1.Drug Delivery Systems for Pancreatic Cancers Treatment
Wan-Rui SHI ; Li-Gang CUI ; Xiao-Long LIANG
Progress in Biochemistry and Biophysics 2025;52(7):1745-1756
Pancreatic cancers (PCs) is a common malignant tumor with poor prognosis in the digestive system. Its main treatment methods include surgery, radiotherapy, chemotherapy, and targeted therapy. The early diagnosis rate of hidden onset of PCs is low, and most patients have already lost the opportunity to undergo surgery when diagnosed with PCs. Chemotherapy is still the main treatment for advanced PCs, but the use of chemotherapy drugs in PCs can easily lead to drug resistance. The most significant feature that distinguishes PCs from other tumors is its rich and dense matrix, which not only hinders drug penetration but also impedes the infiltration of immune cells. The above reasons have led to a very low survival rate of PCs patients. Therefore, drug delivery systems are very important in the diagnosis and treatment of PCs. They can improve drug delivery, enhance biological barrier penetration, reduce side effects, and combine multiple treatment methods. Therefore, the treatment prospects of PCs are very broad. Currently, drug delivery systems widely applied in PCs primarily include nanodrug delivery systems, tumor microenvironment-targeted drug delivery system, immunotherapy drug delivery system, gene therapy drug delivery system, and combination therapy drug delivery system that synergize multiple therapeutic modalities. Emerging drug delivery systems (DDSs) have revolutionized PCs treatment by addressing these challenges through multiple mechanisms. Nanoformulations improve drug solubility, prolong circulation time, and reduce systemic toxicity via passive/active targeting. Smart DDSs responsive to PCs-specific stimuli enable extracellular matrix degradation, tumor-associated fibroblasts reprogramming, and vascular normalization to enhance drug accessibility. Last but not least, carrier systems loaded with myeloid-derived suppressor cell inhibitors or T cell activators can reverse immunosuppression and potentiate immunotherapy efficacy. Advanced platforms co-deliver chemotherapeutics with immunomodulators, gene-editing tools, or sonodynamic agents to achieve synergistic antitumor effects. These platforms aim to address critical challenges in PCs treatment, such as enhancing drug bioavailability, overcoming stromal barriers, reprogramming immunosuppressive niches, and achieving multi-mechanistic antitumor effects. This article provides a systematic summary and prospective analysis of the current development status, latest cutting-edge advances, opportunities, and challenges of the above-mentioned drug delivery systems in the field of PCs therapy.
2.Influencing factors and clinical treatment of severe complications after unilateral pneumonectomy in treating tuberculous destroyed lung
Xiao LI ; Ning WANG ; Lei BAO ; Zhiqiang WU ; Gang LI ; Cong CAI ; Yijie SONG ; Dan LI ; Banggui WU ; Liangshuang JIANG ; Xiaojun YAO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(05):626-633
Objective To evaluate the surgical efficacy of unilateral pneumonectomy for the treatment of tuberculous destroyed lung, analyze the causes of severe postoperative complications, and explore clinical management strategies. Methods A retrospective analysis was conducted on the clinical data of patients with tuberculous destroyed lung who underwent unilateral pneumonectomy at the Public Health Clinical Center of Chengdu from 2017 to 2023. Postoperative severe complications were statistically analyzed. Patients were divided into a non-severe complication group and a severe-complication group, and the causes, management, and outcomes of complications were analyzed. Results A total of 134 patients were included, comprising 69 males and 65 females, with a mean age of 17-73 (40.43±12.69) years. There were 93 patients undergoing left pneumonectomy and 41 patients undergoing right pneumonectomy. Preoperative sputum smear was positive in 35 patients, all of which converted to negative postoperatively. There were 58 patients with hemoptysis preoperatively, and none experienced hemoptysis postoperatively. Postoperative incisional infection occurred in 8 (5.97%) patients, and postoperative pulmonary infection in 26 (19.40%) patients. Severe postoperative complications occurred in 17 (12.69%) patients, including empyema in 9 (6.72%) patients, bronchopleural fistula with empyema in 1 (0.75%) patient, severe pneumonia in 3 (2.24%) patients, postpneumonectomy syndrome in 1 (0.75%) patient, chylothorax in 1 (0.75%) patient, ketoacidosis in 1 (0.75%) patient, and heart failure with severe pneumonia in 1 (0.75%) patient. Perioperative mortality occurred in 2 (1.49%) patients, both of whom underwent right pneumonectomy. Multivariate logistic regression analysis revealed that a history of ipsilateral thoracic surgery, concomitant Aspergillus infection, and greater blood loss were independent risk factors for severe complications following unilateral pneumonectomy for tuberculous destroyed lung (P<0.05). Conclusion Unilateral pneumonectomy for patients with tuberculous destroyed lung can significantly improve the clinical cure rate, sputum conversion rate, and hemoptysis cessation rate. However, there is a certain risk of severe perioperative complications and mortality, requiring thorough perioperative management and appropriate management of postoperative complications.
3.Determination of biological activity of teduglutide by a homogeneous time-resolved fluorescence method
Xiao-ming ZHANG ; Ran MA ; Li-jing LÜ ; Lü-yin WANG ; Ping LÜ ; Cheng-gang LIANG ; Jing LI
Acta Pharmaceutica Sinica 2025;60(1):211-217
In this study, we constructed a GLP-2R-HEK293 cell line and established a method for the determination of the
4.Molecular mechanism of Shenling Baizhu powder in treatment of cancer cachexia based on network pharmacology
Gang KE ; Qingke DONG ; Shirong XIAO ; Qian GONG ; Rong LI ; Daijie WANG
Journal of Pharmaceutical Practice and Service 2025;43(5):242-250
Objective To analyze the pharmacological mechanism of Shenling Baizhu powder in the treatment of cancer cachexia based on the network pharmacological method and provide a reference for the clinical application of classical traditional Chinese medicine(TCM) prescriptions. Methods Through TCMSP and BATMAN-TCM databases, the main chemical components and their targets of the TCM prescription of Shenling Baizhu powder were obtained, and the active components of the TCM were screened according to ADME. The main targets of cancer cachexia were obtained through OMIM, Genecards, Disgenet and DRUGBANK databases, and protein interaction analysis was conducted using String platform to build a PPI network. The “drug-active ingredient-target” network of Shenling Baizhu powder was constructed by Cytoscape 3.7.2 software, and then the biological processes and pathways involved were analyzed by using Metascape platform. Finally, molecular docking verification was conducted by Discovery Studio. Results The core active ingredients of Shenling Baizhu powder in the treatment of cancer cachexia were quercetin, kaempferol, pyrolignous acid, stigmasterol, luteolin, β-sitosterol, etc. The core targets were AKT1, TP53, TNF, IL-6, MAPK3, CASP3, JUN, CTNNB1, HIF1A, EGFR, etc. The molecular docking test also showed that the top 10 active ingredients, such as pyrolignous acid, stigmasterol and β-sitosterol, had good binding activities with most of the target sites. The biological pathway of Shenling Baizhu powder in treating cancer cachexia wss mainly to regulate tumor related pathway, metabolism related pathway, inflammatory factors and appetite related pathway. Conclusion This study preliminarily revealed the mechanism of action of Shenling Baizhu powder in treating cancer cachexia with multi components, multi targets and multi pathways, which provided a basis for the clinical development and utilization of Shenling Baizhu powder.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.A reporter gene assays for bioactivity determination of human chorinonic gonadotropin
Ying HUANG ; Xiao-ming ZHANG ; He-yang LI ; Lü-yin WANG ; Hui ZHANG ; Ping LÜ ; Jing LI ; Xiang-dong GAO ; Cheng-gang LIANG
Acta Pharmaceutica Sinica 2024;59(2):432-438
This study constructed a LHCGR-CRE-luc-HEK293 transgenic cell line according to the activation of the cAMP signaling pathway after recombinant human chorionic gonadotropin binding to the receptor. The biological activity of recombinant human chorionic gonadotropin was assayed using a luciferase assay system. The relative potency of the samples was calculated using four-parameter model. And the method conditions were optimized to validate the specificity, relative accuracy, precision and linearity of the method. The results showed that there was a quantitative potency relationship of human chorinonic gonadotropin (hCG) in the method and it was in accordance with the four-parameter curve. After optimization, the conditions were determined as hCG dilution concentration of 2.5 μg·mL-1, dilution ratio of 1∶4, cell number of 10 000-15 000 cells/well, and induction time of 6 h. The method had good specificity, relative accuracy with relative bias ranging from -8.9% to 3.4%, linear regression equation correlation coefficient of 0.996, intermediate precision geometric coefficient of variation ranging from 3.3% to 15.0%, and linearity range of 50% to 200%. This study successfully established and validated a reporter gene method to detect hCG biological activity, which can be used for hCG biological activity assay and quality control.

Result Analysis
Print
Save
E-mail