1.Proteomics combined with bioinformatics analysis of protein markers of dry eye
Yanting YANG ; Yajun SHI ; Guang YANG ; Haiyang JI ; Jie LIU ; Jue HONG ; Dan ZHANG ; Xiaopeng MA
International Eye Science 2025;25(1):104-111
AIM:To analyze differential proteins associated with the pathogenesis of dry eye(DE)using bioinformatics methods, in order to reveal their potential molecular mechanisms.METHODS: Articles published in PubMed and EMBASE databases from the inception of the database to August 31, 2023, that used proteomic methods to detect protein expression in clinical samples of dry eye were searched. Differential proteins were selected and further analyzed using the STRING database and Cytoscape software for hub gene screening and module analysis. Protein-protein interaction(PPI)analysis, gene ontology(GO)functional annotation, and Kyoto encyclopedia of genes and genomes(KEGG)pathway enrichment analysis were performed.RESULTS: A total of 21 articles were included, identifying 74 differentially expressed proteins. The most frequently occurring differential proteins were calgranulin A(SA1008), lipocalin-1(LCN1), lysozyme C(LYZ), mammaglobin-B(SCGB2A1), proline-rich protein 4(PRR4), transferrin(TF), and calgranulinB(S100A9). The top 10 hub genes were serum albumin(ALB), tumor necrosis factor(TNF), interleukin 6(IL6), IL1B, IL8, matrix metalloproteinase 9(MMP9), alpha-1-antitrypsin(SERPINA1), IL10, complement component 3(C3), and lactotransferrin(LTF). Module analysis suggested MMP9 and PRR4 as seed genes. KEGG analysis showed that differential proteins were mainly enriched in the IL17 signaling pathway(61.9%).CONCLUSION: The results reveal potential molecular targets and pathways for DE and confirm the association between the pathogenesis of DE and inflammation. Further in-depth research is needed to confirm the significance of these biomarkers in clinical practice.
2.Comparison of short-term safety of two anastomotic techniques when resecting Siewert type II adenocarcinoma of the esophagogastric junction: a multicenter retrospective cohort study
Haikun ZHOU ; Xiaopeng GAO ; Feiyu SHI ; Jingyu WANG ; Qinchuan YANG ; Shisen LI ; Jinqiang LIU ; Panpan JI ; Weidong WANG ; Pengfei YU ; Ruiqi GAO ; Xin GUO ; Gang JI ; Jiangpeng WEI
Chinese Journal of Gastrointestinal Surgery 2024;27(1):47-53
Objective:In this study, we aimed to compare the short-term safety of two digestive tract reconstruction techniques, laparoscopic total abdominal overlap anastomosis and laparoscopic-assisted end-to-side anastomosis, following radical resection of Siewert Type II adenocarcinoma of the esophagogastric junction.Methods:In this retrospective cohort study, we analyzed relevant clinical data of 139 patients who had undergone radical surgery for Siewert Type II esophagogastric junction adenocarcinoma. These included 89 patients treated at the First Affiliated Hospital of Air Force Medical University from November 2021 to July 2023, 36 patients treated at the First Affiliated Hospital of Xi'an Jiaotong University from December 2020 to June 2021, and 14 patients treated at the Yuncheng Central Hospital in Shanxi Province from September 2021 to November 2022. The group consisted of 107 men (77.0%) and 32 women (23.0%) of mean age 62.5±9.3 years. Forty-eight patients underwent laparoscopic total abdominal overlap anastomosis (overlap group), and 91 laparoscopic-assisted end-to-side anastomosis (end-to-side group). Clinical data, surgical information, pathological findings, postoperative recovery, and related complications were compared between the two groups.Results:There were no significant differences in general clinical data between the overlap and end-to-side anastomosis groups (all P>0.05), indicating comparability. There was no significant difference in operation time (267.2±60.1 minutes vs. 262.8±70.6 minutes, t=0.370, P=0.712). However, the intraoperative blood loss in the overlap group (100 [50, 100] mL) was significantly lower compared to the end-to-side group (100[50, 175] mL, Z=2.776, P=0.005). Compared to the end-to-side group, longer distances between the tumor and distal resection margin proximal(1.7±1.0 cm vs. 1.3±0.9 cm, t=2.487, P=0.014) and the tumor and distal resection margin (9.5±2.9 cm vs. 7.9±3.5 cm, t=2.667, P=0.009) were achieved in the overlap group. Compared with the end-to-side group, the overlap group achieved significantly earlier postoperative ambulation (1.0 [1.0, 2.0] days vs. 2.0 [1.0, 3.0] days, Z=3.117, P=0.002), earlier time to first drink (4.7±2.6 days vs. 6.2±3.0 days, t=2.851, P=0.005), and earlier time to first meal (6.0±2.7 days vs. 7.1±3.0 days, t=2.170, P=0.032). However, the hospitalization costs were higher in the overlap group (113, 105.5±37, 766.3) yuan vs. (97, 250.2±27, 746.9) yuan; this difference is significant ( t=2.818, P=0.006). There were no significant differences between the two groups in postoperative hospital stay, total number of lymph nodes cleared, or time to first postoperative flatus (all P>0.05). The incidence of surgery-related complications was 22.9%(11/48) in the overlap group and 19.8% (18/91) in the end-to-side group; this difference is not significant (χ2=0.187, P=0.831). Further comparison of complications using the Clavien-Dindo classification also showed no significant differences ( Z=0.406, P=0.685). Conclusions:Both laparoscopic total abdominal overlap anastomosis and laparoscopic-assisted end-to-side anastomosis are feasible for radical surgery for Siewert Type II esophagogastric junction adenocarcinoma. Laparoscopic total abdominal overlap anastomosis achieves longer proximal and distal resection margins and better postoperative recovery; however, end-to-side anastomosis is more cost-effective.
3.Comparison of short-term safety of two anastomotic techniques when resecting Siewert type II adenocarcinoma of the esophagogastric junction: a multicenter retrospective cohort study
Haikun ZHOU ; Xiaopeng GAO ; Feiyu SHI ; Jingyu WANG ; Qinchuan YANG ; Shisen LI ; Jinqiang LIU ; Panpan JI ; Weidong WANG ; Pengfei YU ; Ruiqi GAO ; Xin GUO ; Gang JI ; Jiangpeng WEI
Chinese Journal of Gastrointestinal Surgery 2024;27(1):47-53
Objective:In this study, we aimed to compare the short-term safety of two digestive tract reconstruction techniques, laparoscopic total abdominal overlap anastomosis and laparoscopic-assisted end-to-side anastomosis, following radical resection of Siewert Type II adenocarcinoma of the esophagogastric junction.Methods:In this retrospective cohort study, we analyzed relevant clinical data of 139 patients who had undergone radical surgery for Siewert Type II esophagogastric junction adenocarcinoma. These included 89 patients treated at the First Affiliated Hospital of Air Force Medical University from November 2021 to July 2023, 36 patients treated at the First Affiliated Hospital of Xi'an Jiaotong University from December 2020 to June 2021, and 14 patients treated at the Yuncheng Central Hospital in Shanxi Province from September 2021 to November 2022. The group consisted of 107 men (77.0%) and 32 women (23.0%) of mean age 62.5±9.3 years. Forty-eight patients underwent laparoscopic total abdominal overlap anastomosis (overlap group), and 91 laparoscopic-assisted end-to-side anastomosis (end-to-side group). Clinical data, surgical information, pathological findings, postoperative recovery, and related complications were compared between the two groups.Results:There were no significant differences in general clinical data between the overlap and end-to-side anastomosis groups (all P>0.05), indicating comparability. There was no significant difference in operation time (267.2±60.1 minutes vs. 262.8±70.6 minutes, t=0.370, P=0.712). However, the intraoperative blood loss in the overlap group (100 [50, 100] mL) was significantly lower compared to the end-to-side group (100[50, 175] mL, Z=2.776, P=0.005). Compared to the end-to-side group, longer distances between the tumor and distal resection margin proximal(1.7±1.0 cm vs. 1.3±0.9 cm, t=2.487, P=0.014) and the tumor and distal resection margin (9.5±2.9 cm vs. 7.9±3.5 cm, t=2.667, P=0.009) were achieved in the overlap group. Compared with the end-to-side group, the overlap group achieved significantly earlier postoperative ambulation (1.0 [1.0, 2.0] days vs. 2.0 [1.0, 3.0] days, Z=3.117, P=0.002), earlier time to first drink (4.7±2.6 days vs. 6.2±3.0 days, t=2.851, P=0.005), and earlier time to first meal (6.0±2.7 days vs. 7.1±3.0 days, t=2.170, P=0.032). However, the hospitalization costs were higher in the overlap group (113, 105.5±37, 766.3) yuan vs. (97, 250.2±27, 746.9) yuan; this difference is significant ( t=2.818, P=0.006). There were no significant differences between the two groups in postoperative hospital stay, total number of lymph nodes cleared, or time to first postoperative flatus (all P>0.05). The incidence of surgery-related complications was 22.9%(11/48) in the overlap group and 19.8% (18/91) in the end-to-side group; this difference is not significant (χ2=0.187, P=0.831). Further comparison of complications using the Clavien-Dindo classification also showed no significant differences ( Z=0.406, P=0.685). Conclusions:Both laparoscopic total abdominal overlap anastomosis and laparoscopic-assisted end-to-side anastomosis are feasible for radical surgery for Siewert Type II esophagogastric junction adenocarcinoma. Laparoscopic total abdominal overlap anastomosis achieves longer proximal and distal resection margins and better postoperative recovery; however, end-to-side anastomosis is more cost-effective.
4.Reference and Enlightenment on the Supervision of Human Genetic Resources from Foreign Legislation
Wenting AN ; Shuo GU ; Miao CHENG ; Jin ZHENG ; Xiaowei ZHANG ; Xiaopeng JI ; Tao XUE
Chinese Medical Ethics 2023;36(7):777-786
As an important biological resource of a country or region, human genetic resources (HGR) are increasingly attracting attention and concern from many countries internationally, and even have been elevated to the dimension of national sovereignty by many countries. As a large country with rich and diverse HGR, relevant regulatory work in China started relatively late compared to foreign countries, but has developed rapidly. However, looking around the world, there is still room for further improvement and development of domestic HGR regulation. By reviewing the regulatory legislation of HGR in some countries abroad, this paper sorted out their advanced experience and highlighted measures in detail, and summarized their deep-seated legislative guidance. A detailed analysis and evaluation were conducted from seven aspects:the advanced level of HGR legislation and the enhancement of legal effectiveness, the systematization and systematization of policies and regulations, the unification of platforms and relevant standards, the highlight of the concept of ethics and the rule of law, the strengthening of anti-discrimination protection, the special protection of major human genetic family resources and national special protection areas of HGR, and the establishment of principled consensus or agreement on HGR in international and local regions, to provide reference for the construction of regulatory policies and legal systems for HGR in China.
5.Posterior vertebral column resection combined with polymethylmethacrylate-augmented pedicle screw instrumentation and shortening of spinal column for stage Ⅲ Kümmell's disease with very severe collapse of fractured vertebra
Xubin JI ; Feng LI ; Zhaowan XU ; Naiwang CHEN ; Dayong LIU ; Yang ZHANG ; Qinmin WU ; Wanping ZHU ; Xiaopeng LI ; Long LI
Chinese Journal of Orthopaedic Trauma 2023;25(7):601-609
Objective:To investigate the feasibility and clinical efficacy of posterior vertebral column resection (PVCR) combined with polymethylmethacrylate-augmented pedicle screw instrumentation and shortening of spinal column for stage Ⅲ Kümmell's disease with very severe collapse of fractured vertebra.Methods:From January 2017 to September 2021, 9 patients with stage Ⅲ Kümmell's disease with very severe collapse of fractured vertebra underwent PVCR combined with polymethylmethacrylate-augmented pedicle screw instrumentation and shortening of spinal column. Their medical records were retrospectively analyzed. There were 1 male and 8 females, aged (66.9±5.8) years. The injured vertebra was located at T 11 in 2 patients, at T 12 in 4, at L 1 in 2 and at L 2 in 1. X-ray, CT and MRI were performed before operation. The posterior intervertebral heights of adjacent vertebral bodies of the fractured vertebra in the median sagittal position were measured on CT or MRI to evaluate the shortening of the spinal column before PVCR. Recorded were intraoperative bleeding volume, operation time, complications, bone graft fusion, and American Spinal Injury Association (ASIA) grading at preoperation and the last follow-up. The visual analogue scale (VAS) pain scores, Oswestry disability index (ODI) scores, and kyphotic cobb angles at preoperation, 1 week and 3 months postoperation, and the last follow-up were compared to evaluate the clinical efficacy of PVCR. Results:All patients underwent surgery successfully, with tight closure of adjacent vertebrae after resection of the injured vertebra and bone grafting. Operation time was (240.6±23.2) min and intraoperative bleeding (505.6±95.0) mL. The 9 patients were followed up for (17.3±5.6) months. No worsening symptoms of nerve injury, cerebrospinal fluid leakage, or other serious complications were found after operation, nor such complications as loosening or breakage of internal fixation or adjacent vertebral fractures. Bone fusion was achieved at the bone graft sites in all patients by the last follow-up. The VAS and ODI scores and cobb angles at 1 week and 3 months postoperation and at the last follow-up were significantly decreased compared with preoperation ( P<0.05). There were no significant differences in VAS scores or cobb angles among postoperative 1 week and 3 months and the last follow-up ( P>0.05), but pairwise comparisons between different time points after operation showed significant differences in ODI, with postoperative 1 week > postoperative 3 months > the last follow-up ( P<0.05). The ASIA grading at the last follow-up was improved from preoperative grade C to grade D in 2 cases, from preoperative grade C to grade E in 1 case and from preoperative grade D to grade E in 5 cases. Conclusion:PVCR combined with polymethylmethacrylate-augmented pedicle screw instrumentation and shortening of spinal column is a feasible and effective surgical treatment for stage Ⅲ Kümmell's disease with very severe collapse of fractured vertebra, leading to good clinical efficacy.
6.Experimental study of magnetic compression technique for anastomosis reconstruction of esophagus
Miaomiao ZHANG ; Lin JI ; Peinan LIU ; Hanzhi ZHANG ; Xingyi MOU ; Shuqin XU ; Yong ZHANG ; Yi LV ; Xiaopeng YAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2022;29(01):95-99
Objective To investigate the feasibility of magnamosis rings designed based on magnetic compression technique in esophageal anastomosis reconstruction. Methods According to the anatomical characteristics of esophagus in SD rats, the esophageal magnamosis rings were designed. SD rats were used as animal models (n=10, 5 males and 5 females) to complete the magnetic anastomosis reconstruction of the cervical esophagus using magnamosis rings, and the operation time, animal survival, postoperative complications, magnetic rings excretion time were recorded. Two weeks after operation, the rats were killed, and the esophageal anastomotic specimens were obtained. The blasting pressure of the anastomotic site was measured and the formation of the anastomotic site was observed with naked eyes. Results Esophageal magnamosis was successfully performed in 10 SD rats, and the median operation time was 11 (8-13) min. All rats survived without anastomotic leakage, anastomotic stenosis, or magnetic rings incarceration. The magnetic rings were discharged after 8 (5-10) days and the burst pressure was higher than 300 mm Hg. Visual observation showed that the anastomotic muscle healed well and the mucosa was smooth. Conclusion The magnetic compression technique can be used for anastomosis reconstruction of esophagus, which has the advantages of simple operation and reliable anastomosis effect, and has clinical application prospect.
7.Design of Magnamosis System for Endoscopic Tissue Clamping.
Miaomiao ZHANG ; Lin JI ; Ting LAN ; Peinan LIU ; Hanzhi ZHANG ; Xingyi MOU ; Aihua SHI ; Feng MA ; Yi LYU ; Xiaopeng YAN
Chinese Journal of Medical Instrumentation 2021;45(6):612-615
Based on the principle of magnetic anastomosis technique, the design of magnetic anastomosis system for endoscopic tissue clamping is proposed. The system includes a semi-ring magnet, a special structure transparent cap and a detachable push rod. With the help of the existing digestive endoscopy and endoscopic tissue gripper, the endoscopic close clamping and anastomosis of the bleeding or perforated tissue can be completed. After the anastomosis, the magnet falls off and is discharged through the digestive tract. Animal experiments showed that the system was easy to use, the fistula was clamped firmly, the magnet was discharged for 7~21 days, and there was no magnet retention and digestive tract obstruction. Further safety verification, optimization of endoscopic operation, the system can be used in clinical trial.
Anastomosis, Surgical
;
Animals
;
Constriction
;
Endoscopy, Gastrointestinal
;
Magnetics
;
Magnets
8. Research Progress of Red Blood Cell Distribution Width in Assessing Severity of Acute Pancreatitis
Xian TU ; Qi JI ; Xi HUANG ; Qingming WU ; Xian TU ; Qi JI ; Xi HUANG ; Yi CHENG ; Xiaopeng CHEN ; Man TU ; Qingming WU
Chinese Journal of Gastroenterology 2021;26(1):53-56
More and more studies have found that red blood cell distribution width (RDW) can be used for acute pancreatitis (AP) classification, dynamic monitoring and evaluation of disease severity, mortality, prognosis and complication. Some inflammatory markers, such as procalcitonin (PCT), C-reactive protein (CRP), neutrophil-to-lymphocyte ratio (NLR) and pancreatitis scoring system are also associated with severity of AP, and can further improve the evaluation of AP severity when combined with RDW. This article reviewed the RDW and classification of AP, the dynamic changes of RDW and AP, RDW combined with inflammatory indices for prediction of severity of AP, and RDW combined with pancreatitis scoring system for prediction of severity of AP, so as to improve the understanding of predictive value of RDW in assessing the severity of AP.
9.Accuracy and clinical application of a REF-XT01 uric acid meter
Maichao LI ; Yuwei HE ; Hailong LI ; Jie LU ; Jie ZHANG ; Xuefeng WANG ; Wei REN ; Can WANG ; Lei PANG ; Ming WANG ; Changgui LI ; Xiaopeng JI
Chinese Journal of Endocrinology and Metabolism 2020;36(11):932-937
Objective:This study aimed to evaluate the accuracy of a portable REF-XT01 uric acid meter in measuring blood uric acid concentration, and to determine whether the results of the uric acid meter could be used to guide the adjustment of uric acid-lowering drugs.Methods:1 551 subjects were enrolled from the Gout Clinical Medical Center of the Affiliated Hospital of Qingdao University. The fasting venous blood was collected and the serum uric acid was measured by an automatic biochemical analyzer. Meanwhile, the capillary blood uric acid was measured by fingertip puncture using the REF-XT01 uric acid meter. Linear regression, intra-group correlation coefficient(ICC), and Bland-Altman plots were used to analyze the uric acid concentration correlation between the biochemical analyzer(sUA BA)and the uric acid meter(sUA UM). The receiver operating characteristic curve(ROC curve)was conducted to evaluate whether sUA UM can be used as a reference for the gout patients to take uric acid-lowering drugs. Results:The regression analysis showed correlation between sUA BA and sUA UM, with the regression formula Y=0.875X+ 39.525( r=0.84, P<0.01)and the ICC was 0.829(95% CI 0.814-0.844, P<0.01). The Bland-Altman diagram showed a good consistence(the absolute deviation was-143.4-114.5 μmol/L, mean deviation was -14.4 μmol/L)between sUA BA and sUA UM. The sensitivity was 96.61%, specificity was 48.81%, and the area under the ROC curve(AUC)was 0.926( P<0.01)when 300 μmol/L was defined as the detection threshold of the uric acid meter, the sensitivity was 90.98%, specificity was 66.78%, and the area under the ROC curve(AUC)was 0.914( P<0.01)when 360 μmol/L was defined as the detection threshold of the uric acid meter. Conclusion:REF-XT01 uric acid meter is applicable for the adjustment of uric acid-lowering drugs for the gout patients, because of its high accuracy for the detection of uric acid.
10.Establishment of gastrointestinal anastomosis by magnetic compression technique in rabbits
Yi LIN ; Lin JI ; Qian FAN ; Senlin ZHU ; Xingyi MOU ; Yuwei WU ; Yixing LI ; Bo DENG ; Yong ZHANG ; Feng MA ; Yi LYU ; Xiaopeng YAN
Chinese Journal of Digestive Endoscopy 2020;37(9):652-656
Objective:To study the feasibility of establishing gastrointestinal anastomosis by magnetic compression technique in rabbits.Methods:Ten healthy New Zealand rabbits were selected as models for gastrointestinal anastomosis by magnetic compression technique. Daughter and parent magnets suitable for gastrointestinal anastomosis in rabbits were designed and manufactured. A daughter magnet was inserted into the stomach through the purse fistula in the lack of blood vessel area of gastric body, and was pushed into the duodenum along the intestinal tract. And then a parent magnet was inserted through the stomach fistula. The daughter and parent magnets were automatically attracted and pressed the gastric and intestinal walls after they were adjusted in the proper position. The stomach fistula was closed with purse string suture. After ischemia, necrosis, detachment of the tissues between magnets, gastrointestinal anastomosis was established, and the magnets and necrotic tissues were expelled together from the body through the digestive tract. Survival of experimental animals was observed. Anastomotic specimens were obtained one month after operation. The blasting pressure of anastomotic stoma was measured, and the healing of anastomotic stoma was observed with naked eyes.Results:According to the pre-designed operative route, 10 New Zealand rabbits all successfully completed the operation and survived one month after surgery. No complications occurred during perioperative period. The operation time was 35.80±4.71 min (range 28.00-43.00 min), and the magnet discharge time was 11.40±1.56 days (range 9.00-14.00 days). Anastomotic specimens were obtained one month after the operation. Gross observation showed that the anastomotic stoma of gastrointestinal bypass anastomosis healed well, and the surrounding tissues adhered slightly. The anastomotic bursting pressure was 103.00±7.95 mmHg (range 94.00-113.00 mmHg) (1 mmHg=0.133 kPa).Conclusion:The establishment of gastrointestinal anastomosis by magnetic compression technique in rabbits is simple and effective.

Result Analysis
Print
Save
E-mail