1.Neoadjuvant Chemotherapy and Neoadjuvant Chemotherapy With Immunotherapy Result in Different Tumor Shrinkage Patterns in TripleNegative Breast Cancer
Jiachen ZOU ; Liulu ZHANG ; Yuanqi CHEN ; Yingyi LIN ; Minyi CHENG ; Xingxing ZHENG ; Xiaosheng ZHUANG ; Kun WANG
Journal of Breast Cancer 2024;27(1):27-36
Purpose:
This study aims to explore whether neoadjuvant chemotherapy with immunotherapy (NACI) leads to different tumor shrinkage patterns, based on magnetic resonance imaging (MRI), compared to neoadjuvant chemotherapy (NAC) alone in patients with triple-negative breast cancer (TNBC). Additionally, the study investigates the relationship between tumor shrinkage patterns and treatment efficacy was investigated.
Methods:
This retrospective study included patients with TNBC patients receiving NAC or NACI from January 2019 until July 2021 at our center. Pre- and post-treatment MRI results were obtained for each patient, and tumor shrinkage patterns were classified into three categories as follows: 1) concentric shrinkage (CS); 2) diffuse decrease; and 3) no change.Tumor shrinkage patterns were compared between the NAC and NACI groups, and the relevance of the patterns to treatment efficacy was assessed.
Results:
Of the 99 patients, 65 received NAC and 34 received NACI. The CS pattern was observed in 53% and 20% of patients in the NAC and NACI groups, respectively. Diffuse decrease pattern was observed in 36% and 68% of patients in the NAC and NACI groups. The association between the treatment regimens (NAC and NACI) and tumor shrinkage patterns was statistically significant (p = 0.004). The postoperative pathological complete response (pCR) rate was 45% and 82% in the NAC and NACI groups (p < 0.001), respectively. In the NACI group, 17% of patients with the CS pattern and 56% of those with the diffuse decrease pattern achieved pCR (p = 0.903). All tumor shrinkage patterns were associated with achieved a high pCR rate in the NACI group.
Conclusion
Our study demonstrates that the diffuse decrease pattern of tumor shrinkage is more common following NACI than that following NAC. Furthermore, our findings suggest that all tumor shrinkage patterns are associated with a high pCR rate in patients with TNBC treated with NACI.
2.Erratum: Analysis of Tau Protein Expression in Predicting Pathological Complete Response to Neoadjuvant Chemotherapy in Different Molecular Subtypes of Breast Cancer
Chuqian LEI ; Ciqiu YANG ; Bin XIA ; Fei JI ; Yi ZHANG ; Hongfei GAO ; Qianqian XIONG ; Yufeng LIN ; Xiaosheng ZHUANG ; Liulu ZHANG ; Teng ZHU ; Minyi CHENG ; Mei YANG ; Kun WANG
Journal of Breast Cancer 2020;23(2):230-231
This corrects the article “Analysis of Tau Protein Expression in Predicting Pathological Complete Response to Neoadjuvant Chemotherapy in Different Molecular Subtypes of Breast Cancer” in volume 23 on page 47.This article was initially published on the Journal of Breast Cancer with a misspelled the abbreviation in figure 3. The abbreviation ‘HP’ should be corrected as ‘HR’.
3.Analysis of Tau Protein Expression in Predicting Pathological Complete Response to Neoadjuvant Chemotherapy in Different Molecular Subtypes of Breast Cancer
Chuqian LEI ; Ciqiu YANG ; Bin XIA ; Fei JI ; Yi ZHANG ; Hongfei GAO ; Qianqian XIONG ; Yufeng LIN ; Xiaosheng ZHUANG ; Liulu ZHANG ; Teng ZHU ; Minyi CHENG ; Mei YANG ; Kun WANG
Journal of Breast Cancer 2020;23(1):47-58
PURPOSE:
Tau is a microtubule-associated protein that can be found in both normal and abnormal breast cells. Whether the expression of Tau protein can predict the response to neoadjuvant chemotherapy (NACT) is still unclear. In this study, we assessed the role of Tau protein expression in predicting a pathological complete response (pCR) to NACT for different subtypes of breast cancer.
METHODS:
Four hundred and sixty-eight eligible patients were retrospectively recruited in our study. The relationship between clinicopathologic factors, including Tau protein expression, and pCR in different subtypes was evaluated using logistic regression analysis. Correlation between Tau and disease-free survival (DFS) and overall survival (OS) was performed using Kaplan–Meier analysis.
RESULTS:
The expression of Tau protein was negatively correlated with pCR, especially in triple-negative breast cancer (TNBC). No significant difference was observed in the luminal human epidermal growth factor receptor-2 (HER2)-negative subtype and HER2-positive subtype. Patients with pCR were associated with better DFS and OS (p < 0.05). However, Tau protein expression had no association with either DFS or OS (p > 0.05).
CONCLUSION
Tau protein expression can predict pCR before NACT in TNBC, but there was no correlation between Tau expression and DFS or OS.
4.Role of 3.0 T MR vessel wall imaging for identifying the activity of Takayasu arteritis
Xiaosheng LIU ; Jianrong XU ; Huilin ZHAO ; Fang CHENG ; Qing LU ; Qiuying YAO
Chinese Journal of Radiology 2010;44(1):44-47
Objective To analyze and explore the value of 3 T high resolution magnetic resonance vessel wall imaging for identifying the activity of Takayasu arteritis. Methods Twenty-six consecutive patients with Takayasu arteritis underwent 3.0 T high resolution MR vessel wall imaging on supraortic vessels (according to the classification of Lupi-Herrea , type Ⅰ and Ⅲ were included). Sixteen patients were in active phase and 10 in inactive phase based on the Kerr criteria. The MR vessel wall imaging appearances of Takayasu arteritis were compared between the active phase and inactive phase cases. Results Wall thickening was demonstrated in all involved arteries. There were statistically significant differences between active phase and inactive phase cases in MR appearances including multi-ring thickening of vessel wall (75/80 and 18/50), arterial inner wail enhancement (50/80 and 19/50), obscurity of perivascular fat (55/80 and 18/50,X<'2>=50.39,7.41,13.40,P<0.01). There was also a statistically significant difference in the thickness of carotid artery wall between the two groups [ (3.8±0.2) mm vs (2.5±0.8) mm]. Conclusion 3 T high resolution MR vessel wall imaging is valuable for identifying the activity of Takayasu arteritis.
5.Computer aided design and manufacture of the removable partial denture framework.
Leilei YANG ; Xiaosheng CHENG ; Ning DAI ; Senyang ZHU ; Guodong YAN ; Yiguo GAO
Journal of Biomedical Engineering 2010;27(1):170-173
This paper demonstrates the successful application of a novel approach to the computer aided design (CAD) of removable partial denture (RPD) framework. Firstly, we get the data of the partially edentulous cast, a mandibular Kennedy Class II, through a 3D-optical grating measuring system after corresponding pretreatment. Then, the reverse engineering software and 3D CAD software was used to design basis, big conjunction, clasp, small conjunction of the RPD framework. Finally 3D surface model of the RPD framework was created in preparation for direct manufacture using rapid prototyping (RP) methods and foundry. The result indicated that the RPD framework was fabricated successfully and the resulting frameworks provided a satisfactory fit.
Computer-Aided Design
;
Dental Alloys
;
Dental Casting Technique
;
Dental Prosthesis Design
;
methods
;
Denture Design
;
methods
;
Denture, Partial, Removable
;
Humans
6.Clinical study of combination of mini-percutaneous nephrolithotomy and ureteroscopic lithotripsy in the treatment of non-hydronephrotic staghorn calculi
Xinli YU ; Ronghai WU ; Jian PANG ; Lixin CHEN ; Yongbin LIAO ; Xiaosheng HUANG ; Zhouping CHENG ; Qiping LIN ; Ming SUN
Chinese Journal of Postgraduates of Medicine 2009;32(11):6-8
Objective To assess the safety and the curative effect of the combination of minipercutaneous nephrolithotomy (mini-PCNL) and ureteroscopic lithotripsy (URL) in the treatment of nonhydronephrotic staghorn calculi. Methods The clinical data of 53 eases with non-hydronephrotic staghom calculi treated by mini-PCNL combined with URL were retrospectively analyzed. Results Fifty-three cases (64 renal units) were performed first-stsge operation, 9 renal units were stone free in first-stage operation, 33 renal units were stone free in second-stage operation, other 13 renal units were stone free in third-stage operation. A complete stone clearance rate of 85.9%(55/64) was achieved, and after one to three sessions of mini-PCNL and extracorpereal shock wave lithotripsy afterwards that increased to 95.3% (61/64). Blood transfusion was performed in 3 cases, no major complication was noted in the patients. Conclusions The combination of mini-PCNL and URL has more advantages, less invasions, easier recovery and less complications. It provides a new minimally invasive way for non-hydronephrotic staghorn calculi.
7.Establishment of database with standard 3D tooth crowns based on 3DS MAX.
Xiaosheng CHENG ; Tao AN ; Wenhe LIAO ; Ning DAI ; Qing YU ; Peijun LU
Journal of Biomedical Engineering 2009;26(4):866-868
The database with standard 3D tooth crowns has laid the groundwork for dental CAD/CAM system. In this paper, we design the standard tooth crowns in 3DS MAX 9.0 and create a database with these models successfully. Firstly, some key lines are collected from standard tooth pictures. Then we use 3DS MAX 9.0 to design the digital tooth model based on these lines. During the design process, it is important to refer to the standard plaster tooth model. After some tests, the standard tooth models designed with this method are accurate and adaptable; furthermore, it is very easy to perform some operations on the models such as deforming and translating. This method provides a new idea to build the database with standard 3D tooth crowns and a basis for dental CAD/CAM system.
Computer-Aided Design
;
Databases, Factual
;
Dental Models
;
Dental Prosthesis Design
;
methods
;
trends
;
Imaging, Three-Dimensional
;
Tooth Crown
;
anatomy & histology
8.Computer aided design and manufacture of the porcelain fused to metal crown.
Xin NIE ; Xiaosheng CHENG ; Ning DAI ; Qing YU ; Guodong HAO ; Quanping SUN
Journal of Biomedical Engineering 2009;26(2):230-238
In order to satisfy the current demand for fast and high-quality prosthodontics, we have carried out a research in the fabrication process of the porcelain fused to metal crown on molar with CAD/CAM technology. Firstly, we get the data of the surface mesh on preparation teeth through a 3D-optical grating measuring system. Then, we reconstruct the 3D-model crown with the computer-aided design software which was developed by ourselves. Finally, with the 3D-model data, we produce a metallic crown on a high-speed CNC carving machine. The result has proved that the metallic crown can match the preparation teeth ideally. The fabrication process is reliable and efficient, and the restoration is precise and steady in quality.
Computer-Aided Design
;
Crowns
;
Dental Porcelain
;
Dental Prosthesis Design
;
Humans
;
Metal Ceramic Alloys
;
Molar
9.Research and application of computer-aided technology in restoration of maxillary defect.
Xiaosheng CHENG ; Wenhe LIAO ; Qingang HU ; Qian WANG ; Ning DAI
Journal of Biomedical Engineering 2008;25(4):762-765
This paper presents a new method of designing restoration model of maxillectomy defect through Computer aided technology. Firstly, 3D maxillectomy triangle mesh model is constructed from Helical CT data. Secondly, the triangle mesh model is transformed into initial computer-aided design (CAD) model of maxillectomy through reverse engineering software. Thirdly, the 3D virtual restoration model of maxillary defect is obtained after designing and adjusting the initial CAD model through CAD software according to the patient's practical condition. Therefore, the 3D virtual restoration can be fitted very well with the broken part of maxilla. The exported design data can be manufactured using rapid prototyping technology and foundry technology. Finally, the result proved that this method is effective and feasible.
Computer-Aided Design
;
Humans
;
Imaging, Three-Dimensional
;
Maxilla
;
diagnostic imaging
;
injuries
;
Maxillofacial Prosthesis
;
Models, Theoretical
;
Prosthesis Design
;
Software
;
Titanium
;
chemistry
;
Tomography, Spiral Computed
10.Virtual orientation of the lower and upper jaws model on the position of centric occlusion.
Xiaosheng CHENG ; Wenhe LIAO ; Xiang ZHANG ; Qing YU
Journal of Biomedical Engineering 2007;24(6):1270-1273
The rotation axis equation of the simple articulator is built by the cylinder feature identification, which facilitates the rotation transform of the lower jaw data. Then the collision points and areas on the position of centric occlusion are found to form two collision couples. The virtual orientation of the lower and upper jaws model is realized by collision detection of the collision couples. Consequently the occlusal relation between the lower and upper jaws is established. It sets a good basis for the virtual adjustment of edentulous occlusal surface. The jaw movement of opening and closing in the state of hinge axis is also simulated accordingly.
Computer Simulation
;
Computer-Aided Design
;
Dental Articulators
;
Dental Models
;
Dental Occlusion, Centric
;
Denture Design
;
methods
;
Humans
;
Jaw
;
physiology

Result Analysis
Print
Save
E-mail