1.Application of CRISPR/Cas System in Precision Medicine for Triple-negative Breast Cancer
Hui-Ling LIN ; Yu-Xin OUYANG ; Wan-Ying TANG ; Mi HU ; Mao PENG ; Ping-Ping HE ; Xin-Ping OUYANG
Progress in Biochemistry and Biophysics 2025;52(2):279-289
Triple-negative breast cancer (TNBC) represents a distinctive subtype, characterized by the absence of estrogen receptors, progesterone receptors, and human epidermal growth factor receptor 2 (HER2). Due to its high inter-tumor and intra-tumor heterogeneity, TNBC poses significant chanllenges for personalized diagnosis and treatment. The advant of clustered regular interspaced short palindromic repeats (CRISPR) technology has profoundly enhanced our understanding of the structure and function of the TNBC genome, providing a powerful tool for investigating the occurrence and development of diseases. This review focuses on the application of CRISPR/Cas technology in the personalized diagnosis and treatment of TNBC. We begin by discussing the unique attributes of TNBC and the limitations of current diagnostic and treatment approaches: conventional diagnostic methods provide limited insights into TNBC, while traditional chemotherapy drugs are often associated with low efficacy and severe side effects. The CRISPR/Cas system, which activates Cas enzymes through complementary guide RNAs (gRNAs) to selectively degrade specific nucleic acids, has emerged as a robust tool for TNBC research. This technology enables precise gene editing, allowing for a deeper understanding of TNBC heterogeneity by marking and tracking diverse cell clones. Additionally, CRISPR facilitates high-throughput screening to promptly identify genes involved in TNBC growth, metastasis, and drug resistance, thus revealing new therapeutic targets and strategies. In TNBC diagnostics, CRISPR/Cas was applied to develop molecular diagnostic systems based on Cas9, Cas12, and Cas13, each employing distinct detection principles. These systems can sensitively and specifically detect a variety of TNBC biomarkers, including cell-specific DNA/RNA and circulating tumor DNA (ctDNA). In the realm of precision therapy, CRISPR/Cas has been utilized to identify key genes implicated in TNBC progression and treatment resistance. CRISPR-based screening has uncovered potential therapeutic targets, while its gene-editing capabilities have facilitated the development of combination therapies with traditional chemotherapy drugs, enhancing their efficacy. Despite its promise, the clinical translation of CRISPR/Cas technology remains in its early stages. Several clinical trials are underway to assess its safety and efficacy in the treatment of various genetic diseases and cancers. Challenges such as off-target effects, editing efficiency, and delivery methods remain to be addressed. The integration of CRISPR/Cas with other technologies, such as 3D cell culture systems, human induced pluripotent stem cells (hiPSCs), and artificial intelligence (AI), is expected to further advance precision medicine for TNBC. These technological convergences can offer deeper insights into disease mechanisms and facilitate the development of personalized treatment strategies. In conclusion, the CRISPR/Cas system holds immense potential in the precise diagnosis and treatment of TNBC. As the technology progresses and becomes more costs-effective, its clinical relevance will grow, and the translation of CRISPR/Cas system data into clinical applications will pave the way for optimal diagnosis and treatment strategies for TNBC patients. However, technical hurdles and ethical considerations require ongoing research and regulation to ensure safety and efficacy.
2.Research and Application of Scalp Surface Laplacian Technique
Rui-Xin LUO ; Si-Ying GUO ; Xin-Yi LI ; Yu-He ZHAO ; Chun-Hou ZHENG ; Min-Peng XU ; Dong MING
Progress in Biochemistry and Biophysics 2025;52(2):425-438
Electroencephalogram (EEG) is a non-invasive, high temporal-resolution technique for monitoring brain activity. However, affected by the volume conduction effect, EEG has a low spatial resolution and is difficult to locate brain neuronal activity precisely. The surface Laplacian (SL) technique obtains the Laplacian EEG (LEEG) by estimating the second-order spatial derivative of the scalp potential. LEEG can reflect the radial current activity under the scalp, with positive values indicating current flow from the brain to the scalp (“source”) and negative values indicating current flow from the scalp to the brain (“sink”). It attenuates signals from volume conduction, effectively improving the spatial resolution of EEG, and is expected to contribute to breakthroughs in neural engineering. This paper provides a systematic overview of the principles and development of SL technology. Currently, there are two implementation paths for SL technology: current source density algorithms (CSD) and concentric ring electrodes (CRE). CSD performs the Laplace transform of the EEG signals acquired by conventional disc electrodes to indirectly estimate the LEEG. It can be mainly classified into local methods, global methods, and realistic Laplacian methods. The global method is the most commonly used approach in CSD, which can achieve more accurate estimation compared with the local method, and it does not require additional imaging equipment compared with the realistic Laplacian method. CRE employs new concentric ring electrodes instead of the traditional disc electrodes, and measures the LEEG directly by differential acquisition of the multi-ring signals. Depending on the structure, it can be divided into bipolar CRE, quasi-bipolar CRE, tripolar CRE, and multi-pole CRE. The tripolar CRE is widely used due to its optimal detection performance. While ensuring the quality of signal acquisition, the complexity of its preamplifier is relatively acceptable. Here, this paper introduces the study of the SL technique in resting rhythms, visual-related potentials, movement-related potentials, and sensorimotor rhythms. These studies demonstrate that SL technology can improve signal quality and enhance signal characteristics, confirming its potential applications in neuroscientific research, disease diagnosis, visual pathway detection, and brain-computer interfaces. CSD is frequently utilized in applications such as neuroscientific research and disease detection, where high-precision estimation of LEEG is required. And CRE tends to be used in brain-computer interfaces, that have stringent requirements for real-time data processing. Finally, this paper summarizes the strengths and weaknesses of SL technology and envisages its future development. SL technology boasts advantages such as reference independence, high spatial resolution, high temporal resolution, enhanced source connectivity analysis, and noise suppression. However, it also has shortcomings that can be further improved. Theoretically, simulation experiments should be conducted to investigate the theoretical characteristics of SL technology. For CSD methods, the algorithm needs to be optimized to improve the precision of LEEG estimation, reduce dependence on the number of channels, and decrease computational complexity and time consumption. For CRE methods, the electrodes need to be designed with appropriate structures and sizes, and the low-noise, high common-mode rejection ratio preamplifier should be developed. We hope that this paper can promote the in-depth research and wide application of SL technology.
3.Study of adsorption of coated aldehyde oxy-starch on the indexes of renal failure
Qian WU ; Cai-fen WANG ; Ning-ning PENG ; Qin NIE ; Tian-fu LI ; Jian-yu LIU ; Xiang-yi SONG ; Jian LIU ; Su-ping WU ; Ji-wen ZHANG ; Li-xin SUN
Acta Pharmaceutica Sinica 2025;60(2):498-505
The accumulation of uremic toxins such as urea nitrogen, blood creatinine, and uric acid of patients with renal failure
4.Relationship between ocular parameters and lens thickness in myopic patients with varying anterior chamber depth
International Eye Science 2025;25(5):826-830
AIM:To study the relationship between ocular parameters and lens thickness(LT)in myopic patients with different anterior chamber depth(ACD).METHODS:Cross-sectional study. A total of 118 myopic subjects(236 eyes)underwent posterior chamber phakic implantable collamer lens(Phakic-ICL)implantation in the refractive department of our hospital from May 2022 to May 2024 were selected. Ocular parameters examined before surgery included uncorrected visual acuity(UCVA), subjective refraction, best corrected visual acuity(BCVA), contactless intraocular pressure(IOP), ACD, white-to-white(WTW), horizontal sulcus-to-sulcus(STSH), vertical sulcus-to-sulcus(STSV), and LT. ACD without corneal thickness was measured by Pentacam, and subjects were divided into three groups: shallow anterior chamber group(2.8 mm≤ACD≤3.2 mm), middle anterior chamber group(3.2 mm
5.Progress in R&D and key issues in industrial advancement of Cistanches Herba products.
Shuo YUAN ; Yu-Ling XIAO ; Jia-Xu SUN ; Jun LEI ; Jia-Xin HONG ; Peng-Fei TU ; Yong JIANG
China Journal of Chinese Materia Medica 2025;50(13):3815-3840
Cistanches Herba(CH) is a famous tonic traditional Chinese medicine, with the effects of tonifying kidney Yang, nourishing kidney Yin, replenishing essence and blood, and moistening the intestines to relieve constipation. Modern pharmacological studies have shown that CH has anti-aging, anti-fatigue, immunomodulatory, neuroprotective, and anti-aging activities, serving as an ideal raw material for the development of pharmaceuticals and health products. In 2023, CH was added in the catalog of medicinal and food substances, which provided policy support for its application in conventional food products and expanding pathways for industrial diversification. To comprehensively understand current development status of CH products, this review systematically investigated professional databases including Yaozhi(https://db.yaozh.com), Chinese Pharmacopoeia, Compendium of National Standards for Chinese Patent Medicines, and Kezhuang and collected market survey data to thoroughly review the applications of CH as a primary ingredient in domestic and international Chinese patent medicines, health foods, cosmetics, and common food products. Furthermore, this review points out challenges in the current industrial development and future potential market prospects, aiming to provide guidance for the development and industrialization of CH-based pharmaceuticals and health products, thereby promoting the vigorous growth of the CH industry.
Drugs, Chinese Herbal/pharmacology*
;
Humans
;
Cistanche/chemistry*
;
Animals
;
Medicine, Chinese Traditional
6.Preparation of baicalin-berberine complex nanocrystal enteric microspheres and pharmacodynamic evaluation of ulcerative colitis treatment in rats.
Xiao-Chao HUANG ; Yi-Wen HU ; Peng-Yu SHEN ; Rui-Hong JIAN ; Dong-Li QI ; Zhi-Dong LIU ; Jia-Xin PI
China Journal of Chinese Materia Medica 2025;50(15):4263-4274
To enhance the therapeutic efficacy of the baicalin-berberine complex(BA-BBR) in the treatment of ulcerative colitis(UC), BA-BBR nanocrystal microspheres(BA-BBR NC MS) were prepared using the dropping method. The microspheres were characterized in terms of morphology, particle size, differential scanning calorimetry(DSC), and powder X-ray diffraction(XRD). The release profiles of BA and BBR from the microspheres were measured, and the drug release mechanism was investigated. A rat model of UC was induced by 5% dextran sodium sulfate(DSS) and treated continuously for 7 days to evaluate the therapeutic effects of different formulations. The results showed that the prepared BA-BBR MS and BA-BBR NC MS were uniform gel spheres with particle sizes of(1.77±0.16) mm and(1.67±0.08) mm, respectively. After drying, the gels collapsed inward and exhibited a rough surface. During the preparation process, the BA-BBR nanocrystals(BA-BBR NC) were uniformly encapsulated within the microspheres. The release profiles of the microspheres followed a first-order kinetic model, and the 12-hour cumulative release of BA and BBR from BA-BBR NC MS was higher than that from BA-BBR MS. Compared with BA-BBR, BA-BBR NC, and BA-BBR MS, BA-BBR NC MS further alleviated UC symptoms in rats, most significantly reducing the levels of TNF-α, IL-1β, IL-6, and MPO, while increasing the level of IL-4 in colon tissues. These results indicate that BA-BBR NC MS, based on a "nano-in-micro" design, can deliver BA-BBR to the intestine and exert significant therapeutic effects in a UC rat model, suggesting it as a promising new strategy for the treatment of UC.
Animals
;
Colitis, Ulcerative/metabolism*
;
Rats
;
Nanoparticles/chemistry*
;
Microspheres
;
Male
;
Berberine/administration & dosage*
;
Flavonoids/administration & dosage*
;
Rats, Sprague-Dawley
;
Drugs, Chinese Herbal/administration & dosage*
;
Humans
;
Particle Size
;
Tumor Necrosis Factor-alpha/immunology*
;
Drug Liberation
;
Drug Compounding
7.Evidence evaluation of 12 commonly-used Chinese patent medicines in treatment of osteoporosis based on Eff-iEC and GRADE.
Guang-Cheng WEI ; Zhi-Long ZHANG ; Xin-Wen ZHANG ; Ye LUO ; Jin-Jie SHI ; Rui MA ; Jie-Yang DU ; Ke ZHU ; Jiu-Cheng PENG ; Yu-Long YA ; Wei CAO
China Journal of Chinese Materia Medica 2025;50(15):4372-4385
This study applied the grading of recommendations assessment, development and evaluation(GRADE) system and the integrated evidence chain-based effectiveness evaluation of traditional Chinese medicine(Eff-iEC) to evaluate the evidence for 12 commonly used Chinese patent medicines for the treatment of osteoporosis, which are frequently recommended in guidelines or expert consensuses. The results showed that Xianling Gubao Capsules/Tablets were rated as C(low-level evidence) according to the GRADE system, and as BA~+B~+(intermediate evidence) according to the Eff-iEC system. Jintiange Capsules were rated as C(low-level evidence) by the GRADE system, and as AA~+B(high-level evidence) by the Eff-iEC system. Gushukang Granules/Capsules were rated as C(low-level evidence) by GRADE system, and as BA~+B~+(intermediate evidence) by Eff-iEC system. Zuogui Pills were rated as C(low-level evidence) by GRADE system, and as AA~(++)B~+(high-level evidence) by Eff-iEC system. Qianggu Capsules were rated as D(extremely low-level evidence) by GRADE system, and as AA~+B~+(high-level evidence) by Eff-iEC system. Zhuanggu Zhitong Capsules were rated as D(extremely low-level evidence) by GRADE system, and as BA~+B(intermediate evidence) by Eff-iEC system. Jingui Shenqi Pills were rated as D(extremely low-level evidence) by GRADE system, and as AA~+B(high-level evidence) by Eff-iEC system. Quanduzhong Capsules were rated as D(extremely low-level evidence) by GRADE system, and as AD~+B~+(low-level evidence) by Eff-iEC system. Epimedium Total Flavones Capsules were rated as D(extremely low-level evidence) by GRADE system, and as AAB~+(high-level evidence) by Eff-iEC system. Yougui Pills were rated as D(extremely low-level evidence) by GRADE system, and as AA~(++)B~(+ )(high-level evidence) by Eff-iEC system. Qigu Capsules were rated as D(extremely low-level evidence) by GRADE system, and as BB~+B(intermediate evidence) by Eff-iEC system. Liuwei Dihuang Pills were rated as C(low-level evidence) by GRADE system, and as AA~(++)B~+(high-level evidence) by Eff-iEC system. Overall, the Eff-iEC system provides a more comprehensive assessment of the effectiveness evidence for traditional Chinese medicine(TCM) than the GRADE system. However, it still has certain limitations that hinder its wider promotion and application. In terms of clinical evidence evaluation, both the Eff-iEC and GRADE systems reflect that the current clinical research quality on Chinese patent medicines for the treatment of osteoporosis is generally low. High-quality clinical trials are still needed in the future to further validate clinical efficacy.
Drugs, Chinese Herbal/therapeutic use*
;
Osteoporosis/drug therapy*
;
Humans
;
Nonprescription Drugs/therapeutic use*
;
Evidence-Based Medicine
;
Medicine, Chinese Traditional
8.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
9.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
10.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.

Result Analysis
Print
Save
E-mail