1.Accuracy and feasibility of non-invasive cell-free fetal DNA RhE blood group genotyping
Jinhua YANG ; Daoju REN ; Xiaowei LI ; Jun XIAO ; Jiangzhou YOU ; Chunyue CHEN ; Xiaojuan ZHANG ; Cuiying LI
Chinese Journal of Blood Transfusion 2025;38(3):368-374
[Objective] To explore the accuracy and feasibility of non-invasive prenatal diagnosis of fetal RhE genotype using cell-free fetal DNA (cff-DNA) from maternal peripheral blood. [Methods] A total of 134 pregnant women with single fetuses and RhE-negative blood group were selected from our hospital from November 2023 to August 2024. Free DNA extraction kit was used to extract free DNA from peripheral blood of pregnant women, and the RhE blood group genotype of free DNA was detected by real-time fluorescent quantitative PCR (RT-qPCR). If the qPCR amplification signal of the sample was negative, the methylated RASSF1A gene was amplified, and the positive amplification result was used as a sign of successful extraction of cff-DNA. Serological microcolumn gel method was used to detect the phenotype of RhE blood group in neonatal peripheral blood. [Results] Among the 134 maternal peripheral blood samples, the cff-DNA detection of RhE blood group phenotypes was consistent with the RhE blood group genotyping of neonatal peripheral blood in 133 cases, including 90 cases of Rhee genotype and 43 cases of RhE genotype, with diagnostic concordance rate of 99.3%, sensitivity of 97.7%, specificity of 100%, youden index of 0.977, area under ROC curve of 0.995, the Kappa value of 0.983, positive predictive value of 100%, and negative predictive value of 98.9%. The sample of 1 case failed to be detected. After the amplification of methylated RASSFIA gene, it was confirmed that the reason for the failure was that no cff-DNA was extracted from the sample. The diagnostic concordance rates of the first, second and third trimesters were 93.8% (15/16), 100% (51/51) and 100% (67/67), respectively. Fisher's exact test method was used to calculate the P value, which was P>0.05, indicating that there was no statistical significance in the difference of diagnostic concordance rate among the three pregnancy periods, and there was no difference in the detection concordance rate of this method in different pregnancy periods. [Conclusion] The use of cff-DNA in maternal peripheral blood for the detection of fetal RhE blood group genotype is an accurate and highly feasible non-invasive prenatal diagnostic method, which is helpful for the clinical diagnosis of fetal and neonatal hemolytic disease caused by anti-E antibody.
5.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
6.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
7.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
8.Association between preschoolers physical activity levels and parental sports concept and behavior
Chinese Journal of School Health 2024;45(7):1036-1039
Objective:
To analyze the impact of parental sports concept and behavior on physical activity in preschool children, so as to provide a foundation for future guidance on fostering childrens physical activity within the family context.
Methods:
From November to December 2020, a clustered convenience sampling method was employed to conduct surveys, and a total of 283 children were selectal from one kindergarten each in Beijing, Shenyang, and Xian. Participating children wore ActiGraph GT9X accelerometers continuously for one week to collect data on different intensity levels of physical activity. Physical Activity afterschool Questionnaire for Preschooler (P-PAQ) was utilized to assess parental sports concept and behavior. The gender differences in physical activity level and physical activity compliance rate were analyzed by using ttest, Mann-Whitney U test, and Chisquare test; and the relationship between parental exercise concepts and behaviors and physical activity of preschool children was analyzed using Spearman rank correlation analysis and multiple linear regression analysis.
Results:
Parental sports concept was significantly positively correlated with average daily moderatetovigorous physical activity (MVPA) and total physical activity (TPA) in children (r=0.12-0.16, P<0.05). Parental sports behavior was significantly positively correlated with childrens average daily TPA (r=0.25, P<0.05). Multiple linear regression revealed that parental sports concept was positively correlated with average daily MVPA and TPA in both boys and girls (B=0.65-0.83), while parental sports behavior only was positively correlated with boys average daily MVPA and TPA (B=0.24-0.25)(P<0.05).
Conclusions
Parental sports concept and behavior can impact physical activity levels in preschool children, exhibiting gender differences. Future guidance on physical activity in family upbringing should consider both parental sports concept and behavior, and pay attention to the influence of childrens gender.
9.Quercetin protects THP-1 macrophages against cellular stress response induced by Pseudomonas aeruginosa protease LasB
Yanying REN ; Xinwei LIU ; Rui ZHU ; Xiaojuan YOU ; Dengzhou LI ; Zhiqiang HE ; Chunxia WANG ; Ximing YANG ; Yongwei LI
Chinese Journal of Preventive Medicine 2024;58(3):337-346
Objective:To investigate the protective effect of quercetin against LasB-induced apoptosis, inflammation, and oxidative stress in THP-1 macrophages, providing valuable insights into the use of quercetin as a virulence inhibitor for Pseudomonas aeruginosa infection treatment. Methods:This was an experimental study. The experimental strain was the standard strain. The LasB protein was obtained utilizing protein recombination technology, while the enzyme activity of LasB was assessed through both the Elastin Congo red assay and fluorescently labelled elastin assay. The LasB-induced THP-1 macrophage infection model was established, and quercetin was utilized for intervention. Cell viability was evaluated via CCK-8 assay, while cell morphology was observed under an inverted microscope. Apoptosis detection involved employing both TUNEL and Annexin V/PI staining. The mRNA expression and protein levels of inflammatory cytokines and COX-2 were determined by RT-qPCR and ELISA respectively. Intracellular ROS levels were quantified using the DCFH-DA fluorescent probe. One-way ANOVA was used for statistical analysis, and Tukey test was used for multiple comparisons. Results:The pLasB with a molecular weight of 33 000 and acceptable enzymatic activity (purity>90%), was successfully obtained. THP-1 macrophages treated with pLasB at a concentration of 100 μg/ml presented significantly decreased viability and integrity rate when compared with the normal control group. Additionally, pLasB promoted apoptosis, up-regulated the levels of inflammatory cytokines IL-1α, IL-1β, IL-6, IL-10, IL-12, and TNF-α, increased intracellular ROS fluorescence intensity, and elevated COX-2 mRNA expression level. Furthermore, the viability of THP-1 macrophages was significantly enhanced under quercetin intervention at concentrations of 2.5 μmol/L, 5 μmol/L and 10 μmol/L. The apoptosis rate exhibited a significant reduction from 18.32%±0.17% to 13.17%±0.20%, 11.43%±0.06% and 7.74%±0.04%, respectively ( F=1 679, P<0.05). There was a notable down-regulation of pro-inflammatory cytokines IL-1α, IL-1β, IL-6, IL-12 and TNF-α while the anti-inflammatory cytokine IL-10 showed a significant up-regulation. Both intracellular ROS fluorescence intensity ( F=86.92, P<0.05) and COX-2 level ( F=24.62, P<0.05) demonstrated a substantial decrease. Conclusion:Quercetin demonstrates significant efficacy in inhibiting LasB-induced apoptosis, inflammation, and oxidative stress in THP-1 macrophages, which highlights immense potential as a potent virulence inhibitor of Pseudomonas aeruginosa.
10.Quercetin protects THP-1 macrophages against cellular stress response induced by Pseudomonas aeruginosa protease LasB
Yanying REN ; Xinwei LIU ; Rui ZHU ; Xiaojuan YOU ; Dengzhou LI ; Zhiqiang HE ; Chunxia WANG ; Ximing YANG ; Yongwei LI
Chinese Journal of Preventive Medicine 2024;58(3):337-346
Objective:To investigate the protective effect of quercetin against LasB-induced apoptosis, inflammation, and oxidative stress in THP-1 macrophages, providing valuable insights into the use of quercetin as a virulence inhibitor for Pseudomonas aeruginosa infection treatment. Methods:This was an experimental study. The experimental strain was the standard strain. The LasB protein was obtained utilizing protein recombination technology, while the enzyme activity of LasB was assessed through both the Elastin Congo red assay and fluorescently labelled elastin assay. The LasB-induced THP-1 macrophage infection model was established, and quercetin was utilized for intervention. Cell viability was evaluated via CCK-8 assay, while cell morphology was observed under an inverted microscope. Apoptosis detection involved employing both TUNEL and Annexin V/PI staining. The mRNA expression and protein levels of inflammatory cytokines and COX-2 were determined by RT-qPCR and ELISA respectively. Intracellular ROS levels were quantified using the DCFH-DA fluorescent probe. One-way ANOVA was used for statistical analysis, and Tukey test was used for multiple comparisons. Results:The pLasB with a molecular weight of 33 000 and acceptable enzymatic activity (purity>90%), was successfully obtained. THP-1 macrophages treated with pLasB at a concentration of 100 μg/ml presented significantly decreased viability and integrity rate when compared with the normal control group. Additionally, pLasB promoted apoptosis, up-regulated the levels of inflammatory cytokines IL-1α, IL-1β, IL-6, IL-10, IL-12, and TNF-α, increased intracellular ROS fluorescence intensity, and elevated COX-2 mRNA expression level. Furthermore, the viability of THP-1 macrophages was significantly enhanced under quercetin intervention at concentrations of 2.5 μmol/L, 5 μmol/L and 10 μmol/L. The apoptosis rate exhibited a significant reduction from 18.32%±0.17% to 13.17%±0.20%, 11.43%±0.06% and 7.74%±0.04%, respectively ( F=1 679, P<0.05). There was a notable down-regulation of pro-inflammatory cytokines IL-1α, IL-1β, IL-6, IL-12 and TNF-α while the anti-inflammatory cytokine IL-10 showed a significant up-regulation. Both intracellular ROS fluorescence intensity ( F=86.92, P<0.05) and COX-2 level ( F=24.62, P<0.05) demonstrated a substantial decrease. Conclusion:Quercetin demonstrates significant efficacy in inhibiting LasB-induced apoptosis, inflammation, and oxidative stress in THP-1 macrophages, which highlights immense potential as a potent virulence inhibitor of Pseudomonas aeruginosa.


Result Analysis
Print
Save
E-mail