controlled Trial
Jiwu LIAO ; Sisi WANG ; Borong ZHOU ; Wei LIANG ; Ping MA ; Min LIN ; Weisen LIN ; Congrui LI ; Xiaotao ZHANG ; Hongyao LI ; Yin CUI ; Jiajia HU ; Yuanyi QIN ; Yanhua DENG ; Aibing FU ; Tianhua ZHU ; Shanlian ZHANG ; Yunhong QU ; Lu XING ; Wumei LI ; Fei FENG ; Xinping YAO ; Guimei ZHANG ; Jiyang PAN
Psychiatry Investigation 2023;20(6):559-566
Objective:
This study’s objective is to assess the efficacy and safety of Pulsed Magnetic Therapy System (PMTS) in improving insomnia disorder.
Methods:
Participants with insomnia disorder were randomly assigned to receive either PMTS or sham treatment for four weeks (n= 153; PMTS: 76, sham: 77). Primary outcomes are the Insomnia Severity Index (ISI) scores at week 0 (baseline), 1, 2, 3, 4 (treatment), and 5 (follow-up). Secondary outcomes are the Pittsburgh Sleep Quality Index at baseline and week 4, and weekly sleep diary-derived values for sleep latency, sleep efficiency, real sleep time, waking after sleep onset, and sleep duration.
Results:
The ISI scores of the PMTS group and the sham group were 7.13±0.50, 11.07±0.51 at week 4, respectively. There was a significant group×time interaction for ISI (F3.214, 485.271=24.25, p<0.001, ηp 2=0.138). Only the PMTS group experienced continuous improvement throughout the study; in contrast, the sham group only experienced a modest improvement after the first week of therapy. At the end of the treatment and one week after it, the response of the PMTS group were 69.7% (95% confidence interval [CI]: 58.6%–79.0%), 75.0% (95% CI: 64.1%–83.4%), respectively, which were higher than the response of the sham group (p<0.001). For each of the secondary outcomes, similar group×time interactions were discovered. The effects of the treatment persisted for at least a week.
Conclusion
PMTS is safe and effective in improving insomnia disorders.

Result Analysis
Print
Save
E-mail