1.Clinical Characteristics and Influencing Factors of Rheumatoid Arthritis in Patients with Cold Dampness Obstruction Syndrome
Yanyu CHEN ; Yanqi LI ; Longxiao LIU ; Liubo ZHANG ; Tianyi LAN ; Nan ZHANG ; Cheng XIAO ; Yuan XU ; Qingwen TAO
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(3):140-146
ObjectiveTo study the clinical characteristics and influencing factors of rheumatoid arthritis (RA) in the patients with cold dampness obstruction syndrome. MethodsThe RA patients treated in the Department of Traditional Chinese Medicine and Rheumatology of the China-Japan Friendship Hospital from August 2022 to June 2024 were selected. The demographic information, clinical data, laboratory test results, and traditional Chinese medicine (TCM) symptom information were collected for syndrome differentiation, on the basis of which the characteristics and influencing factors of cold dampness obstruction syndrome were analyzed. ResultsA total of 258 RA patients were selected in this study, including 88 (34.1%) patients with cold dampness obstruction syndrome, 53 (20.5%) patients with dampness and heat obstruction syndrome, 31 (12.0%) patients with wind dampness obstruction syndrome, 29 (11.2%) patients with liver-kidney deficiency syndrome, 19 (7.4%) patients with Qi-blood deficiency syndrome, 14 (5.4%) patients with phlegm-stasis obstruction syndrome, 15 (5.8%) patients with stasis obstructing collateral syndrome and 9 (3.5%) patients with Qi-Yin deficiency syndrome. The patients were assigned into two groups of cold dampness obstruction syndrome and other syndromes. The group of cold dampness obstruction syndrome had lower joint fever, 28-tender joint count (TJC28), and 28-joint disease activity score (DAS28)-C-reactive protein (CRP) and higher central sensitization, cold feeling of joints, fear of wind and cold, cold limbs, and abdominal distention than the group of other syndromes (P<0.05). The binary logistic regression analysis showed that central sensitization (OR 5.749, 95%CI 2.116-15.616, P<0.001) and DAS28-CRP (OR 0.600, 95% CI 0.418-0.862, P=0.006) were the independent factors influencing cold dampness obstruction syndrome in RA. ConclusionCold dampness obstruction syndrome is a common syndrome in RA patients. It is associated with central sensitization, cold feeling of joints, abdominal distension and may be a clinical syndrome associated with central sensitization.
2.Applications of Vaterite in Drug Loading and Controlled Release
Xiao-Hui SONG ; Ming-Yu PAN ; Jian-Feng XU ; Zheng-Yu HUANG ; Qing PAN ; Qing-Ning LI
Progress in Biochemistry and Biophysics 2025;52(1):162-181
Currently, the drug delivery system (DDS) based on nanomaterials has become a hot interdisciplinary research topic. One of the core issues is drug loading and controlled release, in which the key lever is carriers. Vaterite, as an inorganic porous nano-material, is one metastable structure of calcium carbonate, full of micro or nano porous. Recently, vaterite has attracted more and more attention, due to its significant advantages, such as rich resources, easy preparations, low cost, simple loading procedures, good biocompatibility and many other good points. Vaterite, gained from suitable preparation strategies, can not only possess the good drug carrying performance, like high loading capacity and stable loading efficiency, but also improve the drug release ability, showing the better drug delivery effects, such as targeting release, pH sensitive release, photothermal controlled release, magnetic assistant release, optothermal controlled release. At the same time, the vaterite carriers, with good safety itself, can protect proteins, enzymes, or other drugs from degradation or inactivation, help imaging or visualization with loading fluorescent drugs in vitro and in vivo, and play synergistic effects with other therapy approaches, like photodynamic therapy, sonodynamic therapy, and thermochemotherapy. Latterly, some renewed reports in drug loading and controlled release have led to their widespread applications in diverse fields, from cell level to clinical studies. This review introduces the basic characteristics of vaterite and briefly summarizes its research history, followed by synthesis strategies. We subsequently highlight recent developments in drug loading and controlled release, with an emphasis on the advantages, quantity capacity, and comparations. Furthermore, new opportunities for using vaterite in cell level and animal level are detailed. Finally, the possible problems and development trends are discussed.
3.Progress on antisense oligonucleotide in the field of antibacterial therapy
Jia LI ; Xiao-lu HAN ; Shi-yu SONG ; Jin-tao LIN ; Zhi-qiang TANG ; Zeng-ming WANG ; Liang XU ; Ai-ping ZHENG
Acta Pharmaceutica Sinica 2025;60(2):337-347
With the widespread use of antibiotics, drug-resistant bacterial infections have become a significant threat to human health. Finding new antibacterial strategies that can effectively control drug-resistant bacterial infections has become an urgent task. Unlike small molecule drugs that target bacterial proteins, antisense oligonucleotide (ASO) can target genes related to bacterial resistance, pathogenesis, growth, reproduction and biofilm formation. By regulating the expression of these genes, ASO can inhibit or kill bacteria, providing a novel approach for the development of antibacterial drugs. To overcome the challenge of delivering antisense oligonucleotide into bacterial cells, various drug delivery systems have been applied in this field, including cell-penetrating peptides, lipid nanoparticles and inorganic nanoparticles, which have injected new momentum into the development of antisense oligonucleotide in the antibacterial realm. This review summarizes the current development of small nucleic acid drugs, the antibacterial mechanisms, targets, sequences and delivery vectors of antisense oligonucleotide, providing a reference for the research and development of antisense oligonucleotide in the treatment of bacterial infections.
4.A Case Report of Pachydermoperiostosis by Multidisciplinary Diagnosis and Treatment
Jie ZHANG ; Yan ZHANG ; Li HUO ; Ke LYU ; Tao WANG ; Ze'nan XIA ; Xiao LONG ; Kexin XU ; Nan WU ; Bo YANG ; Weibo XIA ; Rongrong HU ; Limeng CHEN ; Ji LI ; Xia HONG ; Yan ZHANG ; Yagang ZUO
JOURNAL OF RARE DISEASES 2025;4(1):75-82
A 20-year-old male patient presented to the Department of Dermatology of Peking Union Medical College Hospital with complaints of an 8-year history of facial scarring, swelling of the lower limbs, and a 4-year history of scalp thickening. Physical examination showed thickening furrowing wrinkling of the skin on the face and behind the ears, ciliary body hirsutism, blepharoptosis, and cutis verticis gyrate. Both lower limbs were swollen, especially the knees and ankles. The skin of the palms and soles of the feet was keratinized and thickened. Laboratory examination using bone and joint X-ray showed periostosis of the proximal middle phalanges and metacarpals of both hands, distal ulna and radius, tibia and fibula, distal femurs, and metatarsals.Genetic testing revealed two variants in
5.Application of blood conservation measures with different red blood cell transfusion volumes in obstetrics and their impact on postpartum outcomes
Huimin DENG ; Fengcheng XU ; Meiting LI ; Lan HU ; Xiao WANG ; Shiyu WANG ; Xiaofei YUAN ; Jun ZHENG ; Zehua DONG ; Yuanshan LU ; Shaoheng CHEN
Chinese Journal of Blood Transfusion 2025;38(5):691-698
Objective: To evaluate the application of blood conservation measures in obstetric patients with different red blood cell transfusion volumes and to assess the impact of different transfusion volumes on postpartum outcomes. Methods: A retrospective investigation was conducted on 448 obstetric patients who received blood transfusions at the Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine from January 2016 to December 2022. Patients were divided into four groups (1-2 units group, 3-4 units group, 5-6 units group, and >6 units group) based on the volumes of red blood cells (RBCs) transfused during and within 7 days after delivery. The maternal physiological indicators, pre- and postpartum laboratory test indicators, obstetric complications, application of blood conservation measures, use of blood products, and postpartum outcomes were reviewed. The clinical characteristics, application of blood conservation measures, and their impact on postpartum outcomes were compared among different transfusion groups. Results: There were statistically significant differences in the multivariate logistic analysis of history of previous cesarean section (OR=1.781), eclampsia/pre-eclampsia/(OR=1.972) and postpartum blood loss>1 000 mL(OR=1.699)(P<0.05) among different transfusion groups. In terms of blood conservation measures, the more RBCs transfused, the higher the rate of mothers receiving blood conservation measures such as balloon occlusion, arterial ligation, autologous blood transfusion with a cell saver, and hysterectomy. With the increase in the volume of RBCs transfusion, the demand for fresh frozen plasma(FFP), cryoprecipitate, and platelet transfusions also increased. The hospitalization days for the four groups of parturients were 6.0 (4.0-9.0), 7.5 (5.0-14.8), 7.0 (4.5-13.0) and 11.0 (9.0-20.5), respectively (P<0.05) and the rates of ICU transfer were 2.0% (5/250), 9.4% (12/128),18.2% (6/33) and 51.4% (19/37), respectively (P<0.05). Both increased significantly with the increase in the volume of RBCs transfusion, and the differences between groups were statistically significant. Conclusion: Parturients who received higher volume of RBCs had multiple risks factors for bleeding before childbirth, had higher postpartum blood loss, and had a higher rate of application of various blood conservation measures. In addition, an increase in the volume of RBCs transfusion may have adverse effects on postpartum recovery.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Isorhamnetin Alleviates Inflammation-Induced Crosstalk between Kynurenine Pathway and Gut Microbiota in Depressed Mice
Mengjie XU ; Wei HE ; Ke YAN ; Xinru GAO ; Jun LI ; Dongyue XU ; Jiao XIAO ; Tingxu YAN
Biomolecules & Therapeutics 2025;33(2):297-310
Depression is a widespread psychiatric disorder with complex pathogenesis and unsatisfactory therapeutic effects. As a native flavonoid, Isorhamnetin (ISO) has been deemed to exert neuroprotective effects by antioxidation and regulation of immunity. However, no reports of anti-depressed effect of ISO have yet been found. The present study was conducted to clarify the mechanism basis of anti-depressed effect of ISO utilizing behavioral, biochemical, molecular approaches in vitro and in vivo and bio-informatics analysis. The effects of ISO on depressed mice was investigated through the SPT and FST, and the lesions were examined by H&E staining. Besides, the inflammatory factor and indicator in kynurenine pathway were assessed through detection kits, and the microbiota were checked by 16sRNA. Molecular docking study was performed to investigate the target of ISO. Additionally, Western blot was used to test the activation of PI3K/AKT signaling pathway. The results indicated that ISO could enhance the sugar water preference of mice in SPT and reduce immobility time in FST. Further more, ISO suppressed peripheral and central inflammation, regulated the changes in kynurenine pathway and gut microbiota, inhibited activation of PI3K/AKT pathway, and presented good binding patterns with target proteins on PI3K/AKT signaling pathway. Collectively, these findings demonstrate that ISO alleviated depression-like behaviour by normalizing inflammation-induced dysregulation of the crosstalk between KP and gut microbiota disorder through regulated PI3K/AKT/NF-κB pathway.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Isorhamnetin Alleviates Inflammation-Induced Crosstalk between Kynurenine Pathway and Gut Microbiota in Depressed Mice
Mengjie XU ; Wei HE ; Ke YAN ; Xinru GAO ; Jun LI ; Dongyue XU ; Jiao XIAO ; Tingxu YAN
Biomolecules & Therapeutics 2025;33(2):297-310
Depression is a widespread psychiatric disorder with complex pathogenesis and unsatisfactory therapeutic effects. As a native flavonoid, Isorhamnetin (ISO) has been deemed to exert neuroprotective effects by antioxidation and regulation of immunity. However, no reports of anti-depressed effect of ISO have yet been found. The present study was conducted to clarify the mechanism basis of anti-depressed effect of ISO utilizing behavioral, biochemical, molecular approaches in vitro and in vivo and bio-informatics analysis. The effects of ISO on depressed mice was investigated through the SPT and FST, and the lesions were examined by H&E staining. Besides, the inflammatory factor and indicator in kynurenine pathway were assessed through detection kits, and the microbiota were checked by 16sRNA. Molecular docking study was performed to investigate the target of ISO. Additionally, Western blot was used to test the activation of PI3K/AKT signaling pathway. The results indicated that ISO could enhance the sugar water preference of mice in SPT and reduce immobility time in FST. Further more, ISO suppressed peripheral and central inflammation, regulated the changes in kynurenine pathway and gut microbiota, inhibited activation of PI3K/AKT pathway, and presented good binding patterns with target proteins on PI3K/AKT signaling pathway. Collectively, these findings demonstrate that ISO alleviated depression-like behaviour by normalizing inflammation-induced dysregulation of the crosstalk between KP and gut microbiota disorder through regulated PI3K/AKT/NF-κB pathway.

Result Analysis
Print
Save
E-mail