1.Rapid Identification of Different Parts of Nardostachys jatamansi Based on HS-SPME-GC-MS and Ultra-fast Gas Phase Electronic Nose
Tao WANG ; Xiaoqin ZHAO ; Yang WEN ; Momeimei QU ; Min LI ; Jing WEI ; Xiaoming BAO ; Ying LI ; Yuan LIU ; Xiao LUO ; Wenbing LI
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(2):182-191
ObjectiveTo establish a model that can quickly identify the aroma components in different parts of Nardostachys jatamansi, so as to provide a quality control basis for the market circulation and clinical use of N. jatamansi. MethodsHeadspace solid-phase microextraction-gas chromatography-mass spectrometry(HS-SPME-GC-MS) combined with Smart aroma database and National Institute of Standards and Technology(NIST) database were used to characterize the aroma components in different parts of N. jatamansi, and the aroma components were quantified according to relative response factor(RRF) and three internal standards, and the markers of aroma differences in different parts of N. jatamansi were identified by orthogonal partial least squares-discriminant analysis(OPLS-DA) and cluster thermal analysis based on variable importance in the projection(VIP) value >1 and P<0.01. The odor data of different parts of N. jatamansi were collected by Heracles Ⅱ Neo ultra-fast gas phase electronic nose, and the correlation between compound types of aroma components collected by the ultra-fast gas phase electronic nose and the detection results of HS-SPME-GC-MS was investigated by drawing odor fingerprints and odor response radargrams. Chromatographic peak information with distinguishing ability≥0.700 and peak area≥200 was selected as sensor data, and the rapid identification model of different parts of N. jatamansi was established by principal component analysis(PCA), discriminant factor alysis(DFA), soft independent modeling of class analogies(SIMCA) and statistical quality control analysis(SQCA). ResultsThe HS-SPME-GC-MS results showed that there were 28 common components in the underground and aboveground parts of N. jatamansi, of which 22 could be quantified and 12 significantly different components were screened out. Among these 12 components, the contents of five components(ethyl isovalerate, 2-pentylfuran, benzyl alcohol, nonanal and glacial acetic acid,) in the aboveground part of N. jatamansi were significantly higher than those in the underground part(P<0.01), the contents of β-ionone, patchouli alcohol, α-caryophyllene, linalyl butyrate, valencene, 1,8-cineole and p-cymene in the underground part of N. jatamansi were significantly higher than those in the aboveground part(P<0.01). Heracles Ⅱ Neo electronic nose results showed that the PCA discrimination index of the underground and aboveground parts of N. jatamansi was 82, and the contribution rates of the principal component factors were 99.94% and 99.89% when 2 and 3 principal components were extracted, respectively. The contribution rate of the discriminant factor 1 of the DFA model constructed on the basis of PCA was 100%, the validation score of the SIMCA model for discrimination of the two parts was 99, and SQCA could clearly distinguish different parts of N. jatamansi. ConclusionHS-SPME-GC-MS can clarify the differential markers of underground and aboveground parts of N. jatamansi. The four analytical models provided by Heracles Ⅱ Neo electronic nose(PCA, DFA, SIMCA and SQCA) can realize the rapid identification of different parts of N. jatamansi. Combining the two results, it is speculated that terpenes and carboxylic acids may be the main factors contributing to the difference in aroma between the underground and aboveground parts of N. jatamansi.
2.Construction of a nomogram model for predicting risk of spread through air space in sub-centimeter non-small cell lung cancer
Xiao WANG ; Yao ZHANG ; Kangle ZHU ; Yi ZHAO ; Jingwei SHI ; Qianqian XU ; Zhengcheng LIU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(03):345-352
Objective To investigate the correlation between spread through air space (STAS) of sub-centimeter non-small cell lung cancer and clinical characteristics and radiological features, constructing a nomogram risk prediction model for STAS to provide a reference for the preoperative planning of sub-centimeter non-small cell lung cancer patients. Methods The data of patients with sub-centimeter non-small cell lung cancer who underwent surgical treatment in Nanjing Drum Tower Hospital from January 2022 to October 2023 were retrospectively collected. According to the pathological diagnosis of whether the tumor was accompanied with STAS, they were divided into a STAS positive group and a STAS negative group. The clinical and radiological data of the two groups were collected for univariate logistic regression analysis, and the variables with statistical differences were included in the multivariate analysis. Finally, independent risk factors for STAS were screened out and a nomogram model was constructed. The sensitivity and specificity were calculated based on the Youden index, and area under the curve (AUC), calibration plots and decision curve analysis (DCA) were used to evaluate the performance of the model. Results A total of 112 patients were collected, which included 17 patients in the STAS positive group, consisting of 11 males and 6 females, with a mean age of (59.0±10.3) years. The STAS negative group included 95 patients, with 30 males and 65 females, and a mean age of (56.8±10.3) years. Univariate logistic regression analysis showed that male, anti-GAGE7 antibody positive, mean CT value and spiculation were associated with the occurrence of STAS (P<0.05). Multivariate regression analysis showed that associations between STAS and male (OR=5.974, 95%CI 1.495 to 23.872), anti-GAGE7 antibody positive (OR=11.760, 95%CI 1.619 to 85.408) and mean CT value (OR=1.008, 95%CI 1.004 to 1.013) were still significant (P<0.05), while the association between STAS and spiculation was not significant anymore (P=0.438). Based on the above three independent predictors, a nomogram model of STAS in sub-centimeter non-small cell lung cancer was constructed. The AUC value of the model was 0.890, the sensitivity was 76.5%, and the specificity was 91.6%. The calibration curve was well fitted, suggesting that the model had a good prediction efficiency for STAS. The DCA plot showed that the model had a good clinically utility. Conclusion Male, anti-GAGE7 antibody positive and mean CT value are independent predictors of STAS positivity of sub-centimeter non-small cell lung cancer, and the nomogram model established in this study has a good predictive value and provides reference for preoperative planning of patients.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Analysis of the efficacy and prognosis of radiotherapy in acute leukemia with extramedullary infiltration
Wenbin LEI ; Hui LIU ; Yan ZHANG ; Yinghao LU ; Yi HUANG ; Ying CHEN ; Rui GAO ; Xiao CHAI ; Yun ZHAN ; Jie XIONG ; Lingyun WANG ; Lei LIU ; Jishi WANG ; Peng ZHAO
Chongqing Medicine 2024;53(4):547-554
Objective To investigate the clinical characteristics,treatment methods,and prognosis of a-cute leukemia patients with extramedullary infiltration.Methods The clinical characteristics and treatment methods of 47 acute leukemia patients with extramedullary infiltration admitted to the Affiliated Hospital of Guizhou Medical University from April 2014 to April 2023 were retrospectively analyzed.Subgroup analysis was performed according to whether there was extramedullary infiltration before transplantation,and whether there was isolated extramedullary recurrence after transplantation.Based on this analysis,the patients were di-vided into the pre-transplantation radiotherapy group and pre-transplantation non-radiotherapy group,the post-transplantation radiotherapy group and post-transplantation non-radiotherapy group.According to the treatment methods of central nervous system leukemia(CNSL),the patients were divided into the intrathecal injection group(n=12)and combination of intrathecal injection and radiotherapy group(n=13).The local remission situation,survival duration,and toxic and side effects of radiotherapy and chemotherapy were com-pared.Results For acute leukemia patients with extramedullary infiltration,the overall survival time(OS)in the radiotherapy group was better than that in the non-radiotherapy group(median OS:706 d vs.151 d,P=0.015).Subgroup analysis showed that the OS of the pre-transplantation radiotherapy group was better than that of the pre-transplantation non-radiotherapy group(median OS:592 d vs.386 d,P=0.035).For CNSL,the combination of intrathecal injection and radiotherapy group had a better OS than the intrathecal injection group(median OS:547 d vs.388 d,P=0.045).The event-free survival time(EFS)of the radiotherapy group was better than that of the non-radiotherapy group(median EFS:175 d vs.50 d,P=0.005).The COX pro-portional-hazards model showed that treatment with or without radiotherapy had a significant impact on the OS of acute leukemia patients with extramedullary infiltration.The risk of death in the pre-transplantation non-radiotherapy group was 2.231 times higher than that in the pre-transplantation radiotherapy group(HR=3.231,95%CI:1.021-10.227,P=0.046).Compared with the non-radiotherapy group,the radiother-apy group had a higher local remission and a lower risk of haematological toxicity,infection,and haemorrhage.Conclusion Radiotherapy can rapidly alleviate the local symptoms of acute leukemia complicated with extr-amedullary infiltration,prolong the survival time of these patients,and reduce the risk of hematologic toxicity,infection,and haemorrhage.
9.Visualization Analysis of Artificial Intelligence Literature in Forensic Research
Yi-Ming DONG ; Chun-Mei ZHAO ; Nian-Nian CHEN ; Li LUO ; Zhan-Peng LI ; Li-Kai WANG ; Xiao-Qian LI ; Ting-Gan REN ; Cai-Rong GAO ; Xiang-Jie GUO
Journal of Forensic Medicine 2024;40(1):1-14
Objective To analyze the literature on artificial intelligence in forensic research from 2012 to 2022 in the Web of Science Core Collection Database,to explore research hotspots and developmen-tal trends.Methods A total of 736 articles on artificial intelligence in forensic medicine in the Web of Science Core Collection Database from 2012 to 2022 were visualized and analyzed through the litera-ture measuring tool CiteSpace.The authors,institution,country(region),title,journal,keywords,cited references and other information of relevant literatures were analyzed.Results A total of 736 articles published in 220 journals by 355 authors from 289 institutions in 69 countries(regions)were identi-fied,with the number of articles published showing an increasing trend year by year.Among them,the United States had the highest number of publications and China ranked the second.Academy of Forensic Science had the highest number of publications among the institutions.Forensic Science Inter-national,Journal of Forensic Sciences,International Journal of Legal Medicine ranked high in publica-tion and citation frequency.Through the analysis of keywords,it was found that the research hotspots of artificial intelligence in the forensic field mainly focused on the use of artificial intelligence technol-ogy for sex and age estimation,cause of death analysis,postmortem interval estimation,individual identification and so on.Conclusion It is necessary to pay attention to international and institutional cooperation and to strengthen the cross-disciplinary research.Exploring the combination of advanced ar-tificial intelligence technologies with forensic research will be a hotspot and direction for future re-search.
10.Influence of Modified Shashen Maidong Decoction Combined with Camrelizumab Immunotherapy Plus Chemotherapy on the Efficacy,Survival Status,and Serum CYFRA21-1 and NSE Levels in Patients with Advanced Non-Small Cell Lung Cancer
Hai-Feng WANG ; Yi-Qun ZHAO ; Xiao-Li DU ; Lu LIU ; Bao-Song HOU ; Wen-Yan ZHAN
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(3):606-611
Objective To investigate the influence of modified Shashen Maidong Decoction combined with Camrelizumab immunotherapy plus chemotherapy on the efficacy,survival status and serum cytokeratin 19 fragment(CYFRA21-1)and neuron-specific enolase(NSE)levels in patients with advanced non-small cell lung cancer(NSCLC).Methods Forty patients with advanced NSCLC of lung-stomach yin deficiency with intense heat-toxin type were randomly divided into a control group and a study group,with 20 patients in each group.The patients in the control group were given Camrelizumab immunotherapy plus chemotherapy,and the patients in the study group were given modified Shashen Maidong Decoction combined with Camrelizumab immunotherapy plus chemotherapy,with 21 days as a course of treatment and for a total of 4 courses of treatment.The changes of serum NSE and CYFRA21-1 levels in the two groups before and after treatment were observed,and the clinical efficacy,survival status and the incidence of toxic and side effects were compared between the two groups.Results(1)After 4 courses of treatment,the total effective rate of the study group was 70.00%(14/20),which was significantly higher than that of the control group(9/20,45.00%),but the intergroup comparison(tested by chi-square test)showed that the difference was not statistically significant(P>0.05).(2)After 2 years of follow-up,the overall survival(OS),time to progression(TTP),and progression-free survival(PFS)of the patients in the study group were significantly prolonged compared with those in the control group(P<0.01).(3)After treatment,the serum NSE and CYFRA21-1 levels of the patients in the two groups were decreased compared with those before treatment(P<0.05),and the decrease of serum NSE and CYFRA21-1 levels in the study group was significantly superior to that in the control group(P<0.01).(4)The incidence of toxic and side effects in the study group was 25.00%(5/20),which was significantly lower than that of 65.00%(13/20)in the control group,and the intergroup comparison showed that the difference was statistically significant(P<0.05).Conclusion Modified Shashen Maidong Decoction combined with Camrelizumab immunotherapy plus chemotherapy has satisfactory therapeutic effect on patients with advanced NSCLC,which can reduce the toxic and side effects of chemotherapy,lower the level of serum tumor markers,and prolong the survival period and time to progression(TTP)of the patients.

Result Analysis
Print
Save
E-mail