1.Research status of AQP5 regulation of programmed cell death in chronic obstructive pulmonary disease
Cheng-Cai YUN ; Li-Ying ZHANG ; Hong-Dou HOU ; Huan-Huan ZHANG ; Zhang-Bo SONG ; Wen-Xing YONG
The Chinese Journal of Clinical Pharmacology 2024;40(14):2134-2138
Aquaporin 5(AQP5),as the main water transport protein in the body,can regulate lung diseases by regulating airway mucus secretion,pulmonary inflammation,and lung function.Programmed cell death(PCD)plays a crucial role in chronic obstructive pulmonary disease(COPD).AQP5 may affect the development of COPD by regulating PCDs.This article reviews the molecular regulatory mechanism of AQP5 on apoptosis,autophagy,iron death and pyroptosis in PCDs in recent years,and further discusses its effect on COPD in order to provide theoretical support for clinical prevention and treatment of COPD.
2.Compatibility Mechanism of Mineral Medicine Os Draconis in Bupleuri Radix-containing Tri-herbal Medicines Based on Supramolecular Systems
Zi XING ; Junling HOU ; Yifan ZHAO ; Liman XIAO ; Mengjia WEI ; Mengyuan YANG ; Lu YUN ; Yuanfei NIU ; Zhijie ZHANG
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(14):191-198
ObjectiveBy starting with the combination of Os Draconis, Bupleuri Radix, and Ostreae Concha, the role of mineral medicine Os Draconis in the combination of the Bupleuri Radix-containing tri-herbal medicines was preliminarily explored from the perspective of supramolecular system formation. Method① The appearance and Tyndall phenomenon of single decoction of Os Draconis, Bupleuri Radix, and Ostreae Concha, as well as co-decoction of Bupleuri Radix-Os Draconis, Bupleuri Radix-Os Draconis-Ostreae Concha, and Bupleuri Radix-Ostreae Concha were observed, and the average particle size, dispersion coefficient, and Zeta potential of suspension particles in each decoction were determined. The micromorphology of supramolecular structures was observed by scanning electron microscope (SEM). ② The pH of different compatibility systems, liquid viscosity coefficient, liquid surface tension, freeze-dried powder yield rate, and other physical properties were determined, and the interaction of different compatibility systems was detected by infrared absorption spectroscopy (FTIR) and UV-visible spectrophotometry (UV-Vis). ③ The composition and content difference of different compatible systems were determined by high-performance liquid chromatography (HPLC) and ultra-performance liquid chromatography-quadrupole-time of flight mass spectrometry (UPLC-Q-TOF-MS). ResultCompared with the single decoction, the co-decoction had more obvious turbidity and Tyndall phenomenon. The particles in the co-decoction suspension were smaller and more evenly distributed, and the Zeta potential was reduced, indicating a more stable system. Under SEM, Bupleuri Radix was irregularly lamellar, and Bupleuri Radix-Os Draconis and Bupleuri Radix-Os Draconis-Ostreae Concha were mainly spherical nanoparticles. Bupleuri Radix-Ostreae Concha was irregularly lamellar, with a small number of spherical nanoparticles. The pH of the single decoction of Bupleuri Radix and co-decoction increased, and the viscosity coefficient increased. The liquid surface tension decreased. The freeze-dried powder yield rate of the Bupleuri Radix-Os Draconis co-decoction was the highest, followed by Bupleuri Radix-Ostreae Concha decoction and Bupleuri Radix-Os Draconis-Ostreae Concha decoction, and the yield rate of Bupleuri Radix single decoction was the lowest. The main change of FTIR was the stretching vibration of -OH, and the co-decoction moved to the low-frequency direction obviously. UV-Vis showed that the maximum absorption occurred at 295.8 nm for all groups, and the absorption intensity was different (Bupleuri Radix-Os Draconis>Bupleuri Radix-Os Draconis-Ostreae Concha>Bupleuri Radix-Ostreae Concha>Bupleuri Radix). The components of Bupleuri Radix were used as the indexes, and the content of methanol extract determined by HPLC was higher than that of water extract, and the components of Bupleuri Radix single decoction were mainly saikosaponin a (SSa) and saikosaponin c (SSc), which were slightly higher after co-decoction compatibility. UPLC-Q-TOF-MS could identify 37 compounds in both single decoction and co-decoction. ConclusionThe combination of Bupleuri Radix, Os Draconis, and Ostreae Concha can form a smaller, more uniform, and stable nano-sized supramolecular system, which is conducive to the dissolution of the main components of Bupleuri Radix, and the Os Draconis contributes the most in this process.
3.Use of indocyanine green fluorescence navigation in laparoscopic anatomical hepatectomy.
Zi Qi HOU ; Qing Yun XIE ; Ming Heng LIAO ; Chang LIU ; Guo Teng QIU ; Zhao Xing JIN ; Shi Zheng MI ; Ji Wei HUANG
Chinese Journal of Surgery 2023;61(5):368-374
Objective: To examine the clinical value of fluorescence-guided indocyanine green (ICG) laparoscopic anatomical hepatectomy in the treatment of primary hepatocellular carcinoma. Methods: Data from patients diagnosed with hepatocellular carcinoma and who underwent laparoscopic hepatectomy with ICG fluorescence navigation in the Department of Liver Surgery and Liver Transplantation Center of West China Hospital between September 2020 and May 2022 were retrospectively collected. There were 53 males and 19 females, with an age of (55.5±12.9)years(range:42.6 to 68.4 years). Among them, 13 of the cases underwent laparoscopic anatomical liver resection(LALR) guided by tans-arterial ICG,43 of the cases received LAIR guided by portal vein negative ICG, and 16 of the cases received LALR positive by portal vein. Comparison among the three groups was performed by one-way ANOVA; and the rank sum test was used for comparison between groups. The counting data was expressed as percentage,and the χ2 test or Fisher's exact probability method was used for comparison between groups. Results: (1) Postoperative pathology: Resection R0 was achieved in all operations. The maximum tumor diameter of the patients in the arterial staining group, the reverse staining group, and the positive staining group(M (IQR)) was 2.5 (2.4) cm, 3.0 (2.5) cm and 3.0(2.4) cm,respectively. There were no statistically significant differences in the maximum tumor diameter between the three groups (P=0.364). The minimum tumor margin was 1.1 (1.1) cm, 1.0 (1.0) cm, 1.1 (1.6) cm in the the arterial staining group, reverse staining group and the positive staining group, respectively. There was no significant difference in the margin among the three groups (P=0.878). (2) Operation conditions: the operation time of the arterial staining group, the negative staining group, and the positive portal staining group was (348±93)minutes,(277±112)minutes,and (295±116)minutes,respectively. There were no significant differences in operation time among the three groups (P=0.134). The intraoperative blood loss of the three groups was 80(150)ml,200(350)ml,and 100(150)ml,respectively. There was no statistically significant difference in intraoperative bleeding volume between the three groups(P=0.743). All cases were not transfused during the operation and were not converted to laparotomy. ALT in the arterial staining group was higher than in the negative staining group in the first two days after the operation ((559±398)IU/L307(257) IU/L, q=235.5,P=0.004;(611±389)IU/L(331±242) IU/L, q=265.2, P=0.002). There was only one case of a grade III complication (Clavien-Dindo grading system) postoperative complication in the negative and positive staining group of the portal vein, respectively. Tumor markers in all patients decreased to the normal range after 2 months of operation. Conclusion: Laparoscopic anatomical hepatectomy guided by ICG fluorescence through arterial staining and portal vein staining is safe and feasible for primary hepatocellular carcinoma treatment.
4.Expert consensus for the clinical application of autologous bone marrow enrichment technique for bone repair (version 2023)
Junchao XING ; Long BI ; Li CHEN ; Shiwu DONG ; Liangbin GAO ; Tianyong HOU ; Zhiyong HOU ; Wei HUANG ; Huiyong JIN ; Yan LI ; Zhonghai LI ; Peng LIU ; Ximing LIU ; Fei LUO ; Feng MA ; Jie SHEN ; Jinlin SONG ; Peifu TANG ; Xinbao WU ; Baoshan XU ; Jianzhong XU ; Yongqing XU ; Bin YAN ; Peng YANG ; Qing YE ; Guoyong YIN ; Tengbo YU ; Jiancheng ZENG ; Changqing ZHANG ; Yingze ZHANG ; Zehua ZHANG ; Feng ZHAO ; Yue ZHOU ; Yun ZHU ; Jun ZOU
Chinese Journal of Trauma 2023;39(1):10-22
Bone defects caused by different causes such as trauma, severe bone infection and other factors are common in clinic and difficult to treat. Usually, bone substitutes are required for repair. Current bone grafting materials used clinically include autologous bones, allogeneic bones, xenografts, and synthetic materials, etc. Other than autologous bones, the major hurdles of rest bone grafts have various degrees of poor biological activity and lack of active ingredients to provide osteogenic impetus. Bone marrow contains various components such as stem cells and bioactive factors, which are contributive to osteogenesis. In response, the technique of bone marrow enrichment, based on the efficient utilization of components within bone marrow, has been risen, aiming to extract osteogenic cells and factors from bone marrow of patients and incorporate them into 3D scaffolds for fabricating bone grafts with high osteoinductivity. However, the scientific guidance and application specification are lacked with regard to the clinical scope, approach, safety and effectiveness. In this context, under the organization of Chinese Orthopedic Association, the Expert consensus for the clinical application of autologous bone marrow enrichment technique for bone repair ( version 2023) is formulated based on the evidence-based medicine. The consensus covers the topics of the characteristics, range of application, safety and application notes of the technique of autologous bone marrow enrichment and proposes corresponding recommendations, hoping to provide better guidance for clinical practice of the technique.
5.Study on formulation and revision of standard limits for radon in "Standards for indoor air quality (GB/T 18883-2022)" in China.
Yan Chao SONG ; Yun Yun WU ; Quan Fu SUN ; Chang Song HOU ; Bing SHANG ; Hong Xing CUI
Chinese Journal of Preventive Medicine 2023;57(11):1773-1776
Public exposure to radon has attracted increasing public concern. The newly issued "Standards for indoor air quality (GB/T 18883-2022)" has revised the radiological parameters of radon. This study analyzed and discussed the relevant technical contents about the derivation of radon limit, including the distribution level for indoor radon, exposure pathway, health effects, and the process for establishing the standard limits. Specific implementation and evaluation suggestions are also proposed.
Humans
;
Radon/analysis*
;
Air Pollution, Indoor
;
China
;
Housing
6.Study on formulation and revision of standard limits for radon in "Standards for indoor air quality (GB/T 18883-2022)" in China.
Yan Chao SONG ; Yun Yun WU ; Quan Fu SUN ; Chang Song HOU ; Bing SHANG ; Hong Xing CUI
Chinese Journal of Preventive Medicine 2023;57(11):1773-1776
Public exposure to radon has attracted increasing public concern. The newly issued "Standards for indoor air quality (GB/T 18883-2022)" has revised the radiological parameters of radon. This study analyzed and discussed the relevant technical contents about the derivation of radon limit, including the distribution level for indoor radon, exposure pathway, health effects, and the process for establishing the standard limits. Specific implementation and evaluation suggestions are also proposed.
Humans
;
Radon/analysis*
;
Air Pollution, Indoor
;
China
;
Housing
7.An axillary approach for open reduction and internal fixation to treat anterior glenoid fracture: an anatomical and clinical study
Yong XING ; Ziyan ZHANG ; Yan GUO ; Guojin HOU ; Jian DING ; Dankai WU ; Yun TIAN
Chinese Journal of Orthopaedics 2022;42(1):18-25
Objective:To investigate the clinical effect and safety of reduction and fixation for the anterior glenoid fracture through an axillary approach.Methods:Two autopsy specimens (a total of 4 shoulder joints) were used to simulate the surgery of open reduction and internal fixation to treat anterior glenoid fracture through an axillary approach. Specimens were placed in the lateral decubitus position. An incision was made in the posterior axillary line to expose the lateral side of the scapula through the interval ahead of the latissimus dorsi muscle. Attended to the separation and protection of the axillary nerve, posterior humerus artery, thoracic dorsal nerve, and scapular artery. The surgical area of the axillary approach was divided into the upper "quadrilateral area" and the lower "trilateral area", which exposed the anteroinferior glenoid, neck, and the full length of lateral border of the scapula. Thirteen cases (7 males and 6 females) were involved in this study, all patients were diagnosed with anterior glenoid fracture and treated by open reduction and internal fixation through the axillary approach between April 2018 and December 2020. Constant-Murley score and Disabilities of the Arm, Shoulder and Hand (DASH) were used to evaluate the clinical efficacy.Results:Thirteen patients were enrolled for final analysis, which included 12 right cases and 1 left case. The average age was 50.38±13.74 years (range 24-67 years). All 13 patients were classified as Ideberg type Ia fracture. Anatomical buttress plates were used in 5 cases, cannulated screws combined with metacarpal plates in 7 cases, and distal radius plate in 1 case. The average length of follow-up was 13.00±5.97 months (range 6-26 months). No delayed union or malunion in all cases at the last follow-up visits. The average of Constant-Murley score was 62.46±10.26 points (range 45-83) and the DASH score was 27.56±9.76 points (range 14.14-43.33) at the three months follow up visits. At 6 months postoperatively, the Constant-Murley score was 80.85±8.32 points (range 65 to 90) and the DASH score was 11.47±8.56 points (range 0 to 35.00). Constant-Murley score at the final patient's follow-up visit was 84.54±8.95 points (range 70-95), and the DASH score was 10.94±8.67 points (range 1.67 to 33.33 points). The joint function gradually recovered with time. The functional scores at 3 months, 6 months after surgery, and final follow-up visit had significant differences ( P<0.05). Conclusion:The axillary approach is a safe and feasible approach for the treatment of the anterior glenoid fracture. This approach exposes the anteroinferior glenoid and the lateral border of the scapula, which reduces rotator-cuff injury and achieves anatomic reduction and strong fixation of the fracture. The axillary approach surgery also allows early functional physiotherapy after surgery.
8.Clinical effects of 3D printed porous titanium-alloy prosthesis in reconstruction of long bone defects of lower extremities
Bingchuan LIU ; Xingcai LI ; Weipeng QIU ; Yong XING ; Zhongwei YANG ; Guojin HOU ; Zhongjun LIU ; Fang ZHOU ; Yufeng ZHENG ; Peng WEN ; Yun TIAN
Chinese Journal of Orthopaedics 2022;42(10):626-634
Objective:To analyze and summarize the clinical effects of 3D printed porous titanium-alloy prosthesis implantation in the treatment of long bone defects of lower extremities.Methods:We retrospectively studied the clinical cases with lower extremity bone defect treated by 3D printed porous titanium prostheses from December 2017 to November 2021. 18 patients who were followed up for more than 12 months were included in this study. The enrolled patients included 12 males and 6 females, with an average of 48.9±22.5 years (range, 13-79 years), and an average body mass index of 23.1±4.3 kg/m 2 (range, 17.2-27.1 kg/m 2). There were 14 osteomyelitis-derived bone defects and 4 nonunion-derived bone defects. The bone defect locations included 10 cases of femur and 8 cases of tibia. The average bone defect distance was 13.9±9.7 cm (range, 5.8-31.2 cm), and the proportion of the defect length to the long bone (femur of tibia) was average 33.7%±16.8% (range, 15.0%-63.0%). The clinical efficacy was comprehensively evaluated through gross observation, imaging evaluation, changes in the total length of lower extremities and long bones, femorotibial angle (FTA) measurement, lower extremity functional scale (LEFS), satisfaction, complications and other indicators, focusing on the stabilization mechanism of the prosthesis and the regeneration of new bone. Results:All 18 patients were followed up for 12-35 months, with an average of 16.3 months. Postoperative X-rays at 1, 3, 12 and 24 months showed that new bone could gradually creep along the prosthesis surface. The preoperative bone defect length of long bone and total length of lower limb were respectively 39.4±4.0 cm and 80.5±5.7 cm, which were different from those of the healthy side by 1.6±1.0 cm and 1.5±1.1 cm. One week after implantation, the length of long bone and lower limb was 39.9±3.5 cm and 80.9±6.2 cm, respectively, and the average difference was 1.0±0.6 cm and 0.9±1.1 cm compared with the healthy side. At the last follow-up, the length of long bone and lower limb was 39.7±3.6 cm and 80.9±7.8 cm, with an average difference of 1.8±1.1 cm and 1.0±0.7 cm from the healthy side. There were no significant differences in the length of long bone and lower limbs at the three time points before surgery, one week after surgery and the last follow-up ( F=0.12, 0.04; P>0.05). The average FTA of the affected limb was 174.7° (173.9°, 175.5°), 175.2°(173.5°, 176.4°), and 175.0°(173.5°, 176.3°) at three time nodes, before surgery, one week after surgery and the last follow-up, respectively, and there was no significant statistical difference in pairwise comparison ( Z=0.01, P>0.05). Patients had a mean LEFS score of 50 (46, 51) at the last follow-up, significantly higher than the preoperative score of 20 (17, 21) ( Z=-5.56, P<0.001). The mean satisfaction score of the 18 patients at the last follow-up was 9.7. Two patients (11.1%) had screw fractures but all 3D printed porous titanium alloy prostheses remained stable without significant loosening or displacement. Two patients (11.1%) had nail channel infection of external fixator, all patients with channel infection were cured by intravenous antibiotics combined with local disinfection and dressing change. Conclusion:The implantation of 3D printed porous titanium-alloy prosthesis could efficiently and safely repair the long bone defects of the lower extremities. The prosthesis could maintain stable in the early and middle postoperative period. The length of the long bones and lower limbs did not change significantly with the weight-bearing and functional exercise of the limbs. The new bone could gradually crawl and grow from both ends of the defect, and the patient's limb function recovered significantly, and the patient's satisfaction was high.
9.Clinical effects of proximal ulnar artery perforator flap combined with iliac bone graft in the reconstruction of subtotal thumb or finger defects.
Yu Jun ZHANG ; Ji Hui JU ; Qiang ZHAO ; Ben Yuan WANG ; He Yun CHENG ; Gui Yang WANG ; Rui Xing HOU
Chinese Journal of Burns 2022;38(10):959-963
Objective: To explore the clinical effects of proximal ulnar artery perforator flap combined with iliac bone graft in the reconstruction of subtotal thumb or finger defects. Methods: A retrospective observational study was conducted. From August 2016 to August 2019, 7 patients with thumb or finger defects caused by mechanical damage who met the inclusion criteria were admitted to Ruihua Affiliated Hospital of Soochow University, including 6 males and 1 female, aged 46 to 58 years. Their length of fingers was repaired with iliac bone, with length of 2.0 to 3.0 cm. After the bone graft, the skin defect area of the affected finger ranged from 2.8 cm×2.2 cm to 6.0 cm×3.2 cm. Then the free proximal ulnar artery perforator flap with area of 3.0 cm×2.4 cm to 6.5 cm×3.5 cm was used to cover the wounds. The wounds in donor sites of iliac crest and flap were directly sutured. The survival of flap in one week post surgery and the donor site wound healing in 2 weeks post surgery were observed, respectively. During the follow-up, the appearance and sensory function of the affected finger, bone healing, and scar hypertrophy of wound in the donor site were observed and evaluated. At the last follow-up, the functional recovery of the affected finger was evaluated with trial standard for the evaluation of functions of the upper limbs of the Hand Surgery Society of Chinese Medical Association. Results: In one week post surgery, all the flaps survived. In 2 weeks post surgery, the iliac bone and the wounds in forearm donor site healed. During the follow-up of 5 to 13 months, the flap was good in appearance, without obvious pigmentation; the sensory recovery reached level S2 in 5 patients and S0 in 2 patients; all the grafted iliac bones were bony union without obvious resorption; the wounds in donor site healed well, with only mild scar formation. At the last follow-up, the shape of the reconstructed finger was close to the healthy finger, and the functional evaluation results were excellent in 3 cases and good in 4 cases. Conclusions: The use of proximal ulnar artery perforator flap combined with iliac bone graft to reconstruct subtotal thumb or finger can partially restore part of the appearance and function, with less damage to the donor site. It is a good choice for patients who have low expectations of appearance and function for the reconstructed finger.
Male
;
Humans
;
Female
;
Soft Tissue Injuries/surgery*
;
Perforator Flap/transplantation*
;
Skin Transplantation/methods*
;
Thumb/surgery*
;
Plastic Surgery Procedures
;
Ulnar Artery/surgery*
;
Cicatrix/surgery*
;
Ilium/surgery*
;
Treatment Outcome
10.3- to 24-month Follow-up on COVID-19 with Pulmonary Tuberculosis Survivors after Discharge: Results from a Prospective, Multicenter Study
Ya Jing WANG ; Yu Xing ZONG ; Hui Gui WU ; Lin Yuan QI ; Zhen Hui LI ; Yu Xin JI ; Lin TONG ; Lei ZHANG ; Bo Ming YANG ; Ye Pu YANG ; Ke Ji LI ; Rong Fu XIAO ; Song Lin ZHANG ; Hong Yun HU ; De Hong LIU ; Fang Shou XU ; Sheng SUN ; Wei WU ; Ya MAO ; Qing Min LI ; Hua Hao HOU ; Yuan Zhao GONG ; Yang GUO ; Wen Li JIAO ; Jin QIN ; Yi Ding WANG ; Fang WANG ; Li GUAN ; Gang LIN ; Yan MA ; Ping Yan WANG ; Nan Nan SHI
Biomedical and Environmental Sciences 2022;35(12):1091-1099
Objective Coronavirus disease 2019 (COVID-19) and tuberculosis (TB) are major public health and social issues worldwide. The long-term follow-up of COVID-19 with pulmonary TB (PTB) survivors after discharge is unclear. This study aimed to comprehensively describe clinical outcomes, including sequela and recurrence at 3, 12, and 24 months after discharge, among COVID-19 with PTB survivors. Methods From January 22, 2020 to May 6, 2022, with a follow-up by August 26, 2022, a prospective, multicenter follow-up study was conducted on COVID-19 with PTB survivors after discharge in 13hospitals from four provinces in China. Clinical outcomes, including sequela, recurrence of COVID-19, and PTB survivors, were collected via telephone and face-to-face interviews at 3, 12, and 24 months after discharge. Results Thirty-two COVID-19 with PTB survivors were included. The median age was 52 (45, 59) years, and 23 (71.9%) were men. Among them, nearly two-thirds (62.5%) of the survivors were moderate, three (9.4%) were severe, and more than half (59.4%) had at least one comorbidity (PTB excluded). The proportion of COVID-19 survivors with at least one sequela symptom decreased from 40.6% at 3 months to 15.8% at 24 months, with anxiety having a higher proportion over a follow-up. Cough and amnesia recovered at the 12-month follow-up, while anxiety, fatigue, and trouble sleeping remained after 24 months. Additionally, one (3.1%) case presented two recurrences of PTB and no re-positive COVID-19 during the follow-up period. Conclusion The proportion of long symptoms in COVID-19 with PTB survivors decreased over time, while nearly one in six still experience persistent symptoms with a higher proportion of anxiety. The recurrence of PTB and the psychological support of COVID-19 with PTB after discharge require more attention.

Result Analysis
Print
Save
E-mail