1.Effect of hand hygiene intervention on healthcare-associated case infection incidence from 2014 to 2022
Jia-Yan DING ; Rui-Hong SHEN ; Wen-Qin ZHOU ; Ya-Yun YUAN ; Mei HUANG ; Ya YANG ; Bing-Chao CAI ; Hai-Qun BAN ; Xiao-Fang FU
Chinese Journal of Infection Control 2024;23(2):208-213
Objective To observe the effect of multi-modal hand hygiene(HH)intervention on HH compliance,as well as the relationship between HH compliance and the healthcare-associated(HA)case infection incidence.Methods From 2014 to 2022,the infection control team in a tertiary first-class hospital implemented multi-modal HH intervention for health care workers(HCWs).The changing trend of HH monitoring data,the correlation be-tween HH compliance rate and HA case infection incidence were analyzed retrospectively.Results The consump-tion of HH products in the wards showed a stable upward trend;HH compliance rate increased from 64.98%in 2014 to 85.01%in 2022(P<0.001),and HA case infection incidence decreased from 1.21%to 0.83%(P<0.05).HH compliance rate was negatively correlated with HA case infection incidence(r=-0.369,P=0.027).HH compliance rates in different regions and job posts in each quarter were increased(P<0.001).For 5 different HH moments in each quarter,HH compliance rate fluctuated slightly before sterile manipulation and after touching patient;presented rising trend after touching surroundings around patient,and decreased before touching patient and after touching patient's body fluid since 2020(P<0.001).Conclusion Multi-modal HH intervention can im-prove the HH compliance of HCWs,improving their HH awareness is conducive to reducing HA case infection incidence.
2.The effectiveness of fluorescence labeling-based assay bundle intervention in the prevention and control of multidrug-resistant organism infection
Ting-Zheng QIN ; Yun LIU ; Yue-Wei HAO ; Na YANG ; Ya-Teng SONG ; Xiao-Qun WANG ; Wei-Guang LI
Chinese Journal of Infection Control 2024;23(2):225-230
Objective To observe the effectiveness of fluorescence labeling-based assay bundle intervention in the prevention and control of multidrug-resistant organism(MDRO)infection.Methods Patients who were detected MDRO in a hospital from January to December 2022 were selected as the research subjects.MDRO monitoring data and implementation status of prevention and control measures were collected.Fluorescence labeling assay was adopted to monitor the cleaning and disinfection effectiveness of the surrounding object surface of the bed units.Based on the bundled prevention and control measures as well as management mode of the pre-intervention group,the post-intervention group implemented enhanced rectification measures for the problems found by the pre-interven-tion group.Changes in relevant indicators between January-June 2022(before intervention)and July-December 2022(after intervention)were compared.Results There were 136 MDRO-infected patients in the pre-intervention group,208 MDRO strains were detected and 10 healthcare-associated infection(HAI)occurred.There were 128 MDRO-infected patients in the post-intervention group,198 MDRO strains were detected and 9 HAI occurred.Af-ter intervention,the total detection rates of methicillin-resistant Staphylococcus aureus(MRSA),carbapenem-re-sistant Acinetobacter baumannii(CRAB),and total MDRO from patients decreased significantly compared to before intervention(all P<0.05).After intervention,the detection rates of MRSA,carbapenem-resistant Pseudomonas aeruginosa(CRPA),CRAB,and total MDRO from the surrounding object surface were all lower than those before intervention(all P<0.05).The detection rate of MDRO from surrounding object surface before intervention was 34.52%,which showed a decreased trend after intervention(P<0.05).The clearance rate of fluorescent labeled markers before intervention was 41.84%,which showed an upward trend after implementing intervention measures(from July to December),and increased to 85.00%at the end of intervention(November-December).The comp-liance rates of issuing isolation medical orders,placing isolation labels,using medical supplies exclusively,and cor-rectly handling medical waste after intervention have all increased compared to before intervention(all P<0.05).Conclusion Adopting fluorescence labeling-based assay bundle intervention can effectively improve the effectiveness of MDRO infection prevention and control.
3. In vitro bacteriostatic and serum pharmacological tests of Qiguiyin decoction combined with levofloxacin against pseudomonas aeruginosa
Xiao-Jing LAI ; Wan-Qiao ZHANG ; Yan-Ling LI ; Yu-Ying GUO ; Ming QIN ; Guang XU ; Li JI ; Qun MA ; Jun WU ; Qing-Quan LIU
Chinese Pharmacological Bulletin 2023;39(6):1182-1189
Aim To investigate the antibacterial activity and anti-resistant mutation ability of Qiguiyin decoction (a traditional Chinese herbal formula) combined with levofloxacin against pseudomonas aeruginosa byantibacterial experiment in vitro and serum pharmacology. Methods The minimal inhibitory concentrations (MICs) of levofloxacin and Qiguiyin decoction were detected respectively by the broth dilution technique.The MIC of the combination of two drugs was determined by the micro chessboard dilution method. The effects of combined drugs on enhancing the antibacterial activity of different strains were evaluated respectively by calculating the fractional inhibitory concentration index (FICI). The drug-containing serum of levofloxa-cin group, Qiguiyin decoction group, Qiguiyin decoction combined with levofloxacin group and control group was prepared. The antibacterial rate, MIC and MBC of 10% ~ 90% serum against the two strains were determined. Results Combined with Qiguiyin decoction, MIC of levofloxacin against pseudomonas aeruginosa (standard/resistant) decreased significantly, 0. 5 < FICI ^ 1. With the increase of the proportion of serum, the inhibitory rate of 10% ~ 90% drug-containing serum to pseudomonas aeruginosa (standard/resistant) increased gradually.compared with the control group, the inhibitory effect of the Qiguiyin group on bacteria was significantly enhanced. The MIC
4. Effect and mechanism of p-hydroxybenzaldehyde on experimental intestinal fibrosis
Xi LU ; Yi-Han MA ; Bing QIN ; Yu-Hui WANG ; Xiao-Tian XU ; Xiao-Qun DUAN ; Xiao-Qun DUAN
Chinese Pharmacological Bulletin 2023;39(4):685-692
Aim To investigate the effect of p-hydroxybenzaldehyde ( HD) on intestinal fibrosis in mice based on mouse intestinal fibrosis model and in vitro EMT model,and to explore the underlying mechanism Methods HE staining, Masson staining, immunohisto-chemistry ,qPCR, Western blot and other experimental methods were used to verify the effect of HD on intestinal fibrosis in mice and the potential mechanism. Results In vivo experiments showed that compared with the normal group, the DSS-induced intestinal fibrosis model group had shortened colon, increased colon his-topathological score, increased collagen volume fraction, and significantly increased collagen I expression. After treatment with 4, 10, and 25 mg • kg
5.Study on formulation and revision of standard limit for formaldehyde in the "Standards for indoor air quality(GB/T 18883-2022)" in China.
Xiao Yan DONG ; Jiao WANG ; Xian Liang WANG ; Tian Tian LI ; Qin WANG ; Dong Qun XU
Chinese Journal of Preventive Medicine 2023;57(11):1748-1751
Formaldehyde, as an important pollutant in indoor air, has always been of great concern. In the newly issued "Standards for indoor air quality (GB/T 18883-2022)", the standard limit of formaldehyde has been restricted to 0.08 mg/m3. In order to better promote the implementation and application of this new standard, this study reviewed and interpreted the relevant technical content for determining the standard limit, including the indoor concentration and human exposure levels of formaldehyde, the health effects of formaldehyde, and the derivation of safety reference values. It also proposed prospect for the future development and revision of quality standards for formaldehyde in indoor air.
Humans
;
Air Pollution, Indoor
;
Air Pollutants/analysis*
;
Formaldehyde/analysis*
;
China
;
Environmental Pollutants
6.Epidemiological Survey of Hemoglobinopathies Based on Next-Generation Sequencing Platform in Hunan Province, China.
Hui XI ; Qin LIU ; Dong Hua XIE ; Xu ZHOU ; Wang Lan TANG ; De Guo TANG ; Chun Yan ZENG ; Qiong WANG ; Xing Hui NIE ; Jin Ping PENG ; Xiao Ya GAO ; Hong Liang WU ; Hao Qing ZHANG ; Li QIU ; Zong Hui FENG ; Shu Yuan WANG ; Shu Xiang ZHOU ; Jun HE ; Shi Hao ZHOU ; Fa Qun ZHOU ; Jun Qing ZHENG ; Shun Yao WANG ; Shi Ping CHEN ; Zhi Fen ZHENG ; Xiao Yuan MA ; Jun Qun FANG ; Chang Biao LIANG ; Hua WANG
Biomedical and Environmental Sciences 2023;36(2):127-134
OBJECTIVE:
This study was aimed at investigating the carrier rate of, and molecular variation in, α- and β-globin gene mutations in Hunan Province.
METHODS:
We recruited 25,946 individuals attending premarital screening from 42 districts and counties in all 14 cities of Hunan Province. Hematological screening was performed, and molecular parameters were assessed.
RESULTS:
The overall carrier rate of thalassemia was 7.1%, including 4.83% for α-thalassemia, 2.15% for β-thalassemia, and 0.12% for both α- and β-thalassemia. The highest carrier rate of thalassemia was in Yongzhou (14.57%). The most abundant genotype of α-thalassemia and β-thalassemia was -α 3.7/αα (50.23%) and β IVS-II-654/β N (28.23%), respectively. Four α-globin mutations [CD108 (ACC>AAC), CAP +29 (G>C), Hb Agrinio and Hb Cervantes] and six β-globin mutations [CAP +8 (C>T), IVS-II-848 (C>T), -56 (G>C), beta nt-77 (G>C), codon 20/21 (-TGGA) and Hb Knossos] had not previously been identified in China. Furthermore, this study provides the first report of the carrier rates of abnormal hemoglobin variants and α-globin triplication in Hunan Province, which were 0.49% and 1.99%, respectively.
CONCLUSION
Our study demonstrates the high complexity and diversity of thalassemia gene mutations in the Hunan population. The results should facilitate genetic counselling and the prevention of severe thalassemia in this region.
Humans
;
beta-Thalassemia/genetics*
;
alpha-Thalassemia/genetics*
;
Hemoglobinopathies/genetics*
;
China/epidemiology*
;
High-Throughput Nucleotide Sequencing
7.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
8.Study on formulation and revision of standard limit for formaldehyde in the "Standards for indoor air quality(GB/T 18883-2022)" in China.
Xiao Yan DONG ; Jiao WANG ; Xian Liang WANG ; Tian Tian LI ; Qin WANG ; Dong Qun XU
Chinese Journal of Preventive Medicine 2023;57(11):1748-1751
Formaldehyde, as an important pollutant in indoor air, has always been of great concern. In the newly issued "Standards for indoor air quality (GB/T 18883-2022)", the standard limit of formaldehyde has been restricted to 0.08 mg/m3. In order to better promote the implementation and application of this new standard, this study reviewed and interpreted the relevant technical content for determining the standard limit, including the indoor concentration and human exposure levels of formaldehyde, the health effects of formaldehyde, and the derivation of safety reference values. It also proposed prospect for the future development and revision of quality standards for formaldehyde in indoor air.
Humans
;
Air Pollution, Indoor
;
Air Pollutants/analysis*
;
Formaldehyde/analysis*
;
China
;
Environmental Pollutants
9.Effects of GSK3β/eEF2K signaling pathway on pulmonary fibrosis in mice.
Chao-Qun QIN ; Bin HUANG ; Fang YANG ; Chang-Ming WANG ; Ying XIAO ; Yan-Ju MO ; Yi LIAO ; Feng GAO
Chinese Journal of Applied Physiology 2022;38(1):32-36
Objective: To investigate the effects of glycogen synthase kinase-3β (GSK3β)/eukaryotic extension factor kinase 2 (eEF2K) signaling pathway on the process of pulmonary fibrosis through in vivo experiments, and find new ideas for clinical treatment of pulmonary fibrosis. Methods: The pulmonary fibrosis model of C57BL/6 male mice was induced by bleomycin with intratracheal injection at the dose of 2 mg/kg. After 14 days of modeling, animals were divided into model group, negative inhibition group and inhibition group (n=5 for each group), and control group was not processed. The inhibition group was treated with TDZD-8 (4 mg/kg) after modeling, the negative inhibition group was given DMSO solution after modeling, and the samples were collected after 28 days. Hematoxylin-eosin staining method was used to detect lung fibrosis in mice and scored according to Ashcroft scale. Expression levels of GSK3β, p-GSK3β, eEF2K, p-eEF2K (Ser70, Ser392, Ser470), precursor protein of matrix metalloproteinase-2 (pro-MMP-2), matrix metalloproteinase-2 (MMP-2), collagen I (Col I), collagen Ⅲ (Col Ⅲ) and α-smooth muscle actin (α-SMA) were detected by Western blot. Results: Compared with control group, the fibrosis score was up-regulated, the expression levels of GSK3β, p-GSK3β, p-eEF2K (Ser70, Ser392, Ser470), pro-MMP-2, MMP-2, Col I, Col Ⅲ and α-SMA were increased, while that of eEF2K was decreased in model group (P<0.05). Compared with model group, the fibrosis score, expression levels of GSK3β, p-GSK3β, p-eEF2K (Ser70, Ser392, Ser470), pro-MMP-2, MMP-2, Col I, Col Ⅲ and α-SMA were decreased, but the expression level of eEF2K was increased in inhibition group (P<0.05). Conclusion: GSK3β can activate eEF2K by phosphorylation at the sites of Ser70, Ser392 and Ser470, increase the contents of fibrosis indicators, promote the formation of pulmonary fibrosis, and aggravate lung tissue lesions.
Animals
;
Collagen
;
Collagen Type I
;
Elongation Factor 2 Kinase/metabolism*
;
Eukaryota/metabolism*
;
Fibrosis
;
Glycogen Synthase Kinase 3 beta
;
Male
;
Matrix Metalloproteinase 2/metabolism*
;
Mice
;
Mice, Inbred C57BL
;
Pulmonary Fibrosis/chemically induced*
;
Signal Transduction
10.Incidence and risk factors of ischemic stroke in patients with type 2 diabetes among urban workers in Beijing, China.
Jun Hui WU ; Yi Qun WU ; Yao WU ; Zi Jing WANG ; Tao WU ; Xue Ying QIN ; Meng Ying WANG ; Xiao Wen WANG ; Jia Ting WANG ; Yong Hua HU
Journal of Peking University(Health Sciences) 2022;54(2):249-254
OBJECTIVE:
To explore the incidence of ischemic stroke after the onset of type 2 diabetes, and further analyze the risk factors, so as to provide a basis for further research.
METHODS:
The data were obtained from the database of the Beijing Urban Employee Basic Medical Insurance Database. The study used a prospective design to describe the incidence of ischemic stroke in patients with type 2 diabetes. In our study, these patients were followed up for seven years. Multivariate Logistic regression models were used to analyze the risk factors of ischemic stroke in patients with type 2 diabetes.
RESULTS:
A total of 185 813 newly diagnosed type 2 diabetes patients were enrolled, with an average age of (58.5±13.2) years, and 49.0% of them were males. A total of 10 393 patients with newly diagnosed ischemic stroke occurred in 7 years, with a cumulative incidence of 5.6% and an incidence density of 8.1/1 000 person-years. Ischemic stroke occurred in all age groups in patients with type 2 diabetes. The cumulative incidence was 1.5% (95%CI: 1.3%-1.6%) in group ≤44 years old, 3.6% (95%CI: 3.4%-3.7%) in group 45-54 years old, 5.4% (95%CI: 5.2%-5.5%) in group 55-64 years old, and 9.2% (95%CI: 9.0%-9.4%) in group ≥65 years old, and the cumulative incidence increased with age (P < 0.05). Cumulative incidence rate of the males (6.8%, 95%CI: 6.7%-7.0%) was higher than the females (4.4%, 95%CI: 4.3%-4.6%). Among the patients < 80 years old, the cumulative incidence rate of the males was higher than that of the females in all the age groups. In the patients ≥80 years of age, the cumulative incidence was higher in the females (9.2%) than in the males (7.9%). Further analysis revealed that complications, such as coronary heart disease (OR=3.18, 95%CI: 2.72-3.72), heart failure (OR=1.53, 95%CI: 1.32-1.79) and kidney failure (OR=1.45, 95%CI: 1.20-1.75) were associated with ischemic stroke in the patients with type 2 diabetes.
CONCLUSION
The incidence level of ischemic stroke in patients with type 2 diabetes is high. It is necessary to strengthen the management of risk factors in elderly patients, screen the complications of type 2 diabetes as early as possible, and take active preventive and control measures.
Adult
;
Aged
;
Aged, 80 and over
;
Beijing/epidemiology*
;
Diabetes Mellitus, Type 2/epidemiology*
;
Female
;
Humans
;
Incidence
;
Ischemic Stroke
;
Male
;
Middle Aged
;
Prospective Studies
;
Risk Factors
;
Stroke/etiology*

Result Analysis
Print
Save
E-mail