1.Establishment and evaluation of anterior cervical discectomy fusion model in small-tailed Han sheep model
Xinyu DOU ; Yu LIU ; Xiao LIU ; Bin ZHU ; Fei JIA ; Linbang WANG ; Gong JIN ; Fei SHEN ; Xiaoguang LIU
Acta Laboratorium Animalis Scientia Sinica 2024;32(2):139-150
Objective Cervical disc herniation(CDH)is one of the common orthopaedic diseases.With the in-depth study of it and the development of cervical implants,the establishment of cervical fusion animal models has become an indispensable part.Notably however,studies of the establishment and evaluation of cervical fusion animal models in China are currently lacking.This study aimed to provide a suitable animal model and evaluation scheme for implants for cervical spine-related research.Methods Small-tailed Han sheep were chosen for anterior cervical discectomy fusion(ACDF)after modified surgery,and a polyetheretherketone(PEEK)interbody fusion cage(Cage)(control group),3D-printed Ti6Al4V Cage(group 1),and new method Ti6Al4V Cage(group 2)were implanted in different cervical segments(C2/3~C4/5)in each sheep,respectively.Hematology and histopathological analyses were carried out after surgery to evaluate recovery of sheep and the biosafety of the materials.Bone in-growth and bone fusion were assessed by X-ray,computed tomography(CT),Micro-CT and quantitative analysis,hard tissue section staining,and biomechanical tests.Results The modified ACDF ovine model was established successfully.There were no significant differences in important hematology indexes(P>0.05)and histopathological analysis showed no pathological changes,such as inflammatory cell infiltration.The implants had good biosafety.Furthermore,X-ray and CT examinations showed that the position of internal fixation and the interbody fusion were good.Micro-CT and quantitative analysis at 3 and 6 months after operation showed that compared with PEEK Cage group,the bone volume/total volume and trabecular number were significantly increased(P<0.01)while the trabecular spacing was significantly decreased in the new method Ti6Al4V and 3D-printed Ti6Al4V groups compared with the PEEK Cage group(P<0.01).Moreover,the new method new method Ti6Al4V Cage group had more bone growth(P<0.01).Hard tissue section staining demonstrated that the pores of the new method Ti6Al4V Cage and 3D-printed Ti6Al4V Cage had obvious bone growth and relatively dense pores in the new method Ti6Al4V and 3D-printed Ti6Al4V groups,and the combination was slightly better than that of PEEK Cage.Biomechanical evaluation indicated that the new method Ti6Al4V Cage and 3D-printed Ti6Al4V Cage reduced the range of cervical flexion-extension,lateral bending,and axial rotation(P<0.05)compared with the PEEK cage,as well as enhancing the stability of the cervical vertebra,and the new method Ti6Al4 V Cage was more advantageous(P<0.05).Conclusions After the establishment of the modified ACDF ovine model,reasonable and effective assessment method were used to demonstrate the suitability and effectiveness of the model and the good biosecurity of all three Cage materials.Compared with the PEEK Cage,the new method Ti6Al4V Cage and 3D-printed Ti6Al4V Cages showed better performances in terms of bone growth and bone fusion,which could enhance the stability of the cervical vertebrae.The new method Ti6Al4V Cage was particularly advantageous.
2.Application of rapid daily quality assurance for pencil beam scanning proton therapy system
Renchao ZHENG ; Xiaoguang LU ; Weiqing WU ; Zhiping XIAO ; Fei LIU ; Guangyuan HU ; Xianglin YUAN
Chinese Journal of Medical Physics 2024;41(10):1206-1210
Objective To analyze the daily quality assurance(QA)measurement results of IBA Sphinx Compact device on the Mevion compact pencil beam scanning proton therapy system for evaluating its clinical application value in proton therapy.Methods The daily QA measurement of Mevion S250i proton therapy system was carried out with Sphinx Compact device for 30 consecutive days,and the measurement results were analyzed.Results The average deviation between the positioning laser and the image center was(0.42±0.27)mm in 30 days.All of the proximal and distal depth errors of the high-and low-energy pencil beams were within 0.50 mm.The position deviation of all the spots measured did not exceed 1.00 mm,and the size deviation was less than 7.5%.The deviation between the image center and the beam center was not more than 0.75 mm.The relative deviation of the flatness of the rectangular field was about 0.5%.The deviation of the output dose of the square field was within 1.0%.Conclusion The proton system daily QA measurement items recommended by AAPM TG-224 report can be accurately and rapidly measured with Sphinx Compact device.The device is a practical and efficient daily QA tool with high practical value in clinic.
3.The calibration of CT modeling for proton therapy treatment planning system
Renchao ZHENG ; Xiaoguang LU ; Weiqing WU ; Zu'an ZHENG ; Zhiping XIAO ; Junchao LI ; Xianglin YUAN
Chinese Journal of Radiation Oncology 2024;33(10):935-941
Objective:To verify and calibrate the CT modeling curves of three CT devices in RayStation proton treatment planning system (TPS).Methods:CT-mass density (CT-MD) curves were established by CT Hounsfield units of different tissue substitute materials obtained by scanning the model with CT equipment. CT-stopping power (CT-SP) curves were established by calculation based on the chemical composition of various human tissues. The equivalent water thickness of tissue substitute modules was calculated with different CT modeling curves in TPS. The actual equivalent water thickness of various modules was measured by a Bragg peak detector, and compared with the calculated values of TPS to verify the accuracy of different CT models.Results:The differences of CT modeling curves were significantly different under different tube voltage scanning protocols. Compared with CT-MD curves, CT-SP curves based on the stoichiometric calibration were more suitable for proton dose calculation. However, the values of stopping power corresponding to high CT values still needed to be optimized, and the calculation error after calibration was less than 3%.Conclusion:The method of verifying and calibrating CT unit curves of proton TPS is described, proving that the CT-SP curves after stoichiometric calculation are more suitable for proton dose calculation.
4.Integrated analysis of gut microbiome and host immune responses in COVID-19.
Xiaoguang XU ; Wei ZHANG ; Mingquan GUO ; Chenlu XIAO ; Ziyu FU ; Shuting YU ; Lu JIANG ; Shengyue WANG ; Yun LING ; Feng LIU ; Yun TAN ; Saijuan CHEN
Frontiers of Medicine 2022;16(2):263-275
Emerging evidence indicates that the gut microbiome contributes to the host immune response to infectious diseases. Here, to explore the role of the gut microbiome in the host immune responses in COVID-19, we conducted shotgun metagenomic sequencing and immune profiling of 14 severe/critical and 24 mild/moderate COVID-19 cases as well as 31 healthy control samples. We found that the diversity of the gut microbiome was reduced in severe/critical COVID-19 cases compared to mild/moderate ones. We identified the abundance of some gut microbes altered post-SARS-CoV-2 infection and related to disease severity, such as Enterococcus faecium, Coprococcus comes, Roseburia intestinalis, Akkermansia muciniphila, Bacteroides cellulosilyticus and Blautia obeum. We further analyzed the correlation between the abundance of gut microbes and host responses, and obtained a correlation map between clinical features of COVID-19 and 16 severity-related gut microbe, including Coprococcus comes that was positively correlated with CD3+/CD4+/CD8+ lymphocyte counts. In addition, an integrative analysis of gut microbiome and the transcriptome of peripheral blood mononuclear cells (PBMCs) showed that genes related to viral transcription and apoptosis were up-regulated in Coprococcus comes low samples. Moreover, a number of metabolic pathways in gut microbes were also found to be differentially enriched in severe/critical or mild/moderate COVID-19 cases, including the superpathways of polyamine biosynthesis II and sulfur oxidation that were suppressed in severe/critical COVID-19. Together, our study highlighted a potential regulatory role of severity related gut microbes in the immune response of host.
COVID-19
;
Clostridiales
;
Gastrointestinal Microbiome
;
Humans
;
Immunity
;
Leukocytes, Mononuclear
;
SARS-CoV-2
5.Baseline characteristics of the Chinese health quantitative CT big data program in 2018—2019
Kaiping ZHAO ; Jian ZHAI ; Limei RAN ; Yongli LI ; Shuang CHEN ; Yan WU ; Guobin HONG ; Yong LU ; Yuqin ZHANG ; Xiao MA ; Jing LU ; Xigang XIAO ; Xiangyang GONG ; Zehong YANG ; Wei CHEN ; Lü YINGRU ; Jianbo GAO ; Shaolin LI ; Yuehua LI ; Xiaojuan ZHA ; Zhiping GUO ; Qiang ZENG ; Zhenlin LI ; Jing WU ; Xiaoguang CHENG
Chinese Journal of Health Management 2022;16(9):596-603
Objective:To describe the baseline characteristics of the subjects enrolled in the China Quantitative CT (QCT) big data program in 2018—2019.Methods:Based on baseline data from the Chinese health big data project from January 2018 to December 2019 from the eligible enrolled population, measurements of bone mineral density (BMD) and visceral adipose tissue (VAT) were performed using Mindways′ QCT Pro Model 4 system. The baseline data of age, gender, regional distribution, height, weight, abdominal circumference, blood pressure, blood routine and blood biochemical tests were analyzed. And the single factor analysis of variance (ANOVA) was used to check the age related trend of BMD and VAT in both genders.Results:After screening the inclusion exclusion criteria and outliers of the main indicators, 86 113 people were enrolled in the project. The enrollment rate was 92.47%, including 35 431 (41.1%) women and 50 682 (58.9%) men, and the ratio of men to women was 1.43. The mean age was (50.3±12.7) years in all the subjects, and it was (50.2±12.8) years and (50.4±12.5) years in men and women, respectively, and there was no statistical difference between the two genders ( P>0.05). Total of 43 833 people were enrolled in east China, it was the largest group by region (50.90%), it was followed by central China (16 434 people, 19.08%), and the number of people enrolled in Northeast China was the lowest (2 914 people, 3.38%). The rate of completing of health information indicators related to the main outcome of the study were all above 70%, and there were significant differences between men and women (all P<0.05). The mean BMD was (139.33±46.76) mg/cm 3 in women, (135.90±36.48) mg/cm 3 in men, which showed a decreasing trend with age in both gender (both P<0.001); the mean intra-abdominal fat area was (116.39±56.23) cm 2 in women, (191.67±77.07) cm 2 in men, and there was an increasing trend with age in both men and women (both P<0.001). Conclusions:There are gender differences in BMD and VAT measured by QCT with different age tendency, and there are gender differences in health information index. Regional factors should also be taken into account for regional differences in the inclusion of data.
6.Normal reference and regional variation of spinal bone mineral density under the quantitative CT in Chinese male population
Liuping CHEN ; Jian ZHAI ; Limei RAN ; Yongli LI ; Lü YINGRU ; Yan WU ; Shaolin LI ; Hanqi WANG ; Yaling PAN ; Tongtong CHEN ; Lü HAIYING ; Kaiping ZHAO ; Yuqin ZHANG ; Xiao MA ; Jing LU ; Xigang XIAO ; Xiangyang GONG ; Zehong YANG ; Wei CHEN ; Jianbo GAO ; Yuehua LI ; Xia DU ; Zhenlin LI ; Qiang ZENG ; Xiaoguang CHENG ; Shuang CHEN ; Jing WU ; Yong LU
Chinese Journal of Health Management 2022;16(9):604-609
Objective:To investigate the normal reference values of spinal bone mineral density measured by quantitative computed tomography (QCT) and the differences of bone mineral density (BMD) in different regions of in Chinese adult males.Methods:Men who underwent low-dose CT lung scan for cancer screening in regions of Northeast, North, East, South, Central and Southwest of China from January 2018 to December 2019 were selected. And the lumbar vertebrae BMD values in the male subjects were measured by the QCT system (Mindways Software, Inc.). The mean BMD values and their decline rates were calculated at an age interval of 10 years, and the prevalence of osteoporosis was calculated according to the American College of Radiology spine QCT osteoporosis diagnostic criteria.Results:A total of 50 682 males with a mean age of (50.22±12.79) years (ranged 20 to 98 years) were included in this study. The peak BMD of (173.11±28.56) mg/cm 3 in the healthy Chinese adult male population appeared in the age group of 20 to 29 years and then declined with age. Before the age of 70 years, the BMD was relatively higher in males in South China, and it was lower in Central China and Southwest China, and it was intermediate in Northeast, North and East of China, with statistically significant differences. There was no significant differences in BMD in the males in the two age groups of 70 to 79 years and 80 and older among the regions in China. The overall decline rate of spinal BMD in Chinese males under QCT was about 46.92% over the lifetime, and it declined obviouslyin the 40-49 age group. The overall prevalence of osteoporosis in Chinese male population aged 50 years and above was approximately 11.42%, with the highest prevalence in Southwest China and Central China (14.72% and 13.87%, respectively) and the lowest in North China and South China (8.53% and 7.71%, respectively). Conclusions:A reference of lumbar spine BMD values for healthy males in China based on QCT is established. BMD values were highest in South China and Lowest in Central China.
7.Reference value of lumbar spine bone mineral density and regional differences based on quantitative CT examination in healthy adult female in China
Ying JIN ; Kaiping ZHAO ; Jian QU ; Xia DU ; Yongli LI ; Shuang CHEN ; Yan WU ; Chunwei WU ; Guobin HONG ; Yong LU ; Yuqin ZHANG ; Xiao MA ; Jing LU ; Xigang XIAO ; Xiangyang GONG ; Zehong YANG ; Wei CHEN ; Miaomiao AN ; Ziyun WANG ; Siping NIE ; Lü YINGRU ; Jianbo GAO ; Shaolin LI ; Yuehua LI ; Qiang ZENG ; Xiaoguang CHENG ; Limei RAN
Chinese Journal of Health Management 2022;16(9):610-615
Objective:To establish the normal reference value of lumbar bone mineral density (BMD) under quantitative CT (QCT) in Chinese healthy adult females and to explore the regional differences.Methods:Total of 35 431 healthy women who met the inclusion criteria of Chinese health quantitative CT big data program were selected in this study. The BMD of the central plane of L 1 and L 2 vertebrae was measured by Mindways′s QCT system, and the mean value was taken. One-way analysis of variance was used to compare the BMD differences of lumbar vertebrae in women of different ages and regions. The subjects were grouped by an age interval of 10 years, and the level of BMD in different regions of the same age group were compaired. Results:The peak BMD of Chinese healthy adult women appeared in the age group of 20-29 years (Northeast China(183.01±24.58) mg/cm 3, North China (188.93±24.80) mg/cm 3, East China (187.54±27.71) mg/cm 3, South China (186.22±33.72) mg/cm 3, Central China (176.33±24.91) mg/cm 3, Southwest China(182.25±28.00) mg/cm 3), and then it decreased with age. The level of BMD in different regions decreased with the age. Before the age of 70 years, BMD in Central and Southwest China was always at a low level((176.23±24.91) to (90.38±28.12) mg/cm 3, 182.25±28.00 to (88.55±25.68) mg/cm 3), lower than those in Northeast China ((183.01±24.58) to (99.69±27.85) mg/cm 3), North China ((188.93±24.80) to (95.89±26.12) mg/cm 3), East China ((187.54±27.71) to (95.65±27.86) mg/cm 3). After 70 years of age, BMD tended to be the same in different regions ( P>0.05). The BMD values in Central China and Southwest China were similar in the age group of 40-60 years ( P>0.05). The BMD values in the health adult femles in the age group of 60 years in different regions of Chinawere all lower than those of bone mass abnormality (all P<0.05). The detection rate of osteoporosis in females over 50 years was the highest in Southwest China (25.65%) and it was the lowest in North China (17.30%). Conclusions:This study establishes reference values of BMD under QCT in healthy Chinese women, which can be used as a reference basis for identifying women with low BMD who are at risk of osteoporosis. The BMD value is the lowest in Southwest China and the highest in South China.
8.Correlation analysis of bone mineral density, hemoglobin and serum albumin in healthy population
Caiyun WANG ; Kaiping ZHAO ; Xiaojuan ZHA ; Limei RAN ; Shuang CHEN ; Yan WU ; Guobin HONG ; Yong LU ; Yuqin ZHANG ; Xiao MA ; Jing LU ; Xigang XIAO ; Xiangyang GONG ; Zehong YANG ; Wei CHEN ; Lü YINGRU ; Jianbo GAO ; Shaolin LI ; Yuehua LI ; Xia DU ; Qiang ZENG ; Xiaoguang CHENG ; Jing WU ; Yongli LI
Chinese Journal of Health Management 2022;16(9):616-622
Objective:To use quantitative computed tomography (QCT) technology to measure the bone mineral density of the spine of the Chinese healthy population, and to explore its correlation with hemoglobin and serum albumin.Methods:The data in this study came from the China Health Quantitative CT Big Data Project (China Biobank). The spine bone density was measured by using QCT Pro Image Analysis System and all cooperating centers used the European spine phantom (NO.145) for quality control. Total of 50 053 healthy persons who met the criteria for entry were selected as the research subjects. The subjects were divided into 7 groups according to age. The general data, spine bone density, serum albumin, hemoglobin of the subjects were collected. The single-factor analysis of variance, Pearson correlation analysis and multi-classification logistic regression model were applied to analyze the correlation between bone density and hemoglobin and serum albumin.Results:The bone mineral density of healthy people decreased with age ( P<0.05), and there were significant differences in hemoglobin, serum albumin and body mass index (BMI) among different age groups (all P<0.05). Linear correlation analysis showed that there were positive correlation between bone mineral density and hemoglobin in healthy males in different age groups ( r=0.086, 0.101, 0.076, 0.090, 0.072, 0.123, 0.100, all P<0.01). There were negative correlation between bone mineral density and hemoglobin in certain age groups in women (40-49 years group: r=-0.027; 70-79 yearsgroup: r=-0.077; both P<0.05). And corelation were found between bone mineral density and serum levels of albumin in certain age groups of healthy subjects (among men, 30-39 years group: r=-0.048; 40-49 years group, r=-0.027; 70-79 years group, r=-0.051; among women, 30-39 years group: r=-0.044; 40-49 years group, r=-0.042; 50-59 years group, r=-0.086; 70-79 years group, r=-0.070; all P<0.05). After adjusting for age and BMI, the multi-category logistic regression analysis showed that the hemoglobin level was protective factor of normal bone density ( OR=1.022, 95% CI:1.017-1.027) and decreased bone density ( OR=1.012, 95% CI:1.007-1.016) in healthy males, and the serum albumin was risk factor for normal bone density ( OR=0.926, 95% CI:0.905-0.948) and decreased bone density ( OR=1.006, 95% CI:0.951-1.011) in healthy women. Conclusion:There is a correlation between bone mineral density and hemoglobin and serum albumin in Chinese healthy population. Hemoglobin is a protective factor for bone mineral density in men, and serum albumin is a risk factor for bone mineral densityin women.
9.Application of Bodyfix fixation device in stereotactic body radiotherapy for elderly patients with lung cancer
Qi LIU ; Weiwei ZHONG ; Xiaoguang LU ; Dingyu LI ; Zu'an ZHENG ; Zhiping XIAO
Cancer Research and Clinic 2022;34(7):503-506
Objective:To explore the clinical application value of Bodyfix fixation device in stereotactic body radiotherapy (SBRT) for elderly patients with lung cancer.Methods:The clinical data of 63 elderly patients with lung cancer who received SBRT in Tongji Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology from January to October 2021 were retrospectively analyzed. According to different fixation methods, the patients were divided into Bodyfix combined with vacuum bag fixation device group (Bodyfix group, 20 cases) and 4D respiratory gating technology combined with vacuum bag fixation device group (vacuum bag group, 43 cases). Cone beam CT (CBCT) was used for position verification before each treatment, linear and rotational errors in the horizontal (X), head-to-foot (Y), front-to-back (Z) directions were recorded.Results:The linear errors of Bodyfix group in the X, Y and Z directions were 1.7 mm (1.3 mm, 3.0 mm), 4.6 mm (4.3 mm, 5.3 mm) and 1.3 mm (0.8 mm, 2.8 mm), and the rotational errors were (0.46±0.04)°, (-0.48±0.05)° and 0.64°(0.38°, 1.07°); the linear errors of vacuum bag group in the X, Y and Z directions were 2.1 mm (1.6 mm, 3.3 mm), 2.8 mm (1.8 mm, 3.7 mm) and 3.0 mm (2.3 mm, 3.8 mm), and the rotational errors were (0.69±0.04)°, (-0.70±0.04)° and 0.64° (0.42°, 0.86°). The differences in linear errors in the Y and Z directions and rotational errors in the X and Y directions between the two groups were statistically significant ( P values were <0.001, <0.001, 0.003 and 0.007). Conclusions:Compared with the 4D respiratory gating technology, the Bodyfix fixation device has smaller rotational errors in the X and Y directions and linear errors in the Z direction. It can be used as an effective method of postural fixation for SBRT in elderly patients with lung cancer.
10.Expert Consensus for Thermal Ablation of Pulmonary Subsolid Nodules (2021 Edition).
Xin YE ; Weijun FAN ; Zhongmin WANG ; Junjie WANG ; Hui WANG ; Jun WANG ; Chuntang WANG ; Lizhi NIU ; Yong FANG ; Shanzhi GU ; Hui TIAN ; Baodong LIU ; Lou ZHONG ; Yiping ZHUANG ; Jiachang CHI ; Xichao SUN ; Nuo YANG ; Zhigang WEI ; Xiao LI ; Xiaoguang LI ; Yuliang LI ; Chunhai LI ; Yan LI ; Xia YANG ; Wuwei YANG ; Po YANG ; Zhengqiang YANG ; Yueyong XIAO ; Xiaoming SONG ; Kaixian ZHANG ; Shilin CHEN ; Weisheng CHEN ; Zhengyu LIN ; Dianjie LIN ; Zhiqiang MENG ; Xiaojing ZHAO ; Kaiwen HU ; Chen LIU ; Cheng LIU ; Chundong GU ; Dong XU ; Yong HUANG ; Guanghui HUANG ; Zhongmin PENG ; Liang DONG ; Lei JIANG ; Yue HAN ; Qingshi ZENG ; Yong JIN ; Guangyan LEI ; Bo ZHAI ; Hailiang LI ; Jie PAN
Chinese Journal of Lung Cancer 2021;24(5):305-322
"The Expert Group on Tumor Ablation Therapy of Chinese Medical Doctor Association, The Tumor Ablation Committee of Chinese College of Interventionalists, The Society of Tumor Ablation Therapy of Chinese Anti-Cancer Association and The Ablation Expert Committee of the Chinese Society of Clinical Oncology" have organized multidisciplinary experts to formulate the consensus for thermal ablation of pulmonary subsolid nodules or ground-glass nodule (GGN). The expert consensus reviews current literatures and provides clinical practices for thermal ablation of GGN. The main contents include: (1) clinical evaluation of GGN, (2) procedures, indications, contraindications, outcomes evaluation and related complications of thermal ablation for GGN and (3) future development directions.
.