1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Development of a High-throughput Sequencing Platform for Detection of Viral Encephalitis Pathogens Based on Amplicon Sequencing
Li Ya ZHANG ; Zhe Wen SU ; Chen Rui WANG ; Yan LI ; Feng Jun ZHANG ; Hui Sheng LIU ; He Dan HU ; Xiao Chong XU ; Yu Jia YIN ; Kai Qi YIN ; Ying HE ; Fan LI ; Hong Shi FU ; Kai NIE ; Dong Guo LIANG ; Yong TAO ; Tao Song XU ; Feng Chao MA ; Yu Huan WANG
Biomedical and Environmental Sciences 2024;37(3):294-302
Objective Viral encephalitis is an infectious disease severely affecting human health.It is caused by a wide variety of viral pathogens,including herpes viruses,flaviviruses,enteroviruses,and other viruses.The laboratory diagnosis of viral encephalitis is a worldwide challenge.Recently,high-throughput sequencing technology has provided new tools for diagnosing central nervous system infections.Thus,In this study,we established a multipathogen detection platform for viral encephalitis based on amplicon sequencing. Methods We designed nine pairs of specific polymerase chain reaction(PCR)primers for the 12 viruses by reviewing the relevant literature.The detection ability of the primers was verified by software simulation and the detection of known positive samples.Amplicon sequencing was used to validate the samples,and consistency was compared with Sanger sequencing. Results The results showed that the target sequences of various pathogens were obtained at a coverage depth level greater than 20×,and the sequence lengths were consistent with the sizes of the predicted amplicons.The sequences were verified using the National Center for Biotechnology Information BLAST,and all results were consistent with the results of Sanger sequencing. Conclusion Amplicon-based high-throughput sequencing technology is feasible as a supplementary method for the pathogenic detection of viral encephalitis.It is also a useful tool for the high-volume screening of clinical samples.
7.The 504th case: Multiple lymph node enlargement, renal insufficiency, blindness, and white matter lesions of the brain
Chong WEI ; Zhe ZHUANG ; Yunlong LI ; Xiaoxiao SHI ; Yubing WEN ; Wei CAO ; Siyuan FAN ; Xiao ZHANG ; Yan ZHANG ; Wei ZHANG ; Daobin ZHOU
Chinese Journal of Internal Medicine 2024;63(3):316-320
A 65-year-old male patient was admitted for recurrent lymph node enlargement for 5 years and elevated creatinine for 6 months. This patient was diagnosed with angioimmunoblastic T-cell lymphoma 5 years ago and underwent multiple lines of anti-tumor therapy, including cytotoxic chemotherapy; epigenetic modifying drugs such as chidamide and azacitidine; the immunomodulator lenalidomide; and targeted therapy such as rituximab, a CD20-targeting antibody, and brentuximab vedotin, which targets CD30. Although the tumor was considered stable, multiple virus activation (including BK virus, JC virus, and cytomegalovirus) accompanied by the corresponding organ damage (polyomavirus nephropathy, cytomegalovirus retinitis, and progressive multifocal leukoencephalopathy) occurred during anti-tumor treatment. Anti-tumor therapy was suspended and ganciclovir was used. The serum viral load decreased and organ functions were stabilized. The purpose of this report was to raise clinicians′ awareness of opportunistic virus reactivation during anti-tumor treatment.
8.Spinal infection caused by Prevotella intermedia:analysis of misdiagnosis and literature review
Chong WANG ; Yi YANG ; Dai-Jun LI ; Hua-Hua FAN ; Jia-Qiang YAN ; Rui-Chun WANG ; Xiao-Jun CAI ; Yu-Qiang CAI ; Hou-Jie SUN
Chinese Journal of Infection Control 2024;23(1):86-94
Objective To explore the clinical characteristics and treatment scheme of patients with spinal infection caused by Prevotella intermedia(P.intermedia).Methods Clinical diagnosis and treatment processes of a patient with spinal infection caused by P.intermedia admitted to the spinal surgery department of a hospital were summa-rized,and relevant literature was retrieved from database for reviewing.Results The patient,a 50 year old male,was admitted to the hospital due to"lumbago pain complicated with pain in double lower extremities for 2 months".The lesion tissue was taken for metagenomic next-generation sequencing(mNGS)detection,which detected P.in-termedia,and the patient was diagnosed with P.intermedia spondylitis.After treatments with open lesion clea-rance,tube rinsing+autologous bone transplantation fusion internal fixation,intravenous drip of ceftriaxone sodium and metronidazole,as well as metronidazole rinsing,infection was under control.A total of 16 available papers were retrieved,together with this case,a total of 17 patients were included,with 7 males and 10 females.The main risk factors were diabetes and history of corticosteroid use(35.3%).The most common invasion sites were lumbar ver-tebra(n=12)and thoracic vertebra(n=6).13 cases were positive for pathogen culture,3 cases were positive for molecular detection,and 1 case was positive for staining microscopy.17 patients received anti-anaerobic bacteria treatment,with 14 cases receiving combined surgical treatment.One case died,with a mortality of 5.9%;5 cases had partial neurological impairment,with a disability rate of 29.4%.The survival rate of patients who received treatment of anti-anaerobic bacteria combined with surgery was 92.8%,3 patients only with anti-anaerobic bacteria treatment but without surgery were all cured.Conclusion P.intermedia is an opportunistic pathogeanic bacteria which often causes infection in immunocomprised individuals and is prone to be misdiagnosed.It is recommended to perform mNGS detection to identify the pathogen as early as possible and seize the opportunity for treatment to reduce mortality.
9.Diagnostic value of cross-primer isothermal amplification technology in tuberculosis and its related influencing factors
YU Huang ; LIU Chong ; OUYANG Fan-xian ; CHEN Zhuo-lin ; CHEN Lin ; CHEN Xiao-juan ; XU Yu-ni ; CHEN Shao-wen
China Tropical Medicine 2023;23(3):240-
Abstract: Objective To analyze the value and influencing factors of cross-primer isothermal amplification technology(CPA) in clinical screening and diagnosis of tuberculosis (TB). Methods We collected 543 inpatients in the Second Affiliated Hospital of Hainan Medical College from January 1, 2018 to December 31, 2021, including 179 patients with tuberculosis, 187 patients with pneumonia and 177 patients with other diseases. The patients' sputum, alveolar lavage fluid, pleural effusion and midstream urine were detected by CPA, smear microscopy, culture method and gene detection. The value of CPA detection in the diagnosis of tuberculosis and its influencing factors were evaluated. Statistical analysis was performed using SPSS 26.0. Results The total positive rate of CPA was 14.4% (78/543), and the positive rate of sputum samples accounted for 29.1% (39/134). Among the 78 cases of CPA positive patients, the tuberculosis group accounted for 69.2% (54/78), followed by pneumonia group 21.8% (17/78), and other diseases group accounted for 9.0% (7/78). Taking CPA test as the reference method, the "sensitivity" of smear microscopy was lower than that of genetic testing and culture, while the "specificity" was higher than that of culture and gene testing, and the "missed diagnosis rate" of smear microscopy was higher than that of genetic testing and culture. CPA test positive was related to gender, ESR and pneumonia. There is a good agreement between CPA test and culture method and gene test (Kappa>0.9), and a moderate agreement between CPA test and smear microscopy (Kappa=0.616). Conclusions Sputum specimen is the best choice for CPA detection, while the value of pleural effusion detection is relatively limited. Sputum, alveolar lavage fluid and midcourse urine can be used as clinical specimens for screening and diagnosis of "tuberculosis group and other disease group", while sputum can be used for screening and diagnosis of "tuberculosis group and pneumonia group". Gender, ESR and pneumonia are the influencing factors of CPA positive patients. Therefore, CPA testing is worthy of clinical promotion, but more clinical research data are needed.
10.Intelligent fault diagnosis expert system for multi-parameter monitor based on fault tree.
Liping FAN ; Lang LANG ; Jingjing XIAO ; Shihui ZHANG ; Yinbao CHONG ; Simin LYU
Journal of Biomedical Engineering 2022;39(3):586-595
Aiming at the dilemma of expensive and difficult maintenance, lack of technical data and insufficient maintenance force for modern medical equipment, an intelligent fault diagnosis expert system of multi-parameter monitor based on fault tree was proposed in this study. Firstly, the fault tree of multi-parameter monitor was established and analyzed qualitatively and quantitatively, then based on the analysis results of fault tree, the expert system knowledge base and inference engine were constructed and the overall framework of the system was determined, finally the intelligent fault diagnosis expert system for multi-parameter monitor was developed by using the page hypertext preprocessor (PHP) language, with an accuracy rate of 80% in fault diagnosis. The results showed that technology fusion on the basis of fault tree and expert system can effectively realize intelligent fault diagnosis of multi-parameter monitors and provide troubleshooting suggestions, which can not only provide experience accumulation for fault diagnosis of multi-parameter monitors, but also provide a new idea and technical support for fault diagnosis of medical equipment.
Expert Systems
;
Monitoring, Physiologic

Result Analysis
Print
Save
E-mail