1.Survey on the awareness and clinical application of guidelines for the prevention and treatment of chronic hepatitis B (2022 edition) among clinicians
Yuanyuan KONG ; Yujie GUO ; Yujuan GUAN ; Xuan LIANG ; Zhongjie HU ; Xiaobo LU ; Mingqin LU ; Yongfeng YANG ; Meifang HAN ; Hong YOU ; Zhiyun YANG ; Jidong JIA
Journal of Clinical Hepatology 2025;41(6):1068-1074
ObjectiveTo investigate the awareness and clinical practice of guidelines for the prevention and treatment of chronic hepatitis B (2022 edition) among clinicians. MethodsFrom July 19 to December 31, 2024, a self-designed electronic questionnaire was distributed via the WeChat mini program to collect related data from 1 588 clinicians nationwide, including their awareness and practice based on 18 questions regarding testing and referral, diagnosis and treatment, and follow-up. ResultsAmong all respondents, only 350 clinicians correctly understood all the updated key points of antiviral indications and treatment for special populations in the 2022 edition of guidelines for the prevention and treatment of chronic hepatitis B, with an overall awareness rate of 22.0%. Only 20% — 40% of the patients with positive HBV DNA and an age of >30 years receive antiviral therapy, while 80% — 100% of the patients with positive HBV DNA and a family history of hepatitis B cirrhosis or hepatocellular carcinoma receive antiviral therapy. The median follow-up rates at 1 year, 3 years, and 5 years were 67.5% 57.5% and 47.5%,respectively, showing a trend of gradual reduction, which might be associated with the influencing factors such as insufficient time for follow-up management by clinicians, insufficient awareness of the disease among patients, and poor adherence to follow-up. ConclusionThere is a gap between the awareness and practice of guidelines for the prevention and treatment of chronic hepatitis B (2022 edition) among clinicians. It is recommended to further strengthen training and focus on the whole process of “detection, diagnosis, treatment, and management” for patients with chronic hepatitis B in healthcare institutions, in order to promote the implementation of the guidelines.
2.Application value of venous excess ultrasound score (VExUS Score) in patients with sepsis complicated acute kidney injury
Wei DA ; Tiantian ZHU ; Xiaobo WANG ; Peipei LIANG ; Xiaodong XIE ; Rui CHEN ; Ran LI ; Zhenxing DING ; Hong ZHANG
Chinese Journal of Emergency Medicine 2024;33(3):312-316
Objective:To evaluate the effect of venous excess ultrasound score (VExUS Score) in the acute kidney injury(AKI) in Patients with sepsis, so as to reduce the risk of disease and improve the prognosis of patients.Methods:This experiment was a single-center prospective cohort study. Include septic patients with AKI who were admitted to the Department of Emergency Intensive Care Unit of the First Affiliated Hospital of Anhui Medical University from February 2022 to February 2023, Those with inadequate window, inferior vena cava (IVC) thrombus, age<18 years and known case of cirrhosis with portal hypertension were excluded from the study. Patients underwent ultrasound examination with serial determination till AKI resolved or patient is initiated on dialysis.Results:Totally 86 patients were enrolled for the study. The mean age was (60.43±15.48) with 50 (58.1%) males. Mean sequential organ failure assessment (SOFA) score was (6.23±1.87). 38 patients (44.2%) were in AKI stage 1, while 24 patients (27.9%) were in AKI stage 2 and stage 3 each. 52 patients (60.5%) had VExUS grade Ⅲ. Resolution of AKI injury showed significant correlation with improvement in VExUS grade ( p value 0.003). Similarly, there was significant association between changes in VExUS grade and fluid balance ( p value 0.005). There was no correlation between central venous pressure (CVP), left ventricular function, and right ventricular function with change in VExUS grade. Conclusions:The study shows a significant correlation between the VExUS Score and AKI staging, With improvement in kidney function, there is decline in the VExUS grade as well. Moreover VExUS Score might reliably demonstrate venous congestion and aid in the clinical decision to perform fluid removal.
3.Evaluation of curative effects of arthroscopic external tension band fixation in the treatment of greater tubercle fracture of the humerus
Dawei HAN ; Huitao LIU ; Qingguo ZHANG ; Guoyin ZHANG ; Hanlong XIN ; Yang YANG ; Xiaobo ZHOU ; Junbo LIANG
Chinese Journal of Trauma 2024;40(1):65-72
Objective:To compare the clinical outcomes of arthroscopic external tension band fixation versus open reduction and internal fixation in the treatment of greater tubercle fracture of the humerus.Methods:A retrospective cohort study was conducted on 55 patients with greater tubercle fracture of the humerus admitted to Taizhou Hospital of Zhejiang Province from September 2019 to June 2022, including 24 males and 31 females, aged 26-80 years [(61.7±10.5)years]. Out of them, 35 patients treated with open reduction and internal fixation (open reduction group), and 20 patients were treated with external anchor tension band under arthroscopy (arthroscopy group). The operation time, and the Visual Analogue Scale (VAS) score, American Shoulder and Elbow Surgeons (ASES) score, Constant-Murley score and shoulder active range of motion (anterior flexion, abduction and posterior extension) before operation, at 1 month after operation and at the last follow-up were compared between the two groups. Bone healing was observed in both groups at the last follow-up. Postoperative complications were compared between the two groups.Results:All the patients were followed up for 12-29 months [(16.9±4.0)months]. There was no significant difference in operation time between the two groups ( P>0.05). There were no significant differences in the VAS score, ASES score, Constant-Murley score and shoulder active range of motion between the two groups before operation ( P>0.05). The VAS score of the arthroscopy group was 3(2, 3)points at 1 month after operation, which was significantly lower than that of the open reduction group [4(3, 4) points] ( P<0.01). No significant difference was found in the VAS score at the last follow-up between the two groups ( P>0.05).The ASES scores of the arthroscopy group were (70.6±4.2)points and (90.2±3.7)points at 1 month after operation and at the last follow-up respectively, which were significantly higher than those of the open reduction group [(64.7±6.4)points and (87.5±4.9)points respectively] ( P<0.05 or 0.01). There was no significant difference in the Constant-Murley score between the arthroscopy group [(71.8±4.3)points] and the open reduction group [(70.9±5.3)points] at 1 month after operation ( P>0.05), while the Constant-Murley score of the arthroscopy group was (94.1±3.1)points at the last follow-up, which was significantly higher than that of the open reduction group [(89.2±4.7)points] ( P<0.01). At 1 month after operation and at the last follow-up, ranges of motion of the anterior flexion, abduction and posterior extension were (52.7±12.3)° and (140.0±16.9)°, (57.4±8.6)° and (125.0±14.3)°, and 16(15, 19)° and 25(20, 30)° in the arthroscopy group respectively, which were significantly higher than those in the open reduction group [(42.2±5.2)° and (110.9±14.0)°, (52.8±6.0)° and (103.7±11.7)°, and 10(10, 20)° and 16(15, 25)° respectively] ( P<0.05 or 0.01). At the last follow-up, it was found that bony union was achieved in both groups. There were no obvious complications such as incision infection or joint stiffnessin both groups. In the open reduction group, 2 patients had internal fixation failure within 1-3 months after operation but was treated with revision operation; 6 patients developed shoulder stiffness at 3-6 months after operation but had outpatient rehabilitation. The incidence rate of postoperative complications in the arthroscopy group [0%(0/20)] was significantly lower than that in the open reduction group [23%(8/35)] ( P<0.05). Conclusion:Compared with open reduction and internal fixation with plates and screws, arthroscopic external anchor tension band fixation in the treatment of greater tuberosity fracture of the humerus has the advantages of earlier pain relief, better shoulder functional improvement, better recovery of shoulder mobility, and fewer complications.
4.Finite element simulation and experimental test of normal coracoclavicular ligament and flexible reconstruction
Guizhu JI ; Qiu ZHENG ; Wuxiang WANG ; Guan WANG ; Wen LI ; Xiaobo LU ; Ke DUAN ; Zhong LI ; Hongbin YANG ; Cheng LIANG
Chinese Journal of Tissue Engineering Research 2024;28(5):706-711
BACKGROUND:For dislocation of acromioclavicular joint induced by coracoclavicular ligament fracture,single EndoButton Plate reconstruction and double EndoButton Plates reconstruction are common repair methods.Further study on the stress distribution and fracture risk of the two repair methods is of great significance. OBJECTIVE:To study the biomechanical properties of the coracoclavicular ligament,and compare the fixation effect,stress distribution and failure mode of single and double EndoButton Plates reconstruction. METHODS:(1)Finite element simulation analysis:Mimics,Wrap and SolidWorks were used to establish normal coracoclavicular ligament,single EndoButton Plate reconstruction and double EndoButton Plates reconstruction.Ansys software was used to analyze the stress and deformation of the scapula and clavicle of each model under vertical load.(2)Sample experiment:Fifteen intact scapular-clavicle specimens were randomly grouped into five groups,with three specimens in each group.In group A,the acromioclavicular ligament was severed and the coracoclavicular ligament remained intact.In group B,acromioclavicular ligaments and trapeoid ligaments were severed,leaving intact conical ligaments.In group C,acromioclavicular ligaments and conical ligaments were cut off,and the intact traprex ligaments were retained.In group D,acromioclavicular and coracoclavicular ligaments were severed,and coracoclavicular ligaments were repaired by single EndoButton Plate reconstruction.In group E,acromioclavicular and coracoclavicular ligaments were severed,and the coracoclavicular ligaments were repaired by double EndoButton Plates reconstruction.The mechanical experiment was carried out by a mechanical testing machine to analyze the biomechanical status,stress distribution and failure patterns of the scapular-clavicle and clavicle. RESULTS AND CONCLUSION:(1)Finite element simulation analysis:The average stress of coracoclavicular ligament attached specimens was the lowest,and the risk of coracoclavicular fracture was less than that of single and double EndoButton Plates reconstruction.The mean stress of the coracoid process was similar in single and double EndoButton Plates reconstruction,and the fracture risk was similar.(2)Sample experiment:In groups A,B,C,D and E,the stiffness of specimens was(26.4±3.5),(19.8±2.8),(21.3±3.2),(57.7±4.1),and(46.2±2.8)N/mm,respectively;the ultimate loads were(545.5±53.7),(360.1±42.1),(250.9±44.4),(643.5±39.1),and(511.9±31.7)N,respectively;global stiffness in groups D and E was higher than that in group A(P=0.000 06,0.000 3);ultimate load in group D was higher than that in group A(P<0.05);the ultimate load was not significantly different between the group E and group A(P>0.05).Ligament fracture was observed in groups A,B and C and coracoid process fracture was found in groups D and E.(3)These results suggest that from the biomechanical analysis,Single EndoButton Plate reconstruction and double EndoButton Plates reconstruction are effective treatment techniques for coracoclavicular ligament fracture in acromioclavicular joint dislocation,but increase the risk of fracture.The double EndoButton Plates reconstruction dispersed the stress of the steel plate and reduced the contact force between the steel plate and bone,but slightly reduced the ultimate bearing capacity.Single and double EndoButton Plates reconstruction should be selected according to the actual clinical situation.
5.Finite element and biomechanical analysis of different implants in repair for unilateral unstable pelvic posterior ring injury
Cheng LIANG ; Linqi ZHANG ; Guan WANG ; Wen LI ; Ke DUAN ; Zhong LI ; Xiaobo LU ; Naiqiang ZHUO
Chinese Journal of Tissue Engineering Research 2024;28(9):1336-1341
BACKGROUND:The stability of the pelvis is mainly determined by the posterior pelvic ring and the sacroiliac joint.The posterior pelvic ring injury and the dislocation of the sacroiliac joint caused by high energy impacts such as car accidents increase year by year.Surgical treatment is the best method,and there are many kinds of endophytorepair methods in clinical practice,but which treatment method has the best biomechanical properties is still controversial. OBJECTIVE:To compare the biomechanical properties of three kinds of internal implants:anterior double plates,posterior bridging plate and tension nail in the repair of unilateral unstable pelvic posterior ring injury,to provide a reference for the clinical treatment and development of a new pelvic tension screw. METHODS:(1)Finite element simulation:Mimics,Wrap and SolidWorks were used to establish normal pelvic model,unilateral injured pelvis model,and three kinds of internal implant repaired models(anterior double plates,posterior bridging plate and tension nail).Ansys was used to analyze the stress and deformation of the models.(2)Biomechanical test:A total of 15 intact pelvic specimens were randomly grouped into five groups,normal pelvic model,unilateral injured pelvis model,anterior double plates,posterior bridging plate and tension nail groups.The mechanical test was performed using an Instron E10000 testing machine. RESULTS AND CONCLUSION:(1)Simulation:In the normal pelvic model,the average displacement of the sacrum was 0.174 mm,and the maximum stress of the sacral iliac bone was 10.51 MPa,and the stress distribution was uniform.The mean sacral displacement of the unilateral injured pelvis model was 0.267 mm,and the stress concentration of the model was obvious.The mean displacement of the sacrum in the three repaired models was close to that in the normal pelvic model,and the stress distribution of the sacral iliac bone in the tension nail repaired model was uniform.(2)Mechanical test:The stiffness of the normal pelvic model was(226.38±4.18)N/mm,and that of the unilateral unstable pelvic model was the smallest(130.02±2.19)N/mm.The deviation of the normal pelvic model stiffness and the three repaired models'stiffness were all within(±10%),and the repair effect was obvious.(3)The simulation results were in agreement with the experimental results.(4)The biomechanics of the tension nail repaired model was the most similar to that of the normal pelvis,and this method was the best.The repairing stiffness of the anterior double plate was too large,and the stress shielding effect was more significant.The posterior bridging plate repair could not solve the compensatory effect of the normal side soft tissue and had defects.This study provides an optimal basis for clinical surgery.(5)The new type of pelvic tension nail should be improved from the point of view of the tension nail to retain the good biomechanical properties of the tension nail,while adding other advantages,such as being used for the osteoporotic pelvis.
6.Analysis of the diagnosis and treatment experience and etiological characteristics of 119 cases of primary canaliculitis
Qinghua WANG ; Zhengwei ZHANG ; Qiuhong WANG ; Shui LU ; Xiaobo GU ; Liang GUO ; Yunjia JIANG
International Eye Science 2024;24(1):144-148
AIM: To explore the clinical features, diagnosis and treatment experience and the distribution characteristics of pathogenic microorganisms of primary canaliculitis, and provide reference for its diagnosis and treatment. METHODS: Retrospective clinical study. A total of 119 cases(120 eyes)diagnosed as primary canaliculitis in the department of ophthalmology of Wuxi No.2 People's Hospital from June 2019 to February 2023 were included. The treatment methods were mainly divided into conservative treatment(removing canaliculus stones through lacrimal punctum combined with injecting antibiotic eye ointment into the tube)and surgical treatment. The inspection methods of pathogenic microorganisms included secretion smear microscopy and microbial culture.RESULTS: Primary canaliculitis was more common in middle-aged and older female, mainly manifested by long-term red eye and increased secretion; however, the majority was not accompanied by tearing. Totally, 118 cases(99.2%)had monocular disease, while 63 cases(63 eyes; 52.5%)had inferior lacrimal canaliculus disease. Laboratory examination: Among 119 cases(120 eyes), 4 cases(4 eyes)did not undergo laboratory examination, and the other 115 cases(116 eyes)were as follows: Gram staining microscopy of secretion smear showed that Actinomyces were detected in 102 cases(103 eyes; 88.8%), while no fungus was detected; Microbial culture: 85 cases(86 eyes; 74.1%)were positive for bacterial culture. A total of 111 bacterial strains were cultured, which contained 26 types of bacteria. Among them, 32 strains were aerobic(28.8%); 26 strains were anaerobic(23.4%); and 53 strains were facultative anaerobic(47.7%). The most common bacteria were streptococcus(20 strains), staphylococcus(13 strains), Propionibacterium(10 strains), and capnocytophaga(10 strains). Only 4 cases(4 eyes; 3.4%)of microbial cultures were positive for Actinomyces. Fungus was negative in all microbial cultures. Treatment: Of the 119 cases(120 eyes), 114 cases(115 eyes; 95.8%)were cured by conservative treatment of removing lacrimal canaliculus stones through lacrimal punctum and intracanalicular ointment infiltration(IOI), while 5 cases(5 eyes)were not effective in conservative treatment; however, all of them were cured after surgical treatment, and the cure rate for primary canaliculitis was 100.0%.CONCLUSION: The incidence of primary canaliculitis is low, and it is prevalent in middle-aged and older female. Single lacrimal canaliculus is more common, which could be missed and misdiagnosed in clinic. Actinomyces is the major pathogen observed mostly in mixed infections, with heterogeneous strains, mainly anaerobic or facultative anaerobic bacteria. Streptococcus and Staphylococcus are the most common whereas fungal canaliculitis is rare. The cure rate of primary canaliculitis is high after diagnosis, and IOI method is recommended as the initial treatment of canaliculitis.
7.Effect of case-integrated scenario simulation instruction model on probationary instruction of acute upper gastrointestinal bleeding
Xiaobo LAI ; Songsong YING ; Peizhi LIANG ; Qingning LI ; Wenjuan TANG ; Yongjian ZHOU
Modern Hospital 2024;24(8):1306-1308,1312
Objective To explore the teaching effect of case-integrated scenario simulation instruction model on proba-tionary instruction of acute upper gastrointestinal bleeding.Methods A total of 40 medical students of grade 2021 majoring in clinical medicine,namely,Nanshan Class,from Guangzhou Medical University were selected as participants.The students were randomly divided into two groups,with 22 as an experimental group and 18 as a control group.The former group received the case-integrated based scenario simulation teaching model,while the latter adopted the traditional bedside teaching model.The teaching content was on acute non-variceal upper gastrointestinal bleeding.Results There was no statistically significant differ-ence in the total score of gastroenterology between the experimental group and the control group(P>0.05).The experimental group scored significantly higher in the gastrointestinal bleeding-related contents compared to the control group(P<0.05).The post-class survey revealed that the majority of the students in the research group expressed their high-level satisfaction with the new instruction model and demonstrated their greater interests in participation in the new instruction model.Conclusion The case-integrated scenario simulation instruction model demonstrates significant superiority to the traditional bedside teaching model in terms of stimulating learning interests,cultivating medical professionalism,and enlivening classroom atmosphere.It is suitable for practical teaching in gastroenterology and can be widely adopted as routine probationary teaching for undergraduate students.
8.Evaluation of Mechanical Properties of a Novel Sacroiliac Lag Screw
Cheng LIANG ; Chuanchuan ZHUO ; Guan WANG ; Wen LI ; Ke DUAN ; Zhong LI ; Xiaobo LU ; Naiqiang ZHUO
Journal of Medical Biomechanics 2024;39(2):265-271
Objective To investigate the biomechanical properties of a novel sacroiliac lag screw with a spiral blade.Methods Percutaneous sacroiliac lag screws were used as the controls.Polyurethane material was used to simulate the trabecular bone,and the pullout resistance performance was tested on an Instron mechanical testing machine.Subsequently,pelvic specimens were utilized to analyze the static stiffness and dynamic stability of the novel sacroiliac lag screw in repairing sacroiliac joint injuries under normal standing conditions,with normal pelvis,single-sided sacroiliac joint injury pelvis,percutaneous sacroiliac lag screw-single screw repair,and percutaneous sacroiliac lag screw-double screw repair as controls.Results The damage to the polyurethane material after screw extraction was smaller in the novel sacroiliac lag screw group.The average effective holding displacement of the novel sacroiliac lag screw was significantly greater than that of the percutaneous sacroiliac lag screw(P<0.05).However,the maximum resistance to the pullout force for the percutaneous sacroiliac lag screw was significantly higher than that for the novel sacroiliac lag screw(P<0.05).The stiffness after repair of sacroiliac joint injuries was significantly higher when using a single sacroiliac lag screw than when using two percutaneous sacroiliac lag screws(P<0.05).The displacement amplitude was the highest in the sacroiliac joint injury group,followed by that in the normal group.The displacement amplitudes in the other groups were similar;however,the differences were statistically significant(P<0.05).The dynamic stability of the sacroiliac lag screw repair group was the best,slightly better than that of the percutaneous sacroiliac lag screw-double screw repair group,and the dynamic stability of the sacroiliac joint injury group was the worst.The novel sacroiliac lag screw effectively repaired the sacroiliac joint injuries.Conclusions The novel sacroiliac lag screw can effectively hold the trabecular bone and has practical clinical utility.
9.Clinical effects of modified arthroscopic lower trapezius tendon transfer with autologous hamstring tendon bridging for irreparable massive posterosuperior rotator cuff tears
Dawei HAN ; Qingguo ZHANG ; Li YING ; Linlin SHA ; Yu HUI ; Liwei YING ; Junbo LIANG ; Xiaobo ZHOU
Chinese Journal of Orthopaedics 2024;44(14):947-955
Objective:To assess the efficacy of modified arthroscopic lower trapezius transfer with autologous hamstring tendon bridging for irreparable massive posterosuperior rotator cuff tears.Methods:A retrospective analysis was conducted on 59 patients (11 males and 48 females; mean age 66.70±6.10 years, range 55-79 years) treated between June 2019 and November 2022 for posterior superior irreparable massive rotator cuff tears. The treatment involved total arthroscopic oblique muscle transposition combined with partial rotator cuff repair. Shoulder mobility was measured in active supination, forward flexion, posterior external rotation, and abduction external rotation before surgery and at the final follow-up. The Constant-Murley shoulder function score, visual analogue scale (VAS) for pain, and American Shoulder and Elbow Surgeons (ASES) scores were assessed preoperatively, at 3 months, 6 months postoperatively, and at the final follow-up. MR examinations were conducted preoperatively and at 3, 6, and 12 months postoperatively to evaluate rotator cuff healing and retear rates.Results:All surgeries were successfully completed using an average of 3.2±0.5 anchor nails (range 3-5) per case. The mean follow-up period was 15.9±5.7 months (range 12-37 months). Significant improvements in shoulder mobility were observed postoperatively compared to preoperative measurements. The mean body external rotation angle increased from 12.0°±19.4° preoperatively to 35.3°±19.6° at the final follow-up ( P<0.05), and the mean abduction external rotation angle increased from 33.4°±22.4° to 43.4°±23.1° ( P<0.05). The mean preoperative abduction angle improved from 121.7°±47.9° to 136.4°±40.6° ( P<0.05), and the mean forward flexion supination angle improved from 117.6°±45.8° to 139.5°±33.7° ( P<0.05). Postoperative VAS scores significantly improved from 4.8±1.8 preoperatively to 0.3±0.8 at the final follow-up ( F=104.868, P<0.001). The ASES scores improved from 42.0±14.9 preoperatively to 71.7±14.6 at the final follow-up ( F=47.287, P<0.001). The Constant-Murley scores increased from 54.3±17.1 preoperatively to 76.4±13.0 at the final follow-up ( F=44.082, P<0.001). Postoperative complications included 2 complete tears and 7 partial tears (re-tear rate 15.3%). No serious complications such as shoulder joint infection, joint stiffness, or vascular nerve injury were observed. One patient developed a localized subcutaneous hematoma at the tendon extraction site, and another developed deep vein thrombosis of the lower extremity, which improved with symptomatic anticoagulation. Conclusion:Modified arthroscopic lower trapezius transfer with autologous hamstring tendon bridging effectively reduces shoulder pain, improves shoulder joint activity and function scores, and is associated with a low rate of surgical complications for patients with irreparable massive posterosuperior rotator cuff tears.
10.Hybrid fixation strategy using 3D-printed porous tantalum augments for severe bone defects in total knee arthroplasty: an early follow-up study
Pengfei LEI ; Xiaobo ZHU ; Chi ZHANG ; Feng LIANG ; Xianfeng LOU ; Jie XIE ; Ting WEN ; Da ZHONG ; Fengchao ZHAO ; Zhiheng LING ; Yihe HU
Chinese Journal of Orthopaedics 2024;44(22):1457-1463
Objective:To explore the early effects and safety of using a hybrid fixation strategy with 3D-printed porous tantalum metal augments to reconstruct substantial bone defects in complex primary total knee arthroplasty (TKA).Methods:A retrospective analysis was performed on the clinical data from August 2019 to September 2023, encompassing 20 patients (21 knees) with significant bone loss who underwent hybrid fixation with 3D-printed porous tantalum augments. The procedures were conducted at two medical centers: the First Affiliated Hospital, School of Medicine, Zhejiang University (11 cases) and Xiangya Hospital of Central South University (9 cases). The study cohort comprised 6 males (6 knees) and 14 females (15 knees), with a mean age of 61.05±11.23 years (range, 42-80 years). The distribution of cases was 7 on the left side and 14 on the right side. All cases were categorized as type 3 according to the Anderson Orthopaedic Research Institute (AORI) classification system. The cohort included 19 unilateral and 1 bilateral case, with 5 involving complex primary replacements (3 with Charcot arthropathy, 1 with syphilitic arthropathy, and 1 with severe valgus deformity) and 16 revision surgeries (13 for aseptic loosening and 3 for infection). Preoperative assessments included routine CT scans and digital three-dimensional reconstructions to identify large metaphyseal defects exceeding 50% of the metaphyseal area or those thicker than 10 mm. For such defects, 3D-printed standardized porous tantalum augments were implemented. In cases of extensive cavitary bone defects or severe metaphyseal defects where the medial and lateral defects collectively exceeded 80% of the metaphyseal region or where the residual bone stock was insufficient for screw fixation of standardized augments, 3D-printed personalized custom-made porous tantalum augments were employed for hybrid fixation and repair. Comparative analyses were conducted on pre- and postoperative imaging data (prosthesis positioning and complications), knee range of motion (ROM), visual analogue scale (VAS) for pain, and Knee Society score (KSS).Results:Of the cases, 17 were repaired using standardized 3D-printed porous tantalum augments, while 4 underwent repairs with customized augments for hybrid fixation. Follow-up averaged 26.5±15.0 months (range, 12-62 months). There was a significant increase in knee ROM, improving from 72.8°±31.9° preoperatively to 113.2°±6.8° at 12 months postoperatively ( P<0.05). VAS scores decreased from 6.6±1.4 preoperatively to 2.5±1.0 at 12 months postoperatively ( P<0.05). Similarly, KSS improved from 52.8±6.4 preoperatively to 80.7±7.9 at 12 months postoperatively ( P<0.05). There were no incidences of prosthesis displacement, poor bone integration, or postoperative infections. Conclusion:The hybrid fixation strategy employing 3D-printed porous tantalum augments has been found to be effective in addressing significant bone defects in TKA. The follow-up results indicate a satisfactory biological integration of the porous tantalum metal augments with the host bone, which has resulted in substantial improvements in pain relief and knee joint functionality.

Result Analysis
Print
Save
E-mail