1.Association between temperature and mortality: a multi-city time series study in Sichuan Basin, southwest China.
Yizhang XIA ; Chunli SHI ; Yang LI ; Shijuan RUAN ; Xianyan JIANG ; Wei HUANG ; Yu CHEN ; Xufang GAO ; Rong XUE ; Mingjiang LI ; Hongying SUN ; Xiaojuan PENG ; Renqiang XIANG ; Jianyu CHEN ; Li ZHANG
Environmental Health and Preventive Medicine 2024;29():1-1
BACKGROUND:
There are few multi-city studies on the association between temperature and mortality in basin climates. This study was based on the Sichuan Basin in southwest China to assess the association of basin temperature with non-accidental mortality in the population and with the temperature-related mortality burden.
METHODS:
Daily mortality data, meteorological and air pollution data were collected for four cities in the Sichuan Basin of southwest China. We used a two-stage time-series analysis to quantify the association between temperature and non-accidental mortality in each city, and a multivariate meta-analysis was performed to obtain the overall cumulative risk. The attributable fractions (AFs) were calculated to access the mortality burden attributable to non-optimal temperature. Additionally, we performed a stratified analyses by gender, age group, education level, and marital status.
RESULTS:
A total of 751,930 non-accidental deaths were collected in our study. Overall, 10.16% of non-accidental deaths could be attributed to non-optimal temperatures. A majority of temperature-related non-accidental deaths were caused by low temperature, accounting for 9.10% (95% eCI: 5.50%, 12.19%), and heat effects accounted for only 1.06% (95% eCI: 0.76%, 1.33%). The mortality burden attributable to non-optimal temperatures was higher among those under 65 years old, females, those with a low education level, and those with an alternative marriage status.
CONCLUSIONS
Our study suggested that a significant association between non-optimal temperature and non-accidental mortality. Those under 65 years old, females, and those with a low educational level or alternative marriage status had the highest attributable burden.
Female
;
Humans
;
China/epidemiology*
;
Cities
;
Cold Temperature
;
Hot Temperature
;
Mortality
;
Temperature
;
Time Factors
;
Middle Aged
;
Male
2.High-throughput screening of novel TFEB agonists in protecting against acetaminophen-induced liver injury in mice.
Xiaojuan CHAO ; Mengwei NIU ; Shaogui WANG ; Xiaowen MA ; Xiao YANG ; Hua SUN ; Xujia HU ; Hua WANG ; Li ZHANG ; Ruili HUANG ; Menghang XIA ; Andrea BALLABIO ; Hartmut JAESCHKE ; Hong-Min NI ; Wen-Xing DING
Acta Pharmaceutica Sinica B 2024;14(1):190-206
Macroautophagy (referred to as autophagy hereafter) is a major intracellular lysosomal degradation pathway that is responsible for the degradation of misfolded/damaged proteins and organelles. Previous studies showed that autophagy protects against acetaminophen (APAP)-induced injury (AILI) via selective removal of damaged mitochondria and APAP protein adducts. The lysosome is a critical organelle sitting at the end stage of autophagy for autophagic degradation via fusion with autophagosomes. In the present study, we showed that transcription factor EB (TFEB), a master transcription factor for lysosomal biogenesis, was impaired by APAP resulting in decreased lysosomal biogenesis in mouse livers. Genetic loss-of and gain-of function of hepatic TFEB exacerbated or protected against AILI, respectively. Mechanistically, overexpression of TFEB increased clearance of APAP protein adducts and mitochondria biogenesis as well as SQSTM1/p62-dependent non-canonical nuclear factor erythroid 2-related factor 2 (NRF2) activation to protect against AILI. We also performed an unbiased cell-based imaging high-throughput chemical screening on TFEB and identified a group of TFEB agonists. Among these agonists, salinomycin, an anticoccidial and antibacterial agent, activated TFEB and protected against AILI in mice. In conclusion, genetic and pharmacological activating TFEB may be a promising approach for protecting against AILI.
3.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
4.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
5.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
6.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
7.Drug resistance and serological detection of Candida isolated from a fungal surveillance network in Hainan province from 2013 to 2022
WANG Like ; CHEN Xiaojuan ; ZHANG You ; CHEN Lin ; LIN Chong ; PEI Hua
China Tropical Medicine 2024;24(2):136-
Objective To collect data of fungi isolated from a fungus monitoring network in Hainan Province from 2013 to 2022, and analyze the drug resistance characteristics of Candida and the results of serological tests, with an aim to provide a basis for clinical diagnosis and treatment. Methods In accordance with the National Fungal Drug Resistance Monitoring Network technical scheme, the qualifying fungal data were extracted from the microbial identification system database using SQL language, and the data information was then analyzed, with statistical processing done using SPSS 26.0 software. Results Among 5 503 fungal isolates from clinical specimens between 2013 and 2022, cervical orifice secretions accounted for 30.37%(1 671 strains), mid-stream urine for 23.55%(1 296 strains), lower respiratory tract specimens for 25.24% (1 389 strains)[(sputum for 20.37%(1 121 strains) and alveolar lavage fluid for 4.87%(268 strains)], wound pus for 9.59%(528 strains), ascites for 5.60%(308 strains), blood for 3.67%(202 strains), cerebrospinal fluid for 0.38%(21 strains), and joint fluid for 0.04%(2 strains), with the highest number of strains isolated in 2022 and the lowest in 2013, the 2022 figure is about 2.6 times that of 2013. Among yeast-like fungi, Candida albicans had the highest proportion with 3 312 strains accounting for 60.2%; The highest resistance rate of Candida albicans was to fluconazole at 16.7%, with 2.5% being non-wild type (NWT) for amphotericin B; Candida tropicalis had the highest rate of resistance to fluconazole at 36.0%, with NWT at 41.1% for fluconazole and 3.1% for amphotericin B; Candida glabrata had a resistance rate to fluconazole of 2.8%, dose-dependent susceptibility (SDD) of 97.2%, NWT of 15.5% for fluconazole, and NWT of 8.6% for itraconazole; Candida parapsilosis had the highest resistance rate to fluconazole at 15.7% and and NWT of 8.3% for amphotericin B; Candida krusei had a 0.0% resistance rate to caspofungin; and Candida dubliniensis was 100.0% NWT to fluconazole. Of 70 cases of blood culture-positive specimens, 64 cases were detected by G test and 25 cases by Mn test, and the positive blood cultures were statistically significant when compared with the G test and Mn test, respectively (P<0.01). Conclusions Fungal serological test can make up for the deficiency of blood culture and distinguish fungal invasion and colonization, thus providing a basis for the effective control of fungal infection in clinical practice.
8.Evaluation of rational use of intravenous iron in patients with iron deficient anemia and abnormal uterine bleeding in gynaecology
Jing XU ; Hua ZHANG ; Fan LI ; Mingwei LI ; Xiaojuan WANG
China Pharmacist 2024;27(2):272-278
Objective To investigate the application of intravenous iron in patients with abnormal uterine bleeding(AUD)and iron deficiency anemia(IDA)in gynecology,to establish the drug utilization evaluation(DUE)standard,and to comprehensively evaluate the rationality of the clinical application of intravenous iron by analytic hierarchy process(AHP),so as to provide reference for the rational use of intravenous iron in clinical practice.Methods The medical records of patients with AUD and IDA from January to December 2022 in the First Affiliated Hospital of Anhui University of Science and Technology were collected,and the special rationality of the drug was evaluated from the aspects of indications,route and frequency of administration,daily dosage,solvent,combination medication,and contraindications of iron sucrose injection,and the DUE standard of the drug was formulated.AHP was used to analyze and evaluate 113 archived cases of intravenous iron in gynecology from January to December 2022.Results A total of 113 patients were treated with iron sucrose injection,and the indications,route of administration,solvent,contraindications,and allergic reactions were reasonable.The main unreasonableness was that the frequency of administration was inappropriate,the daily dose was inappropriate,the combination was not appropriate,the total iron supplement was not up to standard,and there was no continuous drug monitoring after medication.The case scores 90~100,70~<90 and 60~<70 were 6(5.31%),106(93.81%)and 1(0.88%),respectively.Conclusion Patients with AUD and IDA should pay attention to the dosage,total amount of iron supplementation,combined application of drugs and continuous medication monitoring after intravenous iron supplementation,so as to improve the rationality of their use.
9.Application of PCNE classification system in pharmaceutical monitoring of patients with respiratory diseases
Man KANG ; Xian ZHANG ; Mingwei LI ; Hua ZHANG ; Jing XU ; Xiaojuan WANG
China Pharmacist 2024;27(2):336-344
Objective To provide pharmaceutical monitoring using the Pharmaceutical Care Network Europe(PCNE)for patients with respiratory diseases,to explore effective pharmaceutical monitoring models in the department of respiratory,and to promote clinical rational drug use.Methods Inpatients diagnosed with chronic obstructive pulmonary disease(COPD)and lung infections in 2022 at the First Affiliated Hospital of Anhui University of Science and Technology were selected and divided into a simple group and an intervention group.According to the PCNE classification system,the types,causes,interventions,acceptance of interventions,and resolution status of drug-related problems(DRPs)were analyzed.Results A total of 120 cases were included,60 cases in the simple group and 60 cases in the intervention group.Regarding the number of DRPs,there were 15 cases in the simple group and 45 cases in the intervention group,and there was a significant difference between the two groups(P<0.05).There were a total of 82 DRPs,which were mainly related to therapeutic efficacy(51.22%)and safety(46.34%),and the reasons for this were that patients'incorrect medication usage method,inappropriate usage and dosage,and unscheduled safety monitoring,etc.The pharmacist interventions were 75(91.46%)at the drug level,38(46.34%)at the physician level,and 43(52.44%)at the patient level;after the pharmacist interventions,the acceptance rate was in the range of 97.56%,and 74.39%of the DRPs were resolved.Conclusion PCNE classification system helps clinical pharmacists to enhance their ability to find and deal with DRPs,reduce the risk of clinical adverse events and promote reasonable and safe drug use.Meanwhile,it is conducive to the standardization of pharmaceutical care records for patients with respiratory diseases and provides reference for pharmaceutical service models for patients in the department of respiratory.
10.A Prospective Cohort Study on the Risk of Major Adverse Cardiovascular Events in Patients with Coronary Heart Disease after Percutaneous Coronary Intervention with Blood-invigorating and Stasis-dissolving Medicinals
Lintong YU ; Shiyi TAO ; Xiaojuan MA ; Jie GAO ; Hua QYU ; Yu YANG ; Bingchang CHEN ; Dazhuo SHI
Journal of Traditional Chinese Medicine 2024;65(18):1895-1902
ObjectiveTo explore the impact of blood-invigorating and stasis-dissolving medicinals combined with conventional western medicine on the major adverse cardiovascular events (MACE) in patients with coronary heart disease (CHD) after percutaneous coronary intervention (PCI). MethodsA prospective cohort study was conducted to collect data on consecutive cases of CHD after PCI. According to whether blood-invigorating and stasis-dissolving medicinals were used, the cases were divided into a Chinese herbal medicinals (CHM) group and control group. The primary outcome was the incidence of MACE one year after PCI, while the secondary outcomes included TCM syndrome score and echocardiography left ventricular ejection fraction (LVEF). Logistic regression analysis was performed to explore the influencing factors of MACE. ResultsA total of 844 patients who met the criteria were included, with 617 in the CHM group and 227 in the control group. The main blood-invigorating and stasis-dissolving medicinals being used were Danshen (Radix et Rhizoma Salviae Miltiorrhizae, 46.35%), Chuanxiong (Rhizoma Chuanxiong, 45.87%), and Chishao (Radix Paeoniae Rubra, 42.30%). After a median follow-up of 12.73 months, the incidence of MACE in the CHM group (142/617, 23.01%) was significantly lower than that in the control group (68/227, 29.96%) with significant difference (OR=0.70, 95%CI 0.50 to 0.98, P = 0.04). The LVEF of the CHM group [(60.06±6.13)%] was higher than that of the control group [(58.27±7.36)%] with significant difference (t = 0.356, P<0.01). The TCM syndrome score in the CHM group decreased to 12.66±4.47, while that in the control group increased to 13.81±3.88, with the results favoring the CHM group (t = 2.78, P<0.01). Univariate analysis showed correlations between the incidence of MACE after PCI and the use of blood-invigorating and stasis-dissolving medicinals, LVEF, usage of renin-angiotensin-aldosterone system (RAAS) inhibitors, TCM syndrome score, and usage of β blockers (P<0.05). Multivariate analysis showed that the use of blood-invigorating and stasis-dissolving medicinals was significantly associated with the reduction of MACE (P<0.01), while the baseline LVEF decline, TCM syndrome score increase, no use of RAAS inhibitors or β blockers were the risk factors of MACE after PCI (P<0.05). ConclusionThe use of blood-invigorating and stasis-dissolving medicinals based on the conventional western medicine can reduce the risk of MACE one year after PCI of CHD, improve the TCM syndromes and protect heart function.

Result Analysis
Print
Save
E-mail