1.Research progress of Dexamethasone intravitreal implants in the treatment of diabetic macular edema
Xiaoting YUAN ; Jiao HUANG ; Xiaojuan CHENG ; Rong LI ; Lishuai XU
International Eye Science 2025;25(1):82-87
Diabetic macular edema(DME), a serious complication of diabetic retinopathy(DR), is a chronic condition caused by multiple factors. Throughout its progression, inflammatory factors and vascular endothelial growth factor(VEGF)play a critical role. Anti-VEGF drugs have shown significant effectiveness in the treatment of DME; however, some patients may experience persistent DME after injection or require frequent injections. Dexamethasone intravitreal implants(DEX implants)serve as a sustained-release implant characterized by a reasonable release profile and high bioavailability. They offer safe, effective, and prolonged anti-inflammatory effects, aiding in the repair of retinal barrier and reduction of exudation. To further enhance patients' visual quality, exploring the efficacy of DEX implants in combination with existing treatment regimens has great clinical significance. This review primarily discusses the research advancements in DEX implants, focusing on their pharmacological properties, indications for use, and their combination with existing drugs and treatment methods. It also evaluates the advantages and disadvantages of combination therapy or switching to DEX implants compared to current standard treatments, aiming to provide guidance for personalized treatment options for patients with DME.
3.Association between temperature and mortality: a multi-city time series study in Sichuan Basin, southwest China.
Yizhang XIA ; Chunli SHI ; Yang LI ; Shijuan RUAN ; Xianyan JIANG ; Wei HUANG ; Yu CHEN ; Xufang GAO ; Rong XUE ; Mingjiang LI ; Hongying SUN ; Xiaojuan PENG ; Renqiang XIANG ; Jianyu CHEN ; Li ZHANG
Environmental Health and Preventive Medicine 2024;29():1-1
BACKGROUND:
There are few multi-city studies on the association between temperature and mortality in basin climates. This study was based on the Sichuan Basin in southwest China to assess the association of basin temperature with non-accidental mortality in the population and with the temperature-related mortality burden.
METHODS:
Daily mortality data, meteorological and air pollution data were collected for four cities in the Sichuan Basin of southwest China. We used a two-stage time-series analysis to quantify the association between temperature and non-accidental mortality in each city, and a multivariate meta-analysis was performed to obtain the overall cumulative risk. The attributable fractions (AFs) were calculated to access the mortality burden attributable to non-optimal temperature. Additionally, we performed a stratified analyses by gender, age group, education level, and marital status.
RESULTS:
A total of 751,930 non-accidental deaths were collected in our study. Overall, 10.16% of non-accidental deaths could be attributed to non-optimal temperatures. A majority of temperature-related non-accidental deaths were caused by low temperature, accounting for 9.10% (95% eCI: 5.50%, 12.19%), and heat effects accounted for only 1.06% (95% eCI: 0.76%, 1.33%). The mortality burden attributable to non-optimal temperatures was higher among those under 65 years old, females, those with a low education level, and those with an alternative marriage status.
CONCLUSIONS
Our study suggested that a significant association between non-optimal temperature and non-accidental mortality. Those under 65 years old, females, and those with a low educational level or alternative marriage status had the highest attributable burden.
Female
;
Humans
;
China/epidemiology*
;
Cities
;
Cold Temperature
;
Hot Temperature
;
Mortality
;
Temperature
;
Time Factors
;
Middle Aged
;
Male
4.High-throughput screening of novel TFEB agonists in protecting against acetaminophen-induced liver injury in mice.
Xiaojuan CHAO ; Mengwei NIU ; Shaogui WANG ; Xiaowen MA ; Xiao YANG ; Hua SUN ; Xujia HU ; Hua WANG ; Li ZHANG ; Ruili HUANG ; Menghang XIA ; Andrea BALLABIO ; Hartmut JAESCHKE ; Hong-Min NI ; Wen-Xing DING
Acta Pharmaceutica Sinica B 2024;14(1):190-206
Macroautophagy (referred to as autophagy hereafter) is a major intracellular lysosomal degradation pathway that is responsible for the degradation of misfolded/damaged proteins and organelles. Previous studies showed that autophagy protects against acetaminophen (APAP)-induced injury (AILI) via selective removal of damaged mitochondria and APAP protein adducts. The lysosome is a critical organelle sitting at the end stage of autophagy for autophagic degradation via fusion with autophagosomes. In the present study, we showed that transcription factor EB (TFEB), a master transcription factor for lysosomal biogenesis, was impaired by APAP resulting in decreased lysosomal biogenesis in mouse livers. Genetic loss-of and gain-of function of hepatic TFEB exacerbated or protected against AILI, respectively. Mechanistically, overexpression of TFEB increased clearance of APAP protein adducts and mitochondria biogenesis as well as SQSTM1/p62-dependent non-canonical nuclear factor erythroid 2-related factor 2 (NRF2) activation to protect against AILI. We also performed an unbiased cell-based imaging high-throughput chemical screening on TFEB and identified a group of TFEB agonists. Among these agonists, salinomycin, an anticoccidial and antibacterial agent, activated TFEB and protected against AILI in mice. In conclusion, genetic and pharmacological activating TFEB may be a promising approach for protecting against AILI.
5.Cost-effectiveness analysis of chemical treatment with drones for Oncomelania hupensis control in marshland and lake areas
Yong CHEN ; Xiaojuan XU ; Daolong WEN ; Bo DAI ; Lan GAO ; Rong ZHANG ; Qingqing HUANG ; Linlin LI ; Fan ZHA ; Liang FANG ; Ping ZHANG ; Shiqing ZHANG ; Chunli CAO
Chinese Journal of Schistosomiasis Control 2024;36(5):502-506
Objective To evaluate the molluscicidal effect and cost of spraying molluscicides with drones against Oncomelania hupensis snails in marshland and lake areas, so as to provide new insights into field snail control in China. Methods A marshland and lake setting measuring approximately 12 000 m2 was selected in Wanzhi District, Wuhu City on June 2023 as the test field, and assigned to four groups, of 3 000 m2 in each group. Environmental cleaning was not conducted in groups A or B, which were given 5% niclosamide ethanolamine salt granules sprayed with knapsack-type sprayers and drones at a dose of 40 g/m2, and environmental cleaning was conducted in groups C and D, which were given 5% niclosamide ethanolamine salt granules sprayed with drones and knapsack-type sprayers at a dose of 40 g/m2, respectively. O. hupensis snails were surveyed before chemical treatment and 1, 3, 5, 7, 14 days post-treatment. The uniformity of chemicals was determined on the day of treatment, and the snail mortality, corrected snail mortality and density of living snails were calculated and compared among groups. The cost of molluscicides, labor fees of environmental cleaning and chemical treatment and cost of equipment were calculated, and the cost for a 1% reduction in the mean density of living snails was calculated 14 days post-treatment. Results The mean densities of living snails and mortality rates of snails were 1.82 to 2.85 snails/0.1 m2 and 1.41% to 2.94% in groups A, B, C and D before chemical treatment, and the mortality and corrected mortality of snails were 55.75%, 49.32%, 85.94% and 87.50%, and 55.00%, 48.47%, 85.70% and 87.29% in groups A, B, C and D 14 days post-treatment. There was a significant difference in the mortality of snails among the four groups 14 days post-treatment (χ2 = 38.735, P < 0.005), and there was a higher snail mortality in Group D than in Group A (χ2 = 16.876, P < 0.005), and higher in Group C than in Group B (χ2 = 20.508, P < 0.005). The density of living snails reduced by 55.00%, 43.94%, 90.43% and 87.14% 14 days post-treatment relative to pre-treatment in groups A, B, C and D, respectively. The test for uniformity of chemicals showed that the mean dose of molluscicides were 57.34, 55.21, 40.19 g/m2 and 32.37 g/m2 in groups A, B, C and D, respectively, and the minimal standard deviation (7.07) and coefficient of variation (0.18) of mean doses were seen in Group C. The costs for chemical treatment were 0.33 Yuan in groups A and B and 1.53 Yuan in groups C and D, respectively. The costs for a 1% reduction in the mean density of living snails were 17.82, 22.47, 50.73 Yuan and 52.56 Yuan in groups A, B, C, and D 14 days post-treatment, respectively. Conclusions The molluscicidal effect and cost of spraying 5% niclosamide ethanolamine salt granules with drones are comparable to manual spraying, and chemical treatment with drones are high in uniformity of molluscicides, time- and labor-saving, and feasible for applications in complex environments, which deserves widespread applications in the field of snail control.
6.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
7.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
8.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
9.Exploration of the high-quality development path of university-affiliated hospitals facilitated by"seven integrations"under the framework of"one integration and two highs"
Xuan XIE ; Yuping HUANG ; You CHEN ; Xiaojuan JING ; Siqi HUANG
Modern Hospital 2024;24(11):1658-1661,1666
In recent years,challenges persist in the grassroots Party building in the university-affiliated hospitals though increased efforts have been intensified.These challenges include a lack of alignment between Party building and the hospital's central tasks,an absence of distinctive Party building brands,an insufficiently prominent role of Party organizations in hospital development,and inadequate leveraging of the Party construction for promoting medical services and cultivating medical talents.Starting from an exploration of the connotation and significance of constructing framework of"One Integration and Two Highs"in university-affiliated hospitals,this paper conducts an in-depth analysis of the existing problems and their causes within this frame-work.From a holistic perspective,the paper proposes a new path for establishing the"One Integration and Two Highs"frame-work in university-affiliated hospitals,centered around"Seven Integrations":concept integration,organization integration,strength integration,vehicle integration,culture integration,innovation integration,and assessment integration.
10.Value of TRPS1 in diagnosis and differential diagnosis of synovial sarcoma
Yijing LIU ; Xiaojuan WANG ; Zhiwen LI ; Lan CHEN ; Yongfeng ZHANG ; Wenbin HUANG
Chinese Journal of Clinical and Experimental Pathology 2024;40(10):1064-1067,1074
Purpose To study the expression of of mono-clonal and polyclonal TRPS1 antibodies in synovial sarcoma,and to explore the value of TRPS1 in the diagnosis and differen-tial diagnosis of synovial sarcoma and the sensitivity and speci-ficity of polyclonal TRPS1 for the diagnosis of synovial sarcoma.Methods Immunohistochemical EnVision method was used to detect the expression of monoclonal and polyclonal TRPS1 anti-bodies in the synovial sarcomas and its mimickers.Results A-mong 31 cases of synovial sarcoma,the positive rates of poly-clonal and monoclonal TRPS1 antibodies were 54.8%and 93.5%,respectively.Of 30 synovial sarcoma mimicking le-sions,2 were positive for TRPS1(polyclonal antibody),which was 6.67%,and TRPS1 was more frequently expressed in syno-vial sarcoma than in non-synovial sarcoma(P<0.05).The sensitivity of polyclonal TRPS1 antibody for the diagnosis of syn-ovial sarcoma was 93.5%,and the specificity was 93.3%.Conclusion Polyclonal TRPS1 antibody has a higher sensitivity and specificity for the diagnosis of synovial sarcoma and it there-fore is recommended in routine pathologic diagnosis.

Result Analysis
Print
Save
E-mail