1.Analysis of mental health status potential categories and related factors among primary and secondary school students in western Yunnan Province
HAN Fang, WANG Qi, WEN Yating, LI Xiaojuan, WEI Hongyu, JIAO Feng
Chinese Journal of School Health 2025;46(7):1009-1013
Objective:
To investigate the mental health status and related factors among primary and secondary school students in western Yunnan Province, so ao to provide scientific evidences for advancing mental health education.
Methods:
In June 2024, a stratified cluster sampling method was employed to select 4 584 students from 18 schools across Diqing Tibetan Autonomous Prefecture, Lincang City and Baoshan City three regions in western Yunnan Province. The Mental Health Test (MHT) was used for assessment. Latent class analysis (LCA) and Logistic regression were applied for data classification and related factor analysis respectively.
Results:
The overall positive detection rate of MHT was 11.81%, with a mean total score of 40.50±19.25. The predominant issues were learning anxiety (58.4%), hypersensitivity tendency (31.1%), and self blame tendency (23.1%). LCA categorized students into four groups:severe psychological problems group (74.4% detection rate), learning anxiety hypersensitivity group ( 16.4 %), learning anxiety physical symptoms group (9.2%), and healthy group (0). Logistic regression revealed that compared with the healthy group, the severe problems group showed higher risks among females ( OR =3.01), junior/senior high school students ( OR =1.88/4.02), and those with authoritarian parenting ( OR =3.54); the anxiety hypersensitivity group had higher risks for females ( OR =1.87), senior high students ( OR =1.54), boarders ( OR =1.31), and authoritarian parenting recipients ( OR = 1.85 ); the anxiety physical symptoms group demonstrated increased risks among females ( OR =2.22), senior high students ( OR =2.58), and authoritarian parenting recipients ( OR =2.74), while lower risks were observed for students with parent/grandparent guardians ( OR =0.38) and non only children ( OR =0.58) (all P <0.05).
Conclusions
Mental health problems are prominent among students in western Yunnan, with gender, grade level, boarding status, guardian type, and parenting style being key determinants. Recommendations include strengthening mental health education, prioritizing left behind children s psychological well being and promoting healthy development.
2.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
3.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
4.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
5.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
6.Dynamic disinfection effect of the upper-room 222 nm ultraviolet radiation on the air in the emergency department in a tertiary general hospital in Beijing, China
Shi CHENG ; Bin XU ; Yue DU ; Jing LI ; Yingxin MA ; Xiaojuan MENG ; Wei HAN ; Xinwei YU ; Aixiang HU ; Yuewei ZHANG
Shanghai Journal of Preventive Medicine 2024;36(9):836-841
ObjectiveTo evaluate the dynamic disinfection effect of the upper-room 222 nm ultraviolet radiation on the air in different areas of the emergency department, and to provide references for a new solution of air disinfection that man-machine coexisted in the medical and healthcare institutions. MethodsThe upper-room 222 nm ultraviolet radiation air sterilizers were installed at a height of 2.3‒2.6 m from the ground in the observation room, computed tomography (CT) scanning room, rescue room and consulting room of the emergency department in Beijing Tiantan Hospital, Capital Medical University . The test area was divided into a 222 nm ultraviolet group and a control group according to whether the 222 nm ultraviolet germicidal air disinfection was conducted or not. The experimental group started air disinfection at8:00 a.m., and the air sampling was conducted from 9:00 a.m. to 16:00 p.m., with a 10 min sampling interval of every 1 hour. While the control group only collected air sample with the same air sampling method used in the experimental group, without air disinfection. The air microbial sampler with six-level sieve impingement was used for the air sampling, and the differences in the total number of airborne bacterial colonies were compared between the two groups. ResultsA total of 128 air samples were collected in the trial, of which 64 were from the experimental group and 64 from the control group. The total number of airborne bacterial colonies in the experimental group was lower than that in the control group (all P<0.001), and was maintained at a lower level throughout the entire period. The killing rate of 222 nm ultraviolet radiation to airborne microorganisms was approximately 55.76% to 76.33% in different sampling areas. The qualified rates of the total number of dynamic airborne bacterial colonies in the observation room, rescue room and consulting room were improved from 12.50%, 37.50% and 25.00% to 81.25%, 100.00% and 100.00%, respectively (all P<0.001). Over 62.50% of the time, the air quality in the consulting room and CT room in the 222 nm ultraviolet group met the environment standards for airborne bacterial colony criteria of class Ⅰ or class Ⅱ. ConclusionThe upper-room222 nm ultraviolet radiation germicidal disinfection can effectively reduce the total number of airborne bacterial colonies and improve the environment for emergency department, and the continuous using of it is helpful for keeping the air safe and clean.
7.Risk factors for cage retropulsion following transforaminal lumbar interbody fusion
Jintao XI ; Qilin LU ; Yang WANG ; Xiaojuan WANG ; Peng LYU ; Long CHEN ; Zhen SHI ; Wei XIE ; Yiliang ZHU ; Xugui LI
Chinese Journal of Tissue Engineering Research 2024;28(9):1394-1398
BACKGROUND:Previous literature reported that the fusion cage moved more than 2 mm from its original position,which means that the fusion cage moved backward.At present,clinical observation has found that the factors leading to the displacement of the fusion cage are complex,and the relationship between these factors and the cage retropulsion is not clear. OBJECTIVE:To explore the risk factors related to cage retropulsion after lumbar interbody fusion. METHODS:Retrospective analysis was conducted in 200 patients who underwent transforaminal lumbar interbody fusion surgery with a polyetheretherketone interbody fusion from February 2020 to February 2022.According to the distance from the posterior edge of the vertebral fusion cage to the posterior edge of the vertebral body after the operation(the second day after the removal of the drainage tube)and 1,3,6 and 12 months after the operation,patients were divided into cage retropulsion group(≥2 mm)and cage non-retropulsion group(<2 mm).The factors that may affect cage retropulsion,such as age,gender,body mass index,bone mineral density,operation time,bleeding,endplate injury,preoperative and postoperative interbody height,cage implantation depth,cage size,and segmental anterior convexity angle,were analyzed by univariate and logistic regression analysis. RESULTS AND CONCLUSION:(1)Posterior displacement of the fusion cage occurred in 15 cases(15/200).The differences in basic information such as age and body mass index between the two groups were not statistically significant.(2)The results of the univariate analysis were that gap height difference,time to wear a brace,segmental anterior convexity angle difference,bone mineral density,and age were related to posterior migration of the cage.(3)The results of logistic regression analysis were that cage size,endplate injury condition,and depth of cage implantation were risk factors for cage retropulsion.(4)These findings suggest that cage retropulsion after lumbar interbody fusion is caused by multiple factors,including segmental anterior convexity angle difference,bone mineral density,cage size,endplate damage,time to wear a brace,and depth of cage implantation.
8.Analysis of the Results of Deafness Gene Screening in 301 Severe and Very Severe Non-syndrome Deafness Children
Xiaojuan HOU ; Li YANG ; Wei DING
Journal of Medical Research 2024;53(1):157-161
Objective To study the results of the deafness gene in 301 children with severe and very severe non-syndrome deafness in Xinjiang,to provide a reference for rehabilitation and genetic counseling after cochlear implantation.Methods A total of 301 patients with severe and very severe non-syndrome deafness who were admitted to the People's Hospital of Xinjiang Uygur Autonomous Region from 2017 to 2019 were collected.After informed consent,the patients were screened for deafness genes,including 25 loci in GJB2,SLC26A4,mt12SrRNA,OTOF,and SLC17A8 genes(c.35delG,c.167delT,c.176_191del16,c.235delC,c.299_300delAT,c.281C>T,c.589G>A,c.IVS7-2A>G,c.1174A>T,c.1226G>A,c.1229C>T,c.IVS15+5G>A,c.1975G>C,c.2027T>A,c.2162C>T,c.2168A>G,c.1494C>T,c.1555A>G,c.1585A>G,c.1047A>G,c.1095T>C,c.960_961 insC/961delT,c.4023G>A,c.4819C>T,c.824C>A),and the detection results were analyzed.Results Among 301 cases of severe and very severe non-syndrome deaf-ness,80 cases of positive mutation were screened,and the total detection rate was 26.58%(80/301).The mutation rates of GJB2,SLC26A4,and mt12SrRNA genes were 10.96%(37/301),12.62%(38/301),and 4.32%(13/301),respectively.The main forms of GJB2 mutations were c.235delC and c.35delG,accounting for 37.50%(30/80)and 8.75%(7/80)of the mutations,respectively.The main forms of SLC26A4 mutations were c.IVS7-2A and c.1174 A>T,accounting for 26.25%(21/80)and 11.25%(9/80)of the mutations,respectively.The main mutation forms of mt12SrRNA were c.960_961 insC/961delT and c.1555A>G,accounting for 7.50%(6/80)and 5.00%(4/80)of the mutations,respectively.The c.4023G>A and c.4819C>T mutations in OTOF and c.824C>A mutations in SLC17A8 were not detected.The total detection rate of mutation sites in the Han nationality was significantly higher than that in the Uygur nationality(x2=19.064,P<0.001).Conclusion GJB2 and SLC26A4 are common pathogenic genes in children with severe and very severe non-syndrome deafness in Xinjiang.There may be other hot spot mutation sites in the Uygur nationality.
9.Association between temperature and mortality: a multi-city time series study in Sichuan Basin, southwest China.
Yizhang XIA ; Chunli SHI ; Yang LI ; Shijuan RUAN ; Xianyan JIANG ; Wei HUANG ; Yu CHEN ; Xufang GAO ; Rong XUE ; Mingjiang LI ; Hongying SUN ; Xiaojuan PENG ; Renqiang XIANG ; Jianyu CHEN ; Li ZHANG
Environmental Health and Preventive Medicine 2024;29():1-1
BACKGROUND:
There are few multi-city studies on the association between temperature and mortality in basin climates. This study was based on the Sichuan Basin in southwest China to assess the association of basin temperature with non-accidental mortality in the population and with the temperature-related mortality burden.
METHODS:
Daily mortality data, meteorological and air pollution data were collected for four cities in the Sichuan Basin of southwest China. We used a two-stage time-series analysis to quantify the association between temperature and non-accidental mortality in each city, and a multivariate meta-analysis was performed to obtain the overall cumulative risk. The attributable fractions (AFs) were calculated to access the mortality burden attributable to non-optimal temperature. Additionally, we performed a stratified analyses by gender, age group, education level, and marital status.
RESULTS:
A total of 751,930 non-accidental deaths were collected in our study. Overall, 10.16% of non-accidental deaths could be attributed to non-optimal temperatures. A majority of temperature-related non-accidental deaths were caused by low temperature, accounting for 9.10% (95% eCI: 5.50%, 12.19%), and heat effects accounted for only 1.06% (95% eCI: 0.76%, 1.33%). The mortality burden attributable to non-optimal temperatures was higher among those under 65 years old, females, those with a low education level, and those with an alternative marriage status.
CONCLUSIONS
Our study suggested that a significant association between non-optimal temperature and non-accidental mortality. Those under 65 years old, females, and those with a low educational level or alternative marriage status had the highest attributable burden.
Female
;
Humans
;
China/epidemiology*
;
Cities
;
Cold Temperature
;
Hot Temperature
;
Mortality
;
Temperature
;
Time Factors
;
Middle Aged
;
Male
10.Advances in the Adjunctive Treatment of Lennox-Gastaut Syndrome with Clobazam and Cannabidiol
Jingtian SHI ; Chaoyang CHEN ; Ting YANG ; Ran WEI ; Xuanling ZHANG ; Zining WANG ; Xiaojuan HU ; Ying ZHOU
JOURNAL OF RARE DISEASES 2024;3(2):252-259
Lennox-Gastaut syndrome(LGS)is a severe,epileptic encephalopathy.In recent years,a variety of drugs have been approved for the treatment of LGS.The U.S.Food and Drug Administration ap-proved clobazam and cannabidiol as adjunctive therapy for LGS in October 2011 and June 2018,respectively.This article provides an overview of clobazam and cannabidiol,including their chemical structures,pharmaco-logical actions,curative effects,safety profile,drug interactions,to introduce the current state of research and the achievements of both drugs.


Result Analysis
Print
Save
E-mail