1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Effects of total flavonoids of Oxytropis falcata Bunge on CCl4-induced liver fibrosis in rats
Tian-Yan YANG ; Xin-Huan MA ; Zhi-Wei XU ; Rong-Kun LI ; Fang-Xiong MA ; Bao-Feng HE ; Liang CHEN ; Xiao-Qing CHEN ; Jun ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(14):2073-2077
Objective To investigate the effects of total flavones from Oxytropis falcata Bunge on hepatic fibrosis(HF)induced by carbon tetrachloride and liver transforming growth factor(TGF-β)/Smad signaling pathway.Methods Forty-eight male rats were randomly divided into normal group(intraperitoneal injection of peanut oil,intragastric administration of 0.9%NaCl),model group(intraperitoneal injection of 40%CC14 peanut oil solution induced HF model,intragastric administration of 0.9%NaCl),positive control group(modeling,intragastric administration of 0.2 mg·kg-1 of colchicine),experimental-L,-M,-H groups(modeling,intragastric administration of 100,200 and 400 mg·kg-1 of total flavonoid extract of Oxytropis falcata Bunge),8 individuals in each group,for 4 consecutive weeks.The histopathological changes were observed by hematoxylin-eosin and Masson staining.Serum liver function and liver fibrosis were measured;erum inflammatory factors were detected;fluorescence quantitative polymerase chain reaction(RT-qPCR)was used to determine gene expression in liver.Results The pathological injury of liver tissue in the model group was serious,and a large number of inflammatory factors and collagen fibers were accumulated,while the rest of the treatment groups had different degrees of remission.In normal group,model group,positive control group,experimental-L,-M,-H groups,glutamic-pyruvic transaminase levels were(49.28±12.44),(5 885.42±948.37),(4 454.60±489.27),(4 650.47±843.53),(3 761.75±887.30)and(3 544.90±1 066.75)μg·L-1;glutamic-oxaloacetic transaminase levels were(186.90±46.89),(5 936.23±793.81),(3 971.37±780.28),(4 360.30±863.35),(3 943.10±439.47)and(3 971.38±631.08)μg·L-1;hyaluronic acid levels were(45.08±17.16),(104.32±36.06),(66.83±20.09),(70.30±21.07),(60.00±9.68)and(59.02±10.73)μg·L-1;laminin levels were(23.13±3.89),(60.85±13.66),(35.67±9.92),(39.98±9.39),(36.55±12.21)and(34.68±24.83)μg·L-1;type Ⅲ procollagen level were(24.98±5.34),(82.58±30.14),(40.70±16.14),(51.08±23.21),(43.60±12.48)and(44.20±11.66)p±g·L-1;interleukin(IL)-1β levels were(37.63±1.24),(46.10±3.23),(39.22±2.36),(41.33±0.93),(40.25±2.04)and(39.18±2.23)pg·mL-1;tumor necrosis factor-α levels were(314.58±20.56),(383.71±16.97),(349.00±7.93),(348.88±25.11),(325.75±27.84)and(335.07±21.33)pg·mL-1;TGF-β1 mRNA expression of relative quantity respectively were 1.00±0.00,60.99±15.70,9.61±1.59,7.37±1.09,6.41±0.64,6.87±1.09;Smad7 mRNA relative expression were 1.00±0.00,0.34±0.05,0.21±0.03,0.35±0.02,0.38±0.02,0.42±0.03.The above indexes in the model group were compared with the normal group,and the above indexes in the experimental-M,-H groups were compared with the model group,and the differences were statistically significant(P<0.05,P<0.01,P<0.001).Conclusion Total flavonoids of Oxytropis falcata Bunge have protective effects on CC14-induced liver fibrosis in rats,and the mechanism may be related to the regulation of TGF-β/Smad pathway.
7.Investigation and analysis of the current status of transjugular intrahepatic portosystemic shunt treatment for portal hypertension in China
Haozhuo GUO ; Meng NIU ; Haibo SHAO ; Xinwei HAN ; Jianbo ZHAO ; Junhui SUN ; Zhuting FANG ; Bin XIONG ; Xiaoli ZHU ; Weixin REN ; Min YUAN ; Shiping YU ; Weifu LYU ; Xueqiang ZHANG ; Chunqing ZHANG ; Lei LI ; Xuefeng LUO ; Yusheng SONG ; Yilong MA ; Tong DANG ; Hua XIANG ; Yun JIN ; Hui XUE ; Guiyun JIN ; Xiao LI ; Jiarui LI ; Shi ZHOU ; Changlu YU ; Song HE ; Lei YU ; Hongmei ZU ; Jun MA ; Yanming LEI ; Ke XU ; Xiaolong QI
Chinese Journal of Radiology 2024;58(4):437-443
Objective:To investigate the current situation of the use of transjugular intrahepatic portosystemic shunt (TIPS) for portal hypertension, which should aid the development of TIPS in China.Methods:The China Portal Hypertension Alliance (CHESS) initiated this study that comprehensively investigated the basic situation of TIPS for portal hypertension in China through network research. The survey included the following: the number of surgical cases, main indications, the development of Early-TIPS, TIPS for portal vein cavernous transformation, collateral circulation embolization, intraoperative portal pressure gradient measurement, commonly used stent types, conventional anticoagulation and time, postoperative follow-up, obstacles, and the application of domestic instruments.Results:According to the survey, a total of 13 527 TIPS operations were carried out in 545 hospitals participating in the survey in 2021, and 94.1% of the hospital had the habit of routine follow-up after TIPS. Most hospitals believed that the main indications of TIPS were the control of acute bleeding (42.6%) and the prevention of rebleeding (40.7%). 48.1% of the teams carried out early or priority TIPS, 53.0% of the teams carried out TIPS for the cavernous transformation of the portal vein, and 81.0% chose routine embolization of collateral circulation during operation. Most of them used coils and biological glue as embolic materials, and 78.5% of the team routinely performed intraoperative portal pressure gradient measurements. In selecting TIPS stents, 57.1% of the hospitals woulel choose Viator-specific stents, 57.2% woulel choose conventional anticoagulation after TIPS, and the duration of anticoagulation was between 3-6 months (55.4%). The limitation of TIPS surgery was mainly due to cost (72.3%) and insufficient understanding of doctors in related departments (77.4%). Most teams accepted the domestic instruments used in TIPS (92.7%).Conclusions:This survey shows that TIPS treatment is an essential part of treating portal hypertension in China. The total number of TIPS cases is far from that of patients with portal hypertension. In the future, it is still necessary to popularize TIPS technology and further standardize surgical indications, routine operations, and instrument application.
8.Analysis of specimen quality of intersphincteric resection for rectal cancer in the Chinese Transanal Total Mesorectal Excision Registry Collaborative database: a nationwide registered study
Pengyu WEI ; Mingyang REN ; Quan WANG ; Hong ZHANG ; Chienchih CHEN ; Qing XU ; Yi XIAO ; Dan MA ; Zhicong FU ; Dehai XIONG ; Yang LI ; Hongwei YAO ; Zhongtao ZHANG
Chinese Journal of Digestive Surgery 2024;23(6):819-825
Objective:To investigate the specimen quality of intersphincteric resection with transabdominal transanal mixed approach for rectal cancer in the Chinese Transanal Total Mesorectal Excision Registry Collaborative (CTRC) database.Methods:The retrospective case-control study was conducted. Based on the concept of real-world research, the clinicopathological data of 281 pati-ents with rectal cancer in the CTRC database who underwent intersphincteric resection with trans-abdominal transanal mixed approach in 19 medical centers, including the Beijing Friendship Hospital of Capital Medical University et al, from November 15,2017 to December 31,2023 were collected. There were 196 males and 85 females, aged 61(range, 27-87)years. Observation indicators: (1) preoperative examinations; (2) neoadjuvant therapy; (3) postoperative examinations; (4) analysis of influencing factors for positive circumferential margin in surgical specimen of intersphincteric resec-tion for rectal cancer. Measurement data with normal distribution were represented as Mean±SD. Measurement data with skewed distribution were represented as M(range). Count data were described as absolute numbers or percentages. The chi-square test was used for univariate analysis. Logistic regression model was used for multivariate analysis. Results:(1) Preoperative examinations. Of the 281 patients, 234 cases underwent preoperative pelvic magnetic resonance imaging (MRI) examina-tion. There were 2 cases in clinical stage T0, 3 cases in clinical stage T1, 58 cases in clinical stage T2, 137 cases in clinical stage T3, 24 cases in clinical stage T4, 3 cases in clinical stage Tx, 7 cases missing clinical T staging data. There were 87 cases in clinical stage N0, 68 cases in clinical stage N1, 60 cases in clinical stage N2, 9 cases in clinical stage Nx, 10 cases missing clinical N staging data. There were 30 cases with mesorectal fascia invasion, 53 cases with extramural venous invasion. The distance from lower margin of tumor to anal margin was 41.9(range, 1.0-80.0)mm. (2) Neoadjuvant therapy. Of the 281 patients, 125 cases underwent neoadjuvant therapy, including 39 cases receiving chemo-therapy alone, 6 cases receiving short-course simultaneous chemoradiotherapy, 5 cases receiving short-course simultaneous chemoradiotherapy and delayed surgery, 48 cases receiving long-course simultaneous chemoradiotherapy, 2 cases receiving other treatments, and 25 cases missing neoadju-vant therapy data. (3) Postoperative examinations. Of the 281 patients, 249 cases achieved R 0 resection, 9 cases achieved R 1 resection, and there were 23 cases missing surgical margin data. The maximum tumor diameter, the number of lymph nodes harvested and positive rate of vessel carcinoma embolus were 30.0(range, 0.5-200.0)mm, 13(range, 0-70) and 27.55%(73/265) in 281 patients. There were 252 patients with circumferential margin records, showing positive in 15 cases, with a positive rate as 5.95%(15/252). The minimum distance from deep part of tumor to circumferential margin was 7.0(range, 0-150.0)mm in 252 patients. There were 85 cases with distal margin records, showing positive in 1 case, and the distance from lower margin of tumor to distal margin was 10.0(range, 0-202.0)mm. There were 273 patients with specimen integrity records, which showed intact specimen in 208 cases, fair specimen in 58 cases, poor specimen in 4 cases, unevaluated specimen in 3 cases. There were 7 cases with rectal perforation. Of the 281 patients, cases in pathological stage T0, Tis, T1, T2, T3, T4 were 14, 5, 22, 107, 113, 12, respectively, and there were 8 cases missing pathological T staging data. Of the 281 patients, cases in pathological stage N0, N1a, N1b, N1c, N2a, N2b were 176, 27, 27, 11,20, 12, respectively, and there were 8 cases missing pathological N staging data. Of the 281 patients, there were 4 cases with distant metastasis, 262 cases without distant metastasis, 5 cases not evaluated, and 10 cases missing tumor metastasis data. Of the 125 patients undergoing neoadjuvant therapy, there were 85 cases with tumor regression grade records, including 16 cases as grade 1, 27 cases as grade 2, 19 cases as grade 3, 15 cases as grade 4, 8 cases as grade 5. (4) Analysis of influencing factors for positive circumferential margin in surgical specimen of intersphincteric resection for rectal cancer. Results of univariate analysis showed that preoperative T staging on preoperative pelvic MRI, mesorectal fascia invasion, extramural venous invasion, pathological T staging, and pathological N staging were related factors for positive circumferential margin in surgical specimen of intersphincteric resection for rectal cancer ( P<0.05). Conclusions:Intersph-incteric resection with transabdominal transanal mixed approach has good specimen quality and low positive rate of surgical margin. T staging on preoperative pelvic MRI may be related to positive circumferential margin after intersphincteric resection for rectal cancer.
9.Design and implementation of medical alliance nursing collaborative management system based on block chain
Mei-Gui CHEN ; Xu XU ; Xiao-Ping ZHU ; Xiong CHEN ; Qiao-Mei SHANG
Chinese Medical Equipment Journal 2024;45(3):47-55
Objective To design a medical alliance nursing collaborative management system based on block chain to provide technical support for nursing collaborative management.Methods A medical alliance system was designed based on the five-layer technical architecture of consortium blockchain,which used Linux system for establishing a Fabric development environment and network configuration,smart contract and Java language software development kit for realizing user interface operation,Bootstrap and Jquery technologies for constructing the front-end Web interface,Spring Boot for constructing the back-end interface.There were five functional modules for consortium blockchain member management,business management,data storage and sharing,patient medical record management and platform supervision involved in the system,which were developed with the technologies of encryption algorithm,hash operation,smart contract,consensus mechanism and etc.Results The system developed contributed to improving the mechanism for quality nursing resource sinking and continuous nursing care,reconfiguring the point incentive mechanism,promoting the collaborative development of nursing symbiotic network and enabling multi-node interactions to form a synergistic synergy.Conclusion The system developed conforms to the development trend of integrated care service of medical alliance,enhances the core competitiveness of nursing care and provides references for formulating blockchain solutions applicable to medical alliance scenarios.[Chinese Medical Equipment Journal,2024,45(3):47-55]
10.Troubleshooting of TMC BC ROBO 6 intelligent blood collection system:3 case reports
Xiong-Yi HUANG ; Xiao-Xiao HE ; Ke-Xin PAN ; Ao-Wen DUAN ; Li XU ; Kai MAO
Chinese Medical Equipment Journal 2024;45(6):113-116
The working principle of TMC BC ROBO 6 intelligent blood collection system was described in brief.The causes of three faults during daily operation of the system were analyzed,and the countermeasures were put forward accordingly.References were provided for clinical engineers to treat similar faults.[Chinese Medical Equipment Journal,2024,45(6):113-116]

Result Analysis